1.Improving the Certainty of Evidence in Animal Experiment Systematic Review/Meta-Analysis: An Empirical Study of the GRADE Method
Tengfei LI ; Qingyong ZHENG ; Jianguo XU ; Yiyi LI ; Yongjia ZHOU ; Caihua XU ; Mingyue ZHANG ; Jiexiang TIAN ; Gang WANG ; Jinhui TIAN
Laboratory Animal and Comparative Medicine 2025;45(1):101-111
Animal experiments are essential tools in biomedical research, serving as a bridge between basic research and clinical trials. Systematic reviews and meta-analyses (SRs/MAs) of animal experiments are crucial methods for integrating evidence from animal experiment, which can facilitate the translation of findings into clinical research, reduce translational risks, and promote resource integration in basic research. With the continuous development of the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) methodology, its application in SRs/MAs of animal experiments has gained increasing attention. This article first outlines the principles and specific applications of the GRADE methodology in SRs/MAs of animal experiments, including qualitative descriptive systematic reviews, meta-analyses, and network meta-analyses. It then deeply analyzes the misuse of the GRADE methodology in practice, including incorrect evidence grading, improper classification of evidence, misapplication in qualitative systematic reviews, inconsistencies between the documentation of the upgrading and downgrading process and results, and inappropriate use for making recommendations. Furthermore, this article comprehensively discusses the factors influencing the grading of evidence certainty in SRs/MAs of animal experiments, including the impact of bias risk, indirectness, inconsistency, imprecision, and publication bias on evidence downgrading, as well as the role of large effect sizes and cross-species consistency in evidence upgrading. Finally, in response to the issues discussed, improvement strategies are proposed, including further research and optimization of the GRADE methodology for SRs/MAs of animal experiments, the development of reporting guidelines tailored to the characteristics of SRs/MAs in animal experiment research, and enhanced professional training for researchers in the GRADE methodology. This article aims to improve the quality of evidence in SRs/MAs of animal experiments, strengthen their reliability in clinical decision-making, and promote the more efficient translation of findings from animal experiment research into clinical practice.
2.Monitoring results of mosquito-ovitraps placed in different orientations in multi-storey residential areas
Caixiong LIU ; Bin GE ; Haibing ZHANG ; Lin WANG ; Tao YANG ; Yujiao WEI ; Haiying XIE ; Yu ZHANG ; Hongxia LIU ; Juntao SHEN
Shanghai Journal of Preventive Medicine 2025;37(2):109-113
ObjectiveTo find out whether there is any difference in the monitoring results of mosq-ovitraps placed in different orientations in multi-storey residential areas, so as to provide a scientific basis for routine and emergency monitoring of Aedes albopictus with mosq-ovitraps in residential areas. MethodsFrom July 6th to October 26th 2023, one mosquito ovitrap was set up in each of the 4 orientations of east, south, west and north around the buildings in a multi-storey residential area in Jinhui Town, Fengxian District, Shanghai. Data was collected and recorded 72 hours after placement. The chi-square test was used to compare the mosquito ovitrap indices (MOIs) of two independent samples, and the Kruskal⁃Wallis H test was used to compare the MOIs of multiple independent samples. ResultsAfter 16 weeks of surveillance, 997 mosquito ovitraps were recovered, of which 211 were positive, with the mosquito ovitrap index (MOI) of 21.16% and the Aedes albopictus density index of 1.03 mosquitoes·ovitrap-1. The MOIs were higher in September (24.22%) and October (23.96%), and the MOIs in the west, south and north within the two months were all above 20.00%. From July to October, the MOIs in the east, west, south and north were 20.70%, 22.20%, 25.50% and 16.20%, respectively, and the difference in MOIs among the 4 orientations was not statistically significant (χ2=6.647, P=0.084). Stratified analysis by month showed that in August, the south side of the multi-storey residential areas had the highest MOI (31.30%), the north side had the lowest MOI (1.30%), and there was a statistically significant difference in MOI in the east, west, south and north (χ2=25.986, P<0.001). In October, the MOI in the west was the highest (33.30%) and the MOI in the east was the lowest (6.30%), the difference in MOIs of the 4 orientations was statistically significant (χ2=12.007, P=0.007). The MOIs in the south side of the building in the outskirts of the residential area from the 1st week in July to the 4th week in October was lower (19.20%) than that in the south side of the inner building (31.70%), and the difference in MOI was statistically significant (χ2=5.118, P=0.024). ConclusionThe study of MOI in different orientations in a multi-storey residential area is a preliminary exploration based on field work, and the results show that there is a difference in MOIs in different orientations during the peak breeding period of mosquitoes. Further indicators such as temperature, humidity and wind speed in different orientations can be collected to explore the influencing factors of MOIs.
3.Influence evaluation of pharmaceutical quality control on medication therapy management services by the ECHO model
Kun LIU ; Huanhuan JIANG ; Yushuang LI ; Yan HUANG ; Qianying ZHANG ; Dong CHEN ; Xiulin GU ; Jinhui FENG ; Zijian WANG ; Yunfei CHEN ; Yajuan QI ; Yanlei GE ; Aishuang FU
China Pharmacy 2025;36(9):1123-1128
OBJECTIVE To evaluate the influence of pharmaceutical quality control on the efficiency and outcomes of standardized medication therapy management (MTM) services for patients with coronary heart disease by using Economic, Clinical and Humanistic Outcomes (ECHO) model. METHODS This study collected case data of coronary heart disease patients who received MTM services during January-March 2023 (pre-quality control implementation group, n=96) and June-August 2023 (post-quality control implementation group, n=164). Using propensity score matching analysis, 80 patients were selected from each group. The study subsequently compared the economic, clinical, and humanistic outcome indicators of pharmaceutical services between the two matched groups. RESULTS There were no statistically significant differences in baseline data between the two groups after matching (P>0.05). Compared with pre-quality control implementation group, the daily treatment cost (16.26 yuan vs. 24.40 yuan, P<0.001), cost-effectiveness ratio [23.12 yuan/quality-adjusted life year (QALY) vs. 32.32 yuan/QALY, P<0.001], and the incidence of general adverse drug reactions (2.50% vs. 10.00%, P=0.049) of post-quality control implementation group were decreased significantly; the utility value of the EuroQol Five-Dimensional Questionnaire (0.74± 0.06 vs. 0.71±0.07, P=0.003), the reduction in the number of medication related problems (1.0 vs. 0.5, P<0.001), the medication adherence score ([ 6.32±0.48) points vs. (6.10±0.37) points, P=0.001], and the satisfaction score ([ 92.56±1.52) points vs. (91.95±1.56) points, P=0.013] all showed significant improvements. Neither group experienced serious adverse drug reactions. There was no statistically significant difference in the incidence of new adverse reactions between the two groups (1.25% vs. 3.75%, P=0.310). CONCLUSIONS Pharmaceutical quality control can improve the quality of pharmaceutical care, and the ECHO model can quantitatively evaluate the effect of MTM services, making pharmaceutical care better priced and more adaptable to social needs, thus being worthy of promotion.
4.Establishment and validation of the determination method for the related substances in carbetocin injection
Yimiao CHEN ; Xiang ZHANG ; Jinhui WU ; Yuye Huang
Journal of China Pharmaceutical University 2025;56(1):65-72
An HPLC analytical method was developed to determine the related substances in carbetocin injection. The method was performed on a Waters Xbridge C18 column (150 mm×3 mm, 3.5 μm) with 0.30 mg/mL ammonium acetate-19% acetonitrile aqueous solution as mobile phase A and mobile phase A-acetonitrile (1∶1) as mobile phase B. The detection wavelength was 220 nm. Gradient elution was performed at the flow rate of 0.8 mL/min and the column temperature of 60℃. The method was validated for system applicability, specificity, linearity and range, accuracy, with the results that the 9 impurities of carbetocin injection showed good linearity (R²>0.999) with peak area in their respective concentration range, and that the method had good precision (RSD<5%). This method is suitable for the simultaneous determination of carbetocin and its 9 impurities in carbetocin injection and can provide a theoretical basis for the quality control of the carbetocin injection.
5.Guideline for the workflow of clinical comprehensive evaluation of drugs
Zhengxiang LI ; Rong DUAN ; Luwen SHI ; Jinhui TIAN ; Xiaocong ZUO ; Yu ZHANG ; Lingli ZHANG ; Junhua ZHANG ; Hualin ZHENG ; Rongsheng ZHAO ; Wudong GUO ; Liyan MIAO ; Suodi ZHAI
China Pharmacy 2025;36(19):2353-2365
OBJECTIVE To standardize the main processes and related technical links of the clinical comprehensive evaluation of drugs, and provide guidance and reference for improving the quality of comprehensive evaluation evidence and its transformation and application value. METHODS The construction of Guideline for the Workflow of Clinical Comprehensive Evaluation of Drugs was based on the standard guideline formulation method of the World Health Organization (WHO), strictly followed the latest definition of guidelines by the Institute of Medicine of the National Academy of Sciences of the United States, and conformed to the six major areas of the Guideline Research and Evaluation Tool Ⅱ. Delphi method was adopted to construct the research questions; research evidence was established by applying the research methods of evidence-based medicine. The evidence quality classification system of the Chinese Evidence-Based Medicine Center was adopted for evidence classification and evaluation. The recommendation strength was determined by the recommendation strength classification standard formulated by the Oxford University Evidence-Based Medicine Center, and the recommendation opinions were formed through the expert consensus method. RESULTS & CONCLUSIONS The Guideline for the Workflow of Clinical Comprehensive Evaluation of Drugs covers 4 major categories of research questions, including topic selection, evaluation implementation, evidence evaluation, and application and transformation of results. The formulation of this guideline has standardized the technical links of the entire process of clinical comprehensive evaluation of drugs, which can effectively guide the high-quality and high-efficient development of this work, enhance the standardized output and transformation application value of evaluation evidence, and provide high-quality evidence support for the scientific decision-making of health and the rationalization of clinical medication.
6.ResNet-Vision Transformer based MRI-endoscopy fusion model for predicting treatment response to neoadjuvant chemoradiotherapy in locally advanced rectal cancer: A multicenter study.
Junhao ZHANG ; Ruiqing LIU ; Di HAO ; Guangye TIAN ; Shiwei ZHANG ; Sen ZHANG ; Yitong ZANG ; Kai PANG ; Xuhua HU ; Keyu REN ; Mingjuan CUI ; Shuhao LIU ; Jinhui WU ; Quan WANG ; Bo FENG ; Weidong TONG ; Yingchi YANG ; Guiying WANG ; Yun LU
Chinese Medical Journal 2025;138(21):2793-2803
BACKGROUND:
Neoadjuvant chemoradiotherapy followed by radical surgery has been a common practice for patients with locally advanced rectal cancer, but the response rate varies among patients. This study aimed to develop a ResNet-Vision Transformer based magnetic resonance imaging (MRI)-endoscopy fusion model to precisely predict treatment response and provide personalized treatment.
METHODS:
In this multicenter study, 366 eligible patients who had undergone neoadjuvant chemoradiotherapy followed by radical surgery at eight Chinese tertiary hospitals between January 2017 and June 2024 were recruited, with 2928 pretreatment colonic endoscopic images and 366 pelvic MRI images. An MRI-endoscopy fusion model was constructed based on the ResNet backbone and Transformer network using pretreatment MRI and endoscopic images. Treatment response was defined as good response or non-good response based on the tumor regression grade. The Delong test and the Hanley-McNeil test were utilized to compare prediction performance among different models and different subgroups, respectively. The predictive performance of the MRI-endoscopy fusion model was comprehensively validated in the test sets and was further compared to that of the single-modal MRI model and single-modal endoscopy model.
RESULTS:
The MRI-endoscopy fusion model demonstrated favorable prediction performance. In the internal validation set, the area under the curve (AUC) and accuracy were 0.852 (95% confidence interval [CI]: 0.744-0.940) and 0.737 (95% CI: 0.712-0.844), respectively. Moreover, the AUC and accuracy reached 0.769 (95% CI: 0.678-0.861) and 0.729 (95% CI: 0.628-0.821), respectively, in the external test set. In addition, the MRI-endoscopy fusion model outperformed the single-modal MRI model (AUC: 0.692 [95% CI: 0.609-0.783], accuracy: 0.659 [95% CI: 0.565-0.775]) and the single-modal endoscopy model (AUC: 0.720 [95% CI: 0.617-0.823], accuracy: 0.713 [95% CI: 0.612-0.809]) in the external test set.
CONCLUSION
The MRI-endoscopy fusion model based on ResNet-Vision Transformer achieved favorable performance in predicting treatment response to neoadjuvant chemoradiotherapy and holds tremendous potential for enabling personalized treatment regimens for locally advanced rectal cancer patients.
Humans
;
Rectal Neoplasms/diagnostic imaging*
;
Magnetic Resonance Imaging/methods*
;
Male
;
Female
;
Middle Aged
;
Neoadjuvant Therapy/methods*
;
Aged
;
Adult
;
Chemoradiotherapy/methods*
;
Endoscopy/methods*
;
Treatment Outcome
8.Analysis of effectiveness of Holosight robot navigation-assisted percutaneous cannulated screw fixation in treatment of femoral neck fractures.
Weizhen XU ; Zhenqi DING ; Hui LIU ; Jinhui ZHANG ; Yuanfei XIONG ; Jin WU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):673-679
OBJECTIVE:
To investigate the effectiveness of Holosight robotic navigation-assisted percutaneous cannulated screw fixation for femoral neck fractures.
METHODS:
A retrospective analysis was conducted on 65 patients with femoral neck fractures treated with cannulated screw fixation between January 2022 and February 2024. Among them, 31 patients underwent robotic navigation-assisted screw placement (navigation group), while 34 underwent conventional freehand percutaneous screw fixation (freehand group). Baseline characteristics, including age, gender, fracture side, injury mechanism, Garden classification, Pauwels classification, and time from injury to operation, showed no significant differences between the two groups ( P>0.05). The operation time, intraoperative blood loss, fluoroscopy frequency, fracture healing time, and complications were recorded and compared, and hip function was evaluated by Harris score at last follow-up. Postoperative anteroposterior and lateral hip X-ray films were taken to assess screw distribution accuracy, including deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex.
RESULTS:
No significant difference was observed in operation time between the two groups ( P>0.05). However, the navigation group demonstrated superior outcomes in intraoperative blood loss, fluoroscopy frequency, deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex ( P<0.05). No incision infections or deep vein thrombosis occurred. All patients were followed up 12-18 months (mean, 16 months). In the freehand group, 1 case suffered from cannulated screw dislodgement and nonunion secondary to osteonecrosis of femoral head at 1 year after operation, 1 case suffered from screw penetration secondary to osteonecrosis of femoral head at 5 months after operation; and 1 case suffered from nonunion secondary to osteonecrosis of femoral head at 6 months after operation in the navigation group. All the 3 patients underwent internal fixators removal and total hip arthroplasty. There was no significant difference in the incidence of complications between the two groups ( P>0.05). The fracture healing time and hip Harris score at last follow-up in the navigation group were significantly better than those in the freehand group ( P<0.05).
CONCLUSION
Compared to freehand percutaneous screw fixation, Holosight robotic navigation-assisted cannulated screw fixation for femoral neck fractures achieves higher precision, reduced intraoperative radiation exposure, smaller incisions, and superior postoperative hip function recovery.
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Screws
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Retrospective Studies
;
Robotic Surgical Procedures/methods*
;
Middle Aged
;
Aged
;
Adult
;
Treatment Outcome
;
Operative Time
;
Fracture Healing
;
Surgery, Computer-Assisted/methods*
;
Fluoroscopy
9.Discovery of a novel AhR-CYP1A1 axis activator for mitigating inflammatory diseases using an in situ functional imaging assay.
Feng ZHANG ; Bei ZHAO ; Yufan FAN ; Lanhui QIN ; Jinhui SHI ; Lin CHEN ; Leizhi XU ; Xudong JIN ; Mengru SUN ; Hongping DENG ; Hairong ZENG ; Zhangping XIAO ; Xin YANG ; Guangbo GE
Acta Pharmaceutica Sinica B 2025;15(1):508-525
The aryl hydrocarbon receptor (AhR) plays a crucial role in regulating many physiological processes. Activating the AhR-CYP1A1 axis has emerged as a novel therapeutic strategy against various inflammatory diseases. Here, a practical in situ cell-based fluorometric assay was constructed to screen AhR-CYP1A1 axis modulators, via functional sensing of CYP1A1 activities in live cells. Firstly, a cell-permeable, isoform-specific enzyme-activable fluorogenic substrate for CYP1A1 was rationally constructed for in-situ visualizing the dynamic changes of CYP1A1 function in living systems, which was subsequently used for discovering the efficacious modulators of the AhR-CYP1A1 axis. Following screening of a compound library, LAC-7 was identified as an efficacious activator of the AhR-CYP1A1 axis, which dose-dependently up-regulated the expression levels of both CYP1A1 and AhR in multiple cell lines. LAC-7 also suppressed macrophage M1 polarization and reduced the levels of inflammatory factors in LPS-induced bone marrow-derived macrophages. Animal tests showed that LAC-7 could significantly mitigate DSS-induced ulcerative colitis and LPS-induced acute lung injury in mice, and markedly reduced the levels of multiple inflammatory factors. Collectively, an optimized fluorometric cell-based assay was devised for in situ functional imaging of CYP1A1 activities in living systems, which strongly facilitated the discovery of efficacious modulators of the AhR-CYP1A1 axis as novel anti-inflammatory agents.
10.NO-releasing double-crosslinked responsive hydrogels accelerate the treatment and repair of ischemic stroke.
Wen GUO ; Cheng HU ; Yue WANG ; Wen ZHANG ; Shaomin ZHANG ; Jin PENG ; Yunbing WANG ; Jinhui WU
Acta Pharmaceutica Sinica B 2025;15(2):1112-1125
Stroke is a global disease that seriously threatens human life. The pathological mechanisms of ischemic stroke include neuroinflammation, oxidative stress, and the destruction of blood vessels at the lesion site. Here, a biocompatible in situ hydrogel platform was designed to target multiple pathogenic mechanisms post-stroke, including anti-inflammation, anti-oxidant, and promotion of angiogenesis. Double-crosslinked responsive multifunctional hydrogels could quickly respond to the pathological microenvironment of the ischemic damage site and mediate the delivery of nitric oxide (NO) and ISO-1 (inhibitor of macrophage migration inhibitory factor, MIF). The hydrogel demonstrated good biocompatibility and could scavenge reactive oxygen species (ROS) and inflammatory cytokines, such as interleukin-6 (IL-6), interleukin-10 (IL-10), and MIF. In a mouse stroke model, hydrogels, when situated within the microenvironment of cerebral infarction characterized by weak acidity and elevated ROS release, would release anti-inflammatory nanoparticles rapidly that exert an anti-inflammatory effect. Concurrently, NO was sustained release to facilitate angiogenesis and provide neuroprotective effects. Neurological function was significantly improved in treated mice as assessed by the modified neurological severity score, rotarod test, and open field test. These findings indicate that the designed hydrogel held promise for sustained delivery of NO and ISO-1 to alleviate cerebral ischemic injury by responding to the brain's pathological microenvironment.

Result Analysis
Print
Save
E-mail