1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Preparation of γ-Polyglutamic Acid Complex Medical Coating and Analysis of Its Antibacterial Properties
Ke LUAN ; Dong-Hua XU ; Ming-Zhe WANG ; Xu ZHANG ; Qiu-Yan YAN ; De-An SHI ; Rui WANG ; Heng-Chong SHI ; Hong XU
Chinese Journal of Analytical Chemistry 2025;53(7):1196-1203
Medical device related infections caused by bacteria are common complications in clinical practice,and preventing bacterial colonization on the surface of medical materials is one of the important challenges in the medical field.Therefore,there is an urgent need to construct medical coatings that combine antibacterial properties and biocompatibility.In this study,a γ-polyglutamic acid(γ-PGA)complex with long-chain alkyl quaternary ammonium salts formed by electrostatic and hydrophobic interactions was prepared,which was insoluble in water but soluble in organic solvents(e.g.,ethanol),and was capable of constructing antimicrobial coatings on the surfaces of medical materials in a simple and efficient manner.The bactericidal effect of the coating was verified using viable bacteria counting experiments,and the results showed that the bactericidal rate of the coated thermoplastic polyurethane(TPU)membrane against Staphylococcus aureus was greater than 99.9%compared with that of the uncoated TPU membrane.In addition,a cytotoxicity assay was performed using the L929 fibroblast and cell proliferation detection kit(CCK-8),which showed that the survival rate of L929 fibroblasts on coated TPU was greater than 90%.Meanwhile,the hemolysis rate of coated erythrocytes was tested using fresh rabbit red blood cells(RBCs),and the hemolysis rate on the coated TPU surface was 1.5%.The above results indicated that the coating had good biocompatibility.The preparation method of medical antibacterial coating reported in this study provided a new idea for preventing bacterial infections related to implantable/interventional medical devices.
3.The role of BRD4 in HPV16 virus replication in cervical tissue and cells
Le Wang ; Weixin Li ; Yangliu Dong ; Xian Zhao ; Xinli Zhu ; Xuechen Zhang ; Xiangyi Zhe ; Zemin Pan
Acta Universitatis Medicinalis Anhui 2025;60(6):1080-1085
Abstract:
To explore the relationship between the replication-associated bromodomain protein 4 ( BRD4)and human papillomavirus (HPV) 16(HPV16) viral load in cervical squamous cell carcinoma and CIN Ⅰ tissues , confirm the effects of BRD4 degradation agent MZ1 on viral load .
Methods :
Thirty HPV16-positive cervi- cal cancer specimens and 30 non-cervical cancer specimens were collected , and the viral load of the samples was detected by real-time fluorescence quantitative PCR , and the expression of BRD4 was analyzed by immunohisto- chemistry and Western blot.
Results :
The viral load was higher in the samples of cervical cancer group than in the samples of non-cancer group , the difference is statistically significant ( P < 0. 01) . Immunohistochemistry results showed that the expression of BRD4 were significantly higher in cervical cancer specimens than in noncancerous specimens , the difference is statistically significant (P < 0. 05) . BRD4 expression was significantly and positively correlated with high viral loads , the difference is statistically significant (P < 0. 001) . the BRD4 degradation agent MZ1 significantly reduced the viral load , the difference is statistically significant (P < 0. 01) .
Conclusion
BRD4 may be involved in the replication of HPV16 virus , and BRD4 degradation agent MZ1 can inhibit the replication of HPV16 virus .
4.Follow-up study of left heart valve regurgitation after implantation of left ventricular assist device
Junjiang LIU ; Wenrui MA ; Dingqian LIU ; Yun ZHAO ; Lili DONG ; Zhe LUO ; Kefang GUO ; Chunsheng WANG ; Xiaoning SUN
Chinese Journal of Clinical Medicine 2025;32(1):72-77
Objective To explore the valve regurgitation status of left heart after the implantation of left ventricular assist device (LVAD) and its effect on prognosis of patients with LVAD implantation. Methods A total of 35 patients with cardiomyopathy who underwent magnetic levitation LVAD implantation at Zhongshan Hospital, Fudan University from February 2021 to July 2024 were retrospectively selected. Clinical data during hospitalization were collected, including preoperative basic data and postoperative valve regurgitation status. Telephone follow-ups were conducted to monitor patients’ survival status and transthoracic echocardiography was used to assess left valve function. Kaplan-Meier survival curves and log-rank test were employed to compare the survival rate of patients with different levels of valve regurgitation. Results The 35 patients had a mean age of (53.9±11.1) years, with 85.7% male, and 3 patients (8.6%) died during hospitalization. Preoperatively, 17 patients (48.6%) had moderate or greater mitral regurgitation, while all 35 patients had less than moderate aortic regurgitation. One month postoperatively, thirty patients were followed up, among which 24 patients (80%) had less than moderate mitral regurgitation, including 11 cases with alleviated regurgitation compared to pre-surgery; 6 patients (20%) had moderate or greater mitral regurgitation, including 4 cases with stable regurgitation and 2 cases with progression of regurgitation compared to pre-surgery; 2 patients (6.7%) had progression of aortic regurgitation to moderate or greater. The follow-up time was 1.2 (1.0, 2.1) years, with 1-year survival rate of 91.4% and 3-year survival rate of 71.1%. Survival analysis showed that the 3-year survival rate of patients with moderate or greater mitral regurgitation one month postoperatively was significantly lower than that of patients with less than moderate regurgitation (66.7% vs 83.3%, P=0.046). Conclusions After the implantation of magnetic levitation LVAD, most patients showed improvement in mitral regurgitation, while aortic regurgitation remained unchanged. The degree of mitral regurgitation one month postoperatively is associated with prognosis.
5.Expert consensus on digital restoration of complete dentures.
Yue FENG ; Zhihong FENG ; Jing LI ; Jihua CHEN ; Haiyang YU ; Xinquan JIANG ; Yongsheng ZHOU ; Yumei ZHANG ; Cui HUANG ; Baiping FU ; Yan WANG ; Hui CHENG ; Jianfeng MA ; Qingsong JIANG ; Hongbing LIAO ; Chufan MA ; Weicai LIU ; Guofeng WU ; Sheng YANG ; Zhe WU ; Shizhu BAI ; Ming FANG ; Yan DONG ; Jiang WU ; Lin NIU ; Ling ZHANG ; Fu WANG ; Lina NIU
International Journal of Oral Science 2025;17(1):58-58
Digital technologies have become an integral part of complete denture restoration. With advancement in computer-aided design and computer-aided manufacturing (CAD/CAM), tools such as intraoral scanning, facial scanning, 3D printing, and numerical control machining are reshaping the workflow of complete denture restoration. Unlike conventional methods that rely heavily on clinical experience and manual techniques, digital technologies offer greater precision, predictability, and efficacy. They also streamline the process by reducing the number of patient visits and improving overall comfort. Despite these improvements, the clinical application of digital complete denture restoration still faces challenges that require further standardization. The major issues include appropriate case selection, establishing consistent digital workflows, and evaluating long-term outcomes. To address these challenges and provide clinical guidance for practitioners, this expert consensus outlines the principles, advantages, and limitations of digital complete denture technology. The aim of this review was to offer practical recommendations on indications, clinical procedures and precautions, evaluation metrics, and outcome assessment to support digital restoration of complete denture in clinical practice.
Humans
;
Denture, Complete
;
Computer-Aided Design
;
Denture Design/methods*
;
Consensus
;
Printing, Three-Dimensional
6.Visual analysis of dynamics and hotspots of biomechanics research on diabetic foot based on WoSCC.
Zhe WANG ; Wei-Dong LIU ; Jun LU ; Hong-Mou ZHAO ; Xue-Fei CAO ; Yun-Long ZHANG ; Xin CHANG ; Liang LIU
China Journal of Orthopaedics and Traumatology 2025;38(9):902-909
OBJECTIVE:
To explore the current research status and hotspots in the field of biomechanics of diabetic foot by bibliometric analysis methods.
METHODS:
Literatures related to biomechanics of diabetic foot published in the Web of Scienc Core Collection (WoSCC) from 1981 to 2024 were searched. CiteSpace software and R language bibliometrics plugin were used to conduct a visual analysis of annual publication volume of the literature, including publication volume of each country and region, the publication situation of authors and institutions, the citation situation of individual literature, and the co-occurrence network of keywords.
RESULTS:
Totally 996 literatures were included, and the number of published papers increased steadily. The United States (261 papers) and China (89 papers) were the top two countries in terms of the number of published papers. The mediating centrality of the United States was 0.94, and that of China was 0.01. Scholars such as Cavanagh and institutions like the Cleveland Clinic were at the core of research in this field. High-frequency keywords include plantar pressure (plantar pressure), diabetic foot (diabetic foot), ulceration (ulcer), etc. The research focuses on plantar pressure, ulcer formation and prevention, etc.
CONCLUSION
Biomechanical research on diabetic foot mainly focuses on the pressure distribution on the sole of the foot, callus formation, mechanical analysis of soft tissues on the sole of the foot, and the study of plantar decompression caused by Achilles tendon elongation. The research trend has gradually shifted from focusing on joint range of motion to gait and the design of braces and assistive devices, and has begun to pay attention to muscle strength, gait imbalance and proprioception abnormalities.
Humans
;
Diabetic Foot/physiopathology*
;
Biomechanical Phenomena
;
Bibliometrics
7.Predictive value of bpMRI for pelvic lymph node metastasis in prostate cancer patients with PSA≤20 μg/L.
Lai DONG ; Rong-Jie SHI ; Jin-Wei SHANG ; Zhi-Yi SHEN ; Kai-Yu ZHANG ; Cheng-Long ZHANG ; Bin YANG ; Tian-Bao HUANG ; Ya-Min WANG ; Rui-Zhe ZHAO ; Wei XIA ; Shang-Qian WANG ; Gong CHENG ; Li-Xin HUA
National Journal of Andrology 2025;31(5):426-431
Objective: The aim of this study is to explore the predictive value of biparametric magnetic resonance imaging(bpMRI)for pelvic lymph node metastasis in prostate cancer patients with PSA≤20 μg/L and establish a nomogram. Methods: The imaging data and clinical data of 363 patients undergoing radical prostatectomy and pelvic lymph node dissection in the First Affiliated Hospital of Nanjing Medical University from July 2018 to December 2023 were retrospectively analyzed. Univariate analysis and multivariate logistic regression were used to screen independent risk factors for pelvic lymph node metastasis in prostate cancer, and a nomogram of the clinical prediction model was established. Calibration curves were drawn to evaluate the accuracy of the model. Results: Multivariate logistic regression analysis showed extrocapusular extension (OR=8.08,95%CI=2.62-24.97, P<0.01), enlargement of pelvic lymph nodes (OR=4.45,95%CI=1.16-17.11,P=0.030), and biopsy ISUP grade(OR=1.97,95%CI=1.12-3.46, P=0.018)were independent risk factors for pelvic lymph node metastasis. The C-index of the prediction model was 0.834, which indicated that the model had a good prediction ability. The actual value of the model calibration curve and the prediction probability of the model fitted well, indicating that the model had a good accuracy. Further analysis of DCA curve showed that the model had good clinical application value when the risk threshold ranged from 0.05 to 0.70.Conclusion: For prostate cancer patients with PSA≤20 μg/L, bpMRI has a good predictive value for the pelvic lymph node metastasis of prostate cancer with extrocapusular extension, enlargement of pelvic lymph nodes and ISUP grade≥4.
Humans
;
Male
;
Prostatic Neoplasms/diagnostic imaging*
;
Lymphatic Metastasis
;
Retrospective Studies
;
Nomograms
;
Prostate-Specific Antigen/blood*
;
Lymph Nodes/pathology*
;
Pelvis
;
Predictive Value of Tests
;
Prostatectomy
;
Lymph Node Excision
;
Risk Factors
;
Magnetic Resonance Imaging
;
Logistic Models
;
Middle Aged
;
Aged
8.Efficacy and Safety of Yangxue Qingnao Pills Combined with Amlodipine in Treatment of Hypertensive Patients with Blood Deficiency and Gan-Yang Hyperactivity: A Multicenter, Randomized Controlled Trial.
Fan WANG ; Hai-Qing GAO ; Zhe LYU ; Xiao-Ming WANG ; Hui HAN ; Yong-Xia WANG ; Feng LU ; Bo DONG ; Jun PU ; Feng LIU ; Xiu-Guang ZU ; Hong-Bin LIU ; Li YANG ; Shao-Ying ZHANG ; Yong-Mei YAN ; Xiao-Li WANG ; Jin-Han CHEN ; Min LIU ; Yun-Mei YANG ; Xiao-Ying LI
Chinese journal of integrative medicine 2025;31(3):195-205
OBJECTIVE:
To evaluate the clinical efficacy and safety of Yangxue Qingnao Pills (YXQNP) combined with amlodipine in treating patients with grade 1 hypertension.
METHODS:
This is a multicenter, randomized, double-blind, and placebo-controlled study. Adult patients with grade 1 hypertension of blood deficiency and Gan (Liver)-yang hyperactivity syndrome were randomly divided into the treatment or the control groups at a 1:1 ratio. The treatment group received YXQNP and amlodipine besylate, while the control group received YXQNP's placebo and amlodipine besylate. The treatment duration lasted for 180 days. Outcomes assessed included changes in blood pressure, Chinese medicine (CM) syndrome scores, symptoms and target organ functions before and after treatment in both groups. Additionally, adverse events, such as nausea, vomiting, rash, itching, and diarrhea, were recorded in both groups.
RESULTS:
A total of 662 subjects were enrolled, of whom 608 (91.8%) completed the trial (306 in the treatment and 302 in the control groups). After 180 days of treatment, the standard deviations and coefficients of variation of systolic and diastolic blood pressure levels were lower in the treatment group compared with the control group. The improvement rates of dizziness, headache, insomnia, and waist soreness were significantly higher in the treatment group compared with the control group (P<0.05). After 30 days of treatment, the overall therapeutic effects on CM clinical syndromes were significantly increased in the treatment group as compared with the control group (P<0.05). After 180 days of treatment, brachial-ankle pulse wave velocity, ankle brachial index and albumin-to-creatinine ratio were improved in both groups, with no statistically significant differences (P>0.05). No serious treatment-related adverse events occurred during the study period.
CONCLUSIONS
Combination therapy of YXQNP with amlodipine significantly improved symptoms such as dizziness and headache, reduced blood pressure variability, and showed a trend toward lowering urinary microalbumin in hypertensive patients. These findings suggest that this regimen has good clinical efficacy and safety. (Registration No. ChiCTR1900022470).
Humans
;
Amlodipine/adverse effects*
;
Drugs, Chinese Herbal/adverse effects*
;
Male
;
Female
;
Hypertension/complications*
;
Middle Aged
;
Treatment Outcome
;
Drug Therapy, Combination
;
Adult
;
Blood Pressure/drug effects*
;
Double-Blind Method
;
Aged
;
Antihypertensive Agents/adverse effects*
9.A synthetic peptide, derived from neurotoxin GsMTx4, acts as a non-opioid analgesic to alleviate mechanical and neuropathic pain through the TRPV4 channel.
ShaoXi KE ; Ping DONG ; Yi MEI ; JiaQi WANG ; Mingxi TANG ; Wanxin SU ; JingJing WANG ; Chen CHEN ; Xiaohui WANG ; JunWei JI ; XinRan ZHUANG ; ShuangShuang YANG ; Yun ZHANG ; Linda M BOLAND ; Meng CUI ; Masahiro SOKABE ; Zhe ZHANG ; QiongYao TANG
Acta Pharmaceutica Sinica B 2025;15(3):1447-1462
Mechanical pain is one of the most common causes of clinical pain, but there remains a lack of effective treatment for debilitating mechanical and chronic forms of neuropathic pain. Recently, neurotoxin GsMTx4, a selective mechanosensitive (MS) channel inhibitor, has been found to be effective, while the underlying mechanism remains elusive. Here, with multiple rodent pain models, we demonstrated that a GsMTx4-based 17-residue peptide, which we call P10581, was able to reduce mechanical hyperalgesia and neuropathic pain. The analgesic effects of P10581 can be as strong as morphine but is not toxic in animal models. The anti-hyperalgesic effect of the peptide was resistant to naloxone (an μ-opioid receptor antagonist) and showed no side effects of morphine, including tolerance, motor impairment, and conditioned place preference. Pharmacological inhibition of TRPV4 by P10581 in a heterogeneous expression system, combined with the use of Trpv4 knockout mice indicates that TRPV4 channels may act as the potential target for the analgesic effect of P10581. Our study identified a potential drug for curing mechanical pain and exposed its mechanism.
10.Comparative Study of Clinical Trial Ethics Between China and Foreign Countries Based on CiteSpace
Jianfang DONG ; Kangqi LI ; Yang YANG ; Zhe WANG ; Weiwei ZHU ; Congxiao LU ; Wenwen ZHENG
Herald of Medicine 2025;44(1):157-164
Objective To provide relevant suggestions for ethical considerations in clinical research by searching literature related to ethics in clinical research using the visualization analysis software CiteSpace,and to analyze and compare the current research status of clinical research ethics at home and abroad.Methods The papers on the application of medical ethics in clinical trials from the core collection of CNKI and Web of Science databases were collected and the bibliometric software CiteSpace was used to draw a knowledge map of domestic and foreign literature.The research hotspots and development trends of medical ethics in clinical trials were analyzed.Results In terms of the process of informed consent,risk minimization,fair selection,and protection on the rights and interests of vulnerable groups,the focus of medical ethics research in China were basically consistent with foreign literature.The difference was that foreign research focused more on ethical education,the quality of life of research participants,and ethical counseling.Otherwise,domestic research focused more on the quality management of clinical trials and the specificity of traditional Chinese medicine research,with research on vulnerable groups mostly focused on children.Conclusion Chinese researchers should strengthen multi-dimensional research on medical ethics in China,and gradually expand their view from ethical review points and management research to applied research solved clinical problems and the specificity of research participants,and increasing the number and dimensions of research.


Result Analysis
Print
Save
E-mail