1.Development of intelligent equipment for rapid microbial detection of Atractylodis Macrocephalae Rhizoma decoction pieces based on measurement technology for traditional Chinese medicine manufacturing.
Yang LIU ; Wu-Zhen QI ; Yu-Tong WU ; Shan-Xi ZHU ; Xiao-Jun ZHAO ; Qia-Tong XIE ; Yu-Feng GUO ; Jing ZHAO ; Nan LI ; Shi-Jun WANG ; Qi-Hui SUN ; Zhi-Sheng WU
China Journal of Chinese Materia Medica 2025;50(16):4610-4618
Microbial detection and control of traditional Chinese medicine(TCM) decoction pieces are crucial for the quality control of TCM preparations. It is also a key area of research in the measurement technology and equipment development for TCM manufacturing. Guided by TCM manufacturing measurement methodologies, this study presented a design of a novel portable microbial detection device, using Atractylodis Macrocephalae Rhizoma decoction pieces as a demonstration. Immunomagnetic separation technology was employed for specific isolation and labeling of target microorganisms. Enzymatic signal amplification was utilized to convert weak biological signals into colorimetric signals, constructing an optical biosensor. A self-developed smartphone APP was further applied to analyze the colorimetric signals and quantify target concentrations. A portable and automated detection system based on Arduino microcontroller was developed to automatically perform target microbial separation/extraction, as well as mimetic enzyme labeling and catalytic reactions. The developed equipment specifically focuses on the rapid and quantitative microbial analysis of TCM active pharmaceutical ingredients, intermediates in TCM manufacturing, and final TCM products. Experimental results demonstrate that the equipment could detect Salmonella in samples within 2 h, with a detection limit as low as 5.1 × 10~3 CFU·mL~(-1). The equipment enables the rapid detection of microorganisms in TCM decoction pieces, providing a potential technical solution for on-site rapid screening of microbial contamination indicators in TCM. It has broad application prospects in measurement technology for TCM manufacturing and offers strong technical support for the modernization, industrialization, and intelligent development of TCM.
Drugs, Chinese Herbal/analysis*
;
Atractylodes/microbiology*
;
Rhizome/microbiology*
;
Biosensing Techniques/methods*
;
Medicine, Chinese Traditional
;
Colorimetry/instrumentation*
;
Quality Control
2.Study on the efficacy of automatic-controlled pressure cupping for lumbar disc herniation.
Bo-Chen PENG ; Min-Shan FENG ; Li LI ; Gui-Ju REN ; Yi-Zhen YUAN ; Li-Jie CHANG ; Shu-Ying REN ; Liu ZENG ; Guang-Wei LIU ; Li-Guo ZHU ; Na YUAN
China Journal of Orthopaedics and Traumatology 2025;38(11):1133-1138
OBJECTIVE:
To observe the clinical efficacy and safety of automatic pressure-controlled pressure cupping in patients with lumbar disc herniation, and compare it with traditional cupping.
METHODS:
A total of 100 patients diagnosed with lumbar disc herniation from January 2022 to August 2024 were selected and divided into two groups:the automatic pressure-controlled pressure cupping group (controlled pressure cupping group) and the traditional cupping group (control group), 50 cases in each group. In the controlled pressure cupping group, there were 18 males and 32 females, with an age of (51.98±12.69) years;in the control group, there were 16 males and 34 females, with an age of (51.32±12.05) years. The visual analogue scale(VAS), comfort score, and lumbar range of motion were observed before treatment and after the 1st, 3rd, and 7th treatments to evaluate the efficacy and safety.
RESULTS:
All patients completed the treatment intervention, with complete follow-up data collected. No adverse reactions or complications occurred during treatment and follow-up. After the 3rd treatment, the VAS score of the controlled pressure cupping group was (2.38±0.49), which was lower than that of the control group (2.94±0.68), with a statistically significant difference (P<0.001). In the controlled pressure cupping group, the VAS scores after the 1st, 3rd, and 7th treatments were significantly better than those before treatment (P=0.026);in the control group, the VAS scores after the 3rd and 7th treatments were better than those before treatment, but the difference was not statistically significant(P=0.182). Repeated-measures analysis of variance (ANOVA) on VAS scores at different time points in both groups showed that there were statistically significant differences in inter-group, time, and interaction effects (P<0.05). After the 1st treatment, in the controlled pressure cupping group, 0 patients felt comfortable, 42 patients (84%) felt mild discomfort, and 8 patients (16%) felt moderate discomfort;in the control group, 0 patients felt comfortable, 28 patients (56%) felt mild discomfort, and 22 patients(44%) felt moderate discomfort;the difference between the two groups was statistically significant(P=0.005). After the 3rd treatment, in the controlled pressure cupping group, 30 patients(60%) felt comfortable, 20 patients (40%) felt mild discomfort, and 0 patients felt moderate discomfort; in the control group, 9 patients (18%) felt comfortable, 41 patients (82%) felt mild discomfort, and 0 patients felt moderate discomfort;the difference between the two groups was statistically significant(P<0.001). There was no statistically significant difference in comfort between the two groups after the 7th treatment(P>0.001). There was no statistically significant difference in lumbar range of motion between the two groups before and after treatment(P>0.05);compared with before treatment, the lumbar range of motion of both groups after treatment was significantly improved, with statistically significant differences (P<0.001).
CONCLUSION
Automatic pressure-controlled pressure cupping can effectively relieve symptoms in patients with lumbar disc herniation, with excellent safety.
Humans
;
Female
;
Male
;
Intervertebral Disc Displacement/physiopathology*
;
Middle Aged
;
Adult
;
Lumbar Vertebrae/physiopathology*
;
Cupping Therapy/methods*
;
Pressure
;
Aged
;
Treatment Outcome
3.Effectiveness and safety of augmentative plating technique in managing nonunion following intramedullary nailing of long bones in the lower extremity: A systematic review and meta-analysis.
Cong-Xiao FU ; Hao GAO ; Jun REN ; Hu WANG ; Shuai-Kun LU ; Guo-Liang WANG ; Zhen-Feng ZHU ; Yun-Yan LIU ; Wen LUO ; Yong ZHANG ; Yun-Fei ZHANG
Chinese Journal of Traumatology 2025;28(3):164-174
PURPOSE:
To methodically assess the effectiveness of augmentative plating (AP) and exchange nailing (EN) in managing nonunion following intramedullary nailing for long bone fractures of the lower extremity.
METHODS:
PubMed, EMBASE, Web of Science, and the Cochrane Library were searched to gather clinical studies regarding the use of AP and EN techniques in the treatment of nonunion following intramedullary nailing of lower extremity long bones. The search was conducted up until May 2023. The original studies underwent an independent assessment of their quality, a process conducted utilizing the Newcastle-Ottawa scale. Data were retrieved from these studies, and meta-analysis was executed utilizing Review Manager 5.3.
RESULTS:
This meta-analysis included 8 studies involving 661 participants, with 305 in the AP group and 356 in the EN group. The results of the meta-analysis demonstrated that the AP group exhibited a higher rate of union (odds ratio: 8.61, 95% confidence intervals (CI): 4.12 - 17.99, p < 0.001), shorter union time (standardized mean difference (SMD): -1.08, 95% CI: -1.79 - -0.37, p = 0.003), reduced duration of the surgical procedure (SMD: -0.56, 95% CI: -0.93 - -0.19, p = 0.003), less bleeding (SMD: -1.5, 95% CI: -2.81 - -0.18, p = 0.03), and a lower incidence of complications (relative risk: -0.17, 95% CI: -0.27 - -0.06, p = 0.001). In the subgroup analysis, the time for union in the AP group in nonisthmal and isthmal nonunion of lower extremity long bones was shorter compared to the EN group (nonisthmal SMD: -1.94, 95% CI: -3.28 - -0.61, p < 0.001; isthmal SMD: -1.08, 95% CI: -1.64 - -0.52, p = 0.002).
CONCLUSION
In the treatment of nonunion in diaphyseal fractures of the long bones in the lower extremity, the AP approach is superior to EN, both intraoperatively (with reduced duration of the surgical procedure and diminished blood loss) and postoperatively (with an elevated union rate, shorter union time, and lower incidence of complications). Specifically, in the management of nonunion of lower extremity long bones with non-isthmal and isthmal intramedullary nails, AP demonstrated shorter union time in comparison to EN.
Humans
;
Bone Nails/adverse effects*
;
Bone Plates/adverse effects*
;
Femoral Fractures/surgery*
;
Fracture Fixation, Intramedullary/methods*
;
Fractures, Ununited/surgery*
;
Lower Extremity/injuries*
4.Expert consensus on prevention and control of Chikungunya in healthcare institutions(2025 Edition)
Ling HE ; Yan LIU ; Fang YU ; Ying LIU ; Dayue LIU ; Hongyan LIU ; Ruiting WANG ; Shuxian CHEN ; Chen ZHU ; Xiaodong HAN ; Ting HUANG ; Fengxia GUO ; Zhen-feng ZHONG ; Yuanchun MO ; Xiujuan QU ; Yinan LI ; Yi XU ; Chengxiang KONG ; Ning LI ; Shaoyan LU ; Ming WU ; Zide DENG ; Shumei SUN
Chinese Journal of Nosocomiology 2025;35(22):3361-3369
OBJECTIVE To standardize the strategies for prevention and control of Chikungunya(CHIK)in healthcare in-stitutions so as to reduce the risk of transmission in the institutions.METHODS A working group comprising the ex-perts in hospital infection control,infectious diseases,and microbiology systematically reviewed domestic and international evidence and current guidelines,integrated China's vector ecology and healthcare realities,conducted two rounds of Delphi to achieve expert consensus,and graded the evidence and recommendation strength using the Oxford Centre for Evidence Based Medicine system.RESULTS The consensus issues 18 actionable recommendations on triage,patient mosquito-proof isolation,integrated vector control,protection of susceptible populations,environmental cleaning and disinfection,specimen management,medical textile handling,and outbreak emergency response,with each statement assigned an evi-dence level and recommendation strength.CONCLUSION This consensus is for the first time in China to provide evidence-graded strategies for control of CHIK in healthcare institutions,offering work flow-oriented,implementable guidance for clinicians,laboratorians,and infection-control personnel under different risk scenarios and enhancing the comprehensive coping capacity of the healthcare institutions.
5.Robot system-assisted versus freehand screw revision for ankylosing spondylitis with lower cervical fractures: a multicenter retrospective study
Shuai LI ; Jiaojiao BAI ; Baorong HE ; Yanzheng GAO ; Wei MEI ; Xinyu LIU ; Yue ZHU ; Qingda LI ; Yukuan LEI ; Lei ZHU ; Zhigang ZHAO ; Yunfei HUANG ; Jinpeng DU ; Mingzhe FENG ; Ningbo CHEN ; Yansheng HUANG ; Xuefang ZHANG ; Zhen CHANG
Chinese Journal of Trauma 2025;41(5):440-448
Objective:To compare the efficacy of robot system-assisted versus freehand screw revision for ankylosing spondylitis (AS) with lower cervical fractures.Methods:A multicenter retrospective cohort study was conducted to analyze the clinical data of 57 patients with AS combined with lower cervical fractures admitted to Honghui Hospital Affiliated to Xi'an Jiaotong University School of Medicine, Henan Provincial People's Hospital, Zhengzhou Orthopedic Hospital, and Qilu Hospital of Shandong University, including 46 males and 11 females, aged 38-77 years [(65.4±9.5)years]. Injury segments involved C 3 in 7 patients, C 4 in 13, C 5 in 25, C 6 in 10, and C 7 in 2. All the patients underwent revision surgery, among whom, 22 patients were treated with robot system-assisted cervical pedicle screw placement (robot nailing group, with 190 screws), and 35 with freehand cervical pedicle screw placement (freehand nailing group, with 300 screws). The operative duration, intraoperative bleeding volume, frequency of intraoperative fluoroscopy, incision length, and length of hospital stay of the two groups were compared; the time of single nscrew insertion, the number of single nail revisions, the distance between screws and the anterior cortex, the accuracy of screw placement of grade 0 and grade 0+1 were recorded in the two groups. The visual analogue scale (VAS), Japanese Orthopedic Society (JOA) score, neck dysfunction index (NDI), American Spine Injury Association (ASIA) classification before operation, at 3 days, 3 months after operation and at the last follow-up were compared between the two groups. The complication rate was also noted. Results:All the patients were followed up for 12-16 months [(14.3±2.1)months]. The operative duration, intraoperative bleeding volume, and frequency of intraoperative fluoroscopy were (186.4±12.9)minutes, (486.1±68.6)ml, and (3.4±1.3)times in the robot nailing group, which were shorter or less than (206.7±14.4)minutes, (660.3±45.2)ml, and (13.5±3.6)times in the freehand nailing group ( P<0.01). The incision length was (9.4±2.4)cm in the robot nailing group, longer than (5.6±1.2)cm in the freehand nailing group ( P<0.01), and the length of hospital stay was (3.7±0.4)days, shorter than (4.4±1.4)days in the freehand nailing group ( P<0.01). The length of single nail insertion, the number of single nail revision, and the distance between the screws and the front cortex were (6.5±0.4)minutes, (1.1±0.1)times, and (3.5±1.3)mm in the robot nailing group, which were shorter or less than (11.6±0.2)minutes, (1.5±0.2)times, and (12.4±4.7)mm in the freehand nailing group ( P<0.01). The accuracy of the screw placement in the robot nailing group was 90.0% (171/190) and 95.8% (182/190) with level 0 and 0+1 screws, better than 80.0% (240/300) and 89.0% (267/300) in the freehand nailing group ( P<0.05). There was no significant difference in VAS, JOA score, NDI, or ASIA grading between the two groups before operation ( P>0.05). The VAS, JOA, and NDI scores at 3 days after operation were (3.1±0.6)points, (12.1±1.2)points, and (15.6±2.9)points, respectively in the robot nailing group, which were better than (5.0±1.4)points, (11.3±1.1)points and (22.5±3.7)points, respectively in the freehand nailing group ( P<0.05). No statistically significant difference was observed in the ASIA grade between the two groups at 3 days after operation ( P>0.05). There were no significant differences in VAS, JOA, NDI scores, or ASIA grading between the two groups at 3 months after operation and at the last follow-up ( P>0.05). Compared with those before operation, the VAS, JOA, NDI scores, and ASIA grading were significantly improved at 3 days, 3 months after operation and at the last follow-up in the two groups, which were further improved with the passage of time. Two patients in the robot nailing group had pneumonia, with a complication rate of 9% (2/22), while 2 patients in the freehand nailing group had dural sac rupture and cerebrospinal fluid leakage and 3 had lung infection after operation, with a complication rate of 14% (5/35) ( P<0.05). Conclusion:Compared with freehand nailing, the robot system-assisted nailing revision for AS with lower cervical fracture has more advantages in terms of the operative duration, length of hospital stay, intraoperative bleeding volume, frequency of intraoperative fluoroscopy nailing speed and accuracy, screw holding force, early pain relief, function restoration, and complication rate, despite longer surgical incision.
6.Comparative efficacy of navigation system and orthopedic robot-assisted nail placement in the treatment of lower cervical fracture and dislocation
Xinnan CHENG ; Shuai LI ; Jiaojiao BAI ; Qingda LI ; Yukuan LEI ; Lei ZHU ; Zhen CHANG ; Zhigang ZHAO ; Yunfei HUANG ; Mingzhe FENG ; Liang YAN ; Hua HUI ; Lingbo KONG ; Baorong HE
Chinese Journal of Trauma 2025;41(2):148-156
Objective:To compare the clinical efficacy of navigation system and orthopedic robot-assisted nail placement in the treatment of lower cervical fracture and dislocation.Methods:A retrospective cohort study was conducted to analyze the clinical data of 49 patients with fracture and dislocation of the lower cervical spine who were admitted to Honghui Hospital, Xi′an Jiaotong University School of Medicine from May 2021 to October 2022, including 38 males and 11 females, aged 29-61 years [(39.3±7.3)years]. Injury segments involved C 3 in 12 patients, C 4 in 11, C 5 in 8, C 6 in 9 and C 7 in 9. Twenty-one patients were treated with S8 navigation system (navigation group, 84 screws), and 28 with TINAVI orthopedic robot (robot group, 112 screws). The two groups were compared in terms of the total surgical duration, single screw placement time, total screw placement time, distance between the screw and the anterior cortex, incision length, intraoperative radiation dose, intraoperative blood loss and length of hospital stay. The height of intervertebral space, Cobb angle, sliding distance between vertebral bodies and American Spinal Injury Association (ASIA) grade were assessed before surgery and at 3 days after surgery. Visual analogue scale (VAS), Japanese Orthopedic Association (JOA) score and neck dysfunction index (NDI) before surgery, at 3 days, 3 months after surgery and at the last follow-up were compared. The accuracy of screw placement, intraoperative invasion rate of adjacent facet joints and rate of postoperative complications (infection, screw loosening, etc.) were evaluated. Results:All the patients were followed up for 12-16 months [(13.6±1.9)months]. In the navigation group, the total surgical duration, distance from the screw to the anterior cortex and the intraoperative radiation dose were (236.2±30.6)minutes, (2.0±0.2)mm and (374.3±90.3)mGy respectively, which were significantly shorter or less than those in the robot group [(278.4±20.7)minutes, (10.6±2.9)mm and (448.4±77.9)mGy] ( P<0.01). The single screw placement time, total screw placement time, incision length and intraoperative blood loss were (3.5±0.4)minutes, (23.9±0.5)minutes, (9.1±2.4)cm and (422.2±30.4)ml respectively, which were significantly longer or more than those in the robot group [(2.6±0.2)minutes, (17.9±0.7)minutes, (6.6±2.6)cm and (360.3±56.3)ml] ( P<0.01). There was no significant difference in the length of hospital stay between the two groups ( P>0.05). No significant differences were observed in the height of the intervertebral space, Cobb angle, sliding distance between the vertebral bodies and ASIA grade between the two groups ( P>0.05). At 3 days after surgery, the height of intervertebral space, Cobb angle, sliding distance between vertebral bodies and ASIA grade in both groups were significantly improved when compared with those before surgery ( P<0.05 or 0.01). There were no significant differences in VAS, JOA scores or NDI between the two groups before surgery, at 3 days, 3 months after surgery and at the last follow-up ( P>0.05). The VAS, JOA scores and NDI in both groups were gradually improved at 3 days, 3 months and at the last follow-up after surgery when compared with those before surgery ( P<0.05). There was no significant difference in the accuracy of screw placement of levels 0 and 0+1 between the two groups ( P>0.05). No significant difference in the intraoperative invasion rate of adjacent facet joints between the two groups was found ( P>0.05). There were no serious complications such as infection or screw loosening after surgery in both groups. Conclusions:For lower cervical fracture and dislocation, although there are more advantages in total surgical duration, screw holding force and radiation control regarding the navigation system, and more outstanding performance in screw placement efficiency, incision length and intraoperative blood loss regarding the orthopedic robot, both of them can effectively rebuild the cervical structure, improve neurological function, relieve postoperative pain, improve screw placement accuracy and reduce facet joint injury and serious complications. Selection of the best auxiliary screw placement system should comprehensively consider patients′ conditions and the experience of the surgical team.
7.A new glycoside from Alstonia mairei Lévl.
Li-ke WANG ; Bing-yan LI ; Zhen-zhu ZHAO ; Yan-zhi WANG ; Xiao-kun LI ; Wei-sheng FENG ; Ying-ying SI
Acta Pharmaceutica Sinica 2025;60(1):191-195
Nine compounds were isolated and purified from 90% ethanol extract of
8.Role of SWI/SNF Chromatin Remodeling Complex in Tumor Drug Resistance
Gui-Zhen ZHU ; Qiao YE ; Yuan LUO ; Jie PENG ; Lu WANG ; Zhao-Ting YANG ; Feng-Sen DUAN ; Bing-Qian GUO ; Zhu-Song MEI ; Guang-Yun WANG
Progress in Biochemistry and Biophysics 2025;52(1):20-31
Tumor drug resistance is an important problem in the failure of chemotherapy and targeted drug therapy, which is a complex process involving chromatin remodeling. SWI/SNF is one of the most studied ATP-dependent chromatin remodeling complexes in tumorigenesis, which plays an important role in the coordination of chromatin structural stability, gene expression, and post-translation modification. However, its mechanism in tumor drug resistance has not been systematically combed. SWI/SNF can be divided into 3 types according to its subunit composition: BAF, PBAF, and ncBAF. These 3 subtypes all contain two mutually exclusive ATPase catalytic subunits (SMARCA2 or SMARCA4), core subunits (SMARCC1 and SMARCD1), and regulatory subunits (ARID1A, PBRM1, and ACTB, etc.), which can control gene expression by regulating chromatin structure. The change of SWI/SNF complex subunits is one of the important factors of tumor drug resistance and progress. SMARCA4 and ARID1A are the most widely studied subunits in tumor drug resistance. Low expression of SMARCA4 can lead to the deletion of the transcription inhibitor of the BCL2L1 gene in mantle cell lymphoma, which will result in transcription up-regulation and significant resistance to the combination therapy of ibrutinib and venetoclax. Low expression of SMARCA4 and high expression of SMARCA2 can activate the FGFR1-pERK1/2 signaling pathway in ovarian high-grade serous carcinoma cells, which induces the overexpression of anti-apoptosis gene BCL2 and results in carboplatin resistance. SMARCA4 deletion can up-regulate epithelial-mesenchymal transition (EMT) by activating YAP1 gene expression in triple-negative breast cancer. It can also reduce the expression of Ca2+ channel IP3R3 in ovarian and lung cancer, resulting in the transfer of Ca2+ needed to induce apoptosis from endoplasmic reticulum to mitochondria damage. Thus, these two tumors are resistant to cisplatin. It has been found that verteporfin can overcome the drug resistance induced by SMARCA4 deletion. However, this inhibitor has not been applied in clinical practice. Therefore, it is a promising research direction to develop SWI/SNF ATPase targeted drugs with high oral bioavailability to treat patients with tumor resistance induced by low expression or deletion of SMARCA4. ARID1A deletion can activate the expression of ANXA1 protein in HER2+ breast cancer cells or down-regulate the expression of progesterone receptor B protein in endometrial cancer cells. The drug resistance of these two tumor cells to trastuzumab or progesterone is induced by activating AKT pathway. ARID1A deletion in ovarian cancer can increase the expression of MRP2 protein and make it resistant to carboplatin and paclitaxel. ARID1A deletion also can up-regulate the phosphorylation levels of EGFR, ErbB2, and RAF1 oncogene proteins.The ErbB and VEGF pathway are activated and EMT is increased. As a result, lung adenocarcinoma is resistant to epidermal growth factor receptor tyrosine kinase inhibitors (EGFR-TKIs). Although great progress has been made in the research on the mechanism of SWI/SNF complex inducing tumor drug resistance, most of the research is still at the protein level. It is necessary to comprehensively and deeply explore the detailed mechanism of drug resistance from gene, transcription, protein, and metabolite levels by using multi-omics techniques, which can provide sufficient theoretical basis for the diagnosis and treatment of poor tumor prognosis caused by mutation or abnormal expression of SWI/SNF subunits in clinical practice.
9.Validation and Forensic Application of a Domestic Human DNA Quantitative De-tection Kit
Jing CHEN ; Ya-Ping WANG ; Yun-Peng FENG ; Xiao-Xin HU ; Zhen-Jun JIA ; Hong-Di LIU ; An-Xin YAN ; Yong-Jiu LI ; Zhu PENG ; Zhi-Fang LIU ; Jian-Gang CHEN
Journal of Forensic Medicine 2025;41(3):252-259
Objective To verify the efficacy of a domestic human DNA quantification kit based on real-time fluorescence quantitative PCR in detecting the total human DNA concentration,male DNA concen-tration in mixed male/female DNA samples,the degree of DNA degradation and inhibitor tolerance.Methods Samples with different concentrations,different male/female ratios,different concentrations of inhibitors,and different degradation degrees were tested using the domestic human DNA quantification kit based on real-time fluorescence quantitative PCR.This kit was compared with a similar product on the market and was applied to the detection of DNA from real cases.Results This human DNA quan-tification kit can effectively detect human DNA as low as 0.001 65 ng/μL,and 6.25 pg/μL of male DNA in mixed samples with a male-to-female ratio of 1∶15 000.Even when the sample contains as high as 400 ng/μL of humic acid or 1 000 μmol/L of hemin alone,the DNA concentration can still be accurately detected.The degradation index can effectively characterize the degradation degree of the sample.This kit has been successfully applied in forensic practice.Conclusion This human DNA quan-tification kit is accurate and reliable in detection.It can accurately reflect the degradation of DNA and inhibitor tolerance.It has good performance in quantitative accuracy,determination of the male/female ratio in mixed samples,and inhibitor tolerance.It has application potential in forensic case examination.
10.Role of collapsin response mediator proteins in optic nerve injury
Yuchun ZHU ; Xinyuan XI ; Zhen YANG ; Dongfu FENG
Basic & Clinical Medicine 2025;45(1):102-106
Collapsin response mediator proteins(CRMPs),also known as dihydropyrimidine-like proteins,contain five isoforms(CRMP1,CRMP2,CRMP3,CRMP4,CRMP5).In central nervous system,CRMPs are mainly in-volved in a variety of physiological processes such as neuronal differentiation and migration,synaptic plasticity,neurite growth and development and guiding extension.Recent studies have found that inhibiting or reducing the phosphorylation of CRMPs can affect the survival and axonal regeneration of retinal ganglion cells(RGCs)after op-tic nerve injury,which may provide new ideas for the treatment of optic nerve injury in the future.

Result Analysis
Print
Save