1.Research Progress on Inflammaging in Aplastic Anemia
Ke CHEN ; Xiangdong YANG ; Qianqian YANG ; Yu QIU ; Zipei ZHAO ; Guoqing LI ; Yuxiao CAO ; Caixia LIU
Acta Medicinae Universitatis Scientiae et Technologiae Huazhong 2026;55(2):302-307
As the global population ages at an accelerating pace,the burden of age-related hematological diseases is increasing.Inflammaging,a chronic,systemic,low-grade inflammatory state associated with aging,has been linked to various age-related diseases,including cardiovascular,cerebrovascular,and neurodegenerative disorders.However,its specific mechanistic role in aplastic anemia(AA)—a bone marrow failure—remains systematically unelucidated.This review comprehensively summarizes inflammaging and its underlying mechanisms,with a particular focus on its role in AA.We aim to elucidate how AA contributes to inflammaging in patients through a bone marrow microenvironment-hematopoietic stem cells-immune system triad network,thereby providing a rationale for future AA prevention and treatment.
2.Evaluation of Muscle Fatigue in Spinal Surgery Instruments Based on sEMG-JASA.
Yuxiao HOU ; Ningbo MAO ; Gengyu CAO ; Li WANG ; Yu ZHANG ; Yu ZHAO
Chinese Journal of Medical Instrumentation 2023;47(3):252-257
Based on the joint analysis of EMG spectrum and amplitude method (JASA), a study on muscle fatigue assessment of spinal surgical instruments based on surface EMG signals was carried out, and a comparative evaluation of the operating comfort before and after the optimization of spinal surgical instruments was completed. A total of 17 subjects were recruited to collect the surface EMG signals of their brachioradialis and biceps. Five surgical instruments before and after optimization were selected for data comparison, and the operating fatigue time proportion of each group of instruments under the same task was calculated based on the RMS and MF eigenvalues. The results showed that when completing the same operation task, the operation fatigue time of the surgical instruments before optimization was significantly higher than that after optimization (P<0.05); there was no significant difference in the fatigue status of brachioradialis and biceps when operating the same instrument (P>0.05). These results provide objective data and reference for the ergonomic design of surgical instruments and fatigue damage protection.
Humans
;
Muscle Fatigue/physiology*
;
Muscle, Skeletal
;
Electromyography
;
Ergonomics
3.Biological evaluation of three-dimensional printed co-poly lactic acid/glycolic acid/tri-calcium phosphate scaffold for bone reconstruction
Shuyi LI ; Miao ZHOU ; Yuxiao LAI ; Yuanming GENG ; Shuaishuai CAO ; Xiaoming CHEN
Chinese Journal of Stomatology 2016;51(11):661-666
Objective To biologically evaluate the three-dimensional(3D) printed co-poly lactic acid/glycolic acid/tri-calcium phosphate(PLGA/TCP) scaffold which could be used for repairing oral and maxillofacial bone defects,and to provide experimental evidence for its further research and clinical application.Methods PLGA/TCP scaffolds were fabricated using low temperature rapid prototyping technique.Micro-CT and scanning electron microscope(SEM) were used to characterize the surface morphology.MC3T3-E1 cells were seeded onto the scaffold and stained with the rhodamine phalloidin and calcein acetomethoxy.After that,confocal laser scanning microscope was exploited to observe the features and viability of the cells.Moreover,the cells were co-cultured with the extract of PLGA/TCP and complete medium,respectively.The proliferation capability of the cells was assessed by the cell counting kit-8 (CCK-8) on the 1st,2nd,and 3rd day.The PLGA/TCP scaffolds incorporated with recombinant human bone morphogenetic protein-2(rhBMP-2) of 0,30,60 μg(i.e.blank control group,low-dose group and high-dose group) were implanted into the latissimus dorsi muscle of the rats,and 6 weeks later,the samples were harvested to estimate the volume and pattern of new bone.Results The 3D printed PLGA/TCP scaffold possessed a regular and well-defined porous stereo-structure with porosity of (73±3)%.Micro-CT and SEM showed that pore size were (379±32) and (453t29) μm respectively,and distance between layers were (452± 24) and (415±25) μm,and cylinder diameter were (342±24) and (350±28) μm.It also exhibited excellent cell adhesion and growth ability on the exterior and inner surface through rhodamine phalloidin and calcein acetomethoxy staining.The CCK-8 test demonstrated that the absorbance value of extract group on the 1st and 2nd day(0.51 ±0.08 and 0.63±0.09) were significantly higher than those in the blank control group(0.39± 0.05 and 0.53±0.05)(P<0.05),while there was no significant difference between the extract group(0.67±0.06)and the blank control group(0.68±0.04)(P>0.05) on the 3rd day.For in vivo test,there was obvious ectopic new bone formation on the PLGA/rcP scaffold incorporated with rhBMP-2,and this was demonstrated using the histological examination and micro-CT.The bone formation in the low-dose group was similar to the shape of the pre-implanted 3D printed scaffold,while much diversity was revealed in the high-dose group duo to over osteogenesis which was validated by the examinations of gross observation,histology and micro-CT.Conclusions Customized PLGA/TCP scaffolds can be manufactured by 3D printing technique.The scaffold showed an excellent biocompatibility and ectopic osteogenesis when incorporated with rhBMP-2.However,further research is needed to validate it's effect on repairment of the oral and maxillofacial bone defects.


Result Analysis
Print
Save
E-mail