1.Clinical research and application status of cervical sagittal parameters C 2-C 7 SVA
Zerui QIN ; Yu RAN ; Zongshuo SHA ; Xiaohong MU ; Jinyu LI ; Jiang CHEN
Chinese Journal of Orthopaedics 2025;45(7):454-462
The C 2-C 7 sagittal vertical axis (SVA) is an essential biomechanical parameter for evaluating cervical spine alignment, and it is integral to the pathogenesis, progression, and prognosis of cervical spine disorders. This parameter is widely used in evaluating cervical sagittal balance and functional status. Internationally, a C 2-C 7 SVA of less than 25 mm is considered within the cervical range for sagittal balance, while values exceeding 40 mm indicate cervical sagittal imbalance or deformity. An increased C 2-C 7 SVA disrupts cervical spine biomechanics, leading to heightened static and dynamic loads on the cervical musculature. This, in turn, results in muscle fatigue and discomfort. In the short term, patients may experience axial neck symptoms, while a sustained elevation in SVA over time significantly raises the risk of cervical disc degeneration, radiculopathy, and myelopathy. Additionally, a higher C 2-C 7 SVA postoperatively places excessive stress on adjacent spinal segments, which can accelerate degeneration of intervertebral discs and facet joints, contributing to adjacent segment degeneration. Both short-term and long-term postoperative evaluations have shown that an increase in C 2-C 7 SVA is typically associated with poorer surgical outcomes, whereas effective control of SVA values is closely linked to better functional recovery. Therefore, in clinical practice, maintaining C 2-C 7 SVA within the normal range (<25 mm) is critical not only for optimizing treatment results but also for significantly reducing postoperative complications and improving overall patient quality of life.
2.Clinical research and application status of cervical sagittal parameters C 2-C 7 SVA
Zerui QIN ; Yu RAN ; Zongshuo SHA ; Xiaohong MU ; Jinyu LI ; Jiang CHEN
Chinese Journal of Orthopaedics 2025;45(7):454-462
The C 2-C 7 sagittal vertical axis (SVA) is an essential biomechanical parameter for evaluating cervical spine alignment, and it is integral to the pathogenesis, progression, and prognosis of cervical spine disorders. This parameter is widely used in evaluating cervical sagittal balance and functional status. Internationally, a C 2-C 7 SVA of less than 25 mm is considered within the cervical range for sagittal balance, while values exceeding 40 mm indicate cervical sagittal imbalance or deformity. An increased C 2-C 7 SVA disrupts cervical spine biomechanics, leading to heightened static and dynamic loads on the cervical musculature. This, in turn, results in muscle fatigue and discomfort. In the short term, patients may experience axial neck symptoms, while a sustained elevation in SVA over time significantly raises the risk of cervical disc degeneration, radiculopathy, and myelopathy. Additionally, a higher C 2-C 7 SVA postoperatively places excessive stress on adjacent spinal segments, which can accelerate degeneration of intervertebral discs and facet joints, contributing to adjacent segment degeneration. Both short-term and long-term postoperative evaluations have shown that an increase in C 2-C 7 SVA is typically associated with poorer surgical outcomes, whereas effective control of SVA values is closely linked to better functional recovery. Therefore, in clinical practice, maintaining C 2-C 7 SVA within the normal range (<25 mm) is critical not only for optimizing treatment results but also for significantly reducing postoperative complications and improving overall patient quality of life.
3.Intrinsic steady-state pattern of mouse cardiac electrophysiology:analysis using a characterized quantitative electrocardiogram strategy
Siyi CHENG ; Zerui CHEN ; Changjiang YU ; Tucheng SUN ; Shuoji ZHU ; Nanbo LIU ; Ping ZHU
Journal of Southern Medical University 2024;44(10):1985-1994
Objective To explore the intrinsic steady-state electrophysiological properties of mouse heart under physiological conditions by high-resolution quantitative analysis.Methods Twenty-two young adult C57BL/6 mice with a 1:1 male-to-female ratio were used.The limbs of the mice were fixed without anesthesia,and electrocardiographic waveforms,including characteristic P-waves,R-waves,and ST-waves,were recorded using a sensitive 12-lead electrophysiological recorder(ECGsqa)under spontaneous breathing.LabScribe software was used to extract and quantify high-resolution time course and amplitude parameters within a single cardiac cycle from the V3 precordial lead.Pearson correlation test combined with simple linear regression was used to generate a scatter plot of ECG parameter fitting.The common and unique correlation parameters were separately identified by joint associations for profiling the quantitative association network.Results ECGsqa analysis identified and quantified 14 characteristic ECG parameters,28.6%of which showed statistical differences between the groups.Compared to male mice,female mice exhibited higher amplitudes and velocities of R and ST waves.Among the 51 association pairs identified in primary association analysis,47.1%were positively correlated,including shared(29.2%),male-specific(29.2%),and female-specific(41.7%)association groups.Second-order clustering of the association pairs revealed that the amplitude-rate association pairs of each waveform voltage in both male and female mouse hearts were strongly correlated.The male mice showed an atrioventricular interconnection pattern,while the female mice showed a unique atrial conduction system quality dependence.The distribution network characteristics of the association groups showed that sex-specific and common correlation sets formed a certain series pattern.Conclusion We discovered a novel intrinsic correlation network of cardiac electrophysiological traits in male and female mice,which reveals the key internal quantitative characteristics and gender difference of both atrial and ventricular conduction systems.
4.Intrinsic steady-state pattern of mouse cardiac electrophysiology:analysis using a characterized quantitative electrocardiogram strategy
Siyi CHENG ; Zerui CHEN ; Changjiang YU ; Tucheng SUN ; Shuoji ZHU ; Nanbo LIU ; Ping ZHU
Journal of Southern Medical University 2024;44(10):1985-1994
Objective To explore the intrinsic steady-state electrophysiological properties of mouse heart under physiological conditions by high-resolution quantitative analysis.Methods Twenty-two young adult C57BL/6 mice with a 1:1 male-to-female ratio were used.The limbs of the mice were fixed without anesthesia,and electrocardiographic waveforms,including characteristic P-waves,R-waves,and ST-waves,were recorded using a sensitive 12-lead electrophysiological recorder(ECGsqa)under spontaneous breathing.LabScribe software was used to extract and quantify high-resolution time course and amplitude parameters within a single cardiac cycle from the V3 precordial lead.Pearson correlation test combined with simple linear regression was used to generate a scatter plot of ECG parameter fitting.The common and unique correlation parameters were separately identified by joint associations for profiling the quantitative association network.Results ECGsqa analysis identified and quantified 14 characteristic ECG parameters,28.6%of which showed statistical differences between the groups.Compared to male mice,female mice exhibited higher amplitudes and velocities of R and ST waves.Among the 51 association pairs identified in primary association analysis,47.1%were positively correlated,including shared(29.2%),male-specific(29.2%),and female-specific(41.7%)association groups.Second-order clustering of the association pairs revealed that the amplitude-rate association pairs of each waveform voltage in both male and female mouse hearts were strongly correlated.The male mice showed an atrioventricular interconnection pattern,while the female mice showed a unique atrial conduction system quality dependence.The distribution network characteristics of the association groups showed that sex-specific and common correlation sets formed a certain series pattern.Conclusion We discovered a novel intrinsic correlation network of cardiac electrophysiological traits in male and female mice,which reveals the key internal quantitative characteristics and gender difference of both atrial and ventricular conduction systems.
5.Eearly outcomes of totally thoracoscopic minimally invasive aortic valve and double valve replacement
Zhenzhong WANG ; Yanchen YANG ; Huanlei HUANG ; Lishan ZHONG ; Chengnan TIAN ; Zerui CHEN ; Biaochuan HE ; Xin ZANG ; Junfei ZHAO ; Huiming GUO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2023;30(05):710-717
Objective To summarize the early outcomes of totally thoracoscopic minimally invasive aortic valve replacement (AVR) and double valve replacement (DVR). Methods The clinical data of patients who underwent totally thoracoscopic minimally invasive AVR or DVR in Guangdong Provincial People’s Hospital from April 2020 to January 2021 were retrospectively analyzed. The patients were divided into an AVR group and a DVR group according to the surgical method, and the clinical data of the two groups were compared. Results Finally 22 patients were enrolled, including 14 males and 8 females with an average age of 50.0±11.2 years at operation. Eight patients were degenerative disease, 8 were rheumatic heart disease combined with valvular disease, and 6 were bicuspid aortic valve. Out of the 22 patients, 16 underwent AVR alone, and 6 underwent DVR. All patients completed the operation successfully, and there was no death. Perivalvular leakage during surgery occurred in 2 patients. The average cardiopulmonary bypass time was 187.0±39.9 minutes, and aortic cross-clamping time was 117.0 (99.0, 158.0) minutes. Duration of mechanical ventilation and intensive care unit stay was 9.5 (4.8, 18.3) hours and 41.0 (34.0, 64.0) hours, respectively. The volume of chest drainage at the first 24 hours after surgery was 214.0±124.6 mL, and the postoperative hospital stay was 5.5 (4.0, 8.3) days. The cardiopulmonary bypass time and aortic cross-clamping time in the DVR group were longer than those in the AVR group, and the volume of chest drainage at 24 hours after surgery was more than that in the AVR group, with a statistical difference (P<0.05). Echocardiography before hospital discharge showed paravalvular leakage in 1 patient. There was no death during follow-up of 5.9±3.0 months. Conclusion The early outcome of totally thoracoscopic minimally invasive AVR and DVR is satisfactory, and the approach of surgery is worth exploring.
6.Surgical versus conservative treatment for acute type A aortic intramural hematoma: A retrospective cohort study
Jue YANG ; Changjiang YU ; Xin LI ; Zerui CHEN ; Fei XIAO ; Tucheng SUN ; Ruixin FAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2023;30(05):718-723
Objective To compare the outcomes following emergency surgery or conservative treatment for patients with acute type A aortic intramural hematoma (IMH). Methods Clinical data of consecutive patients diagnosed with acute type A aortic IMH in our hospital from September 2014 to December 2018 were retrospectively analyzed. The patients who met our surgical indications received surgery (an operation group) and other patients received strict conservative treatment (a conservative treatment group). Results Finally 127 patients were enrolled, including 112 males and 15 females with an average age of 53.6±13.0 years. Of 127 patients, 85 (66.9%) patients accepted emergency surgery and 42 (33.1%) patients accepted strict conservative treatment. There was no difference between the two groups in early mortality or complications (P>0.05). The 5-year survival rate was 90.4% in the operation group and 74.3% in the conservative treatment group (P=0.010). A maximum aortic diameter in the ascending aorta and aortic arch≥45 mm and maximum thickness of IMH in the same section≥8 mm were risk factors for IMH-related death in patients undergoing conservative treatment (P<0.001). Conclusion The mortality associated with emergency surgery for patients with acute type A aortic IMH is satisfactory. In clinical centers with well-established surgical techniques and postoperative management, emergency surgical treatment may provide a better outcome than conservative treatment for patients with acute type A aortic IMH.
7.Early outcomes of transapical mitral valve-in-valve procedure
Xujing XIE ; Lifu LI ; Huanlei HUANG ; Jian LIU ; Biaochuan HE ; Zerui CHEN ; Junfei ZHAO ; Huiming GUO ; Jimei CHEN
Chinese Journal of Thoracic and Cardiovascular Surgery 2021;37(10):600-605
Objective:To summarize the experience and early outcomes of transapical mitral valve-in-valve procedure with J-Valve in patients with bioprostheses degeneration.Methods:The clinical data of 29 patients who underwent mitral transcatheter valve-in-valve implantation with J-Valve from April 2020 to March 2021 were retrospectively analyzed. There were male 16 and female 13 patients with average age (72.0±11.6) years. Patients underwent previous mitral valve replacement with bioprostheses of Hancock Ⅱ in 17, Edwards SAV in 7, Edwards Perimount in 3, Balmedic in 1, Mosaic in 1. The size of mitral bioprostheses included 25 # for 8 patients, 27 # for 17 patients, and 29 # for other 4 patients. The operations were performed in the hybrid operation room. Under X-ray fluoroscopy and TEE monitoring, the retro-preseted J-valve was implanted into the mitral bioprosthetic valve via the intercostal space and apical puncture. Results:One patient was converted urgently to mediate sternotomy, and the transcatheter mitral valve was reset after opening left atrium on cardiopulmonary bypass due to the migration of transcatheter valve. twenty eight patients were successfully completed transcatheter mitral valve-in-valve procedure with technical success achieving in 96.6% . Among the 28 patients who successfully were completed valve-in-valve procedure, 1 died and 27 were discharged in well condition. The mean mitral transvalvular gradient was (7.6±2.2)mmHg(1 mmHg=0.133 kPa), no death or other major complications occurred during the follow-up.Conclusion:The application of J-Valve interventional valve in patients with bioprosthesis degeneration can achieve favourable early outcomes, even if the patient was replaced with a small bioprosthesis in the previous operation, the hemodynamic effect was still satisfactory.
8.Application of Neoadjuvant Immuno-chemotherapy in NSCLC.
Si CHEN ; Zerui ZHAO ; Hao LONG
Chinese Journal of Lung Cancer 2021;24(4):284-292
Even patients after standard surgery and adjuvant chemotherapy still have a high risk of recurrence and metastasis. With the success of immunotherapy in advanced non-small cell lung cancer (NSCLC), the application of immunotherapy in locally advanced NSCLC has being investigated to reduce the recurrence and metastasis. Pre-clinical studies and several phase II clinical studies had provided theoretical support and clinical evidence for neoadjuvant immunotherapy for NSCLC. This review describes the mechanism of neoadjuvant immuno-chemotherapy, summarizes up-to-date clinical studies, and analyzes efficiency and feasibility of neoadjuvant immune monotherapy or immuno-chemotherapy. Results from four studies (NCT02259621, NEOSTAR, LCMC3 and ChiCTR-OIC-17013726) showed efficiency and feasibility of neoadjuvant anti-programmed cell death 1 (PD-1)/programmed cell death ligand 1 (PD-L1) monotherapy. Neoadjuvant nivolumab plus ipilimumab achieved higher major pathological response rate than nivolumab monotherapy. However, the combination of nivolumab plus ipilimumab led to more severe adverse events as is seen in the NEOSTAR trial. Results from NCT02716038, SAKK 16/14 and NADIM studies suggest that the pathological response rate of neoadjuvant immune-chemotherapy is higher than neoadjuvant immune checkpoint inhibitor monotherapy. This review also elaborates the mechanism of chemotherapy combined with immunotherapy, and discusses the efficacy evaluation after neoadjuvant immunotherapy.
.
9. The mid-term outcomes of minimally invasive plasty for severe tricuspid regurgitation after cardiac surgery
Huanlei HUANG ; Yingjie KE ; Liang YANG ; Qian YAN ; Biaochuan HE ; Kan ZHOU ; Zerui CHEN ; Huiming GUO ; Cong LU ; Jing LIU ; Jinsong HUANG
Chinese Journal of Surgery 2019;57(12):902-907
Objectives:
To evaluate the efficacy of minimally invasive surgery in patients with late severe tricuspid regurgitation after cardiac surgery, and to evaluate the role of leaflets augmentation technique in tricuspid valvuloplasty.
Methods:
From January 2015 to June 2019, 85 patients undergoing tricuspid valve repair procedure with minimally invasive approach at Department of Cardiovascular Surgery, Guangdong provincial People′s Hospital were enrolled. There were 22 males and 63 females, aging of (53.6±12.4) years (range: 15 to 75 years). The interval between the prior and current operations was (16.0±7.3) years (range: 0.2 to 35.0 years). The diameter of right atrium and right ventricle was (77.3±17.2) mm and (61.0±8.4) mm, respectively. Tricuspid regurgitation was severe or extremely severe, the tricuspid regurgitation area was (19.0±10.3) cm2. All patients underwent minimally invasive tricuspid valvuloplasty or tricuspid valve replacement on beating-heart with totally endoscopic technique and port-access approach through right chest wall. The operations included tricuspid valve replacement and tricuspid valvuloplasty, the technique of tricuspid valvuloplasty including leaflets augmentation with patch, ring implantation, chordae tendineaes reconstruction, release of papillary muscle, edge to edge method, etc. Postoperative hospitalization days, the time of ICU stay, blood transfusion rate, ventilator time and the results of echocardiography were recorded. Follow-up was completed regularly by WeChat, telephone and outpatient visit.
Results:
Sixty-five patients underwent tricuspid valve repair, and 20 patients underwent tricuspid valve replacement because of prosthetic failure and plasty failure. Five patients died during hospitalization, with mortality rate 5.9%. One patient was transferred to local hospital for anti-infection treatment, the other 79 patients were discharged from hospital in well condition and followed-up. The postoperative hospitalization time was 7.0 (5.5) days (
10.The application of minimally invasive tricuspid valvuloplasty technique with patch augmentation in reoperative cardiac surgery
KE Yingjie ; CHEN Zerui ; HUANG Huanlei ; ZENG Qingshi ; GUO Huiming ; HUANG Jingsong ; LIU Jing ; LIU Jian ; ZHANG Xiaohua ; LU Cong
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2018;25(7):577-582
Objective To evaluate the efficacy of a combination of beating-heart minimally invasive approach and leaflets augmentation technique treating severe tricuspid regurgitation (TR) after cardiac surgery. Methods From January 2015 to August 2017, patients undergoing reoperative tricuspid valve repair (TVP) with minimally invasive approach and leaflets augmentation were enrolled. Cardiopulmonary bypass (CPB) was established via femoral vessels and the procedures were performed on beating heart with normothermic CPB. A bovine pericardial patch was sutured to leaflets to augment the native anterior and posterior leaflets. Other repair techniques, such as ring implantation and leaflet mobilization, were also applied as needed. Results A total of 28 patients (mean age 55.6±10.1 years, 5 males, 23 females) were enrolled. One patient was converted to median sternotomy due to pleural cavity adhesion. Twenty-seven patients underwent totally endoscopic TVP with leaflets augmentation. No patients was transferred to tricuspid valve replacement. Two patients died in hospital. All patients were followed up for 7.4±5.0 months and there was no late death and reoperation. Regurgitation area was converted from 20.7±10.1 cm2 to 3.3±3.3 cm2 after TVP according to the latest echocardiography (P<0.001). Conclusion Minimally TVP with leaflets augmentation is effective in treating severe isolated TR after primary cardiac surgery. It can significantly increase success rate of tricuspid valvuloplasty and decrease the surgical trauma.

Result Analysis
Print
Save
E-mail