1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.An Attention-weighted Tri-modal Ultrasound Network (TUS-Net) for Screening of Atypical Hepatocellular Carcinoma From LR-M Liver Nodules
He-Chong ZHANG ; Liang-Hui HUANG ; Xue-Hua WANG ; Shang-Lin JIANG ; Ying-Ying CHEN ; Ya-Guang ZENG ; Wei ZHENG
Progress in Biochemistry and Biophysics 2026;53(5):1485-1498
ObjectiveDiscriminating atypical hepatocellular carcinoma (HCC) from other malignancies in liver nodules classified as Liver Imaging Reporting and Data System category M (LR-M) remains a significant diagnostic challenge on conventional ultrasound examination. The LR-M category, originally intended to capture non-HCC malignancies, paradoxically contains up to 63% of atypical HCCs that deviate from classic enhancement patterns, leading to potential misdiagnosis and suboptimal treatment planning. While deep learning has shown promise in HCC diagnosis, most existing models rely exclusively on single-modality ultrasound, overlooking the diagnostic benefits of integrating complementary information from multiple imaging sources. To address this gap, we propose a novel attention-weighted tri-modal ultrasound network (TUS-Net) that integrates contrast-enhanced ultrasound (CEUS), B-mode ultrasound (BUS), and time-intensity curves (TICs) to improve diagnostic accuracy for these clinically challenging lesions. MethodsOur framework incorporates a three-dimensional convolutional neural network (C3D) backbone to extract spatiotemporal features from CEUS videos, capturing dynamic vascular patterns critical for lesion characterization. To effectively fuse complementary modalities, we introduce a dual-channel feature fusion module (DCFFM) that adaptively combines features from CEUS and BUS through channel-wise attention mechanisms, allowing the model to dynamically weigh the contribution of each modality based on diagnostic relevance. Additionally, we propose a temporal intensity feature fusion module (TIFFM) that leverages quantitative hemodynamic information from TICs to guide the model’s attention toward diagnostically critical temporal phases, such as arterial wash-in and portal venous washout. The model is further enhanced by automated lesion localization using YOLOX and class activation mapping for interpretability, ensuring that predictions align with clinically meaningful imaging features. ResultsEvaluated on a tri-modal ultrasound dataset comprising 161 patients with pathologically confirmed LR-M nodules (131 atypical HCC and 30 non-HCC malignancies), our model achieved an accuracy of 86.83%, a sensitivity of 92.50%, a specificity of 75.50%, and an AUC of 89.32% in screening atypical HCC. Compared to single-modality baselines, TUS-Net demonstrated superior specificity, a clinically critical metric given the higher risk associated with misclassifying non-HCC malignancies. Ablation studies confirmed the contribution of each module, with the full model outperforming both standard C3D and 3D ResNet backbones integrated with attention mechanisms. A reader study involving junior and senior radiologists further validated the clinical utility of AI assistance, showing consistent improvements in specificity and inter-reader consistency, particularly for less experienced clinicians. ConclusionThese results surpass existing benchmark models and demonstrate the potential of our approach to enhance diagnostic precision in clinically specific cases. By intelligently fusing multi-modal ultrasound data with attention-guided mechanisms, TUS-Net offers a reliable and interpretable tool that holds promise for improving the non-invasive diagnosis of atypical HCC in challenging LR-M liver nodules.
3.An Attention-weighted Tri-modal Ultrasound Network (TUS-Net) for Screening of Atypical Hepatocellular Carcinoma From LR-M Liver Nodules
He-Chong ZHANG ; Liang-Hui HUANG ; Xue-Hua WANG ; Shang-Lin JIANG ; Ying-Ying CHEN ; Ya-Guang ZENG ; Wei ZHENG
Progress in Biochemistry and Biophysics 2026;53(5):1485-1498
ObjectiveDiscriminating atypical hepatocellular carcinoma (HCC) from other malignancies in liver nodules classified as Liver Imaging Reporting and Data System category M (LR-M) remains a significant diagnostic challenge on conventional ultrasound examination. The LR-M category, originally intended to capture non-HCC malignancies, paradoxically contains up to 63% of atypical HCCs that deviate from classic enhancement patterns, leading to potential misdiagnosis and suboptimal treatment planning. While deep learning has shown promise in HCC diagnosis, most existing models rely exclusively on single-modality ultrasound, overlooking the diagnostic benefits of integrating complementary information from multiple imaging sources. To address this gap, we propose a novel attention-weighted tri-modal ultrasound network (TUS-Net) that integrates contrast-enhanced ultrasound (CEUS), B-mode ultrasound (BUS), and time-intensity curves (TICs) to improve diagnostic accuracy for these clinically challenging lesions. MethodsOur framework incorporates a three-dimensional convolutional neural network (C3D) backbone to extract spatiotemporal features from CEUS videos, capturing dynamic vascular patterns critical for lesion characterization. To effectively fuse complementary modalities, we introduce a dual-channel feature fusion module (DCFFM) that adaptively combines features from CEUS and BUS through channel-wise attention mechanisms, allowing the model to dynamically weigh the contribution of each modality based on diagnostic relevance. Additionally, we propose a temporal intensity feature fusion module (TIFFM) that leverages quantitative hemodynamic information from TICs to guide the model’s attention toward diagnostically critical temporal phases, such as arterial wash-in and portal venous washout. The model is further enhanced by automated lesion localization using YOLOX and class activation mapping for interpretability, ensuring that predictions align with clinically meaningful imaging features. ResultsEvaluated on a tri-modal ultrasound dataset comprising 161 patients with pathologically confirmed LR-M nodules (131 atypical HCC and 30 non-HCC malignancies), our model achieved an accuracy of 86.83%, a sensitivity of 92.50%, a specificity of 75.50%, and an AUC of 89.32% in screening atypical HCC. Compared to single-modality baselines, TUS-Net demonstrated superior specificity, a clinically critical metric given the higher risk associated with misclassifying non-HCC malignancies. Ablation studies confirmed the contribution of each module, with the full model outperforming both standard C3D and 3D ResNet backbones integrated with attention mechanisms. A reader study involving junior and senior radiologists further validated the clinical utility of AI assistance, showing consistent improvements in specificity and inter-reader consistency, particularly for less experienced clinicians. ConclusionThese results surpass existing benchmark models and demonstrate the potential of our approach to enhance diagnostic precision in clinically specific cases. By intelligently fusing multi-modal ultrasound data with attention-guided mechanisms, TUS-Net offers a reliable and interpretable tool that holds promise for improving the non-invasive diagnosis of atypical HCC in challenging LR-M liver nodules.
4.Predicting Hepatocellular Carcinoma Using Brightness Change Curves Derived From Contrast-enhanced Ultrasound Images
Ying-Ying CHEN ; Shang-Lin JIANG ; Liang-Hui HUANG ; Ya-Guang ZENG ; Xue-Hua WANG ; Wei ZHENG
Progress in Biochemistry and Biophysics 2025;52(8):2163-2172
ObjectivePrimary liver cancer, predominantly hepatocellular carcinoma (HCC), is a significant global health issue, ranking as the sixth most diagnosed cancer and the third leading cause of cancer-related mortality. Accurate and early diagnosis of HCC is crucial for effective treatment, as HCC and non-HCC malignancies like intrahepatic cholangiocarcinoma (ICC) exhibit different prognoses and treatment responses. Traditional diagnostic methods, including liver biopsy and contrast-enhanced ultrasound (CEUS), face limitations in applicability and objectivity. The primary objective of this study was to develop an advanced, light-weighted classification network capable of distinguishing HCC from other non-HCC malignancies by leveraging the automatic analysis of brightness changes in CEUS images. The ultimate goal was to create a user-friendly and cost-efficient computer-aided diagnostic tool that could assist radiologists in making more accurate and efficient clinical decisions. MethodsThis retrospective study encompassed a total of 161 patients, comprising 131 diagnosed with HCC and 30 with non-HCC malignancies. To achieve accurate tumor detection, the YOLOX network was employed to identify the region of interest (ROI) on both B-mode ultrasound and CEUS images. A custom-developed algorithm was then utilized to extract brightness change curves from the tumor and adjacent liver parenchyma regions within the CEUS images. These curves provided critical data for the subsequent analysis and classification process. To analyze the extracted brightness change curves and classify the malignancies, we developed and compared several models. These included one-dimensional convolutional neural networks (1D-ResNet, 1D-ConvNeXt, and 1D-CNN), as well as traditional machine-learning methods such as support vector machine (SVM), ensemble learning (EL), k-nearest neighbor (KNN), and decision tree (DT). The diagnostic performance of each method in distinguishing HCC from non-HCC malignancies was rigorously evaluated using four key metrics: area under the receiver operating characteristic (AUC), accuracy (ACC), sensitivity (SE), and specificity (SP). ResultsThe evaluation of the machine-learning methods revealed AUC values of 0.70 for SVM, 0.56 for ensemble learning, 0.63 for KNN, and 0.72 for the decision tree. These results indicated moderate to fair performance in classifying the malignancies based on the brightness change curves. In contrast, the deep learning models demonstrated significantly higher AUCs, with 1D-ResNet achieving an AUC of 0.72, 1D-ConvNeXt reaching 0.82, and 1D-CNN obtaining the highest AUC of 0.84. Moreover, under the five-fold cross-validation scheme, the 1D-CNN model outperformed other models in both accuracy and specificity. Specifically, it achieved accuracy improvements of 3.8% to 10.0% and specificity enhancements of 6.6% to 43.3% over competing approaches. The superior performance of the 1D-CNN model highlighted its potential as a powerful tool for accurate classification. ConclusionThe 1D-CNN model proved to be the most effective in differentiating HCC from non-HCC malignancies, surpassing both traditional machine-learning methods and other deep learning models. This study successfully developed a user-friendly and cost-efficient computer-aided diagnostic solution that would significantly enhances radiologists’ diagnostic capabilities. By improving the accuracy and efficiency of clinical decision-making, this tool has the potential to positively impact patient care and outcomes. Future work may focus on further refining the model and exploring its integration with multimodal ultrasound data to maximize its accuracy and applicability.
5.Design of electric ice blanket system for early treatment of heat stroke disease
Bo-wen YAN ; Yan-yi LU ; Lin ZENG ; Zhi-gang ZHANG ; Nan XIAO ; Qing-hua HE
Chinese Medical Equipment Journal 2025;46(9):16-21
Objective To design an electric ice blanket system for prehospital emergency care of patients of heat sroke disease.Methods The electric ice blanket system consisted of a cooling host and cooling accessories.The cooling host had its chassis made of acrylonitrile-butadiene-styrene(ABS),which was equipped externally with an lithium battery and a DC power adapter,and integrated internally a cooling system,an internal circulation pump,an external circulation pump and a main control system;the cooling accessories included a cooling blanket,a cooling cap and a cooling vest,which had the inner layer made of thermoplastic polyurethane(TPU)elastomer and the outer layer made of Oxford cloth or polyester fiber.The system was compared with the existing subcooling therapeutic apparatus on the market in terms of cooling effect with a water bag simulation cooling experiment.Results The cooling experiment showed that the system was comparable to the existing subcooling therapeutic apparatus on the market in terms of cooling effect while behaved well in size and weight.Conclusion The system developed has a high cooling effect and advantages in portability and compatibility to the environment without power supply,which can be used for the early treatment of patients of heat stroke disease.[Chinese Medical Equipment Journal,2025,46(9):16-21]
6.Clinical guideline for diagnosis and treatment of nonunion of osteoporotic vertebral fractures (version 2025)
Haipeng SI ; Le LI ; Junjie NIU ; Wencan ZHANG ; Fuxin WEI ; Jinqiu YUAN ; Qiang YANG ; Hongli WANG ; Guangchao WANG ; Shihong CHEN ; Yunzhen CHEN ; Xiaoguang CHENG ; Jianwen DONG ; Shiqing FENG ; Rui GU ; Yong HAI ; Tianyong HOU ; Bo HUANG ; Xiaobing JIANG ; Lei ZANG ; Chunhai LI ; Nianhu LI ; Hua LIN ; Hongjian LIU ; Peng LIU ; Xinyu LIU ; Sheng LU ; Shibao LU ; Chunshan LUO ; Lvy CHAOLIANG ; Lvy WEIJIA ; Xuexiao MA ; Wei MEI ; Chunyang MENG ; Cailiang SHEN ; Chunli SONG ; Ruoxian SONG ; Jiacan SU ; Honglin TENG ; Hui SHENG ; Beiyu WANG ; Bingwu WANG ; Liang WANG ; Xiangyang WANG ; Nan WU ; Guohua XU ; Yayi XIA ; Jin XU ; Youjia XU ; Jianzhong XU ; Cao YANG ; Maowei YANG ; Zibin YANG ; Xiaojian YE ; Hailong YU ; Xijie YU ; Hua YUE ; Zhili ZENG ; Xinli ZHAN ; Hui ZHANG ; Peixun ZHANG ; Wei ZHANG ; Zhenlin ZHANG ; Jianguo ZHANG ; Tengyue ZHU ; Qiang LIU ; Huilin YANG
Chinese Journal of Trauma 2025;41(10):932-945
Nonunion of osteoporotic vertebral fractures (OVF), predominantly affecting the elderly, can lead to intractable pain, vertebral collapse, progressive kyphotic deformity, and neurological impairment, significantly compromising patients′ quality of life. There exists considerable debate on diagnosis and management of OVF, encompassing key issues such as clinical diagnosis and staging criteria for nonunion, surgical indications and procedure selection, and postoperative rehabilitation planning. Currently, there lacks standardized clinical guideline and expert consensus on the diagnosis and management of OVF nonunion in China. To address this gap, Minimally Invasive Surgery Group of Chinese Orthopedic Association, Osteoporosis Committee of Chinese Association of Orthopedic Surgeons, Prevention and Rehabilitation Committee for Osteoporosis of Chinese Association of Rehabilitation Medicine and Minimally Invasive Orthopedic Surgery Branch of China Association for Geriatric Care jointly organized domestic experts in spinal surgery, endocrinology, and rehabilitation to formulate the Clinical guideline for the diagnosis and treatment for nonunion of osteoporotic vertebral fractures ( version 2025), based on existing literature and clinical experience and adhering to principles of scientific rigor and practicality. The guideline provided 13 evidence-based recommendations encompassing diagnosis and treatment of OVF nonunion, aiming to standardize its clinical management.
7.Clinical guideline for vertebral augmentation of acute symptomatic osteoporotic thoracolumbar compression fractures (version 2025)
Bolong ZHENG ; Wei MEI ; Yanzheng GAO ; Liming CHENG ; Jian CHEN ; Qixin CHEN ; Liang CHEN ; Xigao CHENG ; Jian DONG ; Jin FAN ; Shunwu FAN ; Xiangqian FANG ; Zhong FANG ; Shiqing FENG ; Haoyu FENG ; Haishan GUAN ; Yong HAI ; Baorong HE ; Lijun HE ; Yuan HE ; Hua HUI ; Weimin JIANG ; Junjie JIANG ; Dianming JIANG ; Xuewen KANG ; Hua GUO ; Jianjun LI ; Feng LI ; Li LI ; Weishi LI ; Chunde LI ; Qi LIAO ; Baoge LIU ; Xiaoguang LIU ; Xuhua LU ; Shibao LU ; Bin LIN ; Chao MA ; Xuexiao MA ; Renfu QUAN ; Limin RONG ; Honghui SUN ; Tiansheng SUN ; Yueming SONG ; Hongxun SANG ; Jun SHU ; Jiacan SU ; Jiwei TIAN ; Xinwei WANG ; Zhe WANG ; Zheng WANG ; Zhengwei XU ; Huilin YANG ; Jiancheng YANG ; Liang YAN ; Feng YAN ; Guoyong YIN ; Xuesong ZHANG ; Zhongmin ZHANG ; Jie ZHAO ; Yuhong ZENG ; Yue ZHU ; Rongqiang ZHANG
Chinese Journal of Trauma 2025;41(9):805-818
Acute symptomatic osteoporotic thoracolumbar compression fracture (ASOTLF) can lead to chronic low back pain, kyphosis deformity, pulmonary dysfunction, loss of mobility, and even life-threatening complications. Vertebral augmentation is currently the mainstream treatment method for this condition. In 2019, the Editorial Board of Chinese Journal of Trauma and the Spinal Trauma Group of Orthopedic Surgeons Branch of Chinese Medical Doctor Association collaboratively led the development of Clinical guideline for vertebral augmentation for acute symptomatic osteoporotic thoracolumbar compression fractures. Six years later, with advances in clinical diagnosis and treatment techniques as well as accumulating evidence in related fields, the 2019 guideline requires updating. To this end, the Spinal Trauma Group of Orthopedic Surgeons Branch of Chinese Medical Doctor Association, the Spinal Health Professional Committee of China Human Health Science and Technology Promotion Association, and the Minimally Invasive Orthopedics Professional Committee of Shaanxi Medical Doctor Association have organized experts in the field to develop the Clinical guideline for vertebral augmentation of acute symptomatic osteoporotic thoracolumbar compression fractures ( version 2025) , based on the latest evidence-based medical researches. This guideline incorporates 3 recommendations retained from the 2019 version with updated strength of evidence, along with 12 new recommendations. It provides recommendations from six aspects of diagnosis, pain management, treatment option selection, prevention of postoperative complications, anti-osteoporosis therapy, and postoperative rehabilitation, aiming to provide a reference for standard treatment of vertebral augmentation for ASOTLF in hospitals at all levels.
8.Guideline for the prevention of intraoperative acquired pressure injury in paraplegic patients with spinal cord injury (version 2025)
Aijun XU ; Shuixia LI ; Bo CHEN ; Mengyuan YE ; Lejiao LANG ; Ning NING ; Lin ZHANG ; Changqing LIU ; Zhonglan CHEN ; Weihu MA ; Weishi LI ; Xiaoning WANG ; Dongmei BIAN ; Jiancheng ZENG ; Xin WANG ; Yuan GAO ; Yaping CHEN ; Jiali CHEN ; Yun HAN ; Xiuting LI ; Yang ZHOU ; Xiaojing SU ; Qiong ZHANG ; Tianwen HUANG ; Ping ZHANG ; Hua LIN ; Xingling XIAO ; Ruifeng XU ; Fanghui DONG ; Bing HAN ; Luo FAN ; Yanling PEI ; Suyun LI ; Xiaoju TAN ; Rongchen GUO ; Yefang ZOU ; Xiaoyun HAN ; Junqin DING ; Yi WANG ; Shuhua DENG ; Jinli GUO ; Yinhua LIANG ; Yuan CEN ; Xiaoqin LIU ; Junru CHEN ; Haiyang YU ; Lunlan LI ; Ying REN ; Yunxia LI ; Jianli LU ; Ying YING ; Lan WEI ; Yin WANG ; Qinhong XU ; Yanqin ZHANG ; Yang LYU ; Shijun ZHANG ; Sui WENJIE ; Sanlian HU ; Shuhong YANG ; Guoqing LI ; Jingjing AN ; Baorong HE ; Leling FENG
Chinese Journal of Trauma 2025;41(6):530-541
Paraplegia caused by spinal cord injury is a serious neurological complication, for which surgery is currently the main treatment method. Due to different surgical approaches, patients are usually expected to maintain a passive prone position for a long time or switch between the supine and prone positions. Affected by multiple factors such as neurogenic sensory disorders, pathological changes in muscle tone and operative duration, the risk of intraoperative acquired pressure injury (IAPI) is significantly increased. Current clinical prevention strategies for IAPI in these patients predominantly focus on localized pressure relief during positioning, lacking systematic, standardized comprehensive prevention protocols or evidence-based guidelines. To address it, Department of Nursing, Orthopedics Branch, China International Exchange and Promotive Association for Medical and Health Care, Spinal Trauma Professional Committee, Orthopedics Branch, Chinese Medical Doctor Association, Nursing Group of Spine and Spinal Cord Professional Committee of Chinese Association of Rehabilitation Medicine organized experts in relevant fields to formulate Guideline for the prevention of intraoperative acquired pressure injury in paraplegic patients with spinal cord injury ( version 2025), based on evidence-based medical evidence and latest research results and clinical practice at home and abroad. Eleven recommendations were put forward from the aspects of preoperative risk assessment, intraoperative prevention strategies, postoperative handover and monitoring, and supportive mechanisms for IAPI prevention, aiming to standardize the prevention measures and management strategies of IAPI in paraplegic patients with spinal cord injury and accelerate the recovery of patients and improve the therapeutic effect.
9.Clinical guideline for diagnosis and treatment of nonunion of osteoporotic vertebral fractures (version 2025)
Haipeng SI ; Le LI ; Junjie NIU ; Wencan ZHANG ; Fuxin WEI ; Jinqiu YUAN ; Qiang YANG ; Hongli WANG ; Guangchao WANG ; Shihong CHEN ; Yunzhen CHEN ; Xiaoguang CHENG ; Jianwen DONG ; Shiqing FENG ; Rui GU ; Yong HAI ; Tianyong HOU ; Bo HUANG ; Xiaobing JIANG ; Lei ZANG ; Chunhai LI ; Nianhu LI ; Hua LIN ; Hongjian LIU ; Peng LIU ; Xinyu LIU ; Sheng LU ; Shibao LU ; Chunshan LUO ; Lvy CHAOLIANG ; Lvy WEIJIA ; Xuexiao MA ; Wei MEI ; Chunyang MENG ; Cailiang SHEN ; Chunli SONG ; Ruoxian SONG ; Jiacan SU ; Honglin TENG ; Hui SHENG ; Beiyu WANG ; Bingwu WANG ; Liang WANG ; Xiangyang WANG ; Nan WU ; Guohua XU ; Yayi XIA ; Jin XU ; Youjia XU ; Jianzhong XU ; Cao YANG ; Maowei YANG ; Zibin YANG ; Xiaojian YE ; Hailong YU ; Xijie YU ; Hua YUE ; Zhili ZENG ; Xinli ZHAN ; Hui ZHANG ; Peixun ZHANG ; Wei ZHANG ; Zhenlin ZHANG ; Jianguo ZHANG ; Tengyue ZHU ; Qiang LIU ; Huilin YANG
Chinese Journal of Trauma 2025;41(10):932-945
Nonunion of osteoporotic vertebral fractures (OVF), predominantly affecting the elderly, can lead to intractable pain, vertebral collapse, progressive kyphotic deformity, and neurological impairment, significantly compromising patients′ quality of life. There exists considerable debate on diagnosis and management of OVF, encompassing key issues such as clinical diagnosis and staging criteria for nonunion, surgical indications and procedure selection, and postoperative rehabilitation planning. Currently, there lacks standardized clinical guideline and expert consensus on the diagnosis and management of OVF nonunion in China. To address this gap, Minimally Invasive Surgery Group of Chinese Orthopedic Association, Osteoporosis Committee of Chinese Association of Orthopedic Surgeons, Prevention and Rehabilitation Committee for Osteoporosis of Chinese Association of Rehabilitation Medicine and Minimally Invasive Orthopedic Surgery Branch of China Association for Geriatric Care jointly organized domestic experts in spinal surgery, endocrinology, and rehabilitation to formulate the Clinical guideline for the diagnosis and treatment for nonunion of osteoporotic vertebral fractures ( version 2025), based on existing literature and clinical experience and adhering to principles of scientific rigor and practicality. The guideline provided 13 evidence-based recommendations encompassing diagnosis and treatment of OVF nonunion, aiming to standardize its clinical management.
10.Clinical guideline for vertebral augmentation of acute symptomatic osteoporotic thoracolumbar compression fractures (version 2025)
Bolong ZHENG ; Wei MEI ; Yanzheng GAO ; Liming CHENG ; Jian CHEN ; Qixin CHEN ; Liang CHEN ; Xigao CHENG ; Jian DONG ; Jin FAN ; Shunwu FAN ; Xiangqian FANG ; Zhong FANG ; Shiqing FENG ; Haoyu FENG ; Haishan GUAN ; Yong HAI ; Baorong HE ; Lijun HE ; Yuan HE ; Hua HUI ; Weimin JIANG ; Junjie JIANG ; Dianming JIANG ; Xuewen KANG ; Hua GUO ; Jianjun LI ; Feng LI ; Li LI ; Weishi LI ; Chunde LI ; Qi LIAO ; Baoge LIU ; Xiaoguang LIU ; Xuhua LU ; Shibao LU ; Bin LIN ; Chao MA ; Xuexiao MA ; Renfu QUAN ; Limin RONG ; Honghui SUN ; Tiansheng SUN ; Yueming SONG ; Hongxun SANG ; Jun SHU ; Jiacan SU ; Jiwei TIAN ; Xinwei WANG ; Zhe WANG ; Zheng WANG ; Zhengwei XU ; Huilin YANG ; Jiancheng YANG ; Liang YAN ; Feng YAN ; Guoyong YIN ; Xuesong ZHANG ; Zhongmin ZHANG ; Jie ZHAO ; Yuhong ZENG ; Yue ZHU ; Rongqiang ZHANG
Chinese Journal of Trauma 2025;41(9):805-818
Acute symptomatic osteoporotic thoracolumbar compression fracture (ASOTLF) can lead to chronic low back pain, kyphosis deformity, pulmonary dysfunction, loss of mobility, and even life-threatening complications. Vertebral augmentation is currently the mainstream treatment method for this condition. In 2019, the Editorial Board of Chinese Journal of Trauma and the Spinal Trauma Group of Orthopedic Surgeons Branch of Chinese Medical Doctor Association collaboratively led the development of Clinical guideline for vertebral augmentation for acute symptomatic osteoporotic thoracolumbar compression fractures. Six years later, with advances in clinical diagnosis and treatment techniques as well as accumulating evidence in related fields, the 2019 guideline requires updating. To this end, the Spinal Trauma Group of Orthopedic Surgeons Branch of Chinese Medical Doctor Association, the Spinal Health Professional Committee of China Human Health Science and Technology Promotion Association, and the Minimally Invasive Orthopedics Professional Committee of Shaanxi Medical Doctor Association have organized experts in the field to develop the Clinical guideline for vertebral augmentation of acute symptomatic osteoporotic thoracolumbar compression fractures ( version 2025) , based on the latest evidence-based medical researches. This guideline incorporates 3 recommendations retained from the 2019 version with updated strength of evidence, along with 12 new recommendations. It provides recommendations from six aspects of diagnosis, pain management, treatment option selection, prevention of postoperative complications, anti-osteoporosis therapy, and postoperative rehabilitation, aiming to provide a reference for standard treatment of vertebral augmentation for ASOTLF in hospitals at all levels.

Result Analysis
Print
Save
E-mail