1.Effect of Intestinal Microecology on Diabetic Kidney Disease Based on Yin-Yang Theory
Chao MO ; Guodong HUANG ; Wei SHI ; Jie ZHAO
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(3):178-186
Diabetic kidney disease (DKD) is the main cause of end-stage renal disease. Its high prevalence, mortality rate, and medical cost bring a heavy economic burden to society and families, and DKD has become one of the most important public health problems. Intestinal microecology is the most important and complex micro-ecosystem in the human body, which is involved in important life activities such as material and energy metabolism, immune system regulation, and signal transduction, thereby maintaining the dynamic balance of the human internal environment. The dynamic balance between the intestinal microecology and the body is essentially a Yin-Yang balance. Once this balance is broken, intestinal microbiota imbalance, intestinal mucosal barrier damage, immune dysfunction, and reduction of metabolite short-chain fatty acids (SCFAs) will occur, which play an important role in the progression of DKD. From the perspective of the Yin-Yang theory of traditional Chinese medicine (TCM), the imbalance of intestinal microecology in DKD is equivalent to the excessive or insufficient constraint of Yin and Yang, or Yin deficiency affecting Yang, or Yang deficiency affecting Yin, or waning and waxing of Yin and Yang. For different pathogenesis changes, "Yin disease treated through Yang", "treating Yin for Yang", or "treating Yang for Yin" methods are adopted to regulate intestinal microbiota, inhibit immune inflammation, protect intestinal mucosal barrier, and increase SCFAs through TCM, thereby reconciling Yin and Yang to achieve the condition where "Yin is at peace and Yang is compact". Based on the Yin-Yang theory, this paper intended to interpret the scientific connotation of TCM in the treatment of DKD with intestinal microecology as the target and TCM in the treatment of DKD by regulating intestinal microecology as the breakthrough point to provide a novel insight for the occurrence and development of DKD and the mechanism of TCM.
2.Analysis of pre-exposure prophylaxis awareness, willingness, uptake patterns, barriers and needs among MSM students and its influencing factors
Chinese Journal of School Health 2024;45(1):55-59
Objective:
To explore the pre-exposure prophylaxis (PrEP) awareness, willingness, uptake patterns, barriers and needs among Chinese student men who have sex with men (MSM), so as to provide relevant evidence for targeted interventions with PrEP.
Methods:
A proportional sampling method was used to conduct a cross sectional survey of MSM aged 16 years and older residing in 21 provinces, municipalities, and autonomous regions in mainland China between October 20 and December 20, 2021, to collect information on demographic and sexual behavioral characteristics, and 923 students of them were selected as the subjects of this study. The chi-square test and Fisher s test were used for univariate analysis, followed by multivariate Logistic regression to analyze the influencing factors of PrEP awareness and uptake.
Results:
According to the cascade analysis method, the awareness, willingness, uptake and adherence rates of PrEP among the student MSM were obtained as 88.95%, 67.36%, 13.20% and 45.21 %, respectively. HIV testing more than once in the last 3 months, and all of them were aware of the HIV test results of their sexual partners, and those with high frequency of condom use had a higher rate of awareness ( OR =2.32, 1.79, 1.69, P <0.05). Willingness rates were higher for those from the pilot city, using substances, and HIV testing more than once in the last 3 months ( OR =2.13, 1.65, 1.69, P <0.05). Higher rates of uptake were found among those from high risk and pilot areas, presence of commercial sex, substance use, and high literacy ( OR =5.60, 3.54,2.81, 1.92, 4.54, P <0.05). Adherence rates were higher among those who used one pill per day or both ( OR =12.77, 13.26, P <0.05). The barriers and needs faced by student MSM were primarily personal concerns about medication side effects, preventative effects, and confidence in sexual behavioral styles, and the high cost of medication and related service costs.
Conclusions
The student MSM population in China is characterized by high awareness, low willingness, low uptake, and low adherence to PrEP. Targeted interventions should be considered and tailored by the departments to facilitate PrEP promotion among student MSM.
3.Study on the effect of synaptic nuclear protein γ on migration and invasion of oral squamous cell carcinoma cells
Zuo-Dong REN ; Zhao-Wei ZHUANG ; Juan ZHAO ; Wu-Mei YUAN ; Yan ZENG
The Chinese Journal of Clinical Pharmacology 2024;40(9):1267-1271
Objective Lentivirus-mediated interference with synaptic nuclear protein γ(SNCG)in human oral squamous cell carcinoma was established to study the role of SNCG in the migration and invasion of oral squamous cell carcinoma.Methods Oral cancer CAL27 cells were infected with LV-shNC and LV-shSNCG constructed by lentivirus vector,respective,and then selected with puromycin to obtain cell lines stably interfering with SNCG,which were named NC group and experimental group,respectively.Detect the expression of SNCG through real-time quantitative polymerase chain reaction(qRT-PCR)and Western blot experiments;Transwell and scratch experiments were used to detect changes in migration and invasion ability.Results Compared with the NC group,the experimental group showed an 80%reduction in SNCG mRNA expression(P<0.01).The relative expression level of SNCG protein was also decreased in the experimental group compared to the NC group(P<0.01).In the NC group and the experimental group,the migration area percentages at 36 hours were 0.54±0.06 and 0.40±0.02,respectively;and at 48 hours were 0.83±0.01 and 0.47±0.05,respectively.The experimental group showed decrease in migration area compared to the NC group,and these differences were statistically significant(P<0.05,P<0.001).Compared to the NC group,the migration and invasion cell numbers in the experimental group(98.00±13.49 and 88.00±5.72)were significantly reduced to(48.00±2.16 and 49.00±2.94),and these differences were statistically significant(P<0.01,P<0.001).Conclusion Interference of SNCG expression can significantly reduce the migration and invasion ability of oral squamous cell carcinoma cells.
4.Study on characteristic chromatogram of Yao medicine Kadsura longipedunculata and its anwulignan content and anti-inflammatory activity
Binglan TANG ; Wei GAO ; Chengjian ZHAO ; Chunli OU ; Xiaoli HOU ; Lu CHEN ; Dandan MO
China Pharmacy 2024;35(14):1727-1731
OBJECTIVE To establish characteristic chromatogram of Yao medicine Kadsura longipedunculata and the method for the content determination of its main component anwulignan, and evaluate the anti-inflammatory activity of anwulignan. METHODS HPLC method was performed with acetonitrile-0.5% phosphoric acid solution as the mobile phase for gradient elution. The characteristic chromatogram of K. longipedunculata was established and similarity was evaluated by Similarity Evaluation System for Chromatographic Fingerprint of TCM (2012 edition). The content of anwulignan in K. longipedunculata was determined. Lipopolysaccharide induced RAW264.7 macrophages were selected as inflammatory cell model to investigate the effects of anwulignan on the levels of tumor necrosis factor-α (TNF-α), interleukin-1β (IL-1β) and IL-6. RESULTS The similarities of characteristic chromatogram for 10 batches of K. longipedunculata ranged 0.901-0.994, and 9 common peaks were determined; 3 components were identified, such as changnan schisantherin E, kadsulactone A, anwulignan. The contents of anwulignan were (0.72±0.05)-(1.21±0.03) mg/g(n=3). Anwulignan of 0.125-0.5 μg/mL greatly decreased the levels of TNF-α, IL-1β and IL-6 in the supernatant of inflammatory model cells (P<0.05 or P<0.01). CONCLUSIONS HPLC characteristic chromatogram of K. longipedunculata and the method for the content determination of anwulignan are all established, and anwulignan may be the active ingredient of anti-inflammatory effect in K. longipedunculata.
5.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
6.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
7.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
8.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
9.Quality evaluation for Beidougen Formula Granules
Gui-Yun CAO ; Xue-Song ZHUANG ; Bo NING ; Yong-Qiang LIN ; Dai-Jie WANG ; Wei-Liang CUI ; Hong-Chao LIU ; Xiao-Di DONG ; Meng-Meng HUANG ; Zhao-Qing MENG
Chinese Traditional Patent Medicine 2024;46(3):717-723
AIM To evaluate the quality of Beidougen Formula Granules.METHODS Fifteen batches of standard decoctions and three batches of formula granules were prepared,after which paste rate and contents,transfer rates of magnoflorine,daurisoline,dauricine were determined.HPLC specific chromatograms were established,and cluster analysis was adopted in chemical pattern recognition.RESULTS For three batches of formula granules,the paste rates were 15.1%-16.6%,the contents of magnoflorine,daurisoline,dauricine were 18.93-19.39,9.42-9.60,6.79-6.85 mg/g with the transfer rates of 34.42%-35.25%,43.81%-44.65%,27.27%-27.51%from decoction pieces to formula granules,respectively,and there were seven characteristic peaks in the specific chromatograms with the similarities of more than 0.95,which demonstrated good consistence with those of standard decoctions and accorded with related limit requirements.Fifteen batches of standard decoctions were clustered into two types,and the medicinal materials produced from Jilin,Hebei,Shangdong could be used for the preparation of formula granules.CONCLUSION This reasonable and reliable method can provide references for the quality control and clinical application of Beidougen Formula Granules.
10.Association of copy number variation in X chromosome-linked PNPLA4 with heterotaxy and congenital heart disease
Han GAO ; Xianghui HUANG ; Weicheng CHEN ; Zhiyu FENG ; Zhengshan ZHAO ; Ping LI ; Chaozhong TAN ; Jinxin WANG ; Quannan ZHUANG ; Yuan GAO ; Shaojie MIN ; Qinyu YAO ; Maoxiang QIAN ; Xiaojing MA ; Feizhen WU ; Weili YAN ; Wei SHENG ; Guoying HUANG
Chinese Medical Journal 2024;137(15):1823-1834
Background::Heterotaxy (HTX) is a thoracoabdominal organ anomaly syndrome and commonly accompanied by congenital heart disease (CHD). The aim of this study was to analyze rare copy number variations (CNVs) in a HTX/CHD cohort and to examine the potential mechanisms contributing to HTX/CHD.Methods::Chromosome microarray analysis was used to identify rare CNVs in a cohort of 120 unrelated HTX/CHD patients, and available samples from parents were used to confirm the inheritance pattern. Potential candidate genes in CNVs region were prioritized via the DECIPHER database, and PNPLA4 was identified as the leading candidate gene. To validate, we generated PNPLA4-overexpressing human induced pluripotent stem cell lines as well as pnpla4-overexpressing zebrafish model, followed by a series of transcriptomic, biochemical and cellular analyses. Results::Seventeen rare CNVs were identified in 15 of the 120 HTX/CHD patients (12.5%). Xp22.31 duplication was one of the inherited CNVs identified in this HTX/CHD cohort, and PNPLA4 in the Xp22.31 was a candidate gene associated with HTX/CHD. PNPLA4 is expressed in the lateral plate mesoderm, which is known to be critical for left/right embryonic patterning as well as cardiomyocyte differentiation, and in the neural crest cell lineage. Through a series of in vivo and in vitro analyses at the molecular and cellular levels, we revealed that the biological function of PNPLA4 is importantly involved in the primary cilia formation and function via its regulation of energy metabolism and mitochondria-mediated ATP production. Conclusions::Our findings demonstrated a significant association between CNVs and HTX/CHD. Our data strongly suggested that an increased genetic dose of PNPLA4 due to Xp22.31 duplication is a disease-causing risk factor for HTX/CHD.


Result Analysis
Print
Save
E-mail