4.Application of OpenSim musculoskeletal model in biomechanics research of orthopedics and traumatology.
Rui LI ; Yang LIU ; Zhao-Jie ZHANG ; Xin-Wei ZHANG ; Yan-Zhen ZHANG ; Yan-Qi HU ; Can YANG ; Shu-Shi MAO ; Jia-Ming QIU
China Journal of Orthopaedics and Traumatology 2025;38(3):319-324
OpenSim is an open source, free motion simulation and gait analysis software, which can be used to dynamically simulate and analyze the complex motion of the human body, and is widely used in human biomechanical research. Since OpenSim can analyze multi-dimensional motion data such as muscle strength, joint torque, and muscle synergistic activation during human movement, it can be used to study the biomechanical mechanism of musculoskeletal imbalance diseases and various treatment methods in TCM orthopedics, and has a broad application prospect in the field of TCM orthopedics. By the analysis of the basic characteristics, elements, analysis process, and application prospects of OpenSim, it is concluded that OpenSim musculoskeletal model has a large application space in the field of traditional Chinese medicine orthopedic, which is helpful to explain the pathogenesis and mechanism of diseases, and promote the precision diagnosis and treatment of orthopedics diseases;the application of OpenSim musculoskeletal model can solve the problem that the previous research paid attention to the bone malalignment and not enough attention to the tendon, and provide a new method for the research of orthopedic diseases. At present, there are still problems in the promotion and application of OpenSim, such as large equipment requirements and high operation threshold. Therefore, multidisciplinary cooperation, clinical research, and data sharing are the basic research strategies in this field.
Humans
;
Biomechanical Phenomena
;
Orthopedics
;
Traumatology
;
Software
;
Medicine, Chinese Traditional
;
Musculoskeletal System
;
Models, Biological
5.Comparative study on lengthened proximal femoral nail antirotation and InterTan in the treatment of subtrochanteric femur fractures in the elderly.
Zhen-Shan WANG ; Ming-Cong DING ; Jin JIANG ; Jing-Sheng LIU ; Tong-Qun YANG
China Journal of Orthopaedics and Traumatology 2025;38(7):662-667
OBJECTIVE:
To investigate the clinical efficacy of lengthened proximal femoral nail antirotation (PFNA) and InterTan in the treatment of subtrochanteric femur fractures in the elderly.
METHODS:
A retrospective analysis was performed on the data of 65 elderly patients diagnosed with subtrochanteric femoral fractures who met the inclusion criteria between October 2016 and January 2022. The enrolled patients were categorized into two groups according to the type of internal fixation used: the lengthened proximal femoral nail antirotation(PFNA) group and the InterTan group. There were 32 patients in the PFNA group, comprising 20 males and 12 females, with ages ranging from 60 to 85 years old with an average of (69.3±6.7 ) years old. Among these patients, 15 patients resulted from traffic accidents and 17 patients were caused by falls. According to the Seinsheimer classification system, there were 11 patients as type Ⅱ, 14 patients as type Ⅲ, 6 patients as type Ⅳ, and 1 patient as type Ⅴ. The InterTan group comprised 33 patients, including 20 males and 13 females, aged from 60 to 85 years old with an average of (69.8±7.8 ) years old. Of these, 15 patients resulted from traffic accidents, while 18 patients were caused by falls. According to the Seinsheimer classification system, 10 patients as type Ⅱ, 15 patients as type Ⅲ, 7 patients as type Ⅳ, and 1 patient as type Ⅴ. The intraoperative blood loss, operative duration, and fracture healing time were recorded and compared between two groups. The quality of fracture reduction was assessed using Chang's criteria. Additionally, the Harris hip score was utilized to evaluate hip function in both groups at 3 months postoperatively and at the final follow-up.
RESULTS:
All patients were followed up for a period ranging from 10 to 20 months with an average of (14.6±4.5) months. No statistically significant differences were observed between two groups in terms of operation time, intraoperative blood loss, quality of fracture reduction, or reduction methods (P>0.05). Three months after the surgery, the Harris hip score in the InterTan group was 80.0(78.0, 83.5) points, which was significantly higher than that in the PFNA group, which recorded a score of 77.5(75.0, 81.8) points. This difference was statistically significant (P<0.05). At the final follow-up, the Harris hip score in the InterTan group was 80.0(76.5, 87.0), while that in the PFNA group was 78.0(74.3, 82.8). No statistically significant difference was observed between two groups (P>0.05).
CONCLUSION
The use of lengthened PFNA and InterTan in the treatment of elderly subtrochanteric femur fractures can both achieve good treatment results, with the advantages of simple operation, firm fixation, and low failure rate of internal fixation. The lengthened InterTan can achieve better hip function than PFNA.
Humans
;
Male
;
Female
;
Aged
;
Aged, 80 and over
;
Bone Nails
;
Retrospective Studies
;
Hip Fractures/surgery*
;
Middle Aged
;
Fracture Fixation, Intramedullary/instrumentation*
;
Fracture Fixation, Internal/methods*
;
Femoral Fractures/surgery*
6.Comparative experimental study on the biomechanical properties of retrograde tibial nailing and distal tibia L-shaped plate in distal tibia fracture.
Xu-Ping LIN ; Qing-Jun LIU ; Sheng-Gui XU ; Cong ZHANG ; Ming-Ming GAO ; Zhen-Qi DING ; Bin LIN
China Journal of Orthopaedics and Traumatology 2025;38(7):737-742
OBJECTIVE:
To investigate the biomechanical characteristics of retrograde tibial nailing (RTN) and distal tibial L-shaped plating in the internal fixation of distal tibial fractures.
METHODS:
Fourteen fresh adult tibia specimens were selected, comprising 7 males and 7 females aged from 34 to 55 years old. The specimens were randomly divided into experimental group and control group by numerical table method with 7 specimens in each group. RTN was used for internal fixation of distal tibial fractures in the experimental group, and L-shaped plate was used for internal fixation of distal tibial fractures in the control group. The axial compression properties of the two groups of specimens were tested under the pressure of 100, 200, 300, 400, and 500 N after operation, and torsional resistance at torque levels of 1.0, 2.0, 3.0, 4.0, 5.0 N·m. The anti-fatigue performance of the specimens was tested at 500 N pressure for 3 000 and 10 000 cycles. X-ray fluoroscopy was performed to observe whether the the internal fixator was deformed and whether the screw was loosened or broken.
RESULTS:
When the pressure was 400 N and 500 N, the axial compression displacement of the experimental group was (1.11±0.06) mm and (1.24±0.05) mm, which were smaller than those of the control group (1.21±0.08) mm and (1.37±0.11) mm, and the differences were statistically signific (P<0.05). Under the pressure of 500 N, the axial compression stiffness of the experimental group was (389.24±17.79) N·mm-1, which was significantly higher than that of the control group (362.37±14.44) N·mm-1(P<0.05). When the torque was 4 and 5 N·m, the torsion angles of the experimental group were (2.97±0.23) ° and (3.41±0.17) °, which were smaller than those of the control group (3.31±0.28) ° and (3.76±0.20) °, and the differences were statistically significant (P<0.05). When the torque was 5 N·m, the torsional stiffness of the experimental group was (1.48±0.07) N·m per degree, which was higher than that of the control group (1.36±0.06) N·m per degree, and the difference was statistically significant (P<0.05). For the intragroup comparison of fatigue resistance, the differences in axial compression displacement between the two groups were not statistically significant at 3 000 and 10 000 cycles (all P>0.05). When 3 000 times and 10 000 times of compression, the axial compression displacement of the experimental group was (1.38±0.08), (1.43±0.07) mm, which was smaller than that of the control group (1.51±0.10), (1.54±0.08) mm, the differences were statistically significant (P<0.05). In the experimental group, no screw loosening, fracture or internal fixation deformation was found, while in the control group, locking screw loosening occurred in 2 models after 10 000 pressures.
CONCLUSION
The biomechanical performance of RTN is obviously better than that of the distal tibial L-shaped plate, which provides biomechanical data support for the clinical application of RTN.
Humans
;
Female
;
Male
;
Adult
;
Tibial Fractures/physiopathology*
;
Middle Aged
;
Biomechanical Phenomena
;
Bone Plates
;
Fracture Fixation, Internal/instrumentation*
;
Bone Nails
;
Tibia/surgery*
7.Research of injury mapping relationship of lumbar spine in reclined occupants between anthropomorphic test devices and human body model.
Yu LIU ; Jing FEI ; Xin-Ming WAN ; Pei-Feng WANG ; Zhen LI ; Xiao-Ting YANG ; Lin-Wei ZHANG ; Zhong-Hao BAI
Chinese Journal of Traumatology 2025;28(2):130-137
PURPOSE:
To judge the injury mode and injury severity of the real human body through the measured values of anthropomorphic test devices (ATD) injury indices, the mapping relationship of lumbar injury between ATD and human body model (HBM) was explored.
METHODS:
Through the ATD model and HBM simulation, the mapping relationship of lumbar injury between the 2 subjects was explored. The sled environment consisted of a semi-rigid seat with an adjustable seatback angle and a 3-point seat belt system with a seatback-mounted D-ring. Three seatback recline states of 25°, 45°, and 65° were designed, and the seat pan angle was maintained at 15°. A 23 g, 47 km/h pulse was used. The validity of the finite element model of the sled was verified by the comparison of ATD simulation and test results. ATD model was the test device for human occupant restraint for autonomous vehicles (THOR-AV) dummy model and HBM was the total human model for safety (THUMS) v6.1. The posture of the 2 models was adjusted to adapt to the 3 seat states. The lumbar response of THOR-AV and the mechanical and biomechanical data on L1 - L5 vertebrae of THUMS were output, and the response relationship between THOR-AV and THUMS was descriptive statistically analyzed.
RESULTS:
Both THOR-AV and THUMS were submarined in the 65° seatback angle case. With the change of seatback angle, the lumbar spine axial compression force (Fz) of THOR-AV and THUMS changed in the similar trend. The maximum Fz ratio of THOR-AV to THUMS at 25° and 45° seatback angle cases were 1.6 and 1.7. The flexion moment (My) and the time when the maximum My occurred in the 2 subjects were very different. In particular, the form of moment experienced by the L1 - L5 vertebrae of THUMS also changed. The changing trend of My measured by THOR-AV over time can reflect the changing trend of maximum stress of L1 and L2 of THUMS.
CONCLUSION
The Fz of ATD and HBM presents a certain proportional relationship, and there is a mapping relationship between the 2 subjects on Fz. The mapping function can be further clarified by applying more pulses and adopting more seatback angles. It is difficult to map My directly because they are very different in ATD and HBM. The My of ATD and stress of HBM lumbar showed a similar change trend over time, and there may be a hidden mapping relationship.
Humans
;
Lumbar Vertebrae/injuries*
;
Finite Element Analysis
;
Biomechanical Phenomena
;
Manikins
;
Spinal Injuries/physiopathology*
8.One-year recovery after lateral retinaculum release combined with chondroplasty in patients with lateral patellar compression syndrome.
Zhen-Long LIU ; Yi-Ting WANG ; Jin-Ming LIN ; Wu-Ji ZHANG ; Jiong-Yuan LI ; Zhi-Hui HE ; Yue-Yang HOU ; Jian-Li GAO ; Wei-Li SHI ; Yu-Ping YANG
Chinese Journal of Traumatology 2025;28(6):462-468
PURPOSE:
Lateral patellar compression syndrome (LPCS) is characterized by a persistent abnormally high stress exerted on the lateral articular surface of the patella due to lateral patellar tilt without dislocation and lateral retinaculum contracture, leading to anterior knee pain. The purpose of this study is to evaluate the efficacy and prognosis of lateral retinaculum release (LRR) combined with chondroplasty in the treatment of LPCS.
METHODS:
This retrospective study evaluated 40 patients who underwent LRR combined with chondroplasty for LPCS between 2020 and 2021. The assessment included improvement in postoperative tenderness and knee joint function. Patients were evaluated using the Lysholm, Tegner, and International Knee Documentation Committee 2000 scoring systems, as well as the visual analog scale, both preoperatively and postoperatively, with the paired comparisons analyzed using a t-test. Additionally, intraoperative observations were made regarding knee joint lesions, including cartilage damage and osteophyte formation, with analysis by the Chi-square test.
RESULTS:
The visual analog scale score for tenderness showed a significant decrease after surgery (p < 0.001). Evaluation of knee joint function also indicated significant improvements, as demonstrated by increased Lysholm, Tegner, and International Knee Documentation Committee 2000 scores postoperatively (p < 0.001, p = 0.011, p < 0.001, respectively). Furthermore, all LPCS patients included in the study presented with cartilage injuries and osteophyte formation. Significant differences were noted in the incidence of cartilage damage and osteophyte formation at different locations within the knee among patients with LPCS.
CONCLUSION
LRR combined with chondroplasty is an effective surgical approach for treating patients with LPCS, with satisfactory recovery observed at the 1-year follow-up. Additionally, the incidence of cartilage damage and osteophyte formation in LPCS patients varies significantly depending on the specific location within the knee joint.
Humans
;
Male
;
Female
;
Retrospective Studies
;
Adult
;
Middle Aged
;
Patella/surgery*
;
Knee Joint/physiopathology*
;
Recovery of Function
;
Young Adult
;
Treatment Outcome
;
Cartilage, Articular/surgery*
;
Adolescent
9.Nonlinear association between serum albumin levels and all-cause mortality in elderly patients with chronic aortic regurgitation.
Ming-Hui LI ; Qing-Rong LIU ; Zhen-Yan ZHAO ; Hai-Yan XU ; Yong-Jian WU
Journal of Geriatric Cardiology 2025;22(4):423-432
BACKGROUND:
Low serum albumin levels are established predictors of adverse outcomes in various cardiovascular conditions. However, the role of serum albumin in mortality among elderly patients with chronic aortic regurgitation (AR) has not been thoroughly investigated. This study aims to assess the relationship between serum albumin levels and mortality in this specific patient population.
METHODS:
Our analysis included 873 elderly AR patients from the China Valvular Heart Disease study, with baseline serum albumin measured at enrollment. Mortality outcomes were monitored for two years post-enrollment, employing a Cox proportional hazards model with a two-piecewise Cox proportional hazards framework to investigate the nonlinear relationship between serum albumin levels and all-cause mortality.
RESULTS:
During the 2-year follow-up period, we observed 63 all-cause deaths. The association between serum albumin levels and all-cause mortality displayed an approximating L-shaped curve, indicating a mortality threshold at 35 g/L. For serum albumin levels below 35 g/L, each 1 g/L decrease was associated with a 25% higher risk of all-cause mortality (HR = 1.25, 95% CI: 1.07-1.45). In contrast, no significant change in mortality risk was observed when serum albumin levels were greater than or equal to 35 g/L. Moreover, when serum albumin is classified as hypoproteinemia (serum albumin < 35 g/L), the higher risks of all-cause death were observed in hypoproteinemic patients (HR = 2.93, 95% CI: 1.50-5.74). More importantly, the association between serum albumin and death was significantly stronger in overweight/obese patients (≥ 24 kg/m2 vs. < 24 kg/m2, P interaction = 0.006).
CONCLUSIONS
In elderly patients with AR, serum albumin levels showed an approximating L-shaped relationship with all-cause death, with thresholds of 35 g/L. Body mass index was significant effect modifiers of the association. These results suggest that serum albumin, as an inexpensive and readily available biochemical marker, may further improve the stratified risk of mortality in older AR patients.
10.Current situation of clinical trial registration in acupuncture anesthesia: A scoping review.
Yue LI ; You-Ning LIU ; Zhen GUO ; Mu-En GU ; Wen-Jia WANG ; Yi ZHU ; Xiao-Jun ZHUANG ; Li-Ming CHEN ; Jia ZHOU ; Jing LI
Journal of Integrative Medicine 2025;23(3):256-263
BACKGROUND:
Modern acupuncture anesthesia is a combination of Chinese and Western medicine that integrates the theories of acupuncture with anesthesia. However, some clinical studies of acupuncture anesthesia lack specific descriptions of randomization, allocation concealment, and blinding processes, with subsequent systematic reviews indicating a risk of bias.
OBJECTIVE:
Clinical trial registration is essential for the enhancement of the quality of clinical trials. This study aims to summarize the status of clinical trial registrations for acupuncture anesthesia listed on the World Health Organization International Clinical Trials Registry Platform (ICTRP).
SEARCH STRATEGY:
We searched the ICTRP for clinical trials related to acupuncture anesthesia registered between January 1, 2001 and May 31, 2023. Additionally, related publications were retrieved from PubMed, Cochrane Library, Embase, China National Knowledge Infrastructure, China Science and Technology Journal Database, and Wanfang Data. Registrations and publications were analyzed for consistency in trial design characteristics.
INCLUSION CRITERIA:
Clinical trials that utilized one of several acupuncture-related therapies in combination with pharmacological anesthesia during the perioperative period were eligible for this review.
DATA EXTRACTION AND ANALYSIS:
Data extracted from articles included type of surgical procedure, perioperative symptoms, study methodology, type of intervention, trial recruitment information, and publication information related to clinical enrollment.
RESULTS:
A total of 166 trials related to acupuncture anesthesia from 21 countries were included in the analysis. The commonly reported symptoms in the included studies were postoperative nausea and vomiting (19.9%) and postoperative pain (13.3%). The concordance between the publications and the trial protocols in the clinical registry records was poor, with only 31.7% of the studies being fully compatible. Inconsistency rates were high for sample size (39.0%, 16/41), blinding (36.6%, 15/41), and secondary outcome indicators (24.4%, 10/41).
CONCLUSION
The volume of acupuncture anesthesia clinical trials registered in international trial registries over the last 20 years is low, with insufficient disclosure of results. Postoperative nausea and vomiting as well as postoperative pain, are the most investigated for acupuncture intervention. Please cite this article as: Li Y, Liu YN, Guo Z, Gu ME, Wang WJ, Zhu Y, Zhuang XJ, Chen LM, Zhou J, Li J. Current situation of clinical trial registration in acupuncture anesthesia: A scoping review. J Integr Med. 2025; 23(3): 256-263.
Humans
;
Acupuncture Analgesia
;
Acupuncture Therapy
;
Anesthesia
;
Clinical Trials as Topic
;
Registries

Result Analysis
Print
Save
E-mail