1.Influencing factors for condom use among men who have sex with men
LIU Jing ; ZHU Han ; YIN Jue ; XIA Manman ; LU Yi ; DAI Qing ; GU Chengjie ; LUO Zhen
Journal of Preventive Medicine 2026;38(2):115-118
Objective:
To investigate the status of condom use and its influencing factors among men who have sex with men (MSM), so as to provide a basis for improving condom utilization rates and AIDS prevention and control in this population.
Methods:
From May to October 2024, a snowball sampling method was employed to recruit MSM in Songjiang District, Shanghai Municipality. Self-administered questionnaires were used to collect data on demographic characteristics, AIDS-related knowledge, sexual behaviors, pre-exposure prophylaxis (PrEP) and post-exposure prophylaxis (PEP), and condom use in the past six months. Multivariable logistic regression model was used to analyze the influencing factors for consistent condom use.
Results:
A total of 921 MSM were surveyed, with a median age of 29.00 (interquartile range, 9.00) years. Among them, 697 (75.68%) were aware of AIDS-related knowledge, 826 (89.69%) expressed willingness to use PrEP, and 835 (90.66%) were willing to use PEP. Additionally, 787 (85.45%) MSM reported their age at first homosexual intercourse as ≥18 years, while 519 (56.35%) reported consistent condom use in the past six months. Multivariable logistic regression analysis revealed that MSM who were aware of AIDS-related knowledge (OR=0.582, 95% CI: 0.423-0.801), willing to use PrEP (OR =0.611, 95% CI: 0.385-0.969), and whose age at first homosexual intercourse was <18 years (OR=0.480, 95% CI: 0.330-0.700) were less likely to consistent use condoms.
Conclusion
The proportion of consistent condom use among the MSM remains relatively low, which is primarily associated with AIDS-related knowledge, willingness to use PrEP, and the age at first homosexual intercourse.
2.Measurement and simulation of secondary neutron energy spectra and doses in proton therapy
Yang YAN ; Changsong HOU ; Zhen ZHANG ; Weiguo ZHU
Chinese Journal of Radiological Health 2026;35(1):23-28
Objective To evaluate the radiation dose levels induced by secondary neutrons at different locations inside proton therapy treatment rooms, and analyze the distribution characteristics of neutron energy spectra by combining experimental measurements with simulations, and to provide a theoretical basis and technical support for radiation protection design and management in proton therapy. Methods Multiple representative measurement points were established in the treatment rooms of two hospital-based proton therapy centers. The DIAMON neutron spectrometer was employed to perform in-situ measurements of secondary neutron doses and energy spectra. Three-dimensional simulation models of treatment rooms were constructed using the FLUKA code to simulate the generation and transport of secondary neutrons. Results Measurements showed that the neutron dose was highest near the target region, reaching up to
3.Comparative Analysis of Clinical Efficacy of Traditional Chinese Medicine Manipulative Reduction Combined with Small Splint Fixation Versus Surgical Treatment for Type A Distal Radius Fracture
Yang SHAO ; Zihan WANG ; Jianwei WANG ; Guoda DAI ; Hengyan CUI ; Zhen HUA ; Tingchen ZHU ; Shaoshuo LI ; Jun MAO ; Fenghua CHEN ; Shuai TAO ; Mao WU
Journal of Traditional Chinese Medicine 2026;67(10):1078-1085
ObjectiveTo compare the clinical efficacy of traditional Chinese medicine (TCM) manipulative reduction combined with small splint fixation versus surgical treatment for type A distal radius fracture (DRF) and to explore the factors influencing the choice of treatment. MethodsA multi-center retrospective study was conducted, collecting data from 1237 type A DRF patients treated in 11 hospitals in Jiangsu province from September, 2023 to April, 2025. Among them, 851 patients in the TCM group received manipulative reduction combined with small splint fixation, and 386 patients in the surgical group underwent open reduction and internal fixation. Visual analog scale (VAS) scores for pain and radiographic indicators including palmar tilt, ulnar deviation, and radial height were compared before treatment, 5-7 days after treatment, and 4-6 weeks after treatment. The wrist joint function scores including Dienst and Gartland-Werley scores at 12 weeks after treatment were recorded. Subgroup analysis was conducted for the excellent rate of Dienst and Gartland-Werley scores, stratified by age (<50, 50-59, 60-69, ≥70 years old) and AO subtypes (A1, A2, A3). A multivariate logistic regression model was used to identify independent factors influencing treatment choice. ResultsOn 5-7 days after treatment, the surgical group had lower VAS scores than the TCM group, while 4-6 weeks after treatment, the TCM group showed lower VAS scores than the surgical group (P<0.01). In terms of radiographic indicators, except for the palmar tilt before treatment being higher in the surgical group than in the TCM group (P<0.01), there were no significant differences in palmar tilt, ulnar deviation, and radial height at other timepoints (P>0.05). Twelve weeks after treatment, the surgical group had a higher average Gartland-Werley score and the excellent rate than the TCM group (P<0.01). Subgroup analysis showed that in patients with A2 type DRF aged 50-59 and 60-69 years old, the excellent rates of Dienst and Gartland-Werley scores in the TCM group were higher than those in the surgical group (P<0.05). Multivariate logistic regression analysis revealed that age, palmar tilt, ulnar deviation, and the degree of swelling on the affected side were independent factors influencing the choice of treatment (P<0.05). ConclusionBoth TCM manipulative reduction combined with small splint fixation and surgical treatment for type A DRF can achieve good therapeutic effects. TCM manipulative reduction combined with small splint fixation has certain advantages in medium- and long-term pain relief, especially in elderly patients, where wrist joint function recovery is more stable. Age, palmar tilt, ulnar deviation, and swelling degree are the main factors influencing the treatment choice.
4.Clinical Efficacy and Radiographic Outcomes of Manipulative Reduction Combined with Small Splint Fixation for Distal Radius Fractures:A Retrospective Multicenter Study with Propensity Score Matching
Mao WU ; Guoda DAI ; Yang SHAO ; Shaoshuo LI ; Zhen HUA ; Hengyan CUI ; Tingchen ZHU ; Dipeng LI ; Jintao LIU ; Ming ZHOU ; Peimin WANG ; Liyong ZHANG ; Jianwei WANG
Journal of Traditional Chinese Medicine 2026;67(10):1086-1092
ObjectiveTo observe the clinical efficacy and radiographic outcomes of manipulative reduction combined with small splint fixation in the treatment of distal radius fractures. MethodsThe clinical data of 1051 patients with distal radius fractures were retrospectively collected from five hospitals included in the Jiangsu Diagnosis and Treatment Data Platform for Traditional Chinese Medicine(TCM) Dominant Diseases. Propensity score matching at a 1∶4 ratio was applied, resulting in 580 cases selected for final analysis, which comprised 448 patients in the TCM group(manipulative reduction plus small splint fixation) and 132 in the surgical treatment group(open reduction and internal fixation). Each group was further stratified into type A, B, and C subgroups based on AO fracture classification. Radiographic indicators including palmar tilt, radial inclination, and radial height were compared between groups before treatment and 1 day, 1 week, and 4-6 weeks after treatment, and pain visual analog scale(VAS) scores before treatment and 1 week and 4-6 weeks after treatment were also compared. Wrist joint function was assessed 12 weeks after treatment, using the Dienst wrist function score and the Gartland and Werley(G-W) wrist function score. Additionally, the radiographic indicators at different timepoints and the 12-week wrist function levels were compared between groups across different fracture types. ResultsNo statistically significant difference was observed in radiographic indicators and VAS scores at all timepoints before and after treatment, as well as wrist joint function grades assessed by the Dienst score and the G-W score at 12 weeks after treatment (P>0.05). Compared to those before treatment, both groups showed increased palmar tilt, radial inclination, and radial height 1 week and 4-6 weeks after treatment, and decreased VAS scores (P<0.05). Compared to those 1 week after treatment, both groups showed a decrease in palmar tilt, an increase in radial inclination and radial height, and a reduction in VAS score 4-6 weeks after treatment(P<0.05). In type A and B subgroups, the surgical treatment group had a higher radial inclination than the TCM group 4-6 weeks after treatment, while in the type C subgroup, a higher radial height was shown in the surgical treatment group than in the TCM group 4-6 weeks after treatment(P<0.05). In type C subgroup, there was significant difference between groups in the wrist joint function by G-W scores 12 weeks after treatment(P<0.05). ConclusionManipulative reduction combined with small splint fixation can maintain fracture alignment and alleviate pain in treating distal radius fractures, which achieves therapeutic outcomes comparable to surgical treatment. It is particularly suitable for type A and B fractures and can be considered an effective treatment option for distal radius fractures.
5.Construction and Clinical Validation of a Deep Learning-Based Automatic Measurement Model for Palmar Tilt and Radial Inclination in Distal Radius Fractures
Guoda DAI ; Jianwei WANG ; Mao WU ; Bin KANG ; Yang SHAO ; Hengyan CUI ; Shaoshuo LI ; Tingchen ZHU ; Zhen HUA ; Zhongming SHEN ; Jintao LIU ; Ming ZHOU
Journal of Traditional Chinese Medicine 2026;67(10):1093-1100
ObjectiveTo construct an automatic measurement model for palmar tilt and radial inclination suitable for traditional Chinese medicine (TCM) clinical scenarios, and to validate its accuracy and efficiency in TCM manipulative reduction settings. MethodsData on anteroposterior (AP) and lateral X-rays of distal radius fractures were collected from patients admitted to 18 TCM/ integrated TCM and western medicine hospitals in Jiangsu province between September 1st, 2023, and September 1st, 2024, via the Jiangsu Diagnosis and Treatment Big Data Platform for TCM Dominant Diseases. A medical image segmentation framework based on multi-scale feature fusion and edge-awareness was employed, combined with anatomical knowledge specific to TCM orthopedics, to optimize the feature extraction strategy of an artificial intelligence (AI) model. This framework enabled automatic segmentation of fracture regions and measurement of distal radius palmar tilt and radial inclination. The accuracy of the AI model in measuring radial inclination and volar tilt was validated, and the measurement time and average time gain rate of the AI model were compared to those of manual measurement. ResultsA total of 15,444 AP and lateral X-ray images of distal radius fractures were collected, and were divided into a training set (11,144 images, 5066 AP and 6078 lateral), a validation set (3700 images, 1840 AP and 1860 lateral), and an independent test set (600 images, 300 AP and 300 lateral) after preprocessing. In the measurement of 300 AP X-rays in the independent test set for radial inclination, when the degree error between AI measurement and manual measurement was <3° and <5°, AI measurement accuracy was 83% and 93%, respectively. In 300 lateral X-rays in the test set for palmar tilt, when AI measurements had an error of <3° and <5° compared to manual measurements, corresponding accuracy rate was 78% and 90%, respectively. For 50 X-ray images, AI measurement time was (1.37±0.05) min for radial inclination while manual measurement time was (22.57±2.52) min (P<0.001); in terms of palmar tilt, the AI measurement time was (1.33±0.14) min, shorter than (23.70±2.80) min for manual measurement time (P<0.001). Average time gain rates for manual and AI measurements were 93.93% and 94.39% respectively. ConclusionAn automatic measurement model for palmar tilt and radial inclination in distal radius fractures has been established, enabling more accurate and efficient assessment as well as providing a tool to support the quantitative evaluation of the efficacy of TCM manipulative reduction and large-sample clinical research.
6.Occupational health literacy among key populations in Jinhua City
CHEN Qiang ; GUO Zhen ; ZHU Wei ; HE Xiaoqing ; ZHU Binbin
Journal of Preventive Medicine 2025;37(7):747-750,756
Objective:
To investigate the occupational health literacy (OHL) level and its influencing factors of key populations in Jinhua City, Zhejiang Province, so as to provide a basis for promoting occupational health.
Methods:
The front-line workers of 7 secondary industry enterprises (institutions) and 15 tertiary industry enterprises (institutions) in Jinhua City were selected from April to October 2023 using a stratified random cluster sampling method. Date of gender, age, length of service, and OHL were collected using the National Occupational Health Literacy Monitoring Survey for Key Population Personal Questionnaire. Factors affecting OHL level among key populations were identified using multivariable logistic regression model.
Results:
A total of 3 305 people were investigated, including 1 750 males (52.95%) and 1 555 females (47.05%). The median age and the length of service were 37 (interquartile range, 17) and (interquartile range, 9) years, respectively. The level of OHL was 45.63%. Multivariable logistic regression analysis identified gender (female, OR=1.675, 95%CI: 1.428-1.964), educational level (junior high school, OR=1.499, 95%CI: 1.089-2.063; high school, OR=1.905, 95%CI: 1.361-2.667; junior college, OR=4.065, 95%CI: 2.858-5.782; bachelor degree and above, OR=5.087, 95%CI: 3.597-7.194), personal monthly income (3 000-< 5 000 yuan, OR=1.373, 95%CI: 1.035-1.821; 5 000-<7 000 yuan, OR=1.653, 95%CI: 1.230-2.220; ≥7 000 yuan, OR=1.798, 95%CI: 1.322-2.447) and length of service (2-<6 years, OR=1.265, 95%CI: 1.032-1.551; 6-<11 years, OR=1.517, 95%CI: 1.184-1.943; ≥11 years, OR=1.337, 95%CI: 1.040-1.719) as factors affecting OHL level among key populations.
Conclusions
The OHL level of the key populations in Jinhua City is related to gender, age, education level, personal monthly income, and length of service. It is necessary to strengthen the occupational health education and health promotion of the key populations.
7.Acupuncture combined with thunder-fire moxibustion for low back pain with cold-damp: a randomized controlled trial.
Tao ZHU ; Shilin JIANG ; Yujia ZHANG ; Tiansheng ZHANG ; Zhen GAO ; Jinling MIAO
Chinese Acupuncture & Moxibustion 2025;45(3):312-316
OBJECTIVE:
To observe the clinical efficacy of acupuncture combined with thunder-fire moxibustion in treating low back pain with cold-damp.
METHODS:
Seventy-two patients of low back pain with cold-damp were randomly divided into an observation group (36 cases, 1 case was eliminated) and a control group (36 cases, 1 case dropped out). The control group received acupuncture at Jizhong (GV6), Yaoyangguan (GV3), ashi points, bilateral Shenshu (BL23), Dachangshu (BL25), and Weizhong (BL40) for 30 min daily. The observation group was treated with thunder-fire moxibustion in addition to the same acupuncture regimen as the control group, once daily. Both groups were treated for 6 consecutive days followed by one rest day, for a total duration of 4 weeks. The visual analog scale (VAS) score, Oswestry disability index (ODI) score, Japanese Orthopedic Association (JOA) score, present pain intensity (PPI) score, and serum levels of β-endorphin (β-EP), 5-hydroxytryp tamin (5-HT), and substance P (SP) were compared before and after treatment, and the clinical efficacy was also compared between the two groups.
RESULTS:
Compared before treatment, the VAS scores, ODI scores, PPI scores, and serum levels of 5-HT and SP were decreased (P<0.01), while JOA scores and serum levels of β-EP were increased (P<0.01) in both groups after treatment. The observation group showed lower VAS, ODI, and PPI scores and serum levels of 5-HT and SP than those in the control group (P<0.05), as well as higher JOA score and serum level of β-EP (P<0.05). The total effective rate in the observation group was 94.3% (33/35), higher than 82.9% (29/35) in the control group (P<0.05).
CONCLUSION
Acupuncture combined with thunder-fire moxibustion could effectively alleviate pain and improve lumbar function in patients of low back pain with cold-damp, possibly by regulating β-EP, 5-HT, and SP levels.
Humans
;
Moxibustion
;
Low Back Pain/blood*
;
Male
;
Female
;
Adult
;
Middle Aged
;
Acupuncture Therapy
;
Acupuncture Points
;
Treatment Outcome
;
Combined Modality Therapy
;
beta-Endorphin/blood*
;
Young Adult
;
Aged
8.Does Vertebral Cement Augmentation Reduce Postoperative Proximal Junction Complications in Spinal Deformity Corrective Surgery: A Systematic Review and Meta-analysis
Dong LI ; Xin SUN ; Jie LI ; Yanjie XU ; Yong QIU ; Zezhang ZHU ; Zhen LIU
Neurospine 2025;22(1):51-66
Objective:
To assess the effectiveness of vertebral cement augmentation (VCA) at upper instrumented vertebra (UIV) and UIV+1 in preventing proximal junction complications in correction surgery for adult spinal deformity patients.
Methods:
A literature search was conducted on Web of Science, PubMed, and Cochrane Library databases for comparative studies published before December 30th, 2024. Two reviewers independently screened eligible articles based on the inclusion and exclusion criteria, assessed study quality with Newcastle-Ottawa scale, and extracted data like study characteristics, surgical details, primary and secondary outcomes. Data analysis was performed using Review Manager 5.4 and Stata software.
Results:
Of all 513 papers screened, a meta-analysis was conducted on 7 articles, which included 333 cases in the VCA group and 827 cases in the control group. Patients in the VCA group had significantly older age and lower T score than patients in the control group. Although there was no statistically significant difference in the incidence of proximal junctional failure between the 2 groups, the results of the meta-analysis showed that the incidence of proximal junctional failure and the need for revision surgery were reduced by 36% and 71%, respectively, in the VCA group. One study reported 2 clinically silent pulmonary cement embolism and 1 patient requiring surgical decompression for cement leak into the spinal canal.
Conclusion
This meta-analysis supported the use of VCA in corrective surgery for spinal deformities patients, especially in patients with advanced age and osteoporosis.
9.Does Vertebral Cement Augmentation Reduce Postoperative Proximal Junction Complications in Spinal Deformity Corrective Surgery: A Systematic Review and Meta-analysis
Dong LI ; Xin SUN ; Jie LI ; Yanjie XU ; Yong QIU ; Zezhang ZHU ; Zhen LIU
Neurospine 2025;22(1):51-66
Objective:
To assess the effectiveness of vertebral cement augmentation (VCA) at upper instrumented vertebra (UIV) and UIV+1 in preventing proximal junction complications in correction surgery for adult spinal deformity patients.
Methods:
A literature search was conducted on Web of Science, PubMed, and Cochrane Library databases for comparative studies published before December 30th, 2024. Two reviewers independently screened eligible articles based on the inclusion and exclusion criteria, assessed study quality with Newcastle-Ottawa scale, and extracted data like study characteristics, surgical details, primary and secondary outcomes. Data analysis was performed using Review Manager 5.4 and Stata software.
Results:
Of all 513 papers screened, a meta-analysis was conducted on 7 articles, which included 333 cases in the VCA group and 827 cases in the control group. Patients in the VCA group had significantly older age and lower T score than patients in the control group. Although there was no statistically significant difference in the incidence of proximal junctional failure between the 2 groups, the results of the meta-analysis showed that the incidence of proximal junctional failure and the need for revision surgery were reduced by 36% and 71%, respectively, in the VCA group. One study reported 2 clinically silent pulmonary cement embolism and 1 patient requiring surgical decompression for cement leak into the spinal canal.
Conclusion
This meta-analysis supported the use of VCA in corrective surgery for spinal deformities patients, especially in patients with advanced age and osteoporosis.
10.Joint effect of sitting posture habits and screen viewing distance on screening myopia among primary school students
ZHAO Ruilan, PENG Tao, ZHEN Guoxin, ZHAO Fangfang, LI Li, SONG Qingqing, ZHU Fan, MA Yinghua
Chinese Journal of School Health 2025;46(6):903-907
Objective:
To explore the association of screening myopia and sitting posture habits as well as screen viewing distance among primary school students, providing a scientific basis for myopia prevention and intervention among primary school students.
Methods:
From April to June 2024, a convenient sampling method was used to enroll 1 394 fourth grade students from four primary schools in a district of Beijing for vision examinations and questionnaire surveys. Logistic regression models were employed to analyze the relationship of screening myopia detection and sitting posture habits as well as viewing distance.
Results:
The screening myopia prevalence among primary school students was 63.8%. About 13.1% of students self reported poor sitting posture, and 47.1% selfreported a viewing distance of ≤20 cm. After adjusting for covariates including age, gender, school, sleep quality, parental myopia status, physical fitness level, daily high intensity physical activity, weekend outdoor activity time and types of after school services, Logistic regression analysis showed that students with poor sitting posture were more likely to have screening myopia than those with normal sitting posture ( OR =1.73,95% CI =1.03-2.92); students with a viewing distance of ≤20 cm were more likely to have screening myopia than those with a viewing distance of >20 cm( OR =1.32, 95% CI =1.02-1.71)( P <0.05). The association between sitting posture and screening myopia was more significant among boys( OR =2.00, 95% CI =1.03-3.88, P < 0.05 ). A multiplicative interaction was observed between sitting posture and viewing distance. Compared to primary school students with normal posture and a viewing distance of >20 cm, those with poor posture and a viewing distance of >20 cm were more likely to have screening myopia ( OR =1.82, 95% CI =1.12-2.96, P <0.05).
Conclusions
Both sitting posture habits and screen viewing distance are related to screening myopia in primary school students. Poor sitting posture poses a higher risk than screen distance, and the two factors exhibit an interactive effect on myopia risk.


Result Analysis
Print
Save
E-mail