1.Research on software development and smart manufacturing platform incorporating near-infrared spectroscopy for measuring traditional Chinese medicine manufacturing process.
Yan-Fei WU ; Hui XU ; Kai-Yi WANG ; Hui-Min FENG ; Xiao-Yi LIU ; Nan LI ; Zhi-Jian ZHONG ; Ze-Xiu ZHANG ; Zhi-Sheng WU
China Journal of Chinese Materia Medica 2025;50(9):2324-2333
Process analytical technology(PAT) is a key means for digital transformation and upgrading of the traditional Chinese medicine(TCM) manufacturing process, serving as an important guarantee for consistent and controllable TCM product quality. Near-infrared(NIR) spectroscopy has become the core technology for measuring the TCM manufacturing process. By incorporating NIR spectroscopy into PAT and starting from the construction of a smart platform for the TCM manufacturing process, this paper systematically described the development history and innovative application of the combination of NIR spectroscopy with chemometrics in measuring the TCM manufacturing process by the research team over the past two decades. Additionally, it explored the application of a validation method based on accuracy profile(AP) in the practice of NIR spectroscopy. Furthermore, the software development progress driven by NIR spectroscopy supported by modeling technology was analyzed, and the prospect of integrating NIR spectroscopy in smart factory control platforms was exemplified with the construction practices of related platforms. By integrating with the smart platform, NIR spectroscopy could improve production efficiency and guarantee product quality. Finally, the prospect of the smart platform application in measuring the TCM manufacturing process was projected. It is believed that the software development for NIR spectroscopy and the smart manufacturing platform will provide strong technical support for TCM digitalization and industrialization.
Spectroscopy, Near-Infrared/methods*
;
Drugs, Chinese Herbal/analysis*
;
Software
;
Medicine, Chinese Traditional
;
Quality Control
2.Clinical correlation study between bone metabolism level and knee osteoarthritis pain.
Yong-Qi SUN ; Ke-Chun GUO ; Ze-Zhong LIU ; Jin-Shuai DUAN ; Bing XU ; Guo-Gang LUO ; Xian-Liang LAI ; Xiao-Feng WANG
China Journal of Orthopaedics and Traumatology 2025;38(5):482-486
OBJECTIVE:
To investigate the variability of bone metabolism levels among different populations and its association with knee osteoarthritis (KOA) pain.
METHODS:
A total of 50 people (control group) who participated in physical examination from January 2023 to June 2023 were selected, including 26 males and 24 females, wtih a mean aged of (52.14±9.04) years old ranging 41 to 65 years old. The other 50 patients with knee osteoarthritis(case group) who attended the outpatient clinic of the Orthopedics and Traumatology Department in the same time period, including 19 males and 31 females, with a mean age of (53.60±7.76) years old ranging 40 to 65 years. The two groups of Western Ontario and McMaster Universities Osteoarthritis Index(WOMAC) and bone metabolism markers, such as 25-hydroxy-cholecalciferol[25(OH)D], β-isomerized typeⅠcollagen C-telopeptide breakdown products (β-CTX), total typeⅠprocollagen N-terminal propeptide (t-PINP), osteocalcin (OC), parathormone (PTH) levels were compared. Pearson correlation analysis was used to compare the correlation between two groups of bone metabolism related markers and WOMAC.
RESULTS:
The WOMAC score of the case group (39.90±2.34) was higher than that of the control group (3.60±0.57), with significant difference (P<0.05). There was no significant difference between the two groups of 25 (OH)D, β-CTX and PTH (P>0.05). The t-PINP and OC of the case group were (62.90±52.40) and (19.88±10.15) ng·ml-1, respectively, and those of the control group were (38.86±10.82) and (14.90±3.62) ng·ml-1, respectively;the t-PINP and OC of the case group were higher than those of the control group, with significant difference (P<0.05). Pearson correlation analysis showed that t-PINP was positively correlated with WOMAC pain score in the case group (r2=0.045, P<0.01).
CONCLUSION
Bone metabolism levels in the serum of patients with knee osteoarthritis are different from those of healthy people, and the difference between OC and t-PINP is the most obvious, and the concentration of t-PINP levels is positively correlated with pain symptoms in patients with KOA. However, the specific mechanism of correlation between the bone metabolism levels of patients with KOA and their pain symptoms needs to be further elucidated by basic experimental research as well as by enlarging the samples.
Humans
;
Female
;
Male
;
Middle Aged
;
Osteoarthritis, Knee/metabolism*
;
Aged
;
Adult
;
Bone and Bones/metabolism*
;
Pain/etiology*
;
Biomarkers/metabolism*
3.Impact of human papillomavirus and coinfection with other sexually transmitted pathogens on male infertility.
Xin FAN ; Ya XU ; Li-Feng XIANG ; Lu-Ping LIU ; Jin-Xiu WAN ; Qiu-Ting DUAN ; Zi-Qin DIAN ; Yi SUN ; Ze WU ; Yun-Hua DONG
Asian Journal of Andrology 2025;27(1):84-89
This study primarily aimed to investigate the prevalence of human papillomavirus (HPV) and other common pathogens of sexually transmitted infections (STIs) in spermatozoa of infertile men and their effects on semen parameters. These pathogens included Ureaplasma urealyticum, Ureaplasma parvum, Chlamydia trachomatis, Mycoplasma genitalium , herpes simplex virus 2, Neisseria gonorrhoeae, Enterococcus faecalis, Streptococcus agalactiae, Pseudomonas aeruginosa , and Staphylococcus aureus . A total of 1951 men of infertile couples were recruited between 23 March 2023, and 17 May 2023, at the Department of Reproductive Medicine of The First People's Hospital of Yunnan Province (Kunming, China). Multiplex polymerase chain reaction and capillary electrophoresis were used for HPV genotyping. Polymerase chain reaction and electrophoresis were also used to detect the presence of other STIs. The overall prevalence of HPV infection was 12.4%. The top five prevalent HPV subtypes were types 56, 52, 43, 16, and 53 among those tested positive for HPV. Other common infections with high prevalence rates were Ureaplasma urealyticum (28.3%), Ureaplasma parvum (20.4%), and Enterococcus faecalis (9.5%). The prevalence rates of HPV coinfection with Ureaplasma urealyticum, Ureaplasma parvum, Chlamydia trachomatis, Mycoplasma genitalium , herpes simplex virus 2, Neisseria gonorrhoeae, Enterococcus faecalis, Streptococcus agalactiae , and Staphylococcus aureus were 24.8%, 25.4%, 10.6%, 6.4%, 2.4%, 7.9%, 5.9%, 0.9%, and 1.3%, respectively. The semen volume and total sperm count were greatly decreased by HPV infection alone. Coinfection with HPV and Ureaplasma urealyticum significantly reduced sperm motility and viability. Our study shows that coinfection with STIs is highly prevalent in the semen of infertile men and that coinfection with pathogens can seriously affect semen parameters, emphasizing the necessity of semen screening for STIs.
Humans
;
Male
;
Infertility, Male/epidemiology*
;
Coinfection/microbiology*
;
Papillomavirus Infections/virology*
;
Adult
;
Sexually Transmitted Diseases/complications*
;
China/epidemiology*
;
Staphylococcus aureus/isolation & purification*
;
Chlamydia trachomatis/isolation & purification*
;
Prevalence
;
Mycoplasma genitalium/isolation & purification*
;
Ureaplasma urealyticum/isolation & purification*
;
Neisseria gonorrhoeae/isolation & purification*
;
Enterococcus faecalis/isolation & purification*
;
Streptococcus agalactiae/isolation & purification*
;
Herpesvirus 2, Human/genetics*
;
Pseudomonas aeruginosa/isolation & purification*
;
Semen/virology*
;
Sperm Motility
;
Spermatozoa/microbiology*
;
Human Papillomavirus Viruses
4.Problems and suggestions of medical equipment and devices in plateau field conditions
Lei LIANG ; Jiang-hui HAO ; Ze-rui ZHANG ; Feng ZHOU ; Can-hua XU ; Tao ZHANG
Chinese Medical Equipment Journal 2025;46(3):86-89
The characteristics of plateau field conditions and the application of the medical equipment and devices were summarized.The influences of plateau field conditions on the use and maintenance of the medical equipment and devices were pointed out,and some countermeasures were put forward accordingly.The causes for the problems were analyzed,and some suggestions were proposed from the aspects of top-level design,standard and personnel training.References were provided for the use and maintenance of medical equipment and devices during stationed field training and support for military operations other than war in plateau field areas.[Chinese Medical Equipment Journal,2025,46(3):86-89]
5.The impact of implantable cardioverter defibrillator with lead alert function on inappropriate shocks caused by lead malfunctions
Cuizhen YUAN ; Feng ZE ; Cuncao WU ; Jiangbo DUAN ; Xu ZHOU ; Dandan YANG ; Ding LI ; Xuebin LI
Chinese Journal of Cardiology 2025;53(12):1398-1403
Objective:To evaluate the incidence and frequency of inappropriate shocks caused by defibrillation lead failure in patients with implantable cardioverter-defibrillators (ICD), and to explore methods for reducing the incidence and frequency of such inappropriate shocks.Methods:This was a single-center retrospective study involving patients treated for defibrillation lead failures at Peking University People′s Hospital between March 2015 and May 2024. Patients were divided into an alarm function group and a non-alarm function group based on whether their ICDs were equipped with lead alarm functions. Clinical data, lead data, and the incidence and frequency of inappropriate shocks were collected and compared between the two groups. A multivariate logistic regression model was used to analyze factors influencing the incidence and frequency of inappropriate ICD shocks. Kaplan-Meier survival curves were plotted to compare the trends in the incidence and frequency of inappropriate shocks over time since ICD implantation between the two groups.Results:A total of 59 patients were enrolled, with a age of (56.7±15.2) years, including 42 males (71%). The lifespan of the failed leads in the entire cohort was 64.0 (36.0, 96.0) months. There were 26 patients in the alarm function group and 33 in the non-alarm function group. The most common manifestations of lead failure were oversensing (85%, 50/59) and abnormal pacing impedance (42%, 25/59). A total of 33 patients (56%, 33/59) experienced inappropriate shock therapy, with an average of 27.3 shocks per patient. The frequency of inappropriate ICD shocks in the non-alarm function group was higher than that in the alarm function group (25.0 (10.0, 60.0) times/year vs. 5.0 (2.8, 7.8) times/year, P=0.001). Multivariate logistic regression analysis showed that oversensing ( OR=2.057, 95% CI 1.125-6.763, P=0.019) was an influencing factor for incidence of inappropriate shocks, while the lead alert function ( OR=0.062, 95% CI 0.005-0.719, P=0.001) was a factor influencing the frequency of inappropriate shocks. Kaplan-Meier survival analysis revealed that the incidence and frequency of inappropriate shocks increased with the duration of ICD implantation in both groups, but the differences were not statistically significant (incidence: log-rank P=0.908; frequency: log-rank P=0.767). Conclusion:The lead alert function can reduce the frequency of inappropriate shocks caused by lead failure.
6.Retrospective Clinical Analysis on Lead Extraction and Reimplantation Strategies,Success and Complication Rates During Upgrade of Cardiovascular Implantable Electronic Devices in Non-infected Patients
Cuizhen YUAN ; Feng ZE ; Ding LI ; Jiangbo DUAN ; Xu ZHOU ; Cuncao WU ; Jinshan HE ; Long WANG ; Xuebin LI
Chinese Circulation Journal 2025;40(2):170-174
Objectives:To analyze the clinical characteristics,strategies,success and complication rates of lead extraction and re-implantation during the upgrade of cardiovascular implantable electronic devices(CIED)in non-infectious patients.Methods:This retrospective study collected and analyzed the baseline clinical data and surgical data of 66 non-infected patients who had their existing CIEDs(including cardiac pacemaker,implantable cardioverter defibrillator[ICD],cardiac resynchronization therapy pacemaker[CRT-P])upgraded to ICD or CRT-P or cardiac resynchronization therapy defibrillator(CRT-D)or subcutaneous implantable cardioverter defibrillator(S-ICD)in Peking University People's Hospital from March 2018 to March 2024.We analyzed the strategies of lead extraction and reimplantation as well as the operation success rate and complication rate.Results:Among the 66 patients,preoperative imaging revealed that 12 patients(18.2%)had severe stenosis/occlusion of the venous access route,with lead wear/perforation in 26 patients(39.4%).32 patients(48.5%)underwent transvenous lead extraction(TLE),of which all leads were removed in 27 patients(84.4%),and only non-functional leads were removed in 5 patients(15.6%).The success rate of the TLE procedure was 100%and no complication occurred.Among the 66 patients,functional leads retained and new leads were implanted on the same side in 28 patients(42.4%),all leads were removed and new leads were reimplanted on the opposite side in 22 patients(33.3%),only non-functional leads were removed and new leads were reimplanted on the same side in 5 patients(7.6%),all leads were removed and new leads were reimplanted on the same side in 5 patients(7.6%),and 6 patients(9.1%)had the leads abandoned and then were re-implanled.The success rate of the upgrade surgery was 100%,no complications were reported.Conclusions:When the existing CIEDs(including cardiac pacemaker,ICD,CRT-P)of non-infected patients are upgraded to ICD,CRT-P,CRT-D or S-ICD,lead extraction and reimplantation are safe and feasible,and reimplantation can be performed on the ipsilateral or contralateral side.
7.Role of KMT2C in per- and polyfluoroalkyl substances induced liver cancer: A network toxicology and Mendelian randomization analysis
Nan OUYANG ; Wei XU ; Feng DONG ; Ze ZHU ; Xiaoqiong WU
Journal of Environmental and Occupational Medicine 2025;42(12):1510-1519
Background Per- and polyfluoroalkyl substances (PFAS) are persistent organic pollutants widely distributed in the environment. Epidemiological studies have shown that PFAS exposure is closely associated with liver dysfunction and an increased risk of liver cancer. Some animal and cell experiments have also revealed its hepatotoxicity and potential carcinogenicity; however, the related carcinogenic mechanism has not yet been fully elucidated. Objective To explore the potential molecular mechanism of PFAS-induced liver cancer, identify the key causal genes, and specifically evaluate the causal association and expression changes of KMT2C in this process, as well as the binding stability between KMT2C and PFAS, and to provid a theoretical basis for mechanistic studies and molecular target discovery in PFAS-related liver cancer. Methods Toxicity prediction was performed on six representative PFAS. Potential target genes of PFAS were identified by integrating results from SwissTargetPrediction, STITCH, and TargetNet databases. Liver cancer-related genes were retrieved from GeneCards, Online Mendelian Inheritance in Man (OMIM), and Therapeutic Target Database (TTD). The intersection of PFAS targets and liver cancer-related genes was used to obtain core genes. A compound-gene-disease regulatory network was constructed, and a protein–protein interaction network was established using STRING database. A core gene network was visualized based on node degree values. Gene Ontology (GO) and Kyoto Encyclopedia of Genes and Genomes (KEGG) enrichment analyses were performed to explore biological functions and enriched signaling pathways. Subsequently, two-sample Mendelian randomization was employed to assess potential causal relationships between candidate genes and hepatocellular carcinoma, enabling the identification of key genes. Molecular docking analysis using AutoDock was conducted to evaluate the binding stability between KMT2C and PFAS, and TCGA data were used to validate the differential expression of KMT2C between hepatocellular carcinoma and adjacent normal tissues. Results PFAS exhibited multisystem toxicity and posed significant risks of liver injury and carcinogenesis. A total of 266 PFAS target genes and
8.Problems and suggestions of medical equipment and devices in plateau field conditions
Lei LIANG ; Jiang-hui HAO ; Ze-rui ZHANG ; Feng ZHOU ; Can-hua XU ; Tao ZHANG
Chinese Medical Equipment Journal 2025;46(3):86-89
The characteristics of plateau field conditions and the application of the medical equipment and devices were summarized.The influences of plateau field conditions on the use and maintenance of the medical equipment and devices were pointed out,and some countermeasures were put forward accordingly.The causes for the problems were analyzed,and some suggestions were proposed from the aspects of top-level design,standard and personnel training.References were provided for the use and maintenance of medical equipment and devices during stationed field training and support for military operations other than war in plateau field areas.[Chinese Medical Equipment Journal,2025,46(3):86-89]
9.Retrospective Clinical Analysis on Lead Extraction and Reimplantation Strategies,Success and Complication Rates During Upgrade of Cardiovascular Implantable Electronic Devices in Non-infected Patients
Cuizhen YUAN ; Feng ZE ; Ding LI ; Jiangbo DUAN ; Xu ZHOU ; Cuncao WU ; Jinshan HE ; Long WANG ; Xuebin LI
Chinese Circulation Journal 2025;40(2):170-174
Objectives:To analyze the clinical characteristics,strategies,success and complication rates of lead extraction and re-implantation during the upgrade of cardiovascular implantable electronic devices(CIED)in non-infectious patients.Methods:This retrospective study collected and analyzed the baseline clinical data and surgical data of 66 non-infected patients who had their existing CIEDs(including cardiac pacemaker,implantable cardioverter defibrillator[ICD],cardiac resynchronization therapy pacemaker[CRT-P])upgraded to ICD or CRT-P or cardiac resynchronization therapy defibrillator(CRT-D)or subcutaneous implantable cardioverter defibrillator(S-ICD)in Peking University People's Hospital from March 2018 to March 2024.We analyzed the strategies of lead extraction and reimplantation as well as the operation success rate and complication rate.Results:Among the 66 patients,preoperative imaging revealed that 12 patients(18.2%)had severe stenosis/occlusion of the venous access route,with lead wear/perforation in 26 patients(39.4%).32 patients(48.5%)underwent transvenous lead extraction(TLE),of which all leads were removed in 27 patients(84.4%),and only non-functional leads were removed in 5 patients(15.6%).The success rate of the TLE procedure was 100%and no complication occurred.Among the 66 patients,functional leads retained and new leads were implanted on the same side in 28 patients(42.4%),all leads were removed and new leads were reimplanted on the opposite side in 22 patients(33.3%),only non-functional leads were removed and new leads were reimplanted on the same side in 5 patients(7.6%),all leads were removed and new leads were reimplanted on the same side in 5 patients(7.6%),and 6 patients(9.1%)had the leads abandoned and then were re-implanled.The success rate of the upgrade surgery was 100%,no complications were reported.Conclusions:When the existing CIEDs(including cardiac pacemaker,ICD,CRT-P)of non-infected patients are upgraded to ICD,CRT-P,CRT-D or S-ICD,lead extraction and reimplantation are safe and feasible,and reimplantation can be performed on the ipsilateral or contralateral side.
10.The impact of implantable cardioverter defibrillator with lead alert function on inappropriate shocks caused by lead malfunctions
Cuizhen YUAN ; Feng ZE ; Cuncao WU ; Jiangbo DUAN ; Xu ZHOU ; Dandan YANG ; Ding LI ; Xuebin LI
Chinese Journal of Cardiology 2025;53(12):1398-1403
Objective:To evaluate the incidence and frequency of inappropriate shocks caused by defibrillation lead failure in patients with implantable cardioverter-defibrillators (ICD), and to explore methods for reducing the incidence and frequency of such inappropriate shocks.Methods:This was a single-center retrospective study involving patients treated for defibrillation lead failures at Peking University People′s Hospital between March 2015 and May 2024. Patients were divided into an alarm function group and a non-alarm function group based on whether their ICDs were equipped with lead alarm functions. Clinical data, lead data, and the incidence and frequency of inappropriate shocks were collected and compared between the two groups. A multivariate logistic regression model was used to analyze factors influencing the incidence and frequency of inappropriate ICD shocks. Kaplan-Meier survival curves were plotted to compare the trends in the incidence and frequency of inappropriate shocks over time since ICD implantation between the two groups.Results:A total of 59 patients were enrolled, with a age of (56.7±15.2) years, including 42 males (71%). The lifespan of the failed leads in the entire cohort was 64.0 (36.0, 96.0) months. There were 26 patients in the alarm function group and 33 in the non-alarm function group. The most common manifestations of lead failure were oversensing (85%, 50/59) and abnormal pacing impedance (42%, 25/59). A total of 33 patients (56%, 33/59) experienced inappropriate shock therapy, with an average of 27.3 shocks per patient. The frequency of inappropriate ICD shocks in the non-alarm function group was higher than that in the alarm function group (25.0 (10.0, 60.0) times/year vs. 5.0 (2.8, 7.8) times/year, P=0.001). Multivariate logistic regression analysis showed that oversensing ( OR=2.057, 95% CI 1.125-6.763, P=0.019) was an influencing factor for incidence of inappropriate shocks, while the lead alert function ( OR=0.062, 95% CI 0.005-0.719, P=0.001) was a factor influencing the frequency of inappropriate shocks. Kaplan-Meier survival analysis revealed that the incidence and frequency of inappropriate shocks increased with the duration of ICD implantation in both groups, but the differences were not statistically significant (incidence: log-rank P=0.908; frequency: log-rank P=0.767). Conclusion:The lead alert function can reduce the frequency of inappropriate shocks caused by lead failure.

Result Analysis
Print
Save
E-mail