1.Finite element analysis comparing lumbar fusion and artificial intervertebral disc replacement
Jingang ZHAO ; Liping LIU ; Jianwei CHEN
Chinese Journal of Tissue Engineering Research 2026;30(3):553-560
BACKGROUND:Lumbar degenerative disease is a disease of the musculoskeletal system that primarily affects the intervertebral structures,and the disease is treated with lumbar fusion and disc replacement.OBJECTIVE:To conduct comparative analysis of the differences between lumbar fusion,mechanical lumbar disc prosthesis replacement,and viscoelastic lumbar disc prosthesis replacement.METHODS:The computerized tomography images of a healthy adult were used to construct a finite element model of the L2-L5 normal lumbar spine with Mimic,Geomagic,and Ansys software.The equipment required for lumbar fusion and lumbar spine replacement was constructed using modeling software,and the L3-L4 segment of the lumbar spine was processed according to the surgical requirements for lumbar fusion and intervertebral disc replacement,creating the corresponding finite element model.Specific boundary conditions were applied to extract the mobility of each lumbar spine segment,the stresses on the neighboring intervertebral discs,and the stresses on the prosthesis lining.RESULTS AND CONCLUSION:(1)Compared with the preoperative period,the maximum stress in the upper neighboring discs increased by 64.09%and 39.79%in the forward flexion and lateral bending states if the original mobility was maintained after lumbar fusion surgery.The maximum stress in the lower neighboring discs increased by 24.39%and 20.98%in forward flexion and lateral bending.This suggested that the upper adjacent discs would suffer greater stress changes than the lower adjacent discs during heavy physical labor.(2)Disc replacement did not show significant changes in adjacent disc stress,with mechanical prosthesis replacement slightly reducing adjacent disc stress,while viscoelastic prosthesis replacement was more in line with the biological properties of the disc,with maximum adjacent disc stress similar to that of the preoperative period.(3)In terms of stability,the mechanical prosthesis replacement segment showed a 51.67%increase in range of motion in the lateral bending state and a 53.27%increase in range of motion in the posterior extension state,whereas the viscoelastic prosthesis was better able to maintain mobility in the replacement segment.(4)In addition,the stresses in the liner of the mechanical prosthesis were mainly concentrated in the edge region,and this stress distribution may lead to edge wear and thus affect the service life of the prosthesis.
2.Finite element analysis comparing lumbar fusion and artificial intervertebral disc replacement
Jingang ZHAO ; Liping LIU ; Jianwei CHEN
Chinese Journal of Tissue Engineering Research 2026;30(3):553-560
BACKGROUND:Lumbar degenerative disease is a disease of the musculoskeletal system that primarily affects the intervertebral structures,and the disease is treated with lumbar fusion and disc replacement.OBJECTIVE:To conduct comparative analysis of the differences between lumbar fusion,mechanical lumbar disc prosthesis replacement,and viscoelastic lumbar disc prosthesis replacement.METHODS:The computerized tomography images of a healthy adult were used to construct a finite element model of the L2-L5 normal lumbar spine with Mimic,Geomagic,and Ansys software.The equipment required for lumbar fusion and lumbar spine replacement was constructed using modeling software,and the L3-L4 segment of the lumbar spine was processed according to the surgical requirements for lumbar fusion and intervertebral disc replacement,creating the corresponding finite element model.Specific boundary conditions were applied to extract the mobility of each lumbar spine segment,the stresses on the neighboring intervertebral discs,and the stresses on the prosthesis lining.RESULTS AND CONCLUSION:(1)Compared with the preoperative period,the maximum stress in the upper neighboring discs increased by 64.09%and 39.79%in the forward flexion and lateral bending states if the original mobility was maintained after lumbar fusion surgery.The maximum stress in the lower neighboring discs increased by 24.39%and 20.98%in forward flexion and lateral bending.This suggested that the upper adjacent discs would suffer greater stress changes than the lower adjacent discs during heavy physical labor.(2)Disc replacement did not show significant changes in adjacent disc stress,with mechanical prosthesis replacement slightly reducing adjacent disc stress,while viscoelastic prosthesis replacement was more in line with the biological properties of the disc,with maximum adjacent disc stress similar to that of the preoperative period.(3)In terms of stability,the mechanical prosthesis replacement segment showed a 51.67%increase in range of motion in the lateral bending state and a 53.27%increase in range of motion in the posterior extension state,whereas the viscoelastic prosthesis was better able to maintain mobility in the replacement segment.(4)In addition,the stresses in the liner of the mechanical prosthesis were mainly concentrated in the edge region,and this stress distribution may lead to edge wear and thus affect the service life of the prosthesis.
3.Risk prediction model and validation of respiratory failure in patients with sepsis
Jianwei ZHAO ; Qi WANG ; Chengkang LU ; Xia LI
Journal of Public Health and Preventive Medicine 2026;37(4):91-95
Objective To analyze the influencing factors of respiratory failure in patients with sepsis, and to construct and validate a risk prediction model. Methods A total of 308 patients with sepsis in Ganzi Tibetan Autonomous Prefecture People's Hospital from August 2021 to September 2024 were enrolled and divided into a modeling group and a validation group. According to whether respiratory failure occurred during hospitalization, the patients were divided into a respiratory failure group and a non-respiratory failure group. Single-factor and binary logistic regression analysis were used to construct a risk prediction model, and the ROC, calibration, and DCA curves were used to assess the model's predictive performance. Results The incidence of respiratory failure was 20.83% (45/216) in the modeling group and 20.65% (19/92) in the validation group. Albumin, D-dimer, serum calcium, procalcitonin at admission, and sequential organ failure assessment were independent influencing factors of respiratory failure in patients with sepsis. The ROC curve analysis nomogram model predicted that the AUC of respiratory failure in the modeling group was 0.994 (95%CI: 0.985-1.000), and the AUC of the validation group was 0.897 (95%CI: 0.826-0.968). The calibration curve analysis showed that the calibration curve fit well with the ideal curve. DCA curve analysis showed that the net benefit was greater than 0 across all threshold probability ranges. Conclusion The risk prediction model constructed in this study is highly effective and can provide reference for medical staff to evaluate respiratory failure in patients with sepsis.
4.Monitoring results of key occupational hazard factors in manufacturing enterprises in Jiading District
ZHAO Jianwei ; MENG Wei ; PAN Li ; YU Hongjie ; CHEN Xiaogui
Journal of Preventive Medicine 2026;38(10):1006-1011
Objective:
To analyze the monitoring results of key occupational hazard factors in manufacturing enterprises in Jiading District, Shanghai Municipality, so as to provide a basis for differentiated occupational disease prevention and control.
Methods:
In December 2025, data on key occupational hazard factors in monitored enterprises in Jiading District from 2020 to 2025 were collected through the Workplace Occupational Hazard Monitoring System, including enterprise size, industry type and economic ownership type. A descriptive analysis was conducted on the over-standard status of eight key occupational hazard factors, the configuration of protective facilities, the setup of warning signs, the distribution of personal protective equipment, and the results of occupational health examinations in manufacturing enterprises.
Results:
A total of 359 manufacturing enterprises were monitored, with 3 182 monitoring positions and 661 over-standard positions, with an over-standard rate of 20.77%. The over-standard rate of noise was 43.54%, and over-standard rates were relatively high in large enterprises, automobile manufacturing industry and Hong Kong, Macao and Taiwan-invested enterprises, at 52.03%, 56.05% and 63.78%, respectively. The over-standard rate of silica dust was 13.57%, and the over-standard rates were relatively high in medium-sized enterprises, metal products industry and Hong Kong, Macao and Taiwan-invested enterprises, at 20.00%, 22.22% and 46.15%, respectively. The over-standard rate of welding fume was 0.91%, and over-standard rates were relatively high in small enterprises, metal products industry and Hong Kong, Macao and Taiwan-invested enterprises, at 1.21%, 2.94% and 7.69%, respectively. The over-standard rates of chemical factors ranged from 0 to 3.69%. Among them, the over-standard rates of toluene and xylene were relatively high in micro enterprises (6.82% and 6.67%). while the over-standard rate of manganese and its compounds was relatively high in small enterprises (1.05%). The over-standard rate of toluene was relatively high in the general equipment manufacturing industry (6.25%), the over-standard rate of xylene was relatively high in the special equipment manufacturing industry (20.00%), and the over-standard rate of manganese and its compounds was relatively high in the metal products industry (2.94%). The over-standard rate of toluene was relatively high in foreign-invested enterprises, at 3.06%; the over-standard rate of xylene was relatively high in domestic-invested enterprises, at 4.05%; and the over-standard rate of manganese and its compounds was relatively high in Hong Kong, Macao and Taiwan-invested enterprises, at 2.70%. The setting rates of protective facilities for noise, productive dust and chemical factors were 40.23%, 86.08% and 81.99%, respectively. The distribution rates of personal protective equipment were 93.29%, 88.29% and 71.38%, respectively. The rates of required re-examinations for noise, welding fume and benzene were relatively high, at 5.62%, 2.23% and 2.20%, respectively. With the exception of ethylbenzene, the completion rates of re-examinations for the other seven occupational hazard factors all exceeded 70.00%. The abnormal rate of noise-related physical examinations was relatively high, at 2.42%.
Conclusions
The over-standard rate of occupational hazard factor positions in manufacturing enterprises was relatively low in Jiading District. Noise and silica dust were the key targets for prevention and control. The setting rate of protective facilities and the distribution rate of personal protective equipment still need to be improved, and the overall completion rate of re-examinations was relatively high.
5.Relationship Between Gastroesophageal Reflux Disease-Related Symptoms and Clinicopathologic Characteristics and Long-Term Survival of Patients with Esophageal Adenocarcinoma in China
Kan ZHONG ; Xin SONG ; Ran WANG ; Mengxia WEI ; Xueke ZHAO ; Lei MA ; Quanxiao XU ; Jianwei KU ; Lingling LEI ; Wenli HAN ; Ruihua XU ; Jin HUANG ; Zongmin FAN ; Xuena HAN ; Wei GUO ; Xianzeng WANG ; Fuqiang QIN ; Aili LI ; Hong LUO ; Bei LI ; Lidong WANG
Cancer Research on Prevention and Treatment 2025;52(8):661-665
Objective To investigatethe relationship between gastroesophageal reflux disease (GERD) symptoms and clinicopathological characteristics, p53 expression, and survival of Chinese patients with esophageal adenocarcinoma. Methods A total of
6.Early assessment of responsive neurostimulation for drug-resistant epilepsy in China: A multicenter, self-controlled study.
Yanfeng YANG ; Penghu WEI ; Jianwei SHI ; Ying MAO ; Jianmin ZHANG ; Ding LEI ; Zhiquan YANG ; Shiwei SONG ; Ruobing QIAN ; Wenling LI ; Yongzhi SHAN ; Guoguang ZHAO
Chinese Medical Journal 2025;138(4):430-440
BACKGROUND:
To evaluate the efficacy and safety of the first cohort of people in China treated with a responsive neurostimulation system (Epilcure TM , GenLight MedTech, Hangzhou, China) for focal drug-resistant epilepsy in this study.
METHODS:
This multicenter, before-and-after self-controlled study was conducted across 8 centers from March 2022 to June 2023, involving patients with drug-resistant epilepsy who were undergoing responsive neurostimulation (RNS). The study was based on an ongoing multi-center, single-blind, randomized controlled study. Efficacy was assessed through metrics including median seizure count, seizure frequency reduction (SFR), and response rate. Multivariable linear regression analysis was conducted to explore the relationships of basic clinical factors and intracranial electrophysiological characteristics with SFR. The postoperative quality of life, cognitive function, depression, and anxiety were evaluated as well.
RESULTS:
The follow-up period for the 19 participants was 10.7 ± 3.4 months. Seizure counts decreased significantly 6 months after device activation, with median SFR of 48% at the 6th month (M6) and 58% at M12 ( P <0.05). The average response rate after 13 months of treatment was 42%, with 21% ( n = 4) of the participants achieving seizure freedom. Patients who have previously undergone resective surgery appear to achieve better therapeutic outcomes at M11, M12 and M13 ( β <0, P <0.05). No statistically significant differences were observed in patients' scores of quality of life, cognition, depression and anxiety following stimulation when compared to baseline measurements. No serious adverse events related to the devices were observed.
CONCLUSIONS:
The preliminary findings suggest that Epilcure TM exhibits promising therapeutic potential in reducing the frequency of epileptic seizures. However, to further validate its efficacy, larger-scale randomized controlled trials are required.
REGISTRATION
Chinese Clinical Trial Registry (No. ChiCTR2200055247).
Humans
;
Female
;
Male
;
Drug Resistant Epilepsy/therapy*
;
Adult
;
Young Adult
;
Middle Aged
;
China
;
Adolescent
;
Treatment Outcome
;
Quality of Life
;
Single-Blind Method
;
Seizures
;
Electric Stimulation Therapy/methods*
7.Increasing trends of hyperglycemia and diabetes in treatment-naive people living with HIV in Shenzhen from 2013 to 2019: An emerging health concern.
Liqin SUN ; Haipeng ZHU ; Man RAO ; Fang ZHAO ; Yang ZHOU ; Lukun ZHANG ; Xia SHI ; Jianwei WU ; Yun HE ; Hongzhou LU ; Jiaye LIU
Chinese Medical Journal 2025;138(16):2043-2045
8.18F-FDG PET/CT metabolic parameters for prediction of treatment response to neoadjuvant immunochemotherapy in locally advanced gastric cancer
Peng LI ; Shuang LU ; Weiwei ZHAO ; Yanmei LI ; Xianhua HAN ; Xiaofeng ZHANG ; Jianwei YANG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2025;45(11):648-653
Objective:To investigate the value of midtreatment 18F-FDG PET/CT metabolic parameters for predicting the pathological response in patients with locally advanced gastric cancer (LAGC) after neoadjuvant immunochemotherapy (NICT). Methods:Twenty-five LAGC patients (19 males, 6 females, age: (64.8±8.6) years) who underwent 18F-FDG PET/CT after NICT in Henan Cancer Hospital from August 2019 to June 2024 were retrospectively analyzed. The lesion′s ROI was delineated, then the SUV max and metabolic tumor volume (MTV) were measured, and the SUV max was divided by SUV mean of the descending aorta to obtain the tumor-to-background ratio (TBR). Patients underwent surgery after PET/CT imaging. Based on the tumor regression grade (TRG) system by the American Joint Committee on Cancer (AJCC) criteria on surgical specimen, patients were divided into responders (TRG0+ 1) and non-responders (TRG2+ 3). Independent-sample t test, Mann-Whitney U test, one-way analysis of variance, and Kruskal-Wallis rank-sum test were used to compare the differences of data. The predictive efficacy of PET/CT metabolic parameters was assessed by the ROC curve analysis. Results:Postsurgical pathology showed that 9 patients were responders and 16 were non-responders. The SUV max (3.10±1.95) and TBR (2.44±1.54) of primary lesions in responders were lower than those in non-responders (7.40±4.68, 5.85±3.74; t values: -2.61, -2.59, both P<0.05), while the MTV of primary tumors and short diameter and metabolic parameters of positive lymph nodes were not significantly different between those 2 groups ( t=-1.50, Z values: -1.09 to -0.75, all P>0.05). No significant relation was found between PET/CT parameters and pathological differentiation or Lauren classification, or other pathological features ( t values: -1.55 to 1.38, Z values: -1.84 to 0, F values: 0.12-2.43, H values: 0.13-0.98, all P>0.05). ROC curve showed that the cut-off value of SUV max for predicting postoperative TRG was 5.40, and the AUC reached 0.77 (95% CI: 0.56-0.91), with the sensitivity and specificity of 9/16, 9/9, respectively. With TBR=3.54 as the cut-off value, its AUC reached 0.77 (95% CI: 0.56-0.91), and the sensitivity and specificity were 11/16, 8/9, respectively. The sensitivity and specificity of PET/CT for predicting lymph node positivity of patients were 8/12 and 13/13, respectively. Conclusion:Interim 18F-FDG PET/CT metabolic parameters can accurately predict the pathological response of LAGC patients after NICT.
9.Predictive value of pan-immune-inflammation index for major adverse cardiovascular events within 1 year after PCI in elderly patients with coronary heart disease
Tao SUN ; Zhiyin DAI ; Xuan LI ; Chaopu ZHANG ; Shu DING ; Jianwei ZHAO
Journal of Jilin University(Medicine Edition) 2025;51(6):1655-1660
Objective:To discuss the clinical value of pan-immune inflammation index(PIV)in predicting the major adverse cardiovascular events(MACE)within 1 year after percutaneous coronary intervention(PCI)in the elderly patients with coronary heart disease,and to clarify the role of inflammatory response in postoperative recovery and prognosis of the patients with coronary heart disease.Methods:A total of 150 elderly patients with coronary heart disease who underwent PCI from July 2020 to August 2023 were selected as the research subjects;according to the occurrence of MACE within 1 year after operation,they were divided into MACE group(n=28)and non-MACE group(n=122);the baseline data and biochemical indicators of the patients were collected,and PIV was calculated;multivariate Logistic regression was used to analyze the influencing factors of MACE within 1 year after PCI in the elderly patients with coronary heart disease;receiver operating characteristic(ROC)curve was used to analyze the predictive value of PIV for MACE within 1 year after PCI in the elderly patients with coronary heart disease.Results:Compared with non-MACE group,the levels of total cholesterol(TC)and low-density lipoprotein cholesterol(LDL-C),neutrophils(NEUT),platelets(PLT)counting and PIV in the patients in MACE group were significantly increased(P<0.05);there were no significant differences in other data between two groups(P>0.05).The multivariate Logistic regression analysis results showed that the levels of TC(OR=1.571,95%CI:1.088-2.270)and LDL-C(OR=32.506,95%CI:8.880-118.994)and PIV(OR=1.014,95%CI:1.010-1.019)were the influencing factors of MACE within 1 year after PCI in the elderly patients with coronary heart disease(P<0.05).The ROC curve analysis results showed that the area under the ROC curve(AUC)of PIV for predicting MACE was 0.857(95%CI:0.762-0.951),the sensitivity was 0.821,the specificity was 0.959,the maximum Youden index was 0.780,and the best cut-off value was 778.805(P<0.01).Conclusion:PIV has important predictive value for MACE within 1 year after PCI in elderly patients with coronary heart disease.
10.1 case of recurrent nasal vestibular aggressive angiomyxoma.
Yaqin WANG ; Jianwei AI ; Jingyi ZHAO ; Yuezhi KANG ; Suying GUO ; Junge WANG
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(9):886-893
Invasive angiomyxoma(AAM) is characterized by unclear boundaries, non enveloped glial growth, high recurrence rate, and belongs to a benign tumor, but it is invasive and grows slowly. A patient with recurrent left vestibular invasive angiomyxoma was admitted to the Otorhinolaryngology ward of Beijing Traditional Chinese Medicine Hospital Affiliated with Capital Medical University. The patient underwent two repeated surgeries and underwent a combined internal and external nasal approach for the removal of the nasal vestibular angiomyxoma. The patient recovered well after the surgery and has not recurred since follow-up.
Humans
;
Myxoma/pathology*
;
Neoplasm Recurrence, Local
;
Nose Neoplasms/pathology*


Result Analysis
Print
Save
E-mail