1.Three-dimensional Electrical Impedance Tomography for Monitoring Gastric Hemorrhage
Zi-Han ZHAO ; Bo SUN ; Jing-Shi HUANG ; Zhi-Wei LI ; Yang WU ; Nan LI ; Jia-Feng YAO ; Tong ZHAO
Progress in Biochemistry and Biophysics 2026;53(4):1062-1075
ObjectiveGastric hemorrhage is one of the most common and life-threatening emergencies of the upper digestive tract. Early identification and continuous monitoring are essential for reducing rebleeding rates and mortality, particularly within the critical early hours after onset. Although endoscopy and radiological imaging can accurately localize bleeding sites, these approaches are invasive, resource-intensive, and unsuitable for continuous bedside monitoring. Electrical impedance tomography (EIT), as a noninvasive and radiation-free functional imaging technique, offers real-time visualization of conductivity distribution and has the potential for detecting intragastric bleeding based on the electrical contrast between blood and surrounding gastric tissues. In this study, a three-dimensional gastric EIT (3D-gEIT) framework is proposed to achieve noninvasive, real-time, and dynamic monitoring of gastric hemorrhage, with emphasis on spatial localization and quantitative volume assessment. MethodsA three-dimensional upper-abdominal simulation model incorporating the stomach, gastric wall, gastric contents, and surrounding tissues was established. Three electrode configurations, namely the dual layer ring, the four layer staggered ring, and the opposed dual plane array, were designed and systematically compared to evaluate their influence on depth sensitivity and spatial resolution. Based on the Tikhonov-Noser hybrid regularization scheme, a region-clustering constraint was introduced to develop the TK-Noser-RCC algorithm. This approach aggregates spatially adjacent elements with similar conductivity variations, thereby enhancing structural continuity and suppressing isolated noise artifacts. To validate the proposed framework, an upper-abdominal physical phantom was constructed using agar to simulate background tissue conductivity. Hemispherical high-conductivity inclusions with volumes ranging from 10 ml to 50 ml were attached to the inner gastric wall to mimic localized bleeding under different gastric filling states. Boundary voltages were acquired under a 120 kHz excitation current and reconstructed using the TK-Noser-RCC algorithm. Furthermore, an in vivo animal experiment was performed using a porcine model with adult-scale abdominal dimensions. A total of 100 ml of autologous blood was injected incrementally into the stomach to simulate progressive gastric hemorrhage, and time-difference EIT reconstruction was conducted at each injection stage to assess the dynamic system response under physiological conditions. ResultsSimulation results demonstrated that the opposed dual-plane electrode array achieved superior depth sensitivity distribution and spatial resolution. For a 40 ml hemorrhage model, the average ICC and SSIM improved by 55.9% and 38.8% compared with the dual-layer ring configuration, and by 64.0% and 39.5% compared with the four-layer staggered configuration. The proposed region-clustering constraint significantly enhanced reconstruction stability. Under added Gaussian noise of 40 dB and 30 dB, ICC values remained approximately 0.85, indicating effective artifact suppression and preservation of boundary integrity. In physical phantom experiments, reconstructed hemorrhage volumes increased approximately linearly with the preset hemispherical volumes, and the reconstructed high-conductivity regions closely matched the actual bleeding locations. Both empty-stomach and full-stomach conditions were evaluated, demonstrating that the opposed dual-plane configuration maintained stable imaging performance across varying gastric contents. In the animal experiment, reconstructed low-impedance regions expanded progressively with increasing injected blood volume. The spatial localization of the hemorrhage remained stable throughout the procedure, and no significant artifacts were observed. Quantitative analysis showed that reconstructed volume and average conductivity variation exhibited an approximately linear growth trend with injected blood volume, confirming the sensitivity of the system to dynamic intragastric conductivity changes. ConclusionThe proposed 3D-gEIT framework enables quantitative reconstruction of gastric hemorrhage volume and spatial distribution with improved depth sensitivity, structural continuity, and noise robustness compared with conventional EIT approaches. By integrating optimized electrode configuration and a region-clustering-constrained reconstruction algorithm, the system provides stable dynamic monitoring under both controlled phantom conditions and in vivo physiological environments. This method offers a noninvasive, real-time, and low-cost imaging strategy for early diagnosis, postoperative monitoring, and bedside surveillance of gastric bleeding.
2.Mechanism of transcription factor ZEB1 in the proliferation, migration, and invasion of lung adenocarcinoma cells
Yun ZHAO ; Beibei MA ; Huaxue XING ; Shaofeng HUANG ; Zhongwei ZHANG ; Bo LING
Acta Universitatis Medicinalis Anhui 2026;61(3):470-479
ObjectiveTo investigate the effects of zinc finger E-box binding homeobox 1 (ZEB1) on the proliferation, migration, and invasion of lung adenocarcinoma H322 cells, as well as its underlying molecular mechanisms. MethodsThe gene expression characteristics of the transcription factor ZEB1 in lung adenocarcinoma were analyzed using data from the GEO and TCGA public databases. RT-qPCR and Western blot were employed to measure mRNA and protein expression levels of ZEB1 in lung adenocarcinoma cell lines (H322, A549, 95-D) and normal human bronchial epithelial cells (BEAS-2B). Lentiviral transduction was utilized to establish stable ZEB1-overexpressing (Oe-ZEB1) and vector control (Oe-NC) H322 cell lines. Cell proliferation was assessed using CCK-8, colony formation, and EdU assays, while apoptosis was evaluated by Hoechst33258/PI double staining. Wound healing and Transwell assays were performed to examine cell migration and invasion capabilities. Cell cycle distribution was determined by flow cytometry, and Western blot was used to analyze protein expression changes in relevant signaling pathways. ResultsThe findings from GEO and TCGA indicated that ZEB1 expression in lung adenocarcinoma varied with tumor malignancy grade. RT-qPCR and Western blot analyses revealed significantly higher ZEB1 expression in lung adenocarcinoma cell lines compared to BEAS-2B cells (P0.05). Results from the CCK-8, colony formation, EdU, wound healing, and Transwell assays demonstrated that, compared with the un-transfected control (Control) group, Oe-ZEB1 H322 cells exhibited enhanced proliferation, migration, and invasion capabilities (P0.05). Hoechst33258/PI double staining and flow cytometry analyses showed that, relative to the Control group, apoptosis was reduced in Oe-ZEB1 H322 cells (P0.05). Additionally, a decreased proportion of cells in the G1 phase and an increased proportion in the S phase were observed in Oe-ZEB1 cells, indicating accelerated cell cycle progression. Western blot analysis further revealed that, compared with the Control group, Oe-ZEB1 H322 cells exhibited upregulated expression of N-cadherin, mutant p53 (mutp53), and Cyclin D1 (P0.05), while expression levels of E-cadherin, murine double minute 2 (MDM2), and p21 were downregulated (P0.05). ConclusionOverexpression of ZEB1 promotes the proliferation, migration, and invasion of lung adenocarcinoma H322 cells and may facilitate cell cycle progression by modulating the MDM2/mutp53/p21 signaling pathway, thereby promoting the transition of cells from the G0/G1 phase to the S phase.
3.Application of Thermal Tomography in Breast Cancer Screening
Kankan ZHAO ; Bo CHEN ; Wenliang LU ; Yao CHENG ; Hongmei ZHENG ; Xinhong WU ; Shengrong SUN ; Ziming HUANG
Cancer Research on Prevention and Treatment 2025;52(5):388-392
Objective To evaluate the effectiveness of thermal tomography in breast cancer (BC) screening. Methods We conducted a general population-based BC screening in three regions of Hubei Province (Xiantao, Hongan, and Yangxin Districts). Participants underwent a questionnaire-based interview for baseline data collection. They then received a physical examination, thermal tomography, and ultrasound from doctors and technicians. We compared the efficacies, including sensitivity, specificity, and false-positive rates, of ultrasound and thermal tomography in BC screening. Results A total of 59 712 eligible women were included in this screening program. The BI-RADS 1, 2, 3, 4, and 5 accordance rates between the two screening methods were
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Clinical Value of a Novel Prognostic Prediction Model in Diffuse Large B-Cell Lymphoma.
Jie ZHAO ; Yan JIANG ; Jia-Yu LIU ; Rui LIU ; Jia-Qi LI ; Fang HUANG ; Jiang-Bo WAN ; Si-Guo HAO
Journal of Experimental Hematology 2025;33(3):789-795
OBJECTIVE:
To explore a predictive model that can better predict the prognosis of patients with diffuse large B-cell lymphoma (DLBCL), and validate its clinical value.
METHODS:
Clinical data of 134 newly treated DLBCL patients were collected from Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine from January 2015 to January 2020. Several risk factors of the patients were screened and analyzed, a novel prognostic model were then established based on this, and its clinical application potential was validated.
RESULTS:
In the novel model, predicting progression-free survival (PFS) based on the age at initial treatment, albumin level, Hans classification, Ann Arbor stage, and BCL2 expression showed better predictive performance than International Prognostic Index (IPI) score (AUC: 0.788 vs 0.620,P <0.001). Predicting overall survival (OS) based on the age at initial treatment, albumin level, lactate dehydrogenase (LDH) level, and expressions of BCL2 and MUM1 proteins also showed better predictive performance for mortality risk than IPI score (AUC: 0.817 vs 0.624,P <0.001).
CONCLUSION
This novel prognostic model can better predict the survival prognosis of DLBCL patients compared to the IPI scoring system.
Humans
;
Lymphoma, Large B-Cell, Diffuse/diagnosis*
;
Prognosis
;
Proto-Oncogene Proteins c-bcl-2/metabolism*
;
Risk Factors
;
Male
;
Female
;
Middle Aged
9.Pharmacological Mechanism of Chinese Medicine in Systemic Lupus Erythematosus: A Narrative Review.
Bo-Yu ZHU ; Zhi-Chao LIU ; Zhen-Xi ZHAO ; Hui-Ping HUANG ; Na ZHANG ; Jia XIA ; Wei-Wei CHEN
Chinese journal of integrative medicine 2025;31(2):157-169
Systemic lupus erythematosus (SLE) is a chronic autoimmune disorder affecting multiple systems, characterized by the development of harmful autoantibodies and immune complexes that lead to damage in organs and tissues. Chinese medicine (CM) plays a role in mitigating complications, enhancing treatment effectiveness, and reducing toxicity of concurrent medications, and ensuring a safe pregnancy. However, CM mainly solves the disease comprehensively through multi-target and multi-channel regulation process, therefore, its treatment mechanism is often complicated, involving many molecular links. This review introduces the research progress of pathogenesis of SLE from the aspects of genetics, epigenetics, innate immunity and acquired immunity, and then discusses the molecular mechanism and target of single Chinese herbal medicine and prescription that are commonly used and effective in clinic to treat SLE.
Lupus Erythematosus, Systemic/immunology*
;
Humans
;
Medicine, Chinese Traditional
;
Drugs, Chinese Herbal/pharmacology*
;
Animals
10.Establishment and evaluation of a lipopolysaccharide-induced acute respiratory distress syndrome model in minipigs
Chuang-Ye WANG ; Ran WANG ; Jian ZHANG ; Ling-Xiao QIU ; Bin QING ; Heng YOU ; Jin-Cheng LIU ; Bin WANG ; Nan-Bo WANG ; Jia-Yu LI ; Xing LIU ; Shuang WANG ; Jin HU ; Jian WEN ; Quan LI ; Xiao-Ou HUANG ; Kun ZHAO ; Shuang-Lin LIU ; Gang LIU ; Mei-Ju WANG ; Qing XIANG ; Hong-Mei WU ; Xiao-Rong SUN ; Tao GU ; Dong ZHANG ; Qi LI ; Zhi XU
Medical Journal of Chinese People's Liberation Army 2025;50(9):1154-1161
Objective To establish a stable,reliable,and clinically relevant porcine model of endotoxin-induced acute respiratory distress syndrome(ARDS).Methods Ten 8-month-old male Bama minipigs were deeply sedated,followed by invasive mechanical ventilation and electrocardiographic monitoring.Lipopolysaccharide(LPS)was intravenously pumped at 600 μg/(kg·h)for 3 hours,then maintained at 15 μg/(kg·h)thereafter.Dynamic monitoring was performed at five time points after LPS injection(LPS 0,1,3,5,and 8 h),including arterial blood gas analysis and chest computed tomography(CT)scans.Pathological examination of lung tissues obtained via bronchoscopic biopsy(HE staining and transmission electron microscopy)was conducted.These indicators were comprehensively used to evaluate the success of the animal model.Results At 5 hours after LPS administration,8 minipigs developed symptoms such as skin cyanosis,elevated body temperature,and respiratory distress.The oxygenation index decreased to<300 mmHg.Chest CT scans showed diffuse pulmonary infiltrates.Histopathology revealed alveolar edema and hyaline membrane formation.Transmission electron microscopy demonstrated disruption of pulmonary blood-air barrier,depletion of lamellar bodies in type Ⅱ pneumocytes,inflammatory cell infiltration,and exudation of plasma proteins and fibrin.Compared with LPS 0 h,at LPS 8 h,the oxygenation index and arterial blood pH were significantly decreased(P<0.001),while blood lactic acid and serum potassium were significantly increased(P<0.05);serum calcium and base excess were significantly decreased(P<0.05),and the lung injury score based on HE-stained lung sections was significantly increased(P<0.01).Conclusion The porcine ARDS model established by continuous LPS injection can dynamically simulate the pathophysiological characteristics and typical pathological manifestations of clinical septic ARDS,making it an effective tool to study the pathogenesis,prevention,and treatment strategies of septic ARDS.

Result Analysis
Print
Save
E-mail