1.The impact of 125I seeds strand length on different reference points dose
Ke XU ; Dingxin WANG ; Guozhang XING ; Huimin YU ; Jinxin ZHAO ; Zezhou LIU ; Zeyang WANG ; Hongtao ZHANG ; Juan WANG
Journal of Interventional Radiology 2025;34(6):609-613
Objective To investigate the effect of different strand lengths of 125I seeds with the same activity on the dose of different reference points around the seeds.Methods The scanned images were transferred to the three-dimensional treatment planning system(3D-TPS)according to DICOM format.The target volume was delineated at 5 mm and 10 mm above and below the center of the phantom,and a 0.8 mCi seeds strand was simulated.The 1-20 seeds were arranged with an equal spacing of 5 mm(5 mm-100 mm).The 5 mm points above and below the center of the seeds strand were defined as point A and point A',and the 10 mm points above and below the center were defined as point B and point B'.5 mm above and below the edge of the seeds strand on the left side were defined as AL points and AL'points,and 5 mm above and below the edge of the seeds strand on the right side were defined as AR points and AR'points.Similarly,points 10 mm above the above mentioned positions were defined as BL points,BL'points,BR points,BR'points.The average dose symmetry points were measured at AL,AL',AR,and 5 mm,10 mm,15 mm and 20 mm inside AR' of the 45 mm-100 mm seeds strand.The dose at the center was compared with the dose at the end points.The dose at the center point A was compared with the average dose at the symmetry points of 5 mm,10 mm,15 mm and 20 mm inside of the end points AL,AL',AR and AR',and the dose at each point was curve fitting.The correlation between each point and seeds strands of different lengths was analyzed.Results There was a positive correlation between the dose and the length of each point.There was no statistically significant difference between the center point and the end point.There was a statistically significant difference in dosage at points 5 mm and 10 mm inside from point A,while there was no statistically significant difference in dosage at points 15 mm and 20 mm inside from point A.The dose of A,A',B and B' point increased steadily with the increase of seed chain length,and the fitting curves were obtained respectively:y=e(-0.620/x+5.28)(R2=0.992),y=e(-0.640/x+5.34)(R2=0.987),y=e(-0.82/x+4.80)(R2=0.984),y=e(-0.82/x+4.83)(R2=0.9g1).Conclusion The doses at points A,A',B,and B'are positively correlated with seeds strand length and have a high degree of stability.Point A can be used as a reference point for the target area dose of the seeds strand,and point B can be used as a reference point for the dose to critical organs.The dose at other positions is more variable and thus has a certain degree of uncertainty as a reference point for the seeds strand dose.
2.Correlation between dose distribution and implantation duration of 125I seed strand under the simulated curvature of the cavity condition
Zezhou LIU ; Dingxin WANG ; Guozhang XING ; Jinxin ZHAO ; Ke XU ; Hongtao ZHANG ; Juan WANG
Journal of Interventional Radiology 2025;34(11):1213-1217
Objective To investigate the relationship between the absorbed dose and implantation duration at the target area and at the critical organ dose reference points in the application of radioactive 125I seed strands for the treatment of intraluminal tumors.Methods A self-developed 125I seed strand arc template with a 30-degree angle was used to place 10 seeds(each with activity of 1.0mCi)into the template.CT-based DICOM images were transferred to a treatment planning system(TPS)for dose calculation.Absorbed doses at multiple time points(from day 5 to day 90 with a 5-day interval)were measured at following four specific locations:point A'(5 mm inside the arc center),point A(5 mm outside the arc center),point B(10 mm outside the arc center),and point B'(10 mm inside the arc center).The TPS was first used to calculate the expected absorbed doses,followed by actual absorbed dose measurements over the 90-day period.The expected absorbed doses were calculated,and then the actual absorbed doses were calculated.The time-dose relationship of the above points was analyzed,and the curves and equations were obtained.Results The expected absorbed doses at points A',A,B,and B'were 221.36,196.39,115.78,and 136.32 Gy,respectively.The time(x)-dose(y)relationships of all the above points followed a quadratic function relationship in the form of y=c+bx-ax2.Within the time range of 5-90 days,the actual absorbed dose increased with the prolongation of time,and the increase speed showed a pattern of first fast and then slow.The increase in speed was fast within 20 days,than became stable between 20-75 days,and after 75 days the increase in speed became to slow down.Conclusion When using 125I seed strands to treat intraluminal tumors,the actual absorbed dose of the tumor needs to be accurately calculated based on the implantation duration.The actual absorbed dose initially accumulates rapidly and decreases significantly after 75 days.It is recommended to replace the 125I seed strand with a new one after implanting it for approximately 75 days.
3.The impact of 125I seeds strand radian on the dose of different reference points
Jinxin ZHAO ; Dingxin WANG ; Guozhang XING ; Ke XU ; Zezhou LIU ; Huimin YU ; Zeyang WANG ; Juan WANG ; Hongtao ZHANG
Journal of Interventional Radiology 2025;34(12):1333-1337
Objective To investigate the impact of different 125I seeds strand radian on the dose of different reference points around the seeds.Methods CT scan of self-developed radioactive particle radiation dose measurement phantom was performed,the scanned images were transferred to the three-dimensional treatment planning system(TPS).The target area at the middle level of the model was drawn.The target volume was delineated at 5 mm and 10 mm above and below the center of the phantom.125I seeds strand plans were designed with different radians,with a total length of 8 cm,seed spacing of 0 cm,activity of 0.8 mCi,and a total of 16 particles,with radians ranging from 30°to 170°,increasing by 10° increment.The point 5 mm vertically away from the center of the seeds strand towards the center was named A',and the point away from the center was named A.The point 10 mm vertically away from the center of the seeds strand towards the center was named B',and the point away from the center was named B.The doses at different radians were recorded,and the actual absorbed dose at 1-2 months after operation was calculated based on the particle activity decay formula.Results The doses at points A'and A were(218.3±23.1)and(201.5±16.0)Gy respectively(P=0.001).The actual absorbed doses at 1 month after operation were(65.5±6.9)and(60.5±4.8)Gy respectively(P=0.001),and the actual absorbed doses at 2 months after operation were(109.2±11.5)Gy and(100±7.9)Gy respectively(P=0.001).The doses at points B'and B were(95.9±11.0)Gy and(81.7±4.9)Gy respectively(P<0.001),and the actual absorbed doses at 1 month after operation were(28.8±3.3)Gy and(24.5±1.5)Gy respectively(P<0.001).The actual absorbed doses at 2 month after operation were(48.0±5.5)Gy and(41.0±2.4)Gy respectively(P<0.001).The doses at points A'and A gradually decreased with the increase of the radians,reaching the minimum value at 100 degrees,and then increased gradually,showing a cubic function change.The actual absorbed dose showed the same trend.The doses at points B'and B increased gradually with the increase of the radians,showing a cubic function change.Conclusion At different radians,the point doses and absorbed doses on the centrifugal side of the seeds strand are both less than those on the centripetal side.There is a cubic function relationship between the dose at the reference points and the radian of the seeds strand.
4.Dosimetric analysis of radiation pneumonitis induced by 125I seed implantation for the treatment of malignant lung tumors
Ke XU ; Jinxin ZHAO ; Zezhou LIU ; Yansong LIANG ; Guohui CAO ; Xiaoli LIU ; Yan DI ; Juan WANG ; Hongtao ZHANG
Chinese Journal of Radiological Medicine and Protection 2024;44(1):13-17
Objective:To investigate the incidence of radiation pneumonitis (RP) induced by 125I seed implantation for the treatment of malignant lung tumors and analyze related dosimetric parameters. Methods:A retrospective analysis was conducted on 31 cases of malignant lung tumors treated with 125I seed implantation from January 2017 to December 2022 at Hebei Provincial Tumor Radioactive Seeds Implantation Diagnosis and Treatment Center. These cases consisted of eight patients with squamous cell carcinoma, 10 patients with adenocarcinoma, and 13 patients with metastatic cancer in other sites. At 1-6 months after treatment, these patients received postoperative chest CT scans, with the efficacy evaluated based on the Response Evaluation Criteria in Solid Tumors version 1.1 (RECIST 1.1), including the objective response rate (ORR) and the disease control rate (DCR). The efficacy of RP was evaluated using the Radiation Therapy Oncology Group (RTOG) criteria. Postoperative dosimetric parameters, including D90 (minimum peripheral dose received by 90% of the target volume), V8 (percentage of lung volume receiving 8 Gy), V32 (percentage of lung volume receiving 32 Gy), and Dmean (mean radiation dose) of the affected lung, were statistically analyzed. The relationships of the RP occurrence with postoperative D90, V8, V32, and Dmean were analyzed by comparison with relevant external radiotherapy data, to identify the parameters that are correlated closely with RP occurrence. Results:All the patients underwent successful surgeries. The postoperative efficacy evaluation after six months showed complete response (CR) in 11 cases, partial response (PR) in 11 cases, stable disease (SD) in eight cases, and progressive disease (PD) in one case, with an overall response rate (ORR) of 71.0%, and a disease control rate (DCR) of 96.8%. Three patients suffered RP, with an incidence rate of 9.7%. Postoperative V8, V32, and Dmean could not serve as predictive indicators for RP. Follow-up observation revealed that three RP cases (3/5) exhibited postoperative D90 exceeding 170 Gy and no RP cases (0/26) showed postoperative D90 below 170 Gy. Conclusions:In the treatment of malignant lung tumors with 125I seed implantation, there is a certain correlation between RP and postoperative D90, while there is no correlation between it and V8, V32, and Dmean.
5.Relationship of actual absorbed dose and volumetric change in patients with squamous cell carcinoma of thyroid treated by 125I radioactive seeds
Zezhou LIU ; Juan WANG ; Hongtao ZHANG ; Yansong LIANG ; Zhen GAO ; Jinxin ZHAO ; Ke XU ; Huijuan LI ; Huiming YU
Chinese Journal of Endocrine Surgery 2022;16(1):50-53
Objective:To investigate the relationship between dosimetric parameters and tumor volume change after 125I implantation for thyroid cancer and obtain better dosimetric parameters that predict the curative effect more accurately. Methods:A total of 22 consecutive patients with thyroid cancer (23 targets) who received 125I interstitial brachytherapy in Department of Oncology, Hebei General Hospital were retrospectively analyzed. All the patients received post-operative dose verification, and the D 90 (Minimum dose received by 90% target volume) was calculated. After a regular follow-up, the tumor volume reduction ratio after t months (R t) , actual absorbed dose (D 1m) , efficacy corrected absorbed dose (D 1e) , and sensitivity corrected absorbed dose (D 1s) of the first month were calculated according to the actual follow-up CT images. The statistical test was carried out by SPSS21.0. The Spearman linear analysis was applied to analyze the relationship between D 90, D 1m, D 1e, D 1s and R t, and the curve fitting was also completed. Results:The post-operative D 90, D 1m, D 1e, D 1s and R t were (129.73±14.22) Gy, (36.95±7.35) Gy, (43.45±11.32) Gy, (41.78±13.39) Gy, and (32.00±19.00) %, respectively. And the correlation coefficient were 0.692, 0.551, 0.728, and 0.858, respectively, which showed significant positive relevance between dosimetric parameters and tumor volume change ( P<0.01) , the curve fitting presented cubic function. Conclusion:The post-operative D 90, D 1m, D 1e, and D 1s can be predictors for curative effect, and D 1s is the best predictor.
6.Systems Pharmacology-based Analysis of Anti-tumor Mechanism of Houttuynia cordata
Yuru ZHANG ; Xuping TIAN ; Zezhou ZHAO ; Wei XIAO ; Yonghua WANG
Chinese Journal of Experimental Traditional Medical Formulae 2022;28(14):165-171
ObjectiveTo explore the effective components, targets, and mechanism of Houttuynia cordata against lung cancer by means of systems pharmacology and further to provide a reference for the further development and clinical application of this medicinal. MethodChemical components of H. cordata were retrieved from Traditional Chinese Medicine Systems Pharmacology Database and Analysis Platform (TCMSP) and the active components were screened based on oral bioavailability (OB) and drug-likeness (DL). Then the potential targets were predicted, followed by enrichment analysis. Finally, sodium houttuyfonate (SH) was selected for verifying the anti-tumor mechanism. Cell counting kit-8 (CCK-8) assay was used to evaluate the effect of SH on the in vitro proliferation of two lung cancer cell lines: A549 and LLC, and the regulation of tumor-related proteins by SH was verified by Western blot. ResultA total of 7 active compounds and 352 targets of the active components were screened out. According to the enrichment analysis of targets, H. cordata had potential therapeutic effects on cancer. SH had inhibitory effect on both A549 and LLC. Western blot results showed that G1/S-specific Cyclin D1, E1 and cyclin-dependent kinase (CDK)2, CDK4 all tended to be down-regulated, and Janus kinase 2 (JAK2)/signal transducer and activator of transcription 3 (STAT3) also changed significantly. ConclusionH. cordata has the potential anti-tumor effects by arresting the tumor cells in the G1 phase through the JAK2/STAT3 pathway.
7. Factors influencing the short-term efficacy of CT-guided 125I seeds implantation in the treatment of recurrent and metastatic tumors of head and neck
Enli CHEN ; Hongtao ZHANG ; Zezhou LIU ; Jinxin ZHAO ; Ke XU ; Yansong LIANG ; Aixia SUI ; Juan WANG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2020;40(2):93-97
Objective:
To analyze the factors influencing the short-term efficacy of CT-guided 125I seeds implantation in the treatment of recurrent and metastatic tumors in head and neck.
Methods:
A total of 73 patients (61 males, 12 females; age: (59.1±11.5) years) with head and neck tumors recurrence and metastasis treated by 125I seeds implantation in Hebei General Hospital from January 2015 to April 2019 were retrospectively enrolled. The implanted seeds activity was 11.1-29.6 MBq, and the prescription dose was 80.0-145.0 Gy. CT examination was conducted 3 months after 125I seeds implantation. According to Response Evaluation Criteria in Solid Tumors (RECIST) 1.1, short-term efficacy was classified as effective (complete remission (CR), partial remission (PR)) and ineffective (stable disease (SD), progressive disease (PD)). Univariate analysis of factors affecting short-term effect (gender, age, history of radiation therapy, Karnofsky performance status (KPS) scores, pathological type, the longest diameter of tumor, implantation patterns, seeds activity, immediate postoperative dose delivered to 90% gross tumor volume (
8.Relationship between the peripheral dose and radioactive counts of 125I seeds detected by SPECT/CT
Xianzhi ZHAO ; Hongtao ZHANG ; Xuemin DI ; Shuangchen YANG ; Chen ZHANG ; Jinxin ZHAO ; Zezhou LIU ; Huimin YU ; Juan WANG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2017;37(6):351-354
Objective To explore the relationship between the peripheral dose and radioactive counts of 125I seeds detected by SPECT/CT.Methods Six 125I seeds(1.48×107 Bq, 1.85×107 Bq, 2.22×107 Bq, 2.59×107 Bq, 2.96×107 Bq, 3.33×107 Bq) were put into the solid water phantoms respectively. SPECT/CT was applied to scan the seeds. The radioactive counts (x) at the distance of 1-15 mm from the center of seeds were recorded respectively, while the corresponding doses (y, cGy) were calculated. SPSS 18.0 was used to analyze the relationship between the radioactive counts and peripheral dose. Results There was an exponential relationship between the peripheral dose of 125I seeds and the radioactive counts. The formula was as follow: y=507.849×1.004x. Conclusion SPECT/CT can visualize the peripheral dose of 125I seed, which may provide a method for dosimetric verification after brachytherapy.
9.Dosimetric research on 125I seeds arranged in different spacing by using film dosimeter
Xuemin DI ; Hongtao ZHANG ; Jinxin ZHAO ; Zezhou LIU ; Shulei NIU ; Sui DU ; Juan WANG
Journal of Interventional Radiology 2017;26(12):1122-1125
Objective To investigate the dosimetric effect of same activity and same number of 125I seeds arranged in axial train but with different spacing.Methods A total of 27 film dosimeters were randomly and equally divided into group A,B and C.Each film was irradiated by three 125I seeds (activity of 1.48×107 Bq).The seeds were arranged in line,and their axial spacing was 1 mm,5 mm and 10 mm respectively.Image analysis software was used to draw iso-gray contour curves of 20,25,30 and 40 gray value on the films,and to calculate the areas contained by each curve.Results Multi-sample mean comparison variance analysis showed that the differences in area contained by 20 and 25 iso-gray contour curves were statistically significant between each other among the three groups (P<0.001).The difference in area contained by 30 iso-gray contour curve between group A and group B was not statistically significant (P> 0.05),while the difference in area contained by 30 iso-gray contour curve between group A and group C as well as between group B and group C was statistically significant (P<0.001).No statistically significant difference in area contained by 40 iso-gray contour curve existed between each other among the three groups (P=0.99).Conclusion Different spacing arrangement of same activity and same number of 125I seeds can directly influence the peripheral dose distribution.In specific dose range,seed-spacing of 1 mm arrangement may obtain better dose distribution than seed-spacing of 5 mm or 10 mm arrangement can do.

Result Analysis
Print
Save
E-mail