1.Common characteristics and regulatory mechanisms of airway mucus hypersecretion in lung disease.
Ze-Qiang LIN ; Shi-Man PANG ; Si-Yuan ZHU ; Li-Xia HE ; Wei-Guo KONG ; Wen-Ju LU ; Zi-Li ZHANG
Acta Physiologica Sinica 2025;77(5):989-1000
In a healthy human, the airway mucus forms a thin, protective liquid layer covering the surface of the respiratory tract. It comprises a complex blend of mucin, multiple antibacterial proteins, metabolic substances, water, and electrolytes. This mucus plays a pivotal role in the lungs' innate immune system by maintaining airway hydration and capturing airborne particles and pathogens. However, heightened mucus secretion in the airway can compromise ciliary clearance, obstruct the respiratory tract, and increase the risk of pathogen colonization and recurrent infections. Consequently, a thorough exploration of the mechanisms driving excessive airway mucus secretion is crucial for establishing a theoretical foundation for the eventual development of targeted drugs designed to reduce mucus production. Across a range of lung diseases, excessive airway mucus secretion manifests with unique characteristics and regulatory mechanisms, all intricately linked to mucin. This article provides a comprehensive overview of the characteristics and regulatory mechanisms associated with excessive airway mucus secretion in several prevalent lung diseases.
Humans
;
Mucus/metabolism*
;
Mucins/physiology*
;
Lung Diseases/metabolism*
;
Respiratory Mucosa/metabolism*
;
Pulmonary Disease, Chronic Obstructive/physiopathology*
;
Asthma/physiopathology*
;
Cystic Fibrosis/physiopathology*
;
Mucociliary Clearance/physiology*
2.Feasibility study of subcutaneous implantable cardioverter-defibrillator after transvenous lead extraction
Cuizhen YUAN ; Feng ZE ; Ding LI ; Cuncao WU ; Jinshan HE ; Yi WEI ; Jingliang ZHOU ; Xuebin LI
Chinese Journal of Cardiology 2025;53(10):1141-1145
Objective:To evaluate the clinical feasibility of subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation following transvenous lead extraction (TLE).Methods:This was a retrospective study. Consecutive patients who underwent S-ICD implantation at Peking University People′s Hospital between June 2015 and October 2023 were enrolled. Patients were divided into the TLE group and the newly implanted group based on whether they received TLE prior to S-ICD implantation. Baseline characteristics, S-ICD indication, defibrillation threshold test results, complications, and postoperative follow-up data were collected and compared between the two groups.Results:A total of 27 patients were included, aged (49.2±14.2) years, including 19 males. There were 12 patients in the TLE group and 15 in the newly implanted group. Compared with the TLE group, patients in the newly implanted group were younger ((43.3±13.7) years vs. (55.6±12.0) years, P=0.013). The main S-ICD indication in the TLE group was high infection risk (9/12), whereas in the newly implanted group it was younger age (11/15). All patients underwent successful S-ICD implantation, with 18 patients completing defibrillation threshold testing (all successful). Additionally, the TLE group had longer follow-up duration than the newly implanted group (42 (19, 60) months vs. 12 (3, 28) months, P=0.001). No complications or deaths occurred during follow-up, with normal device function in both groups. A total of 17 ventricular tachycardia or fibrillation events were recorded, of which 7 met defibrillation criteria and all received effective therapy. Conclusion:S-ICD demonstrates safety and efficacy as a therapeutic option for patients after TLE, with comparable device functionality and follow-up outcomes to patients with newly implanted S-ICD.
3.Progress on Wastewater-based Epidemiology in China: Implementation Challenges and Opportunities in Public Health.
Qiu da ZHENG ; Xia Lu LIN ; Ying Sheng HE ; Zhe WANG ; Peng DU ; Xi Qing LI ; Yuan REN ; De Gao WANG ; Lu Hong WEN ; Ze Yang ZHAO ; Jianfa GAO ; Phong K THAI
Biomedical and Environmental Sciences 2025;38(11):1354-1358
Wastewater-based epidemiology has emerged as a transformative surveillance tool for estimating substance consumption and monitoring disease prevalence, particularly during the COVID-19 pandemic. It enables the population-level monitoring of illicit drug use, pathogen prevalence, and environmental pollutant exposure. In this perspective, we summarize the key challenges specific to the Chinese context: (1) Sampling inconsistencies, necessitating standardized 24-hour composite protocols with high-frequency autosamplers (≤ 15 min/event) to improve the representativeness of samples; (2) Biomarker validation, requiring rigorous assessment of excretion profiles and in-sewer stability; (3) Analytical method disparities, demanding inter-laboratory proficiency testing and the development of automated pretreatment instruments; (4) Catchment population dynamics, reducing estimation uncertainties through mobile phone data, flow-based models, or hydrochemical parameters; and (5) Ethical and data management concerns, including privacy risks for small communities, mitigated through data de-identification and tiered reporting platforms. To address these challenges, we propose an integrated framework that features adaptive sampling networks, multi-scale wastewater sample banks, biomarker databases with multidimensional metadata, and intelligent data dashboards. In summary, wastewater-based epidemiology offers unparalleled scalability for equitable health surveillance and can improve the health of the entire population by providing timely and objective information to guide the development of targeted policies.
China/epidemiology*
;
Humans
;
Wastewater/analysis*
;
COVID-19/epidemiology*
;
Public Health
;
Wastewater-Based Epidemiological Monitoring
;
SARS-CoV-2
4.Analysis of the Development and Implementation of the Environmental Damage Compensation System in Japan
Kai HE ; Jin-Long YUAN ; Chang-Mao QIU ; Ze-Jun LIU ; Yuan-Feng QI ; Zhen-Hui GAO
Journal of Forensic Medicine 2025;41(1):74-82
In the 1950s and 1960s,Japan's implementation of policies prioritizing economic develop-ment caused a lack of effective supervision over the discharge of industrial wastewater and exhaust gases,which led to the occurrence of the"Four Major Pollution Diseases",including Minamata disease,causing serious social and public health problems.To more effectively address public nuisances and pro-vide compensation to victims,the Japanese government gradually established an environmental damage compensation system with administrative relief characteristics since the 1970s.Through long-term prac-tice and system optimization,this system has evolved into a mature institutional framework with a clear division of labor and efficient collaboration.This paper systematically reviews the development process of Japan's environmental damage compensation system and deeply analyzes its legal frame-work and supporting policies,aiming to provide useful references for the construction and improve-ment of China's environmental damage compensation system.Meanwhile,through the case analysis of Minamata disease,the paper explores the specific mechanisms and effects in the compensation practices,further revealing the system's operational characteristics and implications,and providing a reference ba-sis for the construction of China's environmental governance legal system.
5.Prognostic Value of Dynamic Monitoring of WT1 Expression Levels for Relapse and Overall Survival in AML Patients Undergoing Allogeneic Hematopoietic Stem Cell Transplantation During First Complete Remission
Xiao-Ya HE ; Han-Yun REN ; Yu-Jun DONG ; Li JI ; Qing-Yun WANG ; Yuan LI ; Yue YIN ; Ze-Yin LIANG ; Qian WANG ; Wei-Lin XU ; Jin-Ping OU ; Bing-Jie WANG ; Wei LIU
Journal of Experimental Hematology 2025;33(6):1790-1796
Objective:To analyze the predictive role of WT1 expression levels pre-and early post-transplantation on relapse and overall survival(OS)in patients with acute myeloid leukemia(AML)undergoing allogeneic hematopoietic stem cell transplantation(allo-HSCT)during their first complete remission(CR1).Methods:A retrospective analysis was conducted on the clinical data of 107 adult AML patients who underwent allo-HSCT during their CR1 at our center between May 2012 and December 2021.The predictive role of bone marrow WT1 expression levels before transplantation and at 3 and 6 months post-transplantation on relapse and OS was explored in combination with relevant clinical factors.Results:The median follow-up time for the 107 patients was 70(range:11-117)months.Among the patients,15 cases died.Kaplan-Meier survial analysis showed that the 3-year overall survival(OS)rate was 85.0%.20 patients experienced relapse,with a median time to relapse of 8(range:0.5-44)months and a l-year cumulative relapse rate of 13.1%.The overall median value of WT1 before transplantation,3 months after transplantation,and 6 months after transplantation was 0.26%(range:0%-23.64%),with an upper quartile value of 0.74%.No statistically significant differences in WT1 expression levels were observed among the pre-transplantation,3-month post-transplantation,and 6-month post-transplantation time points(P=0.227).Univariate analysis showed that patients with WT1 levels>0.74%at 3 months post-transplantation had a higher 1-year relapse rate(P=0.029)and lower 3-year OS rate(P<0.001)compared to patients with WT1 levels ≤0.74%.Other significant factors affecting 1-year relapse included stem cell source(P=0.041)and chronic graft-versus-host disease(cGVHD)(P=0.013).For 3-year OS,additional influencing factors were genetic high risk(P=0.048)and stem cell source(P=0.016).Multivariate analysis revealed that WT1 level>0.74%at 3 months post-transplantation had a trend to affect 1-year relapse rate(HR=3.309,95%CI:0.958-11.431,P=0.058),while the absence of cGVHD was an independent risk factor for 1-year relapse(HR=3.473,95%CI:0.749-16.100,P=0.037).Only WT1 level>0.74%at 3 months post-transplantation was an independent risk factor for 3-year OS(HR=6.886,95%CI:2.402-19.738,P<0.001).Conclusion:High WT1 expression level at 3 months post-transplantation in AML patients undergoing allo-HSCT during CR1 affects the 1-year relapse rate and 3-year OS,and is an independent risk factor affecting 3-year OS.These findings suggest that dynamic monitoring of WT1 expression levels has certain value in prognostic assessment of AML patients who received allo-HSCT during CR1.
6.Retrospective Clinical Analysis on Lead Extraction and Reimplantation Strategies,Success and Complication Rates During Upgrade of Cardiovascular Implantable Electronic Devices in Non-infected Patients
Cuizhen YUAN ; Feng ZE ; Ding LI ; Jiangbo DUAN ; Xu ZHOU ; Cuncao WU ; Jinshan HE ; Long WANG ; Xuebin LI
Chinese Circulation Journal 2025;40(2):170-174
Objectives:To analyze the clinical characteristics,strategies,success and complication rates of lead extraction and re-implantation during the upgrade of cardiovascular implantable electronic devices(CIED)in non-infectious patients.Methods:This retrospective study collected and analyzed the baseline clinical data and surgical data of 66 non-infected patients who had their existing CIEDs(including cardiac pacemaker,implantable cardioverter defibrillator[ICD],cardiac resynchronization therapy pacemaker[CRT-P])upgraded to ICD or CRT-P or cardiac resynchronization therapy defibrillator(CRT-D)or subcutaneous implantable cardioverter defibrillator(S-ICD)in Peking University People's Hospital from March 2018 to March 2024.We analyzed the strategies of lead extraction and reimplantation as well as the operation success rate and complication rate.Results:Among the 66 patients,preoperative imaging revealed that 12 patients(18.2%)had severe stenosis/occlusion of the venous access route,with lead wear/perforation in 26 patients(39.4%).32 patients(48.5%)underwent transvenous lead extraction(TLE),of which all leads were removed in 27 patients(84.4%),and only non-functional leads were removed in 5 patients(15.6%).The success rate of the TLE procedure was 100%and no complication occurred.Among the 66 patients,functional leads retained and new leads were implanted on the same side in 28 patients(42.4%),all leads were removed and new leads were reimplanted on the opposite side in 22 patients(33.3%),only non-functional leads were removed and new leads were reimplanted on the same side in 5 patients(7.6%),all leads were removed and new leads were reimplanted on the same side in 5 patients(7.6%),and 6 patients(9.1%)had the leads abandoned and then were re-implanled.The success rate of the upgrade surgery was 100%,no complications were reported.Conclusions:When the existing CIEDs(including cardiac pacemaker,ICD,CRT-P)of non-infected patients are upgraded to ICD,CRT-P,CRT-D or S-ICD,lead extraction and reimplantation are safe and feasible,and reimplantation can be performed on the ipsilateral or contralateral side.
7.Prognostic Value of Dynamic Monitoring of WT1 Expression Levels for Relapse and Overall Survival in AML Patients Undergoing Allogeneic Hematopoietic Stem Cell Transplantation During First Complete Remission
Xiao-Ya HE ; Han-Yun REN ; Yu-Jun DONG ; Li JI ; Qing-Yun WANG ; Yuan LI ; Yue YIN ; Ze-Yin LIANG ; Qian WANG ; Wei-Lin XU ; Jin-Ping OU ; Bing-Jie WANG ; Wei LIU
Journal of Experimental Hematology 2025;33(6):1790-1796
Objective:To analyze the predictive role of WT1 expression levels pre-and early post-transplantation on relapse and overall survival(OS)in patients with acute myeloid leukemia(AML)undergoing allogeneic hematopoietic stem cell transplantation(allo-HSCT)during their first complete remission(CR1).Methods:A retrospective analysis was conducted on the clinical data of 107 adult AML patients who underwent allo-HSCT during their CR1 at our center between May 2012 and December 2021.The predictive role of bone marrow WT1 expression levels before transplantation and at 3 and 6 months post-transplantation on relapse and OS was explored in combination with relevant clinical factors.Results:The median follow-up time for the 107 patients was 70(range:11-117)months.Among the patients,15 cases died.Kaplan-Meier survial analysis showed that the 3-year overall survival(OS)rate was 85.0%.20 patients experienced relapse,with a median time to relapse of 8(range:0.5-44)months and a l-year cumulative relapse rate of 13.1%.The overall median value of WT1 before transplantation,3 months after transplantation,and 6 months after transplantation was 0.26%(range:0%-23.64%),with an upper quartile value of 0.74%.No statistically significant differences in WT1 expression levels were observed among the pre-transplantation,3-month post-transplantation,and 6-month post-transplantation time points(P=0.227).Univariate analysis showed that patients with WT1 levels>0.74%at 3 months post-transplantation had a higher 1-year relapse rate(P=0.029)and lower 3-year OS rate(P<0.001)compared to patients with WT1 levels ≤0.74%.Other significant factors affecting 1-year relapse included stem cell source(P=0.041)and chronic graft-versus-host disease(cGVHD)(P=0.013).For 3-year OS,additional influencing factors were genetic high risk(P=0.048)and stem cell source(P=0.016).Multivariate analysis revealed that WT1 level>0.74%at 3 months post-transplantation had a trend to affect 1-year relapse rate(HR=3.309,95%CI:0.958-11.431,P=0.058),while the absence of cGVHD was an independent risk factor for 1-year relapse(HR=3.473,95%CI:0.749-16.100,P=0.037).Only WT1 level>0.74%at 3 months post-transplantation was an independent risk factor for 3-year OS(HR=6.886,95%CI:2.402-19.738,P<0.001).Conclusion:High WT1 expression level at 3 months post-transplantation in AML patients undergoing allo-HSCT during CR1 affects the 1-year relapse rate and 3-year OS,and is an independent risk factor affecting 3-year OS.These findings suggest that dynamic monitoring of WT1 expression levels has certain value in prognostic assessment of AML patients who received allo-HSCT during CR1.
8.Retrospective Clinical Analysis on Lead Extraction and Reimplantation Strategies,Success and Complication Rates During Upgrade of Cardiovascular Implantable Electronic Devices in Non-infected Patients
Cuizhen YUAN ; Feng ZE ; Ding LI ; Jiangbo DUAN ; Xu ZHOU ; Cuncao WU ; Jinshan HE ; Long WANG ; Xuebin LI
Chinese Circulation Journal 2025;40(2):170-174
Objectives:To analyze the clinical characteristics,strategies,success and complication rates of lead extraction and re-implantation during the upgrade of cardiovascular implantable electronic devices(CIED)in non-infectious patients.Methods:This retrospective study collected and analyzed the baseline clinical data and surgical data of 66 non-infected patients who had their existing CIEDs(including cardiac pacemaker,implantable cardioverter defibrillator[ICD],cardiac resynchronization therapy pacemaker[CRT-P])upgraded to ICD or CRT-P or cardiac resynchronization therapy defibrillator(CRT-D)or subcutaneous implantable cardioverter defibrillator(S-ICD)in Peking University People's Hospital from March 2018 to March 2024.We analyzed the strategies of lead extraction and reimplantation as well as the operation success rate and complication rate.Results:Among the 66 patients,preoperative imaging revealed that 12 patients(18.2%)had severe stenosis/occlusion of the venous access route,with lead wear/perforation in 26 patients(39.4%).32 patients(48.5%)underwent transvenous lead extraction(TLE),of which all leads were removed in 27 patients(84.4%),and only non-functional leads were removed in 5 patients(15.6%).The success rate of the TLE procedure was 100%and no complication occurred.Among the 66 patients,functional leads retained and new leads were implanted on the same side in 28 patients(42.4%),all leads were removed and new leads were reimplanted on the opposite side in 22 patients(33.3%),only non-functional leads were removed and new leads were reimplanted on the same side in 5 patients(7.6%),all leads were removed and new leads were reimplanted on the same side in 5 patients(7.6%),and 6 patients(9.1%)had the leads abandoned and then were re-implanled.The success rate of the upgrade surgery was 100%,no complications were reported.Conclusions:When the existing CIEDs(including cardiac pacemaker,ICD,CRT-P)of non-infected patients are upgraded to ICD,CRT-P,CRT-D or S-ICD,lead extraction and reimplantation are safe and feasible,and reimplantation can be performed on the ipsilateral or contralateral side.
9.Feasibility study of subcutaneous implantable cardioverter-defibrillator after transvenous lead extraction
Cuizhen YUAN ; Feng ZE ; Ding LI ; Cuncao WU ; Jinshan HE ; Yi WEI ; Jingliang ZHOU ; Xuebin LI
Chinese Journal of Cardiology 2025;53(10):1141-1145
Objective:To evaluate the clinical feasibility of subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation following transvenous lead extraction (TLE).Methods:This was a retrospective study. Consecutive patients who underwent S-ICD implantation at Peking University People′s Hospital between June 2015 and October 2023 were enrolled. Patients were divided into the TLE group and the newly implanted group based on whether they received TLE prior to S-ICD implantation. Baseline characteristics, S-ICD indication, defibrillation threshold test results, complications, and postoperative follow-up data were collected and compared between the two groups.Results:A total of 27 patients were included, aged (49.2±14.2) years, including 19 males. There were 12 patients in the TLE group and 15 in the newly implanted group. Compared with the TLE group, patients in the newly implanted group were younger ((43.3±13.7) years vs. (55.6±12.0) years, P=0.013). The main S-ICD indication in the TLE group was high infection risk (9/12), whereas in the newly implanted group it was younger age (11/15). All patients underwent successful S-ICD implantation, with 18 patients completing defibrillation threshold testing (all successful). Additionally, the TLE group had longer follow-up duration than the newly implanted group (42 (19, 60) months vs. 12 (3, 28) months, P=0.001). No complications or deaths occurred during follow-up, with normal device function in both groups. A total of 17 ventricular tachycardia or fibrillation events were recorded, of which 7 met defibrillation criteria and all received effective therapy. Conclusion:S-ICD demonstrates safety and efficacy as a therapeutic option for patients after TLE, with comparable device functionality and follow-up outcomes to patients with newly implanted S-ICD.
10.The impact of programming optimization for atrioventricular synchrony after Micra AV leadless pacemakers implantation
Ze ZHENG ; Yu-Chen SHI ; Song-Yuan HE ; Shao-Ping WANG ; Shi-Ying LI ; Shu-Juan CHENG ; Jing-Hua LIU
Chinese Journal of Interventional Cardiology 2024;32(2):71-75
Objective To analyze the atrioventricular synchronization rate after implantation of Micra AV leadless pacemaker,and the impact of postoperative programming optimization on atrioventricular synchronization rate.Methods A prospective cohort study was conducted to select patients with complete atrioventricular block who underwent Micra AV leadless pacemaker implantation at Beijing Anzhen Hospital from August 2022 to June 2023.Programming optimization were performed at 1 week,1 month,and 3 months postoperatively,and atrioventricular synchronization rate,electrical parameters,and echocardiography were recorded.Results A total of 68 patients with complete atrioventricular block implanted with Micra AV were selected,with an average age of(68.2±9.7)years,including 47 males(69.1%).All patients were successfully implanted with Micra AV,and there were no serious postoperative complications;The average threshold,sense,and impedance parameters were stable during 1 week,1 month,and 3 months after the procedure;There was no significant difference in the EF value of postoperative echocardiography(P=0.162);The average atrioventricular synchronization rates at 1 week,1 month,and 3 months postoperatively were(75.2%vs.83.8%vs.91.6%,P=0.001).Conclusions As an mechanical atrial sensing,Micra AV requires personalized adjustment of relevant parameters;Postoperative follow-up programming optimization plays an important role in the atrioventricular synchronization and comfort level in patients with complete atrioventricular block after implantation of Micra AV leadless pacemaker.

Result Analysis
Print
Save
E-mail