1.Effect of maxillary sinus morphology on the safety of hydraulic sinus floor elevation: a three-dimensional finite element analysis
LIN Xi ; QUE Guoying ; LIU Jia ; ZHOU Zhen ; ZHENG Xianghuai
Journal of Prevention and Treatment for Stomatological Diseases 2026;34(6):556-564
Objective:
To investigate the influence of sinus morphology on the safety of hydraulic sinus floor elevation surgery and provide a biomechanical basis for clinical treatment.
Methods:
After approval by the Medical Ethics Committee of the institution, cone beam computed tomography imaging data from nine patients were collected. The sinus morphologies were classified into slope, flat and concave types. Three-dimensional finite element models of maxillary sinuses with the aforementioned morphologies were constructed using Mimics, Geomagic, Solidworks, and ANSYS software, followed by a simulation of the hydraulic elevation process. The sinus membrane elevation height was set at 1-6 mm. The pressure required for elevation and the equivalent, compressive, tensile, and shear stresses generated on the sinus membrane were recorded and analyzed. The equivalent stress distribution on the sinus membrane was visualized using contour plots.
Results:
The elevation pressure and the equivalent, compressive, tensile, and shear stresses generated on the sinus membrane increased along with the elevation height. When the sinus membrane was lifted to 6 mm, the elevation pressure was (301.17 ± 98.1) kPa, (151.85 ± 3.7) kPa, and (149.36 ± 10.31) kPa in the slope, flat and concave finite element analysis models, respectively. The equivalent stress was (1 023.86 ± 201.99) kPa in the slope sinuses, comparing with (687.91 ± 69.08) kPa and (698.27 ± 96.09) kPa in the flat and concave sinuses. Higher elevation pressure and the equivalent stress, compressive stress and shear stress values were found in the slope sinus than in the flat and concave sinuses under the same elevation height (P < 0.05). Stress distribution analysis revealed that stress was uniformly distributed in the flat sinuses, followed by concave sinuses, but asymmetrically distributed in the slope sinuses
Conclusions
The slope sinuses demonstrated inferior safety and efficiency compared with the flat and concave sinuses when performing hydraulic sinus floor elevation surgery.
2.The first record of Anopheles messeae (Diptera: Culicidae) parasitized by water mites in China
Xue-ru CHEN ; Wen-zhen YAO ; Yu-hao LI ; Gui-chang LI ; Tao MENG ; Qun-ling FENG ; Xin-hui LIU ; Li-hong QIAO ; Xiang-ting WU ; Xue-feng ZHANG ; Cheng-lin LI ; Xue-cheng DONG ; Da-wei WANG ; Xiao-yan SI ; Yu-hong GUO
Acta Parasitologica et Medica Entomologica Sinica 2026;33(1):53-57
Objective This study reports on the obligatory parasitism of water mites Arrenurus sp. on Anopheles messeae at the Manzhouli Port, Inner Mongolia, China. Methods Duing July 2024, a survey on the mosquito diversity was conducted at the Manzhouli Port. Captured mosquitoes and their ectoparasites were identified to species level. Results A total of 1840 adult mosquitoes were collected, representing species from three genera: Culex(Cx. modestus, Cx. pipiens pallens), Aedes(Ae. dorsalis, Ae. flavidorsalis, Ae. flavescens), and Anopheles (An. messeae). Among all the mosqutioes specimens,3 out of 150 captured An. messeae were found to carry ectoparasitic mites, with number of 2,4,27 mites separately. Morphological and molecular identification reached the same result as water mites(Hydrachnidiae, Hydracrina). COI gene sequence showed 94% similarity with the closest species Arrenurus truncatellus. Conlusions Literature review suggests water mites are host-specific parasitism of mosquito species and herein with the first record of Arrenurus sp. parasiting on An. Messeae in the most high-latitude region globally.
3.Optimization Study of Rat Models for Sequelae of Pelvic Inflammatory Disease
Zhen LIU ; Wei-ling WANG ; Yun-cheng MA ; Yu-xi WANG ; Yuan TIAN ; Qian LI ; Xiao-zhu WANG ; Xiao-yao LIU ; Mei JIANG ; Wen-hui XU ; Jian GAO ; Ting WANG
Progress in Modern Biomedicine 2025;25(12):1921-1930
Objective:To establish a stable rat model of sequelae of pelvic inflammatory disease(SPID)with clinical characteristics,and to provide a reliable experimental model for the study of the pharmcological effect and mechanism of SPID.Methods:Twenty-four 7-week-old SD rats were divided into sham operation group,model-A(108 cfu/mL mixed bacterial solution,0.2 mL),model-B(109 cfu/mL mixed bacterial solution 0.2 mL),and model-C(108 cfu/mL E.coli 0.2 mL).The weight of the rat's uterine was weighed and the uterine index was calculated.The automatic hematology analyzer was used to detect the blood routine;hematoxylin-eosin staining(HE)and masson staining were used to detect uterine pathlogical changes in rats.Enzyme-linked immunosorbent assay(ELISA)was used to detect interleukin-1β(IL-1β),interleukin-6(IL-6)and tumor necrosis factor-α(TNF-α)in rat uterine tissue homogenates.Western blot was used to detect the expression of proteins related to NF-κB signaling pathway.Results:Compared with the sham operation group,the uterine index of model-A,model-B,and model-C were significantly increased(P<0.05,P<0.01).The levels of WBC and NE in the model-A increased significantly(P<0.01).The level of LY in model-B decreased significantly(P<0.01).The levels of IL-1β,TNF-α in model-A,model-B,and model-C were significantly increased(P<0.01).The levels of IL-6 in model-A and model-B were significantly increased(P<0.05,P<0.01).The collagen volume fraction of model-A and model-B were significantly increased(P<0.01).Mechanism study indicates that the expression levels of p-IKKβ/IKKβ,p-IκBα/IκBα and p-p65/p65 in model-A were significantly increased(P<0.01),and the expression levels of IκBα/β-actin were significantly decreased(P<0.01).The expression level of p-IKKβ/IKKβ in model-B was significantly increased(P<0.01).Conclusions:A stable rat model of SPID that conforms to clinical characteristics can be successfully constructed by combining 0.2 mL of mixed bacterial solution with a concentration of 108 cfu/mL and mechanical injury.This modeling method intervened in the expression of the NF-κB inflammatory signaling pathway.
4.Effect of Qishen Yixin Granules on microcirculatory endothelial dysfunction induced by Ang Ⅱ and high-fat diet in mice and its mechanism
Wen-fang JIN ; Zhen-ni ZHANG ; Tian-tian ZHU ; Hu-gang JIANG ; Xin-qiang WANG ; Chun-zhen REN ; Xi-ping XING ; Kai LIU ; Ying-dong LI ; Xin-ke ZHAO
Chinese Pharmacological Bulletin 2025;41(10):1982-1990
Aim To clarify the mechanism by which Qishen Yixin Granules improved microcirculation vas-cular endothelial dysfunction(VED)in mice,through activating the Nrf2/HO-1 signaling pathway to regulate oxidative stress.Methods C57 mice were randomly divided into six groups:blank group,model group,pos-itive drug group,and low-,medium-,and high-dose groups of Qishen Yixin Granules.The VED model was established by long-term infusion of Ang Ⅱ combined with a high-fat diet.Each treatment group received the corresponding drug intervention.After four weeks of drug intervention,cardiac function was assessed by echocardiography.Carstairs staining was used to ob-serve the formation of microthrombi in myocardial tis-sue.The micro vascular ischemia was evaluated by Hei-denhain staining.The ultrastructure of endothelial cells was observed by electron microscopy.The levels of EMPs,ROS,NO,ET-1,TF,TM,VWF,and TXA2 in serum were measured by ELISA.The expression levels of MDA,SOD,and GSH-Px in mouse heart tissue were determined by chemical methods.Cardiac microvascu-lar density and the expression of Nrf2,Keap1,and HO-1 proteins were detected by Immunohistochemical stai-ning.The protein expressions of Keap1,cytoplasmic Nrf2,nuclear Nrf2,and HO-1 in myocardial tissue were detected by Western blot.Results Qishen Yixin Granules could effectively improve the cardiac function of mice,alleviate the damage of endothelial cells and endothelial function.They could up-regulate serum NO levels and the activities of antioxidant enzymes SOD and GSH-Px,while down-regulating the expression of ROS and vascular inflammatory injury factors such as ET-1,VWF,TXA2,TF,TM,and EMPs.Qishen Yixin Granules also increased the positive counts of CD34,Nrf2,and HO-1,as well as microvessel density.Fur-thermore,they inhibited the expression of MDA,Keap1,and cytoplasmic Nrf2 protein in myocardial tis-sue,while increasing the expression of nuclear proteins HO-1 and Nrf2.Conclusions Qishen Yixin Granules may inhibit oxidative stress and inflammatory response by regulating the Nrf2/HO-1 signaling pathway,thereby improving vascular endothelial damage and cardiac function in VED mice.
5.Optimization Study of Rat Models for Sequelae of Pelvic Inflammatory Disease
Zhen LIU ; Wei-ling WANG ; Yun-cheng MA ; Yu-xi WANG ; Yuan TIAN ; Qian LI ; Xiao-zhu WANG ; Xiao-yao LIU ; Mei JIANG ; Wen-hui XU ; Jian GAO ; Ting WANG
Progress in Modern Biomedicine 2025;25(12):1921-1930
Objective:To establish a stable rat model of sequelae of pelvic inflammatory disease(SPID)with clinical characteristics,and to provide a reliable experimental model for the study of the pharmcological effect and mechanism of SPID.Methods:Twenty-four 7-week-old SD rats were divided into sham operation group,model-A(108 cfu/mL mixed bacterial solution,0.2 mL),model-B(109 cfu/mL mixed bacterial solution 0.2 mL),and model-C(108 cfu/mL E.coli 0.2 mL).The weight of the rat's uterine was weighed and the uterine index was calculated.The automatic hematology analyzer was used to detect the blood routine;hematoxylin-eosin staining(HE)and masson staining were used to detect uterine pathlogical changes in rats.Enzyme-linked immunosorbent assay(ELISA)was used to detect interleukin-1β(IL-1β),interleukin-6(IL-6)and tumor necrosis factor-α(TNF-α)in rat uterine tissue homogenates.Western blot was used to detect the expression of proteins related to NF-κB signaling pathway.Results:Compared with the sham operation group,the uterine index of model-A,model-B,and model-C were significantly increased(P<0.05,P<0.01).The levels of WBC and NE in the model-A increased significantly(P<0.01).The level of LY in model-B decreased significantly(P<0.01).The levels of IL-1β,TNF-α in model-A,model-B,and model-C were significantly increased(P<0.01).The levels of IL-6 in model-A and model-B were significantly increased(P<0.05,P<0.01).The collagen volume fraction of model-A and model-B were significantly increased(P<0.01).Mechanism study indicates that the expression levels of p-IKKβ/IKKβ,p-IκBα/IκBα and p-p65/p65 in model-A were significantly increased(P<0.01),and the expression levels of IκBα/β-actin were significantly decreased(P<0.01).The expression level of p-IKKβ/IKKβ in model-B was significantly increased(P<0.01).Conclusions:A stable rat model of SPID that conforms to clinical characteristics can be successfully constructed by combining 0.2 mL of mixed bacterial solution with a concentration of 108 cfu/mL and mechanical injury.This modeling method intervened in the expression of the NF-κB inflammatory signaling pathway.
6.Study on different test methods to evaluate the drying effect of flexible endoscope
Xianhuang LI ; Ziyi HUANG ; Liuji CHEN ; Jing ZHEN ; Haixia LIU ; Yanxia ZHANG ; Xun ZHANG ; Xi HUANG ; Jiuhong MA
China Journal of Endoscopy 2025;31(11):34-39
Objective To compare the effectiveness of cobalt chloride test papers and borescope in evaluating the drying of endoscopes,providing a reference for clinical selection of appropriate assessment tools.Methods 10 gastroscopes and 10 colonoscopes procedures were selected from November 2023 to March 2024 for circulation experiments.After endoscope reprocessing,they were randomly divided into five groups with different drying times(30 s,3 min,6 min,9 min,and 12 min)with 200 samples.Cobalt chloride test paper and borescope were used to evaluate the drying effectiveness.Results The qualified rate of gastrointestinal endoscope by borescope was significantly higher than that by cobalt chloride test paper,but cobalt chloride test paper was obviously better than that by borescope in convenience and cost-effectiveness.The borescope had the function of visualization,and the quantitative positioning observation of residual droplets showed that there were a large number of droplets left after gastrointestinal endoscope drying for 30 s,and the number of droplets was obviously reduced after drying for 3 min.Among them,the gastroscope was mainly light(1~5 drops/strip)and none(0 drops/strip),and the colonoscope was mainly moderate(6~10 drops/strip)and light droplets.Compared with different drying times,there was a significant statistical difference in the number of residual droplets in the endoscope(P<0.01),and the localized droplets mainly remained in the distal bending part and the proximal bifurcation part of the lumen.Conclusion Both cobalt chloride test papers and borescope are important methods for assessing endoscope drying efficacy,each with its own advantages and limitations.Clinicians can use both methods in combination to comprehensively evaluate the overall dryness of endoscopes,thereby ensuring the safety and effectiveness of the endoscope reprocessing process.
7.Monitoring of bacterial contamination of water specimens at different pre-discharge time of flexible endoscopic final rinse water before daily use:a multicenter study
Jing ZHEN ; Liuji CHEN ; Yangyang ZHANG ; Ziyi HUANG ; Haixia LIU ; Xianhuang LI ; Xi HUANG ; Jiuhong MA
Chinese Journal of Infection Control 2025;24(2):236-241
Objective To investigate the bacterial contamination of water specimens at different pre-discharge time of flexible endoscopic final rinse water before daily use,and provide reference basis for choosing the optimal pre-dis-charge time in clinical work.Methods From August to December 2023,the water produced by the purified water equipment of the digestive endoscopy centers of 4 tertiary first-class medical institutions in Jiangxi Province,as well as the final rinsing water at the terminal-point at different pre-discharge times(before pre-discharge,discharge of 1,3,5,and 10 minutes)were subjected to on-site sampling,the collected water specimens were performed microbio-logical cultures by pouring and filter membrane methods,unqualified water specimens were performed bacterial i-dentification.Results 48 specimens of water produced by purified water equipment were collected,with qualified rate of 100%.480 final water specimens were collected,with a qualified rate of 0 before pre-discharge.The quali-fied rates of pre-discharge at 1,3,5,and 10 minutes were 0,21.88%,55.21%,and 73.96%,respectively.Bac-terial colony counts in the final rinse water with different pre-discharge times in 4 medical institutions showed statis-tically significant differences(all P<0.001).As the pre-discharge time increased,bacterial colony counts in the fi-nal rinse water of all four medical institutions showed a decreasing trend.The pairwise comparison of the overall bacterial colony count of the final rinse water at different pre-discharge time showed that there was no statistically significant difference in the bacterial colony count of the final rinse water at 5 and 10 minutes of pre-discharge(P>0.05),while the pairwise comparison between other time points showed statistically significant differences(all P<0.001).Environmental contaminated bacteria such as Micrococcus luteus,Cupriavidus paucula,and Sphin-gononas paucimobilis were detected from the unqualified water specimens.Conclusion With the extension of pre-discharge time,the degree of bacterial contamination in the final rinse water significantly decreases.All levels of medical institutions need to pre-discharge the final rinse water daily,and the pre-discharge time should last for at least 5 minutes.
8.Effect of Qishen Yixin Granules on microcirculatory endothelial dysfunction induced by Ang Ⅱ and high-fat diet in mice and its mechanism
Wen-fang JIN ; Zhen-ni ZHANG ; Tian-tian ZHU ; Hu-gang JIANG ; Xin-qiang WANG ; Chun-zhen REN ; Xi-ping XING ; Kai LIU ; Ying-dong LI ; Xin-ke ZHAO
Chinese Pharmacological Bulletin 2025;41(10):1982-1990
Aim To clarify the mechanism by which Qishen Yixin Granules improved microcirculation vas-cular endothelial dysfunction(VED)in mice,through activating the Nrf2/HO-1 signaling pathway to regulate oxidative stress.Methods C57 mice were randomly divided into six groups:blank group,model group,pos-itive drug group,and low-,medium-,and high-dose groups of Qishen Yixin Granules.The VED model was established by long-term infusion of Ang Ⅱ combined with a high-fat diet.Each treatment group received the corresponding drug intervention.After four weeks of drug intervention,cardiac function was assessed by echocardiography.Carstairs staining was used to ob-serve the formation of microthrombi in myocardial tis-sue.The micro vascular ischemia was evaluated by Hei-denhain staining.The ultrastructure of endothelial cells was observed by electron microscopy.The levels of EMPs,ROS,NO,ET-1,TF,TM,VWF,and TXA2 in serum were measured by ELISA.The expression levels of MDA,SOD,and GSH-Px in mouse heart tissue were determined by chemical methods.Cardiac microvascu-lar density and the expression of Nrf2,Keap1,and HO-1 proteins were detected by Immunohistochemical stai-ning.The protein expressions of Keap1,cytoplasmic Nrf2,nuclear Nrf2,and HO-1 in myocardial tissue were detected by Western blot.Results Qishen Yixin Granules could effectively improve the cardiac function of mice,alleviate the damage of endothelial cells and endothelial function.They could up-regulate serum NO levels and the activities of antioxidant enzymes SOD and GSH-Px,while down-regulating the expression of ROS and vascular inflammatory injury factors such as ET-1,VWF,TXA2,TF,TM,and EMPs.Qishen Yixin Granules also increased the positive counts of CD34,Nrf2,and HO-1,as well as microvessel density.Fur-thermore,they inhibited the expression of MDA,Keap1,and cytoplasmic Nrf2 protein in myocardial tis-sue,while increasing the expression of nuclear proteins HO-1 and Nrf2.Conclusions Qishen Yixin Granules may inhibit oxidative stress and inflammatory response by regulating the Nrf2/HO-1 signaling pathway,thereby improving vascular endothelial damage and cardiac function in VED mice.
9.Application and management status of automated endoscope reprocessors in 292 medical institutions
Jin ZHEN ; Liuji CHEN ; Haixia LIU ; Jiuhong MA ; Xianhuang LI ; Xi HUANG
Chinese Journal of Infection Control 2025;24(9):1278-1285
Objective To understand the current status of application,management,and maintenance of automa-ted endoscope reprocessors(AERs)in China.Methods A questionnaire survey was conducted using convenience sampling method on the application,management,maintenance,and monitoring of AERs,as well as personnel training in digestive endoscopy centers of 292 medical institutions(MIs).Results A total of 316 questionnaires were distributed,and 292 were available,with an effective response rate of 92.41%.Among the 292 MIs,198(67.81%)were equipped with AERs,with equipment rates of 75.11%in tertiary MIs and 41.27%in secondary MIs.88.38%of MIs performed manual cleaning before placing endoscopes into AERs,while 2.02%of MIs still didn't perform this step,mainly in tertiary MIs.The most common problems in the application of AERs were the detachment or damage of connecting pipes(83.33%),followed by disinfectant leakage of AERs(43.94%),mal-function of control panel(43.94%),and failure or poor water flow of AER pipeline(42.93%).92.42%of MIs regularly disinfected AERs,72.73%of MIs regularly replaced AER air filters,and 80.30%of MIs regularly re-placed AER water filters.96.46%of MIs monitored the concentration of disinfectants before daily application of AERs,87.88%of MIs regularly monitored the final rinse water of AERs,and 96.97%of MIs provided professio-nal training for new employees to use AERs for the first time.Conclusion The equipping rate of AERs at all levels of MIs in China still needs to be improved.Most MIs are able to monitor and maintain AERs well,but there are still many problems in the application process.Due to the large volume of endoscopic diagnosis and treatment as well as insufficient execution rate of manual cleaning in tertiary MIs,it is necessary to optimize workflow and strengthen training.Secondary MIs face challenges such as equipment shortages and low monitoring execution rates,requiring increased funding and regulatory efforts.It is recommended that manufacturers continuously optimize AER design,MIs establish standardized AER application protocol,and relevant departments improve AER application and ma-nagement standards,in order to improve the quality of endoscopic cleaning and disinfection and ensure patient safety during diagnosis and treatment.
10.Key technology and equipment development status of first-aid robotics
Zhen-bao WANG ; Zi-jian WANG ; Xin-xi XU ; Xin LIU ; Tao CHENG ; Pei-peng LIU ; Xiu-guo ZHAO ; Chen SU
Chinese Medical Equipment Journal 2025;46(3):96-114
The development status of the key technologies of first-aid robotics was introduced in autonomous system,embo-died intelligence,digital twins,large artificial intelligence model and autonomous unmanned medical treatment.The present situation in first-aid robotics equipment was reviewed for first-aid diagnosis,treatment,assistance and transportation.The development trends of the key technology and equipment of first-aid robotics were analyzed.It was pointed out the involve-ment of big model-based embodied intelligence technology and digital twins technology in first aid might provide new pers-pectives for the application and advancement of specialized first-aid robotics.[Chinese Medical Equipment Journal,2025,46(3):96-114]


Result Analysis
Print
Save
E-mail