1.Artificial intelligence-based quality control of hand hygiene for hospital-acquired infection
Xuchen YANG ; Jingwen LI ; Wan ZHANG ; Shasha FENG ; Min ZENG ; Jianan SHI ; Youqiong CHEN ; Tao ZHENG ; Xun YAO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(02):241-247
Objective To explore an artificial intelligence (AI)-based method for automated hand hygiene monitoring and to compare the effectiveness of three algorithms (UniFormerV2, TDN, C3D) in recognizing hand hygiene steps in surgical settings, thereby aiding hospital infection control. Methods From April to October 2024, we non-invasively collected 641 video recordings of healthcare staff performing hand hygiene at four-bay scrub sinks in two tertiary hospitals using overhead HD cameras. The dataset was annotated by five trained experts for model training and validation. Results Following training on 385 samples, internal validation (n=119) showed the C3D model achieved 81% accuracy, 87% recall, and an 83% F1-score. The TDN model achieved 93%, 91%, and 92% for the same metrics. The UniFormerV2 model outperformed both, with an accuracy, recall, and F1-score of 93%—an improvement of over 10 percentage points compared to traditional CNNs (TDN, C3D). It also achieved an 84% accuracy in external validation, demonstrating strong generalization. Conclusion The UniFormerV2 model is more accurate than CNN-based models for hand hygiene step recognition and shows robust performance in external validation. It presents a viable tool for healthcare facilities to enhance hand hygiene management, ultimately improving medical quality and patient safety.
2.Tension hydrocele: report of 2 cases and literature review
Xun ZHAO ; Shumin WANG ; Min QIU ; Chuxiao XU ; Guoliang WANG ; Shudong ZHANG
Journal of Modern Urology 2025;30(1):69-72
[Objective] To explore the diagnosis and treatment experience of tension hydrocele. [Methods] The clinical data of 2 patients with tension hydrocele treated in our hospital were retrospectively analyzed.Relevant literature was retrieved to analyze the clinical characteristics of this disease. [Results] Case 1 was diagnosed due to swelling and pain of the left scrotum after trauma for more than one month, which worsened for one day.Physical examination showed high tension in the left scrotum and positive light transmission test.Ultrasound examination revealed that the blood flow signal in the left testis disappeared.Emergency left scrotal exploration and hydrocelectomy were performed.There was no sign of testis torsion during the operation.Case 2 was diagnosed mainly due to hydrocele of the right testis for 1 year, which worsened for 1 week and complicated with testis distension and pain.Physical examination showed high tension in the right scrotum and positive light transmission test.Ultrasound examination revealed that the blood flow signal in the right testis decreased.After 40ml of fluid was extracted under ultrasound monitoring, the blood flow signal in the right testis recovered.Hydrocelectomy was performed the next day.During the follow-up of 8 months, there was no recurrence of hydrocele.A search of domestic and foreign literature showed that there were no reports in domestic literature, while a total of 11 cases were reported in foreign literature. [Conclusion] Tension hydrocele of the testis is a rare emergency of the scrotum.Surgery or decompression should be performed as soon as possible to restore testicular blood supply, and hydrocelectomy should be performed simultaneously or in stages to prevent recurrence.
3.Comparison of SEC-RI-MALLS and SEC-RID methods for determining molecular weight and molecular weight distribution of PLGA
WANG Baocheng ; ZHANG Xiaoyan ; ZHOU Xiaohua ; ZHAO Xun ; MA Congyu ; GAO Zhengsong ; SHI Haiwei ; YUAN Yaozuo ; HANG Taijun
Drug Standards of China 2025;26(1):110-116
Objective: To establish a method for determining the molecular weight and molecular weight distribution of Poly(Lactide-co-Glycolide Acid) (PLGA) using Size Exclusion Chromatography-Refractive Index-Multiangle Laser Light Scattering (SEC-RI-MALLS) and Size Exclusion Chromatography-Refractive Index (SEC-RID), and to compare the results obtained from these two methods.
Methods: For SEC-RI-MALLS, tetrahydrofuran was used as the mobile phase, Shodex GPC KF-803L was employed as the chromatographic column with a flow rate of 1 mL·min-1, column temperature at 30 ℃, and an injection volume of 100 μL. For SEC-RID, tetrahydrofuran was also used as the mobile phase, Agilent PLgel 5 μm MIXD-D was used as the chromatographic column with a flow rate of 1 mL·min-1, column temperature at 30 ℃, differential detector temperature at 35 ℃, and an injection volume of 20 μL. The molecular weight and molecular weight distribution were calculated using Agilent’s GPC software. The newly established methods were validated methodologically, and the molecular weight and molecular weight distribution of 13 batches of samples were determined.
Results: The precision, accuracy, stability, and repeatability tests for SEC-RI-MALLS showed RSD values of 1.35%, 1.58%, 1.53%, and 1.26%, respectively. The SEC-RID method exhibited good linearity (r=0.999 9), with RSD values for precision, accuracy, stability, and repeatability tests (n=6) of 2.05%, 1.62%, 1.30%, and 2.97%, respectively. The results obtained from SEC-RI-MALLS were lower than those from SEC-RID, and the molecular weight distribution coefficient was smaller, but the results from the paired T-test performed with the value measured by SEC-RID method and the value measured by SEC-RI-MALLS method multiplied a conversion coefficient of 1.5 showed no significant difference between the two methods.
Conclusion: Both methods are stable and reliable, and can be used for the determination of PLGA molecular weight and molecular weight distribution based on the specific situations.
4.Primary prostatic signet ring cell carcinoma:a report of 6 cases and literature review
Xiaofeng WANG ; Chengbiao CHU ; Xun WANG ; Tingzheng WANG ; Feifei ZHANG ; Wei CHEN ; Linfeng XU ; Qing ZHANG ; Hongqian GUO
Journal of Modern Urology 2025;30(4):290-295
Objective: To explore the diagnosis, treatment and prognosis of primary prostatic signet ring cell carcinoma (SRCC), so as to provide reference for the clinical diagnosis and treatment. Methods: A retrospective analysis was conducted on the clinical data of 6 patients with primary prostatic SRCC treated in Nanjing Drum Tower Hospital during Nov.2020 and Sep.2024.The clinical manifestations, imaging features, treatment methods, histological characteristics and prognosis were summarized. Results: The average age of the patients was (72.00±4.28) years.Varying degrees of dysuria occurred in 4 patients. All patients underwent multi-parametric magnetic resonance imaging (mpMRI) examination before surgery, and the results indicated typical prostate cancer.Preoperative biopsies showed high-grade (Gleason 8-10) prostate acinar adenocarcinoma.Postoperative pathological diagnoses were mixed types of prostate acinar adenocarcinoma and SRCC, and no metastasis was found in the pelvic lymph nodes.All patients were followed up for 1 to 46 months after surgery and are currently alive.Robot-assisted laparoscopic radical prostatectomy only was performed in 3 cases; apalutamide and leuprolide/triptorelin was administered after surgery in 2 cases; bicalutamide + goserelin was administered after surgery in 1 case, who developed bladder metastasis of prostate cancer 24 months later, and the serum prostate-specific antigen (PSA) concentration decreased to a safe level (<0.2 ng/mL) after the use of darolutamide with radiotherapy.No recurrence or metastasis was found in the remaining patients. Conclusion: Primary prostatic SRCC is a rare and highly aggressive malignant tumor of the prostate.The diagnosis depends on pathological examinations due to lack of specific imaging features and clinical manifestations.The prognosis is poor, and there is currently no standardized treatment.The combined use of surgery, hormonotherapy and radiotherapy can help improve the survival rate of patients.
5.Integration and innovation of wet granulation and continuous manufacturing technology: a review of on-line detection, modeling, and process scale-up.
Guang-di YANG ; Ge AO ; Yang CHEN ; Yu-Fang HUANG ; Shu CHEN ; Dong-Xun LI ; Wen-Liu ZHANG ; Tian-Tian WANG ; Guo-Song ZHANG
China Journal of Chinese Materia Medica 2025;50(6):1484-1495
Continuous manufacturing, as an innovative pharmaceutical production model, offers advantages such as high production efficiency and ease of control compared to traditional batch production, aligning with the future trend of drug production moving toward greater efficiency and intelligence. However, the development of continuous manufacturing technology in wet granulation has been slow. On one hand, this is closely related to its high technical complexity, substantial equipment investment costs, and stringent process control requirements. On the other hand, the long-term use of the traditional batch production model has created strong path dependence, and the lack of mature standardized processes further increases the difficulty of technological transformation. To promote the deep integration of wet granulation technology with continuous manufacturing, this review systematically outlines the current application of wet granulation in continuous manufacturing. It focuses on the development of key technologies such as online detection, process modeling, and process scale-up, with the aim of providing a reference for process innovation and application in wet granulation.
Drug Compounding/instrumentation*
;
Technology, Pharmaceutical/methods*
;
Drugs, Chinese Herbal/chemistry*
;
Models, Theoretical
6.Standardization of electronic medical records data in rehabilitation
Yifan TIAN ; Fang XUN ; Haiyan YE ; Ye LIU ; Yingxin ZHANG ; Yaru YANG ; Zhongyan WANG ; Meng ZHANG ; Xiaoxie LIU ; Yanyan YANG ; Bin ZENG ; Mouwang ZHOU ; Yuxiao XIE ; Guangxu XU ; Jiejiao ZHENG ; Mingsheng ZHANG ; Xiangming YE ; Fubiao HUANG ; Qiuchen HUANG ; Yiji WANG ; Di CHEN ; Zhuoying QIU
Chinese Journal of Rehabilitation Theory and Practice 2025;31(1):33-44
ObjectiveTo explore the data standard system of electronic medical records in the field of rehabilitation, focusing on the terminology and coding standards, data structure, and key content categories of rehabilitation electronic medical records. MethodsBased on the Administrative Norms for the Application of Electronic Medical Records issued by the National Health Commission of China, the electronic medical record standard architecture issued by the International Organization for Standardization and Health Level Seven (HL7), the framework of the World Health Organization Family of International Classifications (WHO-FICs), Basic Architecture and Data Standards of Electronic Medical Records, Basic Data Set of Electronic Medical Records, and Specifications for Sharing Documents of Electronic Medical Records, the study constructed and organized the data structure, content, and data standards of rehabilitation electronic medical records. ResultsThe data structure of rehabilitation electronic medical records should strictly follow the structure of electronic medical records, including four levels (clinical document, document section, data set and data element) and four major content areas (basic information, diagnostic information, intervention information and cost information). Rehabilitation electronic medical records further integrated information related to rehabilitation needs and characteristics, emphasizing rehabilitation treatment, into clinical information. By fully applying the WHO-FICs reference classifications, rehabilitation electronic medical records could establish a standardized framework, diagnostic criteria, functional description tools, coding tools and terminology index tools for the coding, indexing, functional description, and analysis and interpretation of diseases and health problems. The study elaborated on the data structure and content categories of rehabilitation electronic medical records in four major categories, refined the granularity of reporting rehabilitation content in electronic medical records, and provided detailed data reporting guidance for rehabilitation electronic medical records. ConclusionThe standardization of rehabilitation electronic medical records is significant for improving the quality of rehabilitation medical services and promoting the rehabilitation process of patients. The development of rehabilitation electronic medical records must be based on the national and international standards. Under the general electronic medical records data structure and standards, a rehabilitation electronic medical records data system should be constructed which incorporates core data such as disease diagnosis, functional description and assessment, and rehabilitation interventions. The standardized rehabilitation electronic medical records scheme constructed in this study can support the improvement of standardization of rehabilitation electronic medical records data information.
7.Protective effect of Shenfu injection against neonatal hypoxic-ischemic brain injury by inhibiting the ferroptosis
Xiaotong Zhang ; Meng Zhang ; Gang Li ; Yang Hu ; Yajing Xun ; Hui Ding ; Donglin Shen ; Ming Wu
Acta Universitatis Medicinalis Anhui 2025;60(1):31-40
Objective :
To observe the brain tissue injury during hypoxia-ischemia, as well as the pathological changes and the expression of ferroptosis-related factors after the use of Shenfu injection(SFI), and to explore the protective effect of SFI on hypoxic-ischemic brain injury(HIBD) by inhibiting ferroptosis.
Methods :
An animal model of HIBD in SD rats was constructed and intervened with SFI. Pathologic changes in brain tissue were observed by HE staining methods. Nissen staining was used to observe neuron survival. Glutathione Peroxidase 4(GPX4) and Divalent Metal Transporter 1(DMT1) expression were detected in brain tissue by Western blot, immunohistochemistry and immunofluorescence. Reduced Glutathione(GSH), Lactate Dehydrogenase(LDH), Malondialdehyde(MDA), Superoxide Dismutase(SOD) and tissue iron content were determined with the kits. BV-2 microglial cell line(BV2) cells were culturedin vitroand divided into control group(Ctrl group), oxygen-glucose deprivation group(OGD group), iron ferroptosis-inducing group(Erastin group), iron ferroptosis-inhibiting group(Fer-1 group), Shenfu injection group(SFI group), and Erastin+Shenfu injection group(Erastin+SFI group). 2′,7′-Dichlorodihydrofluorescein diacetate(DCFH-DA) reactive oxygen species(ROS) fluorescent probe was used to detect the ROS release level; Immunofluorescence was used to observe intracellular GPX4, DMT1 expression.
Results :
Compared with the Sham group, rats in the HIBD group showed significant neuronal cell damage in brain tissue, decreased GPX4 expression(P<0.01), increased DMT1 expression(P<0.01), decreased GSH and SOD levels(P<0.01), and increased LDH, MDA and tissue iron levels(P<0.05,P<0.05,P<0.01). In contrast, after the intervention of SFI, GPX4 expression was elevated(P<0.01), DMT1 expression decreased(P<0.01), GSH and SOD levels were elevated(P<0.01), and LDH, MDA, and tissue iron levels decreased(P<0.05,P<0.05,P<0.01). The cells experiments showed that compared with the Ctrl group, the OGD group had a significantly higher ROS content and a decrease in the expression of GPX4 fluorescence intensity, and an increase in the fluorescence intensity of DMT1(P<0.01), compared with the OGD group, the ROS content was reduced in the SFI group, while the expression of GPX4 was elevated and the expression of DMT1 was reduced(P<0.01).
Conclusion
Hippocampal and cortical regions are severely damaged after HIBD in neonatal rats, and their brain tissues show decreased expression of GPX4 and increased expression of DMT1. The above suggests that ferroptosis is involved in HIBD brain injury in neonatal rats. In contrast, Shenfu injection has a protective effect on HIBD experimental animal model and BV2 cell injury model by reducing iron aggregation and ROS production.
8.Validating Multicenter Cohort Circular RNA Model for Early Screening and Diagnosis of Gestational Diabetes Mellitus
Shuo MA ; Yaya CHEN ; Zhexi GU ; Jiwei WANG ; Fengfeng ZHAO ; Yuming YAO ; Gulinaizhaer ABUDUSHALAMU ; Shijie CAI ; Xiaobo FAN ; Miao MIAO ; Xun GAO ; Chen ZHANG ; Guoqiu WU
Diabetes & Metabolism Journal 2025;49(3):462-474
Background:
Gestational diabetes mellitus (GDM) is a metabolic disorder posing significant risks to maternal and infant health, with a lack of effective early screening markers. Therefore, identifying early screening biomarkers for GDM with higher sensitivity and specificity is urgently needed.
Methods:
High-throughput sequencing was employed to screen for key circular RNAs (circRNAs), which were then evaluated using reverse transcription quantitative polymerase chain reaction. Logistic regression analysis was conducted to examine the relationship between clinical characteristics, circRNA expression, and adverse pregnancy outcomes. The diagnostic accuracy of circRNAs for early and mid-pregnancy GDM was assessed using receiver operating characteristic curves. Pearson correlation analysis was utilized to explore the relationship between circRNA levels and oral glucose tolerance test results. A predictive model for early GDM was established using logistic regression.
Results:
Significant alterations in circRNA expression profiles were detected in GDM patients, with hsa_circ_0031560 and hsa_ circ_0000793 notably upregulated during the first and second trimesters. These circRNAs were associated with adverse pregnancy outcomes and effectively differentiated GDM patients, with second trimester cohorts achieving an area under the curve (AUC) of 0.836. In first trimester cohorts, these circRNAs identified potential GDM patients with AUCs of 0.832 and 0.765, respectively. The early GDM prediction model achieved an AUC of 0.904, validated in two independent cohorts.
Conclusion
Hsa_circ_0031560, hsa_circ_0000793, and the developed model serve as biomarkers for early prediction or midterm diagnosis of GDM, offering clinical tools for early GDM screening.
9.Validating Multicenter Cohort Circular RNA Model for Early Screening and Diagnosis of Gestational Diabetes Mellitus
Shuo MA ; Yaya CHEN ; Zhexi GU ; Jiwei WANG ; Fengfeng ZHAO ; Yuming YAO ; Gulinaizhaer ABUDUSHALAMU ; Shijie CAI ; Xiaobo FAN ; Miao MIAO ; Xun GAO ; Chen ZHANG ; Guoqiu WU
Diabetes & Metabolism Journal 2025;49(3):462-474
Background:
Gestational diabetes mellitus (GDM) is a metabolic disorder posing significant risks to maternal and infant health, with a lack of effective early screening markers. Therefore, identifying early screening biomarkers for GDM with higher sensitivity and specificity is urgently needed.
Methods:
High-throughput sequencing was employed to screen for key circular RNAs (circRNAs), which were then evaluated using reverse transcription quantitative polymerase chain reaction. Logistic regression analysis was conducted to examine the relationship between clinical characteristics, circRNA expression, and adverse pregnancy outcomes. The diagnostic accuracy of circRNAs for early and mid-pregnancy GDM was assessed using receiver operating characteristic curves. Pearson correlation analysis was utilized to explore the relationship between circRNA levels and oral glucose tolerance test results. A predictive model for early GDM was established using logistic regression.
Results:
Significant alterations in circRNA expression profiles were detected in GDM patients, with hsa_circ_0031560 and hsa_ circ_0000793 notably upregulated during the first and second trimesters. These circRNAs were associated with adverse pregnancy outcomes and effectively differentiated GDM patients, with second trimester cohorts achieving an area under the curve (AUC) of 0.836. In first trimester cohorts, these circRNAs identified potential GDM patients with AUCs of 0.832 and 0.765, respectively. The early GDM prediction model achieved an AUC of 0.904, validated in two independent cohorts.
Conclusion
Hsa_circ_0031560, hsa_circ_0000793, and the developed model serve as biomarkers for early prediction or midterm diagnosis of GDM, offering clinical tools for early GDM screening.
10.Overlapping Reflux Symptoms in Functional Dyspepsia Are Mostly Unrelated to Gastroesophageal Reflux
Songfeng CHEN ; Xingyu JIA ; Qianjun ZHUANG ; Xun HOU ; Kewin T H SIAH ; Mengyu ZHANG ; Fangfei CHEN ; Niandi TAN ; Junnan HU ; Yinglian XIAO
Journal of Neurogastroenterology and Motility 2025;31(2):218-226
Background/Aims:
Reflux symptoms frequently present in patients diagnosed with functional dyspepsia (FD). This investigation sought to elucidate the contribution of gastroesophageal reflux in the overlap relationship.
Methods:
Consecutive patients presenting with reflux symptoms and/or FD symptoms were prospectively included. Comprehensive assessments, including symptoms evaluation, endoscopy, esophageal functional examinations (high-resolution manometry and reflux monitoring), and proton pump inhibitor (PPI) treatment efficacy evaluation, were conducted in these patients.
Results:
The study enrolled 315 patients, 43.2% of which had concurrent FD symptoms and overlapping reflux symptoms. Notably, a mere 28.7% of patients in the overlap symptoms group had objective gastroesophageal reflux disease evidences (the grade of esophagitis≥ B or the acid exposure time ≥ 4.2%). Functional heartburn was demonstrated to be the main cause of overlapping reflux symptoms(55.1%). Reflux parameters analysis revealed that the reflux burden in the overlap symptoms group paralleled that of the FD symptoms group, with both registering lower levels than the reflux symptoms group (P < 0.05). Furthermore, PPI response rates were notably diminished in the overlap symptoms group (P < 0.001), even for those with objective gastroesophageal reflux disease evidences.
Conclusions
The study illuminated that overlapping reflux symptoms in FD was common. Strikingly, these symptoms primarily diverged from reflux etiology and exhibited suboptimal responses to PPI intervention. These findings challenge prevailing paradigms and accentuate the imperative for nuanced therapeutic approaches tailored to the distinctive characteristics of overlapping reflux symptoms in the context of FD.


Result Analysis
Print
Save
E-mail