1.Updates and amendments of the Chinese Pharmacopoeia 2025 Edition (Volume Ⅰ)
LI Hao ; SHEN Mingrui ; ZHANG Pang ; ZHAI Weimin ; NI Long ; HAO Bo ; ZHAO Yuxin ; HE Yi ; MA Shuangcheng ; SHU Rong
Drug Standards of China 2025;26(1):017-022
The Chinese Pharmacopoeia is the legal technical standard which should be followed during the research, production, use, and administration of drugs. At present, the new edition of the Chinese Pharmacopoeia is planned to be promulgated and implemented. This article summarizes and analyzes the main characteristics and the content of updates and amendments of the Chinese Pharmacopoeia 2025 Edition(Volume Ⅰ), to provide a reference for the correct understanding and accurate implementation the new edition of the pharmacopoeia.
2.Visual feature extraction combining dissolution testing for the study of drug release behavior of gliclazide modified release tablets
Si-yu CHEN ; Ze-ya LI ; Ping LI ; Xin-qing ZHAO ; Tao GONG ; Li DENG ; Zhi-rong ZHANG
Acta Pharmaceutica Sinica 2025;60(1):225-231
Oral solid dosage forms require processes such as disintegration and dissolution to release the drug before it can be absorbed and utilized by the body. In this manuscript, imaging technology was used to continuously visualize and characterize the
3.Prevalence trends of elevated blood pressure and its association with nutritional status among primary and secondary school students in Inner Mongolia
Chinese Journal of School Health 2025;46(9):1342-1345
Objective:
To analyze the prevalence trends of different types of elevated blood pressure and their association with nutritional status among primary and secondary school students in Inner Mongolia from 2019 to 2024, providing references for targeted prevention strategies.
Methods:
From September 2019 to 2024, a stratified random cluster sampling method was used to select 12 primary and secondary schools from each league city in Inner Mongolia Autonomous Region. A total of 177 108, 137 758, 190 182, 180 084 , 188 056, 180 351 primary and secondary school students (excluding grades one to three of primary school) were included for physical examination. The correlation between their nutritional status and high blood pressure was analyzed based on the basic situation of 129 821 primary and secondary school students who completed a questionnaire survey at the same time in 2024. Statistical analysis was conducted using a Chi-square test and multiple Logistic regression model.
Results:
From 2019 to 2024, the detection rates of elevated blood pressure were 13.60%, 13.68%, 17.60%, 17.24%, 14.77% and 15.96%, respectively. The rates for isolated systolic hypertension were 4.24%, 5.83%, 7.26%, 7.19%, 6.24% and 6.93%; isolated diastolic hypertension rates were 6.38%, 4.99%, 6.23 %, 6.41%, 5.39% and 5.66%; and combined systolic and diastolic hypertension rates were 2.97%, 2.86%, 4.11%, 3.65%, 3.14 % and 3.36%. Multivariate Logistic regression analysis showed that girls, junior high school, senior high school, overweight, and obesity were positively associated with elevated blood pressure risk ( OR =1.27, 1.25, 1.32, 1.66, 3.07, all P <0.05); conversely, county residence, Mongolian ethnicity, and other ethnicities showed negative associations ( OR =0.90, 0.93, 0.90, all P <0.05).
Conclusions
Overweight and obesity among children and adolescents are closely related to various types of elevated blood pressure. Prevention strategies should prioritize effectively controlling weight issues among children and adolescents, thereby effectively reducing the incidence of elevated blood pressure.
4.Guideline for the workflow of clinical comprehensive evaluation of drugs
Zhengxiang LI ; Rong DUAN ; Luwen SHI ; Jinhui TIAN ; Xiaocong ZUO ; Yu ZHANG ; Lingli ZHANG ; Junhua ZHANG ; Hualin ZHENG ; Rongsheng ZHAO ; Wudong GUO ; Liyan MIAO ; Suodi ZHAI
China Pharmacy 2025;36(19):2353-2365
OBJECTIVE To standardize the main processes and related technical links of the clinical comprehensive evaluation of drugs, and provide guidance and reference for improving the quality of comprehensive evaluation evidence and its transformation and application value. METHODS The construction of Guideline for the Workflow of Clinical Comprehensive Evaluation of Drugs was based on the standard guideline formulation method of the World Health Organization (WHO), strictly followed the latest definition of guidelines by the Institute of Medicine of the National Academy of Sciences of the United States, and conformed to the six major areas of the Guideline Research and Evaluation Tool Ⅱ. Delphi method was adopted to construct the research questions; research evidence was established by applying the research methods of evidence-based medicine. The evidence quality classification system of the Chinese Evidence-Based Medicine Center was adopted for evidence classification and evaluation. The recommendation strength was determined by the recommendation strength classification standard formulated by the Oxford University Evidence-Based Medicine Center, and the recommendation opinions were formed through the expert consensus method. RESULTS & CONCLUSIONS The Guideline for the Workflow of Clinical Comprehensive Evaluation of Drugs covers 4 major categories of research questions, including topic selection, evaluation implementation, evidence evaluation, and application and transformation of results. The formulation of this guideline has standardized the technical links of the entire process of clinical comprehensive evaluation of drugs, which can effectively guide the high-quality and high-efficient development of this work, enhance the standardized output and transformation application value of evaluation evidence, and provide high-quality evidence support for the scientific decision-making of health and the rationalization of clinical medication.
5.Study on the effect and mechanism of the alcoholic extract from Scabiosa comosa against hepatic fibrosis
Rong JIN ; Xiaolu ZHAO ; Yuxin YAN ; Xiaoyang GAO ; Chunyan ZHANG ; Mingqi LI ; Yuehong MA
China Pharmacy 2024;35(3):277-282
OBJECTIVE To explore the effect and mechanism of the alcoholic extract from Scabiosa comosa against hepatic fibrosis (HF). METHODS Intragastrical administration of carbon tetrachloride was given to induce HF model. By observing the pathological changes in liver tissue, mRNA and protein expressions of HF indexes [α-smooth muscle actin (α-SMA), collagen type Ⅰ] and phosphoinositide 3-kinase (PI3K)/protein kinase B (Akt) pathway-related factors were detected, and the improvement effects and possible mechanism of low-dose, medium-dose and high-dose (50, 100, 200 mg/kg) of alcoholic extract from S. comosa on HF model rats were investigated. Drug-containing serum was prepared by intragastrical administration of alcoholic extract from S. comosa at a concentration of 1 800 mg/(kg·d) (calculated by the amount of raw material). The effects of drug- containing serum of alcoholic extract from S. comosa on the expression of miRNA-21 were observed through the intervention of HSC-T6 cells with low, medium and high concentrations of drug-containing serum of alcoholic extract from S. comosa (diluted to 10%, 15%, 20%). miRNA-21 mimics or inhibitors were used to transfect HSC-T6 cells, and the mRNA and protein expressions of factors related to the PI3K/Akt signaling pathway were detected. RESULTS The results of in vivo experiments showed that low, medium and high doses of alcoholic extract from S. comosa significantly ameliorated the histopathological changes in liver tissue of HF rats, and the percentage of collagen was significantly reduced (P<0.01); mRNA and protein expressions of the indicators related to HF as well as PI3K and Akt were significantly reduced (P<0.01), and mRNA and protein expressions of phosphatase and tensin homolog deleted on chromosome ten (PTEN) were increased in liver tissue of rats (P<0.01). The results of in vitro experiments showed that drug-containing serum of alcoholic extract from S. comosa significantly inhibited the expression of miRNA-21 at low, medium and high concentrations (P<0.01); whereas after transfection with miRNA-21 mimics, it was found that miRNA-21 mimics significantly increased mRNA and protein expressions of PI3K and Akt (P<0.01), while significantly decreased mRNA and protein expressions of PTEN (P<0.01); after transfection with miRNA-21 inhibitor, the changes of above indexes were opposite to the above results (P<0.01). CONCLUSIONS Alcoholic extracts of S. comosa may inhibit the PI3K/Akt signaling pathway by affecting the expression of miRNA-21, so as to achieve the effect of anti-hepatic fibrosis.
6.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
7.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
8.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
9.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
10.Expert opinions on operation rules of Morita therapy outpatient service
Jiangbo LI ; Zucheng WANG ; Yuhua CUI ; Yingzhi LU ; Weijie QU ; Haiyin ZHANG ; Fuqiang MAO ; Fengqing QIE ; Wanghong SHI ; Qinfeng ZHANG ; Lingyi PAN ; Ling ZHANG ; Jianzhong LI ; Guangcheng CUI ; Tongxian CHEN ; Xiuqing MA ; Wei RONG ; Jianjun ZHANG ; Qingfang ZHONG ; Yanchi ZHANG ; Boquan ZHANG ; Xinrui WANG ; Wenyou MA ; Qingtao REN ; Yongfa JING ; Huanzhong LIU ; Zhenjian YU ; Laitian ZHAO ; Tianming HAN ; Xue HAN
Chinese Mental Health Journal 2024;38(1):68-72
Morita therapy has been bom for more than 100 years.Inpatient Morita therapy is highly oper-able and easy to master.It can improve many refractory neuroses through four-stage treatment.But more neuroses are treated in outpatient clinics,and Morita therapy cannot be used in hospitalized patients.Therefore,the formula-tion of expert opinions on outpatient operations is particularly important.This paper is based on domestic and for-eign references,and after many discussions by domestic Morita therapy experts,and then drew up the first version of the expert opinions on operation of outpatient Morita therapy.Meanwhile the operation rule of Morita therapy in three stages of outpatient treatment was formulated:in the etiological analysis stage,under the theoretical guidance of Morita therapy,analyze the pathogenic factors,to improve treatment compliance and reduce resistance;during the operating stage,guide patients to engage in constructive and meaningful actions,realizing the achievement of letting nature take its course principle;in the cultivating character and enriching life stage,pay attention to positive infor-mation,expanding the scope and content of actions,improving the ability to adapt to complex life,and preventing recurrence caused by insufficient abilities.It will lay a foundation for the promotion of Morita therapy in domestic outpatient clinics,so that more patients with neurosis and other psychological diseases could receive characteristic Morita therapy treatment in outpatient clinics.


Result Analysis
Print
Save
E-mail