1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Guideline for diagnosis and treatment of infection after internal fixation of closed lower limb fractures in adults (version 2025)
Bobin MI ; Faqi CAO ; Weixian HU ; Wu ZHOU ; Chenchen YAN ; Hui LI ; Yun SUN ; Yuan XIONG ; Jinmi ZHAO ; Qikai HUA ; Xinbao WU ; Xieyuan JIANG ; Dianying ZHANG ; Zhongguo FU ; Dankai WU ; Guangyao LIU ; Guodong LIU ; Tengbo YU ; Jinhai TAN ; Xi CHEN ; Fengfei LIN ; Zhangyuan LIN ; Dongfa LIAO ; Aiguo WANG ; Shiwu DONG ; Gaoxing LUO ; Zhao XIE ; Dong SUN ; Dehao FU ; Yunfeng CHEN ; Changqing ZHANG ; Kun LIU ; Deye SONG ; Yongjun RUI ; Fei WU ; Ximing LIU ; Junwen WANG ; Meng ZHAO ; Biao CHE ; Bing HU ; Chengjian HE ; Guanglin WANG ; Xiao CHEN ; Guandong DAI ; Shiyuan FANG ; Wenchao SONG ; Ming CHEN ; Guanghua GUO ; Yongqing XU ; Lei YANG ; Wenqian ZHANG ; Kun ZHANG ; Xin TANG ; Hua CHEN ; Weiguo XU ; Shuquan GUO ; Yong LIU ; Xiaodong GUO ; Zhewei YE ; Liming XIONG ; Tian XIA ; Hongbin WU ; Qisheng ZHOU ; Mengfei LIU ; Yiqiang HU ; Yanjiu HAN ; Hang XUE ; Kangkang ZHA ; Wei CHEN ; Zhiyong HOU ; Bin YU ; Jiacan SU ; Peifu TANG ; Baoguo JIANG ; Guohui LIU
Chinese Journal of Trauma 2025;41(5):421-432
Postoperative infection of internal fixation of closed fractures the lower limbs in adults represents a devastating complication, characterized by diagnostic challenges, prolonged treatment duration and high disability rates. Current management of these infections faces multiple challenges, such as difficulties in early accurate diagnosis, and various controversies about the treatment plan, leading to poor overall diagnosis and treatment results. To address these issues, based on evidence-based medicine and principles with emphasis on scientific rigor, clinical applicability and innovation, the Trauma Branch of the Chinese Medical Association, Orthopedic Branch of the Chinese Medical Doctor Association, Orthopedics Branch of the Chinese Medical Association, and Trauma Orthopedics and Polytrauma Group of the Resuscitation and Emergency Committee of the Chinese Medical Doctor Association have collaboratively organized a panel of relevant experts to develop the Guideline for diagnosis and treatment of infection after internal fixation of closed lower limb fractures in adults ( version 2025). The guideline proposed 10 recommendations, aiming to provide a foundation for standardized diagnosis and treatment of postoperative infection in adults with closed lower limb fractures.
7.Application of Digital Nutrition Technologies in Adult Weight Management
Zihan XIONG ; Ning FAN ; Yue ZHAO ; Yuanyuan YAN ; Hui WANG
Journal of Sichuan University (Medical Sciences) 2025;56(4):900-906
Obesity and overweight remain major global public health challenges.In this paper,we examine current applications of digital nutrition technologies in weight management using the scoping review framework of Arksey and O'Malley.Visual recognition technologies have evolved from early-stage food image recognition into more advanced systems,although the vast diversity of food types continues to pose challenges for accuracy and generalizability.The combination of wearable devices and non-wearable sensors has increased the diversity of collected data and improved user comfort.Data integration and analysis tools,such as digital virtual twins,support personalized interventions by integrating multidimensional data.In addition,emerging applications have demonstrated encouraging clinical outcomes.However,existing studies have limitations,such as small sample sizes,high levels of information bias,and low evidence quality.Barriers,such as limited accessibility and high initial costs,further constrain the scalability of digital nutrition tools.Future studies should focus on expanding sample sizes,improving population diversity,and developing effective assessment methods and adjustments for specific target populations.Privacy and data security concerns must also be addressed to ensure safe implementation.Overall,digital nutrition technologies offer a promising approach to weight management,but continuous efforts in research and cost reduction are needed to fully realize their potential in weight management and to promote health for all.
8.Predictive value of dose-surface histogram for acute radiation proctitis in prostate cancer patients following radiotherapy
Xin ZHAO ; Mei-Liu YANG ; Xiao-Hui HAO ; Tian-Xiong WEI ; Qi ZHANG ; Hao-Yu CHANG ; Xiu-Xia WU
Medical Journal of Chinese People's Liberation Army 2025;50(1):44-49
Objective To evaluate the predictive value of dose-surface histogram(DSH)for radiation proctitis(RP)in prostate cancer(PCa)patients undergoing radiotherapy.Methods This prospective randomized controlled clinical trial included 380 PCa patients who underwent image-guided radiotherapy in the First Affiliated Hospital of Hebei Northern University from January 2018 to January 2023.Patients were randomly divided into observation group(n=200)and control group(n=180).The rectal dose distribution of patients in the two groups was evaluated by using DSH and dose-volume histogram(DVH),respectively.The receiver operating characteristic(ROC)curve was utilized to evaluate the predictive value of DSH for acute RP,with DVH serving as a reference.Results The difference was not statistically significant in clinical information such as age,KPS score,and body mass index(BMI)between the observation and control groups(P>0.05),as well as in acute RP incidence(P>0.05).There were significant differences in S40 and V40,S50 and V50,S60 and V60,S70 and V70,and S78 and V78 between the two groups(P<0.05).S40,S50,V40,and V50 showed low efficacy(P<0.001)in predicting acute RP at each level,with AUC≤0.700.S60 and V60 showed moderate efficacy(P<0.001)in predicting acute RP at each level,with AUC 0.700-0.900.S70,S78,V70 and V78 showed high efficacy(P<0.001)in predicting acute RP at each level,with AUC>0.900.Conclusions The predictive value of DSH for rectal toxicity in patients with PCa is basically consistent with that of DVH.It is expected to become a novel and valuable tool for evaluating radiotherapy plans in the future.
9.Deep learning-based fusion of color and spectral features from hyperspectral imaging for the origin identification of Salvia miltiorrhiza
Bai RUIBIN ; Xiong FENG ; Wang HUI ; Luan MEIQI ; Zhou JUNHUI ; Wan XIUFU ; Zhao ZIHAN ; Zhang XIAOBO ; Zhang CHU ; Yang JIAN
Science of Traditional Chinese Medicine 2025;3(3):250-258
Background:Salvia miltiorrhiza Bunge,commonly known as"Danshen"in China due to the distinctive red color of its roots,is one of the most widely used traditional Chinese medicines.It is cultivated in various regions across China,and environmental differences among these regions can affect the secondary metabolites of plants,thereby influencing the quality of S.miltiorrhiza.In recent years,increasing demand for S.miltiorrhiza has exacerbated the problem of origin fraud.Therefore,ensuring the authenticity of its geo-graphical origin is crucial for the sustainable development of the industry.Objective:The red coloration of S.miltiorrhiza is closely associated with the content of its primary active compounds,particularly tanshinones.Therefore,both its internal chemical composition and external color characteristics serve as key indicators for quality assessment.This study utilized hyperspectral imaging technology to evaluate its potential in classifying the geographical origin of S.miltiorrhiza.Methods:Spectral data reflecting the internal chemical properties of S.miltiorrhiza were integrated with color information represent-ing its external features through 3 levels of data fusion.These fused datasets were then combined with deep learning algorithms to achieve accurate origin classification.Results:The results demonstrated that the Transformer model combined with soft-voting decision-level fusion achieved the highest classification accuracy of 98.72%by integrating image color and short-wave infrared spectral data.Conclusion:This study demonstrates that integrating hyperspectral imaging spectral data with color information provides a reliable and innovative approach for verifying the authenticity and traceability of S.miltiorrhiza.
10.Deep learning-based fusion of color and spectral features from hyperspectral imaging for the origin identification of Salvia miltiorrhiza
Ruibin BAI ; Feng XIONG ; Hui WANG ; Meiqi LUAN ; Junhui ZHOU ; Xiufu WAN ; Zihan ZHAO ; Xiaobo ZHANG ; Chu ZHANG ; Jian YANG
Science of Traditional Chinese Medicine 2025;3(3):250-258
Background: Salvia miltiorrhiza Bunge, commonly known as “Danshen” in China due to the distinctive red color of its roots, is one of the most widely used traditional Chinese medicines. It is cultivated in various regions across China, and environmental differences among these regions can affect the secondary metabolites of plants, thereby influencing the quality of S. miltiorrhiza. In recent years, increasing demand for S. miltiorrhiza has exacerbated the problem of origin fraud. Therefore, ensuring the authenticity of its geographical origin is crucial for the sustainable development of the industry. Objective: The red coloration of S. miltiorrhiza is closely associated with the content of its primary active compounds, particularly tanshinones. Therefore, both its internal chemical composition and external color characteristics serve as key indicators for quality assessment. This study utilized hyperspectral imaging technology to evaluate its potential in classifying the geographical origin of S. miltiorrhiza. Methods: Spectral data reflecting the internal chemical properties of S. miltiorrhiza were integrated with color information representing its external features through 3 levels of data fusion. These fused datasets were then combined with deep learning algorithms to achieve accurate origin classification. Results: The results demonstrated that the Transformer model combined with soft-voting decision-level fusion achieved the highest classification accuracy of 98.72% by integrating image color and short-wave infrared spectral data. Conclusion: This study demonstrates that integrating hyperspectral imaging spectral data with color information provides a reliable and innovative approach for verifying the authenticity and traceability of S. miltiorrhiza.

Result Analysis
Print
Save
E-mail