1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.An Attention-weighted Tri-modal Ultrasound Network (TUS-Net) for Screening of Atypical Hepatocellular Carcinoma From LR-M Liver Nodules
He-Chong ZHANG ; Liang-Hui HUANG ; Xue-Hua WANG ; Shang-Lin JIANG ; Ying-Ying CHEN ; Ya-Guang ZENG ; Wei ZHENG
Progress in Biochemistry and Biophysics 2026;53(5):1485-1498
ObjectiveDiscriminating atypical hepatocellular carcinoma (HCC) from other malignancies in liver nodules classified as Liver Imaging Reporting and Data System category M (LR-M) remains a significant diagnostic challenge on conventional ultrasound examination. The LR-M category, originally intended to capture non-HCC malignancies, paradoxically contains up to 63% of atypical HCCs that deviate from classic enhancement patterns, leading to potential misdiagnosis and suboptimal treatment planning. While deep learning has shown promise in HCC diagnosis, most existing models rely exclusively on single-modality ultrasound, overlooking the diagnostic benefits of integrating complementary information from multiple imaging sources. To address this gap, we propose a novel attention-weighted tri-modal ultrasound network (TUS-Net) that integrates contrast-enhanced ultrasound (CEUS), B-mode ultrasound (BUS), and time-intensity curves (TICs) to improve diagnostic accuracy for these clinically challenging lesions. MethodsOur framework incorporates a three-dimensional convolutional neural network (C3D) backbone to extract spatiotemporal features from CEUS videos, capturing dynamic vascular patterns critical for lesion characterization. To effectively fuse complementary modalities, we introduce a dual-channel feature fusion module (DCFFM) that adaptively combines features from CEUS and BUS through channel-wise attention mechanisms, allowing the model to dynamically weigh the contribution of each modality based on diagnostic relevance. Additionally, we propose a temporal intensity feature fusion module (TIFFM) that leverages quantitative hemodynamic information from TICs to guide the model’s attention toward diagnostically critical temporal phases, such as arterial wash-in and portal venous washout. The model is further enhanced by automated lesion localization using YOLOX and class activation mapping for interpretability, ensuring that predictions align with clinically meaningful imaging features. ResultsEvaluated on a tri-modal ultrasound dataset comprising 161 patients with pathologically confirmed LR-M nodules (131 atypical HCC and 30 non-HCC malignancies), our model achieved an accuracy of 86.83%, a sensitivity of 92.50%, a specificity of 75.50%, and an AUC of 89.32% in screening atypical HCC. Compared to single-modality baselines, TUS-Net demonstrated superior specificity, a clinically critical metric given the higher risk associated with misclassifying non-HCC malignancies. Ablation studies confirmed the contribution of each module, with the full model outperforming both standard C3D and 3D ResNet backbones integrated with attention mechanisms. A reader study involving junior and senior radiologists further validated the clinical utility of AI assistance, showing consistent improvements in specificity and inter-reader consistency, particularly for less experienced clinicians. ConclusionThese results surpass existing benchmark models and demonstrate the potential of our approach to enhance diagnostic precision in clinically specific cases. By intelligently fusing multi-modal ultrasound data with attention-guided mechanisms, TUS-Net offers a reliable and interpretable tool that holds promise for improving the non-invasive diagnosis of atypical HCC in challenging LR-M liver nodules.
3.An Attention-weighted Tri-modal Ultrasound Network (TUS-Net) for Screening of Atypical Hepatocellular Carcinoma From LR-M Liver Nodules
He-Chong ZHANG ; Liang-Hui HUANG ; Xue-Hua WANG ; Shang-Lin JIANG ; Ying-Ying CHEN ; Ya-Guang ZENG ; Wei ZHENG
Progress in Biochemistry and Biophysics 2026;53(5):1485-1498
ObjectiveDiscriminating atypical hepatocellular carcinoma (HCC) from other malignancies in liver nodules classified as Liver Imaging Reporting and Data System category M (LR-M) remains a significant diagnostic challenge on conventional ultrasound examination. The LR-M category, originally intended to capture non-HCC malignancies, paradoxically contains up to 63% of atypical HCCs that deviate from classic enhancement patterns, leading to potential misdiagnosis and suboptimal treatment planning. While deep learning has shown promise in HCC diagnosis, most existing models rely exclusively on single-modality ultrasound, overlooking the diagnostic benefits of integrating complementary information from multiple imaging sources. To address this gap, we propose a novel attention-weighted tri-modal ultrasound network (TUS-Net) that integrates contrast-enhanced ultrasound (CEUS), B-mode ultrasound (BUS), and time-intensity curves (TICs) to improve diagnostic accuracy for these clinically challenging lesions. MethodsOur framework incorporates a three-dimensional convolutional neural network (C3D) backbone to extract spatiotemporal features from CEUS videos, capturing dynamic vascular patterns critical for lesion characterization. To effectively fuse complementary modalities, we introduce a dual-channel feature fusion module (DCFFM) that adaptively combines features from CEUS and BUS through channel-wise attention mechanisms, allowing the model to dynamically weigh the contribution of each modality based on diagnostic relevance. Additionally, we propose a temporal intensity feature fusion module (TIFFM) that leverages quantitative hemodynamic information from TICs to guide the model’s attention toward diagnostically critical temporal phases, such as arterial wash-in and portal venous washout. The model is further enhanced by automated lesion localization using YOLOX and class activation mapping for interpretability, ensuring that predictions align with clinically meaningful imaging features. ResultsEvaluated on a tri-modal ultrasound dataset comprising 161 patients with pathologically confirmed LR-M nodules (131 atypical HCC and 30 non-HCC malignancies), our model achieved an accuracy of 86.83%, a sensitivity of 92.50%, a specificity of 75.50%, and an AUC of 89.32% in screening atypical HCC. Compared to single-modality baselines, TUS-Net demonstrated superior specificity, a clinically critical metric given the higher risk associated with misclassifying non-HCC malignancies. Ablation studies confirmed the contribution of each module, with the full model outperforming both standard C3D and 3D ResNet backbones integrated with attention mechanisms. A reader study involving junior and senior radiologists further validated the clinical utility of AI assistance, showing consistent improvements in specificity and inter-reader consistency, particularly for less experienced clinicians. ConclusionThese results surpass existing benchmark models and demonstrate the potential of our approach to enhance diagnostic precision in clinically specific cases. By intelligently fusing multi-modal ultrasound data with attention-guided mechanisms, TUS-Net offers a reliable and interpretable tool that holds promise for improving the non-invasive diagnosis of atypical HCC in challenging LR-M liver nodules.
4.Predicting Hepatocellular Carcinoma Using Brightness Change Curves Derived From Contrast-enhanced Ultrasound Images
Ying-Ying CHEN ; Shang-Lin JIANG ; Liang-Hui HUANG ; Ya-Guang ZENG ; Xue-Hua WANG ; Wei ZHENG
Progress in Biochemistry and Biophysics 2025;52(8):2163-2172
ObjectivePrimary liver cancer, predominantly hepatocellular carcinoma (HCC), is a significant global health issue, ranking as the sixth most diagnosed cancer and the third leading cause of cancer-related mortality. Accurate and early diagnosis of HCC is crucial for effective treatment, as HCC and non-HCC malignancies like intrahepatic cholangiocarcinoma (ICC) exhibit different prognoses and treatment responses. Traditional diagnostic methods, including liver biopsy and contrast-enhanced ultrasound (CEUS), face limitations in applicability and objectivity. The primary objective of this study was to develop an advanced, light-weighted classification network capable of distinguishing HCC from other non-HCC malignancies by leveraging the automatic analysis of brightness changes in CEUS images. The ultimate goal was to create a user-friendly and cost-efficient computer-aided diagnostic tool that could assist radiologists in making more accurate and efficient clinical decisions. MethodsThis retrospective study encompassed a total of 161 patients, comprising 131 diagnosed with HCC and 30 with non-HCC malignancies. To achieve accurate tumor detection, the YOLOX network was employed to identify the region of interest (ROI) on both B-mode ultrasound and CEUS images. A custom-developed algorithm was then utilized to extract brightness change curves from the tumor and adjacent liver parenchyma regions within the CEUS images. These curves provided critical data for the subsequent analysis and classification process. To analyze the extracted brightness change curves and classify the malignancies, we developed and compared several models. These included one-dimensional convolutional neural networks (1D-ResNet, 1D-ConvNeXt, and 1D-CNN), as well as traditional machine-learning methods such as support vector machine (SVM), ensemble learning (EL), k-nearest neighbor (KNN), and decision tree (DT). The diagnostic performance of each method in distinguishing HCC from non-HCC malignancies was rigorously evaluated using four key metrics: area under the receiver operating characteristic (AUC), accuracy (ACC), sensitivity (SE), and specificity (SP). ResultsThe evaluation of the machine-learning methods revealed AUC values of 0.70 for SVM, 0.56 for ensemble learning, 0.63 for KNN, and 0.72 for the decision tree. These results indicated moderate to fair performance in classifying the malignancies based on the brightness change curves. In contrast, the deep learning models demonstrated significantly higher AUCs, with 1D-ResNet achieving an AUC of 0.72, 1D-ConvNeXt reaching 0.82, and 1D-CNN obtaining the highest AUC of 0.84. Moreover, under the five-fold cross-validation scheme, the 1D-CNN model outperformed other models in both accuracy and specificity. Specifically, it achieved accuracy improvements of 3.8% to 10.0% and specificity enhancements of 6.6% to 43.3% over competing approaches. The superior performance of the 1D-CNN model highlighted its potential as a powerful tool for accurate classification. ConclusionThe 1D-CNN model proved to be the most effective in differentiating HCC from non-HCC malignancies, surpassing both traditional machine-learning methods and other deep learning models. This study successfully developed a user-friendly and cost-efficient computer-aided diagnostic solution that would significantly enhances radiologists’ diagnostic capabilities. By improving the accuracy and efficiency of clinical decision-making, this tool has the potential to positively impact patient care and outcomes. Future work may focus on further refining the model and exploring its integration with multimodal ultrasound data to maximize its accuracy and applicability.
5.Analysis of Gene Mutations Distribution and Enzyme Activity of G6PD Deficiency in Newborns in Guilin Region.
Dong-Mei YANG ; Guang-Li WANG ; Dong-Lang YU ; Dan ZENG ; Hai-Qing ZHENG ; Wen-Jun TANG ; Qiao FENG ; Kai LI ; Chun-Jiang ZHU
Journal of Experimental Hematology 2025;33(5):1405-1411
OBJECTIVE:
To analyze the distribution characteristics of glucose-6-phosphate-dehydrogenase (G6PD) mutations and their enzyme activity in newborns patients with G6PD deficiency in Guilin region.
METHODS:
From July 2022 to July 2024, umbilical cord blood samples from 4 554 newborns in Guilin were analyzed for G6PD mutations using fluorescence PCR melting curve analysis. Enzyme activity was detected in 4 467 cases using the rate assay.
RESULTS:
Among 4 467 newborns who underwent G6PD activity testing, 162 newborns (3.63%) were identified as G6PD-deficient, including 142 males (6.04%) and 20 females (0.94%), the prevalence of G6PD deficiency was significantly higher in males than in females (P < 0.001). Genetic analysis of 4 554 newborns detected G6PD mutations in 410 cases (9%), including 171 males (7.13%) and 239 females (11.09%), with a significantly higher mutation detection rate in females than in males (P < 0.001). A total of nine single mutations and four compound heterozygous mutations were identified. The most common mutations were c.1388G>A (33.66%), c.1376G>T (23.66%) and c.95A>G (16.34%). Among newborns who underwent both enzyme activity and genetic mutation testing, males with G6PD mutations had significantly lower enzyme activity than that of females with G6PD mutations(P < 0.001). Specifically, among newborns carrying the mutations c.1388G>A, c.1376G>T, c.95A>G, c.1024C>T or c.871G>A, males consistently exhibited lower enzymatic activity than females with the same mutations (P < 0.001). Furthermore, in male G6PD-deficient newborns, the enzyme activity levels in those carrying c.1388G>A, c.1376G>T, c.95A>G, c.1024C>T, or c.871G>A were lower than those in both the control group and the c.519C>T group (P < 0.05).
CONCLUSION
This study provides a comprehensive profile of G6PD deficiency incidence and mutation spectrum in the Guilin region. By analyzing enzyme activity and genetic mutation results, this study provides insights into potential intervention strategies and personalized management approaches for the prevention and treatment of neonatal G6PD deficiency in the region.
Humans
;
Infant, Newborn
;
Glucosephosphate Dehydrogenase Deficiency/epidemiology*
;
Glucosephosphate Dehydrogenase/genetics*
;
Female
;
Male
;
Mutation
;
China/epidemiology*
6.YOD1 regulates microglial homeostasis by deubiquitinating MYH9 to promote the pathogenesis of Alzheimer's disease.
Jinfeng SUN ; Fan CHEN ; Lingyu SHE ; Yuqing ZENG ; Hao TANG ; Bozhi YE ; Wenhua ZHENG ; Li XIONG ; Liwei LI ; Luyao LI ; Qin YU ; Linjie CHEN ; Wei WANG ; Guang LIANG ; Xia ZHAO
Acta Pharmaceutica Sinica B 2025;15(1):331-348
Alzheimer's disease (AD) is the major form of dementia in the elderly and is closely related to the toxic effects of microglia sustained activation. In AD, sustained microglial activation triggers impaired synaptic pruning, neuroinflammation, neurotoxicity, and cognitive deficits. Accumulating evidence has demonstrated that aberrant expression of deubiquitinating enzymes is associated with regulating microglia function. Here, we use RNA sequencing to identify a deubiquitinase YOD1 as a regulator of microglial function and AD pathology. Further study showed that YOD1 knockout significantly improved the migration, phagocytosis, and inflammatory response of microglia, thereby improving the cognitive impairment of AD model mice. Through LC-MS/MS analysis combined with Co-IP, we found that Myosin heavy chain 9 (MYH9), a key regulator maintaining microglia homeostasis, is an interacting protein of YOD1. Mechanistically, YOD1 binds to MYH9 and maintains its stability by removing the K48 ubiquitin chain from MYH9, thereby mediating the microglia polarization signaling pathway to mediate microglia homeostasis. Taken together, our study reveals a specific role of microglial YOD1 in mediating microglia homeostasis and AD pathology, which provides a potential strategy for targeting microglia to treat AD.
7.Guideline for Adult Weight Management in China
Weiqing WANG ; Qin WAN ; Jianhua MA ; Guang WANG ; Yufan WANG ; Guixia WANG ; Yongquan SHI ; Tingjun YE ; Xiaoguang SHI ; Jian KUANG ; Bo FENG ; Xiuyan FENG ; Guang NING ; Yiming MU ; Hongyu KUANG ; Xiaoping XING ; Chunli PIAO ; Xingbo CHENG ; Zhifeng CHENG ; Yufang BI ; Yan BI ; Wenshan LYU ; Dalong ZHU ; Cuiyan ZHU ; Wei ZHU ; Fei HUA ; Fei XIANG ; Shuang YAN ; Zilin SUN ; Yadong SUN ; Liqin SUN ; Luying SUN ; Li YAN ; Yanbing LI ; Hong LI ; Shu LI ; Ling LI ; Yiming LI ; Chenzhong LI ; Hua YANG ; Jinkui YANG ; Ling YANG ; Ying YANG ; Tao YANG ; Xiao YANG ; Xinhua XIAO ; Dan WU ; Jinsong KUANG ; Lanjie HE ; Wei GU ; Jie SHEN ; Yongfeng SONG ; Qiao ZHANG ; Hong ZHANG ; Yuwei ZHANG ; Junqing ZHANG ; Xianfeng ZHANG ; Miao ZHANG ; Yifei ZHANG ; Yingli LU ; Hong CHEN ; Li CHEN ; Bing CHEN ; Shihong CHEN ; Guiyan CHEN ; Haibing CHEN ; Lei CHEN ; Yanyan CHEN ; Genben CHEN ; Yikun ZHOU ; Xianghai ZHOU ; Qiang ZHOU ; Jiaqiang ZHOU ; Hongting ZHENG ; Zhongyan SHAN ; Jiajun ZHAO ; Dong ZHAO ; Ji HU ; Jiang HU ; Xinguo HOU ; Bimin SHI ; Tianpei HONG ; Mingxia YUAN ; Weibo XIA ; Xuejiang GU ; Yong XU ; Shuguang PANG ; Tianshu GAO ; Zuhua GAO ; Xiaohui GUO ; Hongyi CAO ; Mingfeng CAO ; Xiaopei CAO ; Jing MA ; Bin LU ; Zhen LIANG ; Jun LIANG ; Min LONG ; Yongde PENG ; Jin LU ; Hongyun LU ; Yan LU ; Chunping ZENG ; Binhong WEN ; Xueyong LOU ; Qingbo GUAN ; Lin LIAO ; Xin LIAO ; Ping XIONG ; Yaoming XUE
Chinese Journal of Endocrinology and Metabolism 2025;41(11):891-907
Body weight abnormalities, including overweight, obesity, and underweight, have become a dual public health challenge in Chinese adults: overweight and obesity lead to a variety of chronic complications, while underweight increases the risks of malnutrition, sarcopenia, and organ dysfunction. To systematically address these issues, multidisciplinary experts in endocrinology, sports science, nutrition, and psychiatry from various regions have held multiple weight management seminars. Based on the latest epidemiological data and clinical evidence, they expanded the guideline to include assessment and intervention strategies for underweight, in addition to the core content of obesity management. This guideline outlines the etiological mechanisms, evaluation methods, and multidimensional management strategies for overweight and obesity, covering key areas such as diagnosis and assessment, medical nutrition therapy, exercise prescription, pharmacological intervention, and psychological support. It is intended to provide a scientific and standardized approach to weight management across the adult population, aiming to curb the rising prevalence of obesity, mitigate complications associated with abnormal body weight, and improve nutritional status and overall quality of life.
8.Guideline for Adult Weight Management in China
Weiqing WANG ; Qin WAN ; Jianhua MA ; Guang WANG ; Yufan WANG ; Guixia WANG ; Yongquan SHI ; Tingjun YE ; Xiaoguang SHI ; Jian KUANG ; Bo FENG ; Xiuyan FENG ; Guang NING ; Yiming MU ; Hongyu KUANG ; Xiaoping XING ; Chunli PIAO ; Xingbo CHENG ; Zhifeng CHENG ; Yufang BI ; Yan BI ; Wenshan LYU ; Dalong ZHU ; Cuiyan ZHU ; Wei ZHU ; Fei HUA ; Fei XIANG ; Shuang YAN ; Zilin SUN ; Yadong SUN ; Liqin SUN ; Luying SUN ; Li YAN ; Yanbing LI ; Hong LI ; Shu LI ; Ling LI ; Yiming LI ; Chenzhong LI ; Hua YANG ; Jinkui YANG ; Ling YANG ; Ying YANG ; Tao YANG ; Xiao YANG ; Xinhua XIAO ; Dan WU ; Jinsong KUANG ; Lanjie HE ; Wei GU ; Jie SHEN ; Yongfeng SONG ; Qiao ZHANG ; Hong ZHANG ; Yuwei ZHANG ; Junqing ZHANG ; Xianfeng ZHANG ; Miao ZHANG ; Yifei ZHANG ; Yingli LU ; Hong CHEN ; Li CHEN ; Bing CHEN ; Shihong CHEN ; Guiyan CHEN ; Haibing CHEN ; Lei CHEN ; Yanyan CHEN ; Genben CHEN ; Yikun ZHOU ; Xianghai ZHOU ; Qiang ZHOU ; Jiaqiang ZHOU ; Hongting ZHENG ; Zhongyan SHAN ; Jiajun ZHAO ; Dong ZHAO ; Ji HU ; Jiang HU ; Xinguo HOU ; Bimin SHI ; Tianpei HONG ; Mingxia YUAN ; Weibo XIA ; Xuejiang GU ; Yong XU ; Shuguang PANG ; Tianshu GAO ; Zuhua GAO ; Xiaohui GUO ; Hongyi CAO ; Mingfeng CAO ; Xiaopei CAO ; Jing MA ; Bin LU ; Zhen LIANG ; Jun LIANG ; Min LONG ; Yongde PENG ; Jin LU ; Hongyun LU ; Yan LU ; Chunping ZENG ; Binhong WEN ; Xueyong LOU ; Qingbo GUAN ; Lin LIAO ; Xin LIAO ; Ping XIONG ; Yaoming XUE
Chinese Journal of Endocrinology and Metabolism 2025;41(11):891-907
Body weight abnormalities, including overweight, obesity, and underweight, have become a dual public health challenge in Chinese adults: overweight and obesity lead to a variety of chronic complications, while underweight increases the risks of malnutrition, sarcopenia, and organ dysfunction. To systematically address these issues, multidisciplinary experts in endocrinology, sports science, nutrition, and psychiatry from various regions have held multiple weight management seminars. Based on the latest epidemiological data and clinical evidence, they expanded the guideline to include assessment and intervention strategies for underweight, in addition to the core content of obesity management. This guideline outlines the etiological mechanisms, evaluation methods, and multidimensional management strategies for overweight and obesity, covering key areas such as diagnosis and assessment, medical nutrition therapy, exercise prescription, pharmacological intervention, and psychological support. It is intended to provide a scientific and standardized approach to weight management across the adult population, aiming to curb the rising prevalence of obesity, mitigate complications associated with abnormal body weight, and improve nutritional status and overall quality of life.
9.Nape Needling at Six Points with Electroacupuncture Combined with Huayu J ingbi Decoction in the Treatment of Cervical Spondylotic Vertebralartery:A Retrospective Study
Fan-Guang ZENG ; Da-Zhong WANG ; Zheng-Lin LU
Journal of Guangzhou University of Traditional Chinese Medicine 2024;41(5):1244-1249
Objective To analyze the clinical efficacy of nape needling at six points with electroacupuncture combined with Huayu Jingbi Decoction in the treatment of cervical spondylotic vertebralartery(CSA).Methods A retrospective study was conducted to collect 126 patients with CSA admitted to Haikou Hospital of Traditional Chinese Medicine from May 2021 to May 2023.According to different treatment regimens,they were divided into observation group(59 cases)and control group(67 cases).The observation group was treated with nape needling at six points with electroacupuncture combined with Huayu Jingbi Decoction,while the control group was treated with conventional acupuncture combined with Huayu Jingbi Decoction.Two weeks was a course of treatment,and both groups were treated for two courses.The changes of neck disability index(NDI)and cervical physiological curvature were observed before and after treatment in the two groups.The changes of hemorheology and hemodynamic indexes were compared before and after treatment between the two groups,and the clinical efficacy of the two groups was evaluated.Results(1)The total effective rate of the observation group was 96.61%(57/59),and the control group was 77.61%(52/67).The efficacy of the observation group was superior to that of the control group,and the difference was statistically significant(P<0.05).(2)After treatment,the NDI scores and cervical physiological curvature of the patients in the two groups were significantly improved(P<0.05),and the observation group was significantly superior to the control group in improving the NDI scores and cervical physiological curvature,with a statistically significant difference(P<0.05).(3)After treatment,the whole blood high cut viscosity,whole blood low cut viscosity,plasma viscosity and fibrinogen of patients in the two groups were significantly improved(P<0.05),and the observation group was significantly superior to the control group in improving whole blood high cut viscosity,whole blood low cut viscosity,plasma viscosity and fibrinogen,and the differences were statistically significant(P<0.05).(4)After treatment,the Vs,Vm,PI and RI of the two groups of patients were significantly improved(P<0.05),and the observation group was significantly superior to the control group in improving Vs,Vm,PI and RI,with statistically significant differences(P<0.05).Conclusion Nape needling at six points with electroacupuncture combined with Huayu Jingbi Decoction has remarkable efficacy in the treatment of cervical spondylotic vertebralartery,which can significantly improve the cervical spine function of the patients,improve the blood rheology and haemodynamic indexes,and promote the recovery of the cervical spine function of the patients.
10.A single-center study on the safety and effectiveness of a novel non-implant interatrial shunt device
San-Shuai CHANG ; Xin-Min LIU ; Zheng-Ming JIANG ; Yu-Tong KE ; Qian ZHANG ; Qiang LÜ ; Xin DU ; Jian-Zeng DONG ; Guang-Yuan SONG
Chinese Journal of Interventional Cardiology 2024;32(8):425-433
Objective To preliminarily evaluate the safety and effectiveness of a novel non-implantable atrial shunt device based on radiofrequency ablation for the treatment of chronic heart failure(CHF).Methods This was a prospective single-arm study.From January 2023 to December 2023,five eligible CHF patients were consecutively enrolled at Beijing Anzhen Hospital,Capital Medical University,and underwent inter-atrial shunt using Shenzhen Betterway atrial shunt device.Pulmonary capillary wedge pressure(PCWP),right atrial pressure(RAP),pulmonary artery pressure(PAP),total pulmonary resistance(TPR),pulmonary vascular resistance(PVR),and pulmonary/systemic blood flow ratio(Qp/Qs)were measured using right heart catheterization before and immediately after procedure.Patients were followed up for 90 days,and echocardiography,right heart catheterization,and cardiac functional indicators were evaluated.The primary endpoint was procedural success.Secondary endpoints included clinical success,echocardiographic changes,6-minute walk distance(6MWD)changes,New York Heart Association(NYHA)class changes,Kansas city cardiomyopathy questionnaire(KCCQ)score changes,and amino-terminal probrain natriuretic peptide(NT-proBNP)level changes at 90 days.The safety endpoint was major cardiovascular and cerebrovascular adverse events and device-related adverse events.Results All five patients successfully achieved left-to-right atrial shunt.Compared with baseline,PCWP decreased significantly immediately after procedure in all five patients,with a procedural success rate of 100%.There were no significant changes in RAP,PAP,TPR,and PVR before and immediately after procedure.After 90 days follow-up,four patients had persistent left-to-right atrial shunt,and PCWP was significantly lower than baseline,with a clinical success rate of 80%.Compared with baseline,LVEF increased,left ventricular end-diastolic diameter decreased,and tricuspid annular plane systolic excursion and right ventricular fractional area change were not impaired in all five patients at 90 days.KCCQ scores and 6MWT improved,NT-proBNP decreased,and NYHA class did not change significantly.There were no deaths,rehospitalizations for heart failure,stroke-related adverse events,or device-related adverse events during the follow-up.Conclusions The novel non-implantable atrial shunt catheter can safely and effectively improve hemodynamic,echocardiographic,and cardiac functional indicators in patients with heart failure.However,larger-scale clinical studies are still needed to validate its long-term clinical effectiveness.

Result Analysis
Print
Save
E-mail