1.Optimization of linear calibration using two reference substances under complicated chromatographic condition-taking Cassiae Semen as an example
Lingling JIANG ; Ruiying LIANG ; Zhechun LI ; Yi HE ; Xiao LUO ; Shuhong WANG ; Yang YU ; Chang SU
Drug Standards of China 2025;26(3):270-277
Objective:To establish a linear calibration method using two reference substances for seven characteristic peaks of Cassiae Semen under complicated chromatographic condition,and to optimize the method.Methods:Using 15 different types of screened chromatographic columns and 2 components as reference compounds pair,the linear calibration method with 2 reference substances was established to predict the retention time of the other 5 components,and the method was verified by unknown chromatographic columns and unknown samples.Combined with column confirmation number and average coincidence rate of target peaks,the location results were compared comprehen-sively,and the method was optimized according to the defect under the influence of complicated chromatographic condition.Results:The average conformity rate of the target peak of the method before optimization was 73.3%,and the average conformity rate of the target peak of the optimized method was 98.7%.The optimized method has a high-er average peak coincidence rate and a wider range of applicability for the chromatographic column.Conclusion:The optimized linear calibration method using two reference substances can assist the localization analysis of chromato-graphic peaks in the characteristic chromatogram under complicated chromatographic condition.
2.Optimization of linear calibration using two reference substances under complicated chromatographic condition-taking Cassiae Semen as an example
Lingling JIANG ; Ruiying LIANG ; Zhechun LI ; Yi HE ; Xiao LUO ; Shuhong WANG ; Yang YU ; Chang SU
Drug Standards of China 2025;26(3):270-277
Objective:To establish a linear calibration method using two reference substances for seven characteristic peaks of Cassiae Semen under complicated chromatographic condition,and to optimize the method.Methods:Using 15 different types of screened chromatographic columns and 2 components as reference compounds pair,the linear calibration method with 2 reference substances was established to predict the retention time of the other 5 components,and the method was verified by unknown chromatographic columns and unknown samples.Combined with column confirmation number and average coincidence rate of target peaks,the location results were compared comprehen-sively,and the method was optimized according to the defect under the influence of complicated chromatographic condition.Results:The average conformity rate of the target peak of the method before optimization was 73.3%,and the average conformity rate of the target peak of the optimized method was 98.7%.The optimized method has a high-er average peak coincidence rate and a wider range of applicability for the chromatographic column.Conclusion:The optimized linear calibration method using two reference substances can assist the localization analysis of chromato-graphic peaks in the characteristic chromatogram under complicated chromatographic condition.

Result Analysis
Print
Save
E-mail