1.LINC00657 Promotes Malignant Progression of Cervical Cancer by Sponging miR-30a-5p to Regulate Skp2 Expression
Changhui ZHOU ; Jingqin REN ; Zhen CHEN ; Qi YAN ; Nan YANG ; Jiaqi ZHAO ; Rong LI
Cancer Research on Prevention and Treatment 2026;53(2):103-111
Objective To investigate the role and regulatory mechanism of LINC00657 in the progression of cervical cancer. Methods Bioinformatics analysis predicted potential binding sites between LINC00657 and miR-30a-5p and between miR-30a-5p and Skp2. These sites were verified by using RNA immunoprecipitation and dual-luciferase reporter experiments. LINC00657, miR-30a-5p, and Skp2 mRNA expression levels in cervical cancer tissues and cell lines were assessed by utilizing RT-qPCR. Western blot analysis was employed to examine the protein levels of Skp2 in cells and subcutaneous xenograft tumor models in nude mice. Immunohistochemistry was applied to analyze Skp2 expression in animal tissues. The cellular processes of cervical cancer cell lines were evaluated through CCK-8, scratch, and Transwell assays. Results LINC00657 and Skp2 presented binding sites for miR-30a-5p. In cervical cancer, LINC00657 and Skp2 showed high expression levels (P<0.05), whereas miR-30a-5p displayed low expression (P<0.05). Functional experiments demonstrated that linc00657 upregulates Skp2 expression, a process that is dependent on its sequestration of miR-30a-5p. Conclusion LINC00657 promoted the malignant progression of cervical cancer by upregulating Skp2 expression through specifically sequestering miR-30a-5p, thereby relieving its inhibitory effect on the target gene Skp2.
2.Pre-operative risk assessment of hepatocellular carcinoma recurrence in liver transplant recipients by non-invasive detection of pre-existing genetic lesions
Suqin YANG ; Sunbin LING ; Jianhua LI ; Yan WANG ; Jiapei WANG ; Qiwei HUANG ; Fanming LIU ; Yiqi ZHUANG ; Yingyu ZHENG ; Rui WANG ; Zhe YANG ; Xiaoping ZHENG ; Kai WANG ; Zhikun LIU ; Jun CHEN ; Jianguo WANG ; Haiyang XIE ; Lin ZHOU ; Leiming CHEN ; Guoqiang CAO ; Dandan CHEN ; Junfang JI ; Bin ZHAO ; Chao JIANG ; Di LU ; Xuyong WEI ; Hangjin JIANG ; Qiaonan SHAN ; Hengbo SHI ; Yong-Zhen XU ; Shusen ZHENG ; Zhengxin WANG ; Shengda LIN ; Xiao XU
Clinical and Molecular Hepatology 2026;32(2):884-903
Background/Aims:
Liver transplantation (LT) following total hepatectomy is a life-saving treatment for hepatocellular carcinoma (HCC). The HCC recurrence after LT hinders the effectiveness of the procedure. The objective of this study is to develop a pre-operative risk stratification model based on a liquid biopsy.
Methods:
We conducted a comprehensive multi-omics study of 260 HCC patients from three centers, including clinical data, low-coverage whole-genome sequencing of cell-free DNA (cfDNA) from plasma, as well as whole-exome, single-nucleus RNA, and spatial transcriptomics from matched tumor and non-tumor tissues.
Results:
We identified cfDNA-derived copy number alteration (CNA) signatures associated with post-transplant recurrence. By integrating cfDNA-derived CNA profiles with single-cell transcriptomic data, we traced recurrence-associated cfDNA to a distinct subpopulation of malignant cells within the primary tumor. These cells were embedded in a pro-metastatic microenvironment of specialized endothelial subtypes and cancer-associated fibroblasts. Notably, most recurrence-associated lesions were detectable in cfDNA prior to liver transplantation (LT). Building on these insights, we developed the ZJU Criteria based on CNA fragments and tumor markers, a pre-LT risk prediction tool that integrates conventional clinical factors with cfDNA-derived CNA signatures, and validated it using internal and independent external cohorts.
Conclusion
Our findings suggest that post-transplant recurrence commonly originates from advanced subclones that emerge late during tumor evolution. The ZJU Criteria provides an accurate, non-invasive strategy that significantly improves pre-LT risk stratification and clinical decision-making for patients with HCC.
3.A new glycoside from Alstonia mairei Lévl.
Li-ke WANG ; Bing-yan LI ; Zhen-zhu ZHAO ; Yan-zhi WANG ; Xiao-kun LI ; Wei-sheng FENG ; Ying-ying SI
Acta Pharmaceutica Sinica 2025;60(1):191-195
Nine compounds were isolated and purified from 90% ethanol extract of
4.Application of a wearable visual field meter based on extended reality glasses in macular disease
Jing YUAN ; Xingchang WANG ; Xiquan SUN ; Huiguang JIAO ; Qian WANG ; Yanxia TONG ; Biyue TU ; Xixi YAN ; Zhen ZHAO ; Xiaojie OU ; Sawut ABDULLA
Chinese Journal of Experimental Ophthalmology 2025;43(11):1035-1040
Objective:To evaluate the application effect of a wearable visual field meter based on extended reality (XR) glasses for patients with macular disease.Methods:A self-controlled study was conducted.A total of 41 consecutive patients (41 eyes) with macular disease were recruited at Renmin Hospital of Wuhan University from October 2022 to October 2024.All patients underwent 10-2 center visual field test using a self-developed wearable visual field meter (XRVF), and the results were compared with those obtained using a traditional Humphrey field analyzer (HFA).The comparison parameters included mean retinal sensitivity (MS), false positive rate (FPR), false negative rate (FNR), and testing duration.A subject satisfaction questionnaire was administered.This study followed the Declaration of Helsinki.The study protocol was approved by the Medical Ethics Committee of Renmin Hospital of Wuhan University (No.WDRY2024-K263), and all subjects signed the informed consent form.Results:The retinal sensitivity of patients measured by HFA was (23.24±3.71)dB, which was higher than (22.01±3.45)dB by XRVF, showing a statistically significant difference ( t=4.924, P=0.036).The FPR measured by HFA and XRVF were (2.39±2.51)% and (2.59±3.29)%, respectively, and the FNR were (3.49±6.05)% and (3.74±5.38)%, respectively, showing no statistically significant difference ( t=-3.624, P=0.948; t=-1.241, P=0.519).The median test duration for HFA and XRVF was 6.15 (5.78, 6.65) and 5.98 (5.71, 6.69)minutes, respectively, without statistically significant difference ( Z=-1.987, P=0.953).92.6% of the subjects thought the device was comfortable, simple and practical. Conclusions:The XRVF has good consistency with the HFA, can effectively and reliably evaluate the visual field function of patients with macular disease, and is easily accepted by patients.
5.PSO algorithm-based optimization study of water conductivity control system for pharmaceutical water equipment of full membrane process
Lin-yong LIU ; Jun MA ; Hong-bin LIU ; Jian-jun SUN ; Yan-jun ZHANG ; Xiu-guo ZHAO ; Zhen-xing SONG
Chinese Medical Equipment Journal 2025;46(6):14-19
Objective To optimize the design of the existing water conductivity control system for pharmaceutical water equipment of full membrane process so as to solve its problems in precision and long cycle time due to water source,ambient temperature and intermittent working mode.Methods The optimized water conductivity control system was composed of an alkali metering pump,a conductivity sensor and a programmable logic controller(PLC),which used a fuzzy proportional-integral-derivative(PID)controller to regulate the water conductivity of pharmaceutical water equipment of full membrane process,and the particle swarm optimization(PSO)algorithm to optimize the parameters of the fuzzy PID controller.A simulation model was established with MATLAB software to verify the performance of the optimized control system.Results Simulation results showed the optimized control system had reductions in overshoot(by 19%)and adjustment time(by 29%)when compared with the fuzzy PID control system,and enhanced control efficiency effectively.Conclusion The optimized control system optimized by the PSO algorithm improves the quality of produced water,and can meet the demands for rapid and safe production of pharmaceutical water by pharmaceutical water equipment of full membrane process in different conditions.[Chinese Medical Equipment Journal,2025,46(6):14-19]
6.Mechanisms and intervention strategies of aging based on epigenetics
Li-yuan ZHANG ; Hao-nan SHI ; Wen-feng ZHANG ; Ming-qian ZHANG ; Zi-yang ZHAO ; Zhen-zhen CHENG ; Ti ZHANG ; Zhen-teng YAN ; Jian-ning SUN ; Shi-fen DONG
Chinese Pharmacological Bulletin 2025;41(12):2230-2235
Aging is comprehensively influenced by multiple fac-tors such as internal genes,cellular metabolism,external envi-ronment,and lifestyle habits.Among them,epigenetic regula-tion plays a core role.Epigenetic modifications,including DNA methylation,histone modification,heterochromatin remodeling,and non-coding RNA regulation,act in concert with the three-di-mensional genome architecture to precisely regulate gene expres-sion.This review elaborates on the factors influencing epigenetic regulation,as well as the mechanisms of how epigenetics affects the occurrence of organismal aging and the corresponding inter-vention strategies,providing relevant insights for uncovering the mechanisms of aging and preventing/treating aging-related disea-ses.
7.Effect of drug-eluting bead DACE combined with systemic treatment for hepatocellular carcinoma in different locations
Xingli YAN ; Zhen LI ; Jie LI ; Luqi HU ; Yifan LI ; Yanan ZHAO ; Yuyuan ZHANG ; Junying LIU ; Pengchao ZHAN ; Xin LI ; Peijie LYU ; Yancang ZHANG
Chinese Journal of Interventional Imaging and Therapy 2025;22(4):238-242
Objective To investigate the effect of drug-eluting bead DACE(DEB-TACE)combined with systemic treatment for hepatocellular carcinoma(HCC)in different locations.Methods A total of 204 HCC patients who underwent DEB-TACE combined with systemic therapy(targeted and immunotherapy)were retrospectively collected.According to the anatomical location of HCC,86 cases with lesions located at the main trunk of portal vein(PV)or within 1 cm of the first PV branch were classified into central type group,while 118 cases with lesions located at the other areas were classified as peripheral type group.Follow-up was regularly performed after DEB-TACE until August,2024.The objective response rate(ORR)and disease control rate(DCR)at 1,3,6 and 12 months after DEB-TACE,also patients'progression-free survival(PFS)and overall survival(OS)were compared between groups.Results All patients were followed up for a median of 32.6 months,during which 164 cases died.Significant differences of ORR at 1 and 3 months after DEB-TACE(77.91%[67/86]vs.89.83%[106/118],34.88%[30/86]vs.54.24%[64/118])and DCR at 3 and 6 months after DEB-TACE(51.16%[44/86]vs.66.95%[79/118],34.88%[30/86]vs.50.00%[59/118])were found between groups(all P<0.05).Patients'PFS(30.18[9.12,48.54]months)and OS(37.36[17.79,56.68])in peripheral type group were better than those in central type group(20.11[11.35,28.87]months and 23.24[3.11,43.47]months,x2=3.971,4.162,P=0.048,0.041).Conclusion The effect of DEB-TACE combined with systemic treatment for peripheral type HCC was better than for central type HCC.
8.Application of a wearable visual field meter based on extended reality glasses in macular disease
Jing YUAN ; Xingchang WANG ; Xiquan SUN ; Huiguang JIAO ; Qian WANG ; Yanxia TONG ; Biyue TU ; Xixi YAN ; Zhen ZHAO ; Xiaojie OU ; Sawut ABDULLA
Chinese Journal of Experimental Ophthalmology 2025;43(11):1035-1040
Objective:To evaluate the application effect of a wearable visual field meter based on extended reality (XR) glasses for patients with macular disease.Methods:A self-controlled study was conducted.A total of 41 consecutive patients (41 eyes) with macular disease were recruited at Renmin Hospital of Wuhan University from October 2022 to October 2024.All patients underwent 10-2 center visual field test using a self-developed wearable visual field meter (XRVF), and the results were compared with those obtained using a traditional Humphrey field analyzer (HFA).The comparison parameters included mean retinal sensitivity (MS), false positive rate (FPR), false negative rate (FNR), and testing duration.A subject satisfaction questionnaire was administered.This study followed the Declaration of Helsinki.The study protocol was approved by the Medical Ethics Committee of Renmin Hospital of Wuhan University (No.WDRY2024-K263), and all subjects signed the informed consent form.Results:The retinal sensitivity of patients measured by HFA was (23.24±3.71)dB, which was higher than (22.01±3.45)dB by XRVF, showing a statistically significant difference ( t=4.924, P=0.036).The FPR measured by HFA and XRVF were (2.39±2.51)% and (2.59±3.29)%, respectively, and the FNR were (3.49±6.05)% and (3.74±5.38)%, respectively, showing no statistically significant difference ( t=-3.624, P=0.948; t=-1.241, P=0.519).The median test duration for HFA and XRVF was 6.15 (5.78, 6.65) and 5.98 (5.71, 6.69)minutes, respectively, without statistically significant difference ( Z=-1.987, P=0.953).92.6% of the subjects thought the device was comfortable, simple and practical. Conclusions:The XRVF has good consistency with the HFA, can effectively and reliably evaluate the visual field function of patients with macular disease, and is easily accepted by patients.
9.Comparative efficacy of laminoplasty via intermuscular approach or posterior midline approach for cervical spinal cord injury without radiographic abnormality: a multi-center retrospective study
Yunfei HUANG ; Shuai LI ; Jinpeng DU ; Baorong HE ; Yanzheng GAO ; Wei MEI ; Shibao LU ; Zhigan ZHAO ; Liang YAN ; Xiaobin YANG ; Yuan HE ; Zhen CHANG
Chinese Journal of Trauma 2025;41(7):635-644
Objective:To compare the efficacy of laminoplasty via the intermuscular approach or posterior midline approach for treating spinal cord injury without radiographic abnormality (SCIWORA).Methods:A multi-center retrospective cohort study was conducted to analyze the clinical data of 135 patients with SCIWORA admitted to Honghui Hospital Affiliated to Xi'an Jiaotong University School of Medicine, Xi'an No.5 Hospital, Henan Provincial People's Hospital, Zhengzhou Orthopedic Hospital, Xuanwu Hospital of Capital Medical University from February 2021 to June 2023, including 75 males and 60 females, aged 35-78 years [(55.3±8.1)years]. The injury segments involved C 3-C 6. All the patients underwent posterior cervical open-door laminoplasty, among whom 70 patients were treated via the intermuscular approach (intermuscular group) and 65 via the posterior midline approach (posterior midline group). The operation duration, intraoperative blood loss, postoperative drainage volume, and length of hospital stay were recorded. The visual analogue scale (VAS) score, Japanese Orthopedic Association (JOA) score, neck disability index (NDI), Barthel index, cervical Cobb angle, and cervical range of motion (ROM) were measured preoperatively, at 3, 6, 12 months postoperatively and at the final follow-up. The American Spinal Injury Association (ASIA) scale was evaluated preoperatively, at 3, 12 months postoperatively and at the final follow-up. The postoperative complication rate was recorded as well. Results:All the patients were followed up for 15-19 months [(16.3±1.6)months]. The operation duration, intraoperative blood loss, postoperative drainage and length of hospital stay were (125.0±23.0)minutes, (210.4±34.8)ml, and (165.3±23.7)ml, and (5.3±0.1)days in the intermuscular group, which were significantly shorter or less than (168.0±27.6)minutes, (260.2±45.3)ml, (196.4±31.6)ml, and (6.4±0.2)days in the posterior midline group ( P<0.01). The preoperative VAS score, JOA score, NDI and Barthel index showed no significant differences between the two groups ( P>0.05). The VAS score and JOA score also showed no significant differences between the two groups at 3, 6, 12 months postoperatively or at the final follow-up ( P>0.05). The NDI and Barthel index also showed no significant differences between the two groups at 3 months postoperatively ( P>0.05). At 6, 12 months postoperatively and at the final follow-up, the NDI were (15.4±2.5)points, (11.8±2.1)points and (8.6±1.5)points in the intermuscular group, significantly lower than (19.1±3.4)points, (14.3±2.4)points and (11.9±1.4)points in the posterior midline group ( P<0.01). At 6, 12 months postoperatively and at the final follow-up, the Barthel index were (71.4±6.2)points, (83.4±5.8)points and (89.2±7.1)points in the intermuscular group, significantly higher than (59.6±4.7)points, (74.2±3.9)points and (78.8±6.2)points in the posterior midline group ( P<0.01). Both groups showed significant improvements in VAS score, JOA score, NDI and Barthel index at 3, 6, 12 months postoperatively and at the final follow-up when compared to those preoperatively ( P<0.05). Among them, the VAS score, NDI and Barthel index were further improved over time ( P<0.05). Simultaneously, the JOA score was significantly improved at 6, 12 months postoperatively and at the last follow-up when compared to that at 3 months postoperatively ( P<0.05), with no significant difference at later time points between the two groups ( P>0.05). The preoperative cervical Cobb angle and ROM showed no significant differences between the two groups ( P>0.05). There was no significant difference in the Cobb angle between the two groups at 3, 6 or 12 months postoperatively ( P>0.05), while it was (13.6±2.4)° in the intermuscular group at the final follow-up, significantly larger than (10.4±2.8)° in the posterior midline group ( P<0.01). At 3, 6, 12 months postoperatively and at the final follow-up, the cervical ROM were (34.1±6.4)°, (32.6±7.3)°, (31.8±9.1)° and (29.6±8.7)° in the intermuscular group, significantly larger than (23.7±8.3)°, (22.3±7.8)°, (22.5±8.1)° and (20.6±9.3)° in the posterior midline group ( P<0.01). In the intermuscular group, the cervical Cobb angle showed no significant changes at 3, 6, 12 months postoperatively and at the final follow-up when compared to those preoperatively ( P>0.05). In the posterior midline group, the Cobb angles were significantly reduced at 3, 6, 12 months postoperatively and at the final follow-up when compared to those preoperatively ( P<0.05), showing significant decrease at 12 months postoperatively and at the final follow-up from those at 3, 6 months postoperatively ( P<0.05), no significant difference at 6 months postoperatively from that at 3 months postoperatively ( P>0.05), and significant decrease at the final follow-up from that at 12 months postoperatively ( P>0.05). In the intermuscular group, the cervical ROM were significantly improved at 3, 6, 12 months postoperatively and at the final follow-up when compared to those preoperatively and showed further improvement over time ( P<0.05). In the posterior midline group, the cervical ROM were significantly improved at 3, 6, 12 months postoperatively and at the final follow-up when compared to those preoperatively ( P<0.05), showing significant decreases at 6, 12 months postoperatively and at the final follow-up from that at 3 months postoperatively ( P<0.05), significant decreases at the final follow-up from those at 6, 12 months postoperatively ( P<0.05), and no significant difference at 12 months postoperatively from that at 6 months postoperatively ( P>0.05). The ASIA grades showed no significant difference between the two groups preoperatively, at 3, 12 months postoperatively and at the final follow-up ( P>0.05) , but were gradually improved over time in both groups ( P<0.05). The postoperative complication rate was 9%(6/70) in the intermuscular group, significantly lower than 48%(31/65) in the posterior midline group ( P<0.01). Conclusion:Compared to the posterior midline approach, the intermuscular approach for laminoplasty in patients with SCIWORA possesses advantages, including shorter operative time and length of hospital stay, reduced intraoperative blood loss and postoperative drainage, less postoperative neck disability, higher daily life quality, better long-term preservation of cervical lordosis and motion, and a lower complication rate.
10.Comparative efficacy of navigation system and orthopedic robot-assisted nail placement in the treatment of lower cervical fracture and dislocation
Xinnan CHENG ; Shuai LI ; Jiaojiao BAI ; Qingda LI ; Yukuan LEI ; Lei ZHU ; Zhen CHANG ; Zhigang ZHAO ; Yunfei HUANG ; Mingzhe FENG ; Liang YAN ; Hua HUI ; Lingbo KONG ; Baorong HE
Chinese Journal of Trauma 2025;41(2):148-156
Objective:To compare the clinical efficacy of navigation system and orthopedic robot-assisted nail placement in the treatment of lower cervical fracture and dislocation.Methods:A retrospective cohort study was conducted to analyze the clinical data of 49 patients with fracture and dislocation of the lower cervical spine who were admitted to Honghui Hospital, Xi′an Jiaotong University School of Medicine from May 2021 to October 2022, including 38 males and 11 females, aged 29-61 years [(39.3±7.3)years]. Injury segments involved C 3 in 12 patients, C 4 in 11, C 5 in 8, C 6 in 9 and C 7 in 9. Twenty-one patients were treated with S8 navigation system (navigation group, 84 screws), and 28 with TINAVI orthopedic robot (robot group, 112 screws). The two groups were compared in terms of the total surgical duration, single screw placement time, total screw placement time, distance between the screw and the anterior cortex, incision length, intraoperative radiation dose, intraoperative blood loss and length of hospital stay. The height of intervertebral space, Cobb angle, sliding distance between vertebral bodies and American Spinal Injury Association (ASIA) grade were assessed before surgery and at 3 days after surgery. Visual analogue scale (VAS), Japanese Orthopedic Association (JOA) score and neck dysfunction index (NDI) before surgery, at 3 days, 3 months after surgery and at the last follow-up were compared. The accuracy of screw placement, intraoperative invasion rate of adjacent facet joints and rate of postoperative complications (infection, screw loosening, etc.) were evaluated. Results:All the patients were followed up for 12-16 months [(13.6±1.9)months]. In the navigation group, the total surgical duration, distance from the screw to the anterior cortex and the intraoperative radiation dose were (236.2±30.6)minutes, (2.0±0.2)mm and (374.3±90.3)mGy respectively, which were significantly shorter or less than those in the robot group [(278.4±20.7)minutes, (10.6±2.9)mm and (448.4±77.9)mGy] ( P<0.01). The single screw placement time, total screw placement time, incision length and intraoperative blood loss were (3.5±0.4)minutes, (23.9±0.5)minutes, (9.1±2.4)cm and (422.2±30.4)ml respectively, which were significantly longer or more than those in the robot group [(2.6±0.2)minutes, (17.9±0.7)minutes, (6.6±2.6)cm and (360.3±56.3)ml] ( P<0.01). There was no significant difference in the length of hospital stay between the two groups ( P>0.05). No significant differences were observed in the height of the intervertebral space, Cobb angle, sliding distance between the vertebral bodies and ASIA grade between the two groups ( P>0.05). At 3 days after surgery, the height of intervertebral space, Cobb angle, sliding distance between vertebral bodies and ASIA grade in both groups were significantly improved when compared with those before surgery ( P<0.05 or 0.01). There were no significant differences in VAS, JOA scores or NDI between the two groups before surgery, at 3 days, 3 months after surgery and at the last follow-up ( P>0.05). The VAS, JOA scores and NDI in both groups were gradually improved at 3 days, 3 months and at the last follow-up after surgery when compared with those before surgery ( P<0.05). There was no significant difference in the accuracy of screw placement of levels 0 and 0+1 between the two groups ( P>0.05). No significant difference in the intraoperative invasion rate of adjacent facet joints between the two groups was found ( P>0.05). There were no serious complications such as infection or screw loosening after surgery in both groups. Conclusions:For lower cervical fracture and dislocation, although there are more advantages in total surgical duration, screw holding force and radiation control regarding the navigation system, and more outstanding performance in screw placement efficiency, incision length and intraoperative blood loss regarding the orthopedic robot, both of them can effectively rebuild the cervical structure, improve neurological function, relieve postoperative pain, improve screw placement accuracy and reduce facet joint injury and serious complications. Selection of the best auxiliary screw placement system should comprehensively consider patients′ conditions and the experience of the surgical team.

Result Analysis
Print
Save