1.Seroprevalence characteristics of hepatitis E virus among blood donors infected with hepatitis B virus
Qin YU ; Tingting XU ; Hao YANG ; Lei ZHAO
Chinese Journal of Blood Transfusion 2025;38(1):1-6
[Objective] To investigate the seroprevalence characteristics of hepatitis E virus (HEV) among blood donors with hepatitis B virus (HBV) infection, so as to provide data support for the monitoring, prevention and treatment of HEV. [Methods] From January to December 2022, 219 samples positive for hepatitis B surface antigen (HBsAg), 142 occult hepatitis B virus infection (OBI) samples (HBV group) and 873 samples tested negative (control group) were collected. 361 samples were further tested with viral load assay and serological testing for five serological markers (HBsAg, HBsAb, HBeAg, HBeAb and HBcAb), and the DNA load was measured using real time fluorescence quantitative PCR. Commercially available enzyme-linked immunosorbent assays (ELISA) were used for the detection of anti-HEV IgG, anti-HEV IgM and HEV antigen (Ag). The Chi-square test or Fisher's exact test was used to assess the differences in the reactivity rates of anti-HEV IgG and anti-HEV IgM among different blood donor populations and different variables. Multivariable logistic regression was used to examine potential risk factors associated with anti-HEV IgG seroprevalence. [Results] In the HBV group, HBsAg positive donors exhibited low expression of antigen. The HBV DNA load of OBI infected donors ranged from 1 to 131.43 IU/mL (median 11.24 IU/mL). The prevalence of anti-HEV IgG and IgM antibody in the HBV group were 34.63% and 1.11%, respectively. Among them, the prevalence of anti-HEV IgG and anti-HEV IgM in the HBV group was 34.63% and 0, respectively (P<0.05), while in the OBI donors, they were 41.55% and 2.82%, respectively. In the normal donors, the reactivity rates for anti-HEV IgG and anti-HEV IgM were 18.67% and 1.49%, respectively. Statistical analysis showed that there was a difference in the reactivity rate of anti-HEV IgG between the HBV-infected donors and the normal donors (34.63% vs 18.67%, P<0.05), but no difference in the reactivity rate of anti-HEV IgM (1.11% vs 1.49%, P>0.05). No HEV Ag was detected in either group of blood donors. Multivariate logistic regression analysis indicated that age was an independent risk factor for anti-HEV IgG reactivity in both groups of blood donors. [Conclusion] The reactivity rate of anti-HEV IgG among HBV-infected blood donors was significantly higher than that in the normal donors in Wuhan, with age being an independent risk factor. Therefore, for HBV-infected donors, it is essential to strengthen and prioritize the prevention and treatment of HEV to reduce the spread of HEV.
2.Bioinformatics analysis of potential biomarkers for primary osteoporosis
Jiacheng ZHAO ; Shiqi REN ; Qin ZHU ; Jiajia LIU ; Xiang ZHU ; Yang YANG
Chinese Journal of Tissue Engineering Research 2025;29(8):1741-1750
BACKGROUND:Primary osteoporosis has a high incidence,but the pathogenesis is not fully understood.Currently,there is a lack of effective early screening indicators and treatment programs. OBJECTIVE:To further explore the mechanism of primary osteoporosis through comprehensive bioinformatics analysis. METHODS:The primary osteoporosis data were obtained from the gene expression omnibus(GEO)database,and the differentially expressed genes were screened for Gene Ontology(GO)function and Kyoto Encyclopedia of Genes and Genomes(KEGG)pathway enrichment analysis.In addition,the differentially expressed genes were subjected to protein-protein interaction network to determine the core genes related to primary osteoporosis,and the least absolute shrinkage and selection operator algorithm was used to identify and verify the primary osteoporosis-related biomarkers.Immune cell correlation analysis,gene enrichment analysis and drug target network analysis were performed.Finally,the biomarkers were validated using qPCR assay. RESULTS AND CONCLUSION:A total of 126 differentially expressed genes and 5 biomarkers including prostaglandins,epidermal growth factor receptor,mitogen-activated protein kinase 3,transforming growth factor B1,and retinoblastoma gene 1 were obtained in this study.GO analysis showed that differentially expressed genes were mainly concentrated in the cellular response to oxidative stress and the regulation of autophagy.KEGG analysis showed that autophagy and senescence pathways were mainly involved.Immunoassay of biomarkers showed that prostaglandins,retinoblastoma gene 1,and mitogen-activated protein kinase 3 were closely related to immune cells.Gene enrichment analysis showed that biomarkers were associated with immune-related pathways.Drug target network analysis showed that the five biomarkers were associated with primary osteoporosis drugs.The results of qPCR showed that the expression of prostaglandins,epidermal growth factor receptor,mitogen-activated protein kinase 3,and transforming growth factor B1 in the primary osteoporosis sample was significantly increased compared with the control sample(P<0.001),while the expression of retinoblastoma gene 1 in the primary osteoporosis sample was significantly decreased compared with the control sample(P<0.001).Overall,the study screened and validated five potential biomarkers of primary osteoporosis,providing a reference basis for further in-depth investigation of the pathogenesis,early screening and diagnosis,and targeted treatment of primary osteoporosis.
3.Efficacy of Fufang Lingjiao Jiangya Pills with Different Proportions of Goat Horn Replacing Antelope Horn on Spontaneous Hypertensive Rats
Tengjian WANG ; Wanlu ZHAO ; Yang YU ; Yan LIU ; Kun CAO ; Zheyuan LIN ; Yue WU ; Lilan LUO ; Weizhi LAI ; Zhaohuan LOU ; Qiaoyan ZHANG ; Quanlong ZHANG ; Luping QIN
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(9):68-78
ObjectiveTo investigate the optimal ratio of goat horn replacing antelope horn in Fufang Lingjiao Jiangya pills and the blood pressure-lowering mechanism of this medicine. MethodsThe blood pressure-lowering efficacy of Fufang Lingjiao Jiangya pills with varying proportions of goat horn replacing antelope horn was evaluated on spontaneous hypertensive rats (SHR). In this experiment, 50 SHR rats were randomly grouped as follows: model (n=8), captopril (0.01 g·kg-1) (n=6), low-dose blank Fufang Lingjiao Jiangya pills (0.342 g·kg-1) (n=6), high-dose blank Fufang Lingjiao Jiangya pills (0.684 g·kg-1) (n=6), low-dose antelope horn-containing Fufang Lingjiao Jiangya pills (0.378 g·kg-1) (n=6), high-dose antelope horn-containing Fufang Lingjiao Jiangya pills (0.756 g·kg-1) (n=6), low-dose goat horn-containing Fufang Lingjiao Jiangya pills (0.378 g·kg-1) (n=6), and high-dose goat horn-containing Fufang Lingjiao Jiangya pills (0.756 g·kg-1) (n=6). Additionally, 8 WKY rats were used as the normal group. Drugs were administered by gavage for 4 weeks while an equal volume of distilled water was administered for the normal and model groups. Blood pressure was measured before administration, 3 h post administration, and biweekly thereafter. In the experiment for Fufang Lingjiao Jiangya pills with goat horn replacing antelope horn in different proportions, 48 SHR rats were randomly grouped as follows: model, blank Fufang Lingjiao Jiangya pills (0.684 g·kg-1), antelope horn-containing Fufang Lingjiao Jiangya pills (0.756 g·kg-1), 2× goat horn-containing Fufang Lingjiao Jiangya pills (0.824 g·kg-1), 4× goat horn Fufang Lingjiao Jiangya pills (0.969 g·kg-1), and 6× goat horn Fufang Lingjiao Jiangya pills (1.112 g·kg-1). The normal group included 8 WKY rats, and the normal group and model group received an equal volume of distilled water. The treatment lasted for 2 weeks, and blood pressure was recorded at various time points (pre-administration, 3 h post administration, and on days 4, 7, 10, and 14 of administration). Serum levels of angiotensin-converting enzyme (ACE), angiotensin Ⅱ(Ang Ⅱ), renin, and interleukin-6 (IL-6) were measured by enzyme-linked immunosorbent assay. Histopathological changes in the heart, kidney, and thoracic aorta were observed by hematoxylin-eosin staining. The protein levels of ACE2, angiotensin Ⅱ type 1 receptor (AT1R), and angiotensinogen (AGT) in the kidney tissue were determined by Western blot, while the expression of nuclear factor (NF)-κB p65 and Toll-like receptor 4 (TLR4) in the thoracic aorta tissue was assessed by immunohistochemistry. ResultsCompared with the model group, all treatment groups showed lowered blood pressure (P<0.05, P<0.01), and the 6× goat horn-containing Fufang Lingjiao Jiangya pills group showed consistent blood pressure-lowering effect with the antelope horn-containing Fufang Lingjiao Jiangya pills group. Compared with the normal group, the model group showed elevated serum levels of ACE, Ang Ⅱ, renin, and IL-6, while the elevations were declined in the Fufang Lingjiao Jiangya pills groups (P<0.05, P<0.01). Pathological changes in the heart, kidney, and thoracic aorta were alleviated in all the treatment groups, with the 6× goat horn- and antelope horn-containing Fufang Lingjiao Jiangya pills groups exhibited the best effect. Western blot and immunohistochemistry results showed that all the treatment groups exhibited down-regulated protein levels of AT1R, AGT, NF-κB p65, and TLR4 and up-regulated protein levels of ACE2 (P<0.05, P<0.01) compared with model group, with the 6×goat horn- and antelope horn-containing Fufang Lingjiao Jiangya pills groups showcasing the best effect. ConclusionReplacing antelope horn with 6×goat horn in Fufang Lingjiao Jiangya pills can achieve consistent blood pressure-lowering effect with the original prescription. The prescription may exert the effect by inhibiting the renin-angiotensin-aldosterone system (RAAS) and TLR4/NF-κB signaling pathways.
4.Research on The Construction and Application of Multiple Fluorescence Amplification System for Three Kinds of Stains
Yi-Fan BAI ; He-Miao ZHAO ; Jing CHEN ; Hong-Di LIU ; Rui-Qin YANG ; Chong WANG
Progress in Biochemistry and Biophysics 2025;52(4):982-994
ObjectiveA multiplex amplification system was constructed based on the capillary electrophoresis platform for simultaneous detection of saliva, semen, and vaginal secretions using tissue-specific RNA markers. The aim of this study is to identify the tissue origin of suspicious body fluid stains found at crime scenes and determine whether the body fluid stains at the crime scene are one or several types among saliva, semen, and vaginal secretions. MethodsThirty saliva samples, forty semen samples, and forty vaginal secretion samples (half from 2015 and half from 2024) were collected from healthy adult volunteers. Through primer designing, system formulation, and PCR condition optimization, a multiplex fluorescent amplification system was constructed. The specificity, sensitivity, and detection ability for mixed samples of this system were investigated, and it was tested using real crime scene materials. In the primer design stage, to reduce the requirements for RNA template quality, the amplification products were set within 80-300 bp. In the system formulation stage, dominant and subordinate primers were mainly considered. By reducing the concentration of dominant primers and increasing that of subordinate primers, a capillary electrophoresis spectrum with an appropriate peak height ratio was finally obtained. Additionally, gradient experiments were designed to adjust the concentrations of PCR reagents and PCR amplification conditions, and multiple versions of DNA amplification enzymes were optimized to achieve the best experimental results. ResultsThrough statistical analysis, there was no significant difference in the capillary electrophoresis of the 3 types of body fluid samples from the two years (2015 and 2024), demonstrating that the sample preservation method in this study can preserve samples for a relatively long time. The composite amplification system constructed in this study exhibited high specificity for all 3 types of body fluid, with no cross-reactions between the markers of each type of body fluid. The minimum detection thresholds for the 3 types of body fluid reached 0.002 9, 0.001 5, and 0.42 mg/L, respectively. This system also had a high degree of discrimination for mixed samples, especially for semen-saliva mixtures, where each body fluid marker could still be successfully detected when the concentration ratio of semen to saliva was 100:1. Meanwhile, in the two actual cases presented in this article, the application of this composite amplification system performed outstandingly. ConclusionThe composite amplification detection system constructed in this study can achieve the correct screening of saliva, semen, and vaginal secretions, overcoming the problems such as low specificity and sensitivity of marker tests and unbalanced RFU values of each marker in previous studies. The specificity and sensitivity meet the practical work requirements, and the operation is simple. It provides an analytical and identification method for body fluid stains in actual case and is applicable to the identification of the tissue origin of biological evidence at crime scenes involving sexual assault, indecent assault, and other criminal acts. In the future, more types of body fluid markers will be screened to expand the types of body fluids detected by the system, and body fluid-specific cSNP and cInDel genetic markers will be introduced to infer the sources (individuals and types) of mixed and complex stains more accurately.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Analysis of human parvovirus B19 nucleic acid detection in blood products in China
Yue WANG ; Xiaobei ZHENG ; Qin GONG ; Ying ZHAO ; Yuanxiu LUO ; Dandan YANG ; Linlin ZHANG ; Zheng JIANG ; Gan PENG ; Jin ZHANG ; Bingbing KE
Chinese Journal of Blood Transfusion 2025;38(7):950-957
Objective: To analyze the nucleic acid load of human parvovirus B19 in major commercially available blood products in China, including human albumin, human intravenous immunoglobulin, human rabies immunoglobulin and various coagulation factor products, aiming to provide evidence for improving blood product manufacturing processes and quality control of source plasma. Methods: A total of 98 batches of coagulation factor products were tested for human parvovirus B19 nucleic acid using real-time fluorescent quantitative PCR, including 42 batches of human prothrombin complex, 35 batches of human coagulation factor Ⅷ, and 21 batches of human fibrinogen. Additionally, 6 batches of human albumin, 6 batches of human intravenous immunoglobulin, and 38 batches of human rabies immunoglobulin were tested for human parvovirus B19 nucleic acid. Results: Human parvovirus B19 nucleic acid were undetectable in human albumin, human intravenous immunoglobulin and human rabies immunoglobulin. Among the 98 batches of coagulation factor products tested for human parvovirus B19 nucleic acid, B19 nucleic acid reactivity rate was 69.0% (29/42) for human prothrombin complex batches, but nucleic acid concentration were all significantly lower than 10
IU/mL. The reactivity rate of B19 nucleic acid in 35 batches of human coagulation factor Ⅷ was 48.6% (17/35), with nucleic acid concentration all below 10
IU/mL. The reactivity rate of B19 nucleic acid in 21 batches of human fibrinogen was 61.9% (13/21), with nucleic acid concentration all below 10
IU/mL. Conclusion: No human parvovirus B19 has been detected in human albumin, human intravenous immunoglobulin, or human rabies immunoglobulin. Human parvovirus B19 nucleic acid may exist in commercially available coagulation factor products, highlighting the need for enhanced screening of human parvovirus B19 nucleic acid in these products. It is also recommended that B19 viral nucleic acid testing be conducted on source plasma, particularly for coagulation factor products.

Result Analysis
Print
Save
E-mail