1.Causal relationship between intestinal flora and esophageal cancer: A Mendelian randomization analysis
Mengmeng WANG ; Mingjun GAO ; Siding ZHOU ; Shuyu TIAN ; Yusheng SHU ; Xiaolin WANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(03):397-405
Objective To explore whether there is a causal relationship between intestinal flora and esophageal cancer. Methods Summary statistics of intestinal flora and esophageal cancer were obtained from the Genome-wide Association Studies (GWAS) database. Five methods, including inverse variance weighted (IVW), weighted median estimation, Mendelian randomization (MR)-Egger regression, single mode, and weighted mode, were used for analysis, with IVW as the main analysis method. Sensitivity analysis was used to evaluate the reliability of MR results. Results In the IVW method, Oxalobacteraceae [OR=1.001, 95%CI (1.000, 1.002), P=0.023], Faecalibacterium [OR=1.001, 95%CI (1.000, 1.002), P=0.028], Senegalimassilia [OR=1.002, 95%CI (1.000, 1.003), P=0.006] and Veillonella [OR=1.001, 95%CI (1.000, 1.002), P=0.018] were positively correlated with esophageal cancer, while Burkholderiales [OR=0.999, 95%CI (0.998, 1.000), P=0.002], Eubacterium oxidoreducens [OR=0.998, 95%CI (0.997, 0.999), P=0.038], Romboutsia [OR=0.999, 95%CI (0.998, 1.000), P=0.048] and Turicibacter [OR=0.998, 95%CI (0.997, 0.999), P=0.013] were negatively correlated with esophageal cancer. Sensitivity analysis showed no evidence of heterogeneity, horizontal pleiotropy and reverse causality. Conclusion Oxalobacteraceae, Faecalibacterium, Senegalimassilia and Veillonella increase the risk of esophageal cancer, while Burkholderiales, Eubacterium oxidoreducens, Romboutsia and Turicibacter decrease the risk of esophageal cancer. Further studies are needed to explore how these bacteria affect the progression of esophageal cancer.
2.Shift work and workplace violence on healthcare workers' physical and mental health: The mediating role of job burnout
Zheng ZHANG ; Huijie XU ; Yusheng TIAN ; Jiansong ZHOU
Journal of Environmental and Occupational Medicine 2025;42(4):436-443
Background With the continuous development of the healthcare industry, healthcare workers face increasing pressure, including long-term shift work and workplace violence from patients or their relatives. This not only affects the physical and mental health of healthcare workers but may also negatively impact the quality of patient care and the efficiency of medical services. Objectives To analyze the pathways through which shift work and workplace violence affect healthcare workers' self-rated health and depression symptoms, explore potential mediating role of job burnout, and conduct subgroup analyses to reveal differences among various groups. Methods Data were collected from
3.Technical factors influencing non-surgical embryo transfer in mice
Xiaojing LIU ; Xiaoxin LIU ; Tiancun ZHANG ; Yonglu TIAN ; Xiaying LI ; Yusheng WEI
Chinese Journal of Comparative Medicine 2025;35(4):88-96
Objective We aimed to investigate the effects of different non-surgical embryo transfer devices,number of transferred embryos,embryo stage,and embryos obtained from different mouse strains on the efficiency of non-surgical embryo transfer in mice,and to compare the efficiencies of surgical and non-surgical embryo transfer,in order to establish a stable non-surgical embryo transfer technology system.Methods Mouse embryo transfer was carried out using non-surgical method.Results The pregnancy rates using two different non-surgical transfer devices were(75.00±0.00)%and(66.67±14.43)%,and the birth rates were(46.11±6.31)%and(18.89±0.96)%,respectively.Transfer of 10,15,and 20 embryos resulted in pregnancy rates of(66.67±11.55)%,(80.00±0.00)%,and(66.67±23.09)%,and birth rates of(29.33±4.16)%,(38.67±4.81)%,and(17.00±3.46)%,respectively.When blastocysts and morulae were transferred non-surgically,the resulting pregnancy rates were(80.00±0.00)%and(46.67±11.55)%and the birth rates were(38.67±4.81)%and(10.22±2.77)%,respectively.Four strains(C57BL/6J,ICR,genetically modified mice A,genetically modified mice B)were used as donors for non-surgical embryo transfer,with resulting pregnancy rates of(66.67±11.55)%,(80.00±0.00)%,(73.33±11.55)%,and(80.00±0.00)%,and birthrates of(26.67±2.67)%,(38.67±4.81)%,(32.00±3.53)%,and(29.34±2.31)%,respectively.Fifteen pseudo-pregnant mice were transplanted surgically and 15 were transplanted non-surgically,with pregnancy rates of(80.00±0.00)%and(86.67±11.55)%,and birth rates of(38.67±4.81)%and(36.00±5.82)%,respectively.Conclusions Transfer device A resulted in a higher birth rate in this study.The embryo transfer efficiency was higher when 15 embryos were transferred into unilateral uterine horns of pseudo-pregnant 2.5-day recipients.Blastocyst-stage embryo transfer was more efficient than morula-stage transfer.There was no significant difference in efficiency between surgical and non-surgical embryo transfer procedures.
4.Key aspects for the ethical review of laboratory animal welfare protocols
Xiaying LI ; Yonglu TIAN ; Yusheng WEI ; Wanyong PANG
Acta Laboratorium Animalis Scientia Sinica 2025;33(4):616-622
As an important and fundamental resource of scientific research,laboratory animals have become essential tools for the continuous advancements in life sciences,medical research,drug development,and other fields.With the development of related laws and regulations,the welfare of laboratory animals is increasingly valued by the general public and international research communities alike.To ensure the welfare of laboratory animals,the ethical review and conduct of laboratory animal practitioners should be standardized,incorporating and adapting advanced international practices with those in China.This article primarily outlines the process for reviewing and approving animal use protocols,along with the standards for evaluation,with the aim of providing a reference for researchers writing animal use protocols and for International Animal Care and Use Committee members conducting ethical reviews of laboratory animal welfare.
5.Establishment of a digital PCR detection method for Staphylococcus aureus in laboratory animals using microdroplet technique
Yuyu LI ; Jiying YAO ; Yonglu TIAN ; Tiantian SUN ; Yusheng WEI ; Xiaying LI
Acta Laboratorium Animalis Scientia Sinica 2025;33(3):430-439
Objective To establish a rapid and accurate droplet digital PCR(ddPCR)detection method for detecting Staphylococcus aureus(SA)in laboratory animals and the environment.Methods Using the heat-stable nuclease gene(nuc)of SA as the target gene,a pair of specific primers and probes are designed within its conserved region.Optimize the reaction conditions,test the dynamic range,and evaluate the specificity and stability of the method.Using the same template,test reactions were performed with both ddPCR and real-time quantitative PCR(qPCR)method to assess the interchangeability between the two approaches.Finally,the method is applied to the detection of various clinical samples.Results The kinetic range of the established SA ddPCR method is 100~15 000 copies/μL,with a detection limit of 2.5 copies and a quantification limit of 10 copies;The specificity of this method was tested,and only SA showed positive droplets,while no positive droplets were found for other pathogens;After measuring three parallel samples,the standard deviation and relative standard deviation were calculated.It was found that within the dynamic detection interval of ddPCR,as the target copy number gradually decreased,the relative standard deviation showed an upward trend,but remained below 25%.This result indicates that the detection method has good stability.Conclusions The established ddPCR method for detecting SA has the advantages of high sensitivity,strong specificity,good stability,and good reproducibility.This method can be applied for the detection of SA in laboratory animals.
6.Establishment of a digital PCR detection method for Staphylococcus aureus in laboratory animals using microdroplet technique
Yuyu LI ; Jiying YAO ; Yonglu TIAN ; Tiantian SUN ; Yusheng WEI ; Xiaying LI
Acta Laboratorium Animalis Scientia Sinica 2025;33(3):430-439
Objective To establish a rapid and accurate droplet digital PCR(ddPCR)detection method for detecting Staphylococcus aureus(SA)in laboratory animals and the environment.Methods Using the heat-stable nuclease gene(nuc)of SA as the target gene,a pair of specific primers and probes are designed within its conserved region.Optimize the reaction conditions,test the dynamic range,and evaluate the specificity and stability of the method.Using the same template,test reactions were performed with both ddPCR and real-time quantitative PCR(qPCR)method to assess the interchangeability between the two approaches.Finally,the method is applied to the detection of various clinical samples.Results The kinetic range of the established SA ddPCR method is 100~15 000 copies/μL,with a detection limit of 2.5 copies and a quantification limit of 10 copies;The specificity of this method was tested,and only SA showed positive droplets,while no positive droplets were found for other pathogens;After measuring three parallel samples,the standard deviation and relative standard deviation were calculated.It was found that within the dynamic detection interval of ddPCR,as the target copy number gradually decreased,the relative standard deviation showed an upward trend,but remained below 25%.This result indicates that the detection method has good stability.Conclusions The established ddPCR method for detecting SA has the advantages of high sensitivity,strong specificity,good stability,and good reproducibility.This method can be applied for the detection of SA in laboratory animals.
7.Technical factors influencing non-surgical embryo transfer in mice
Xiaojing LIU ; Xiaoxin LIU ; Tiancun ZHANG ; Yonglu TIAN ; Xiaying LI ; Yusheng WEI
Chinese Journal of Comparative Medicine 2025;35(4):88-96
Objective We aimed to investigate the effects of different non-surgical embryo transfer devices,number of transferred embryos,embryo stage,and embryos obtained from different mouse strains on the efficiency of non-surgical embryo transfer in mice,and to compare the efficiencies of surgical and non-surgical embryo transfer,in order to establish a stable non-surgical embryo transfer technology system.Methods Mouse embryo transfer was carried out using non-surgical method.Results The pregnancy rates using two different non-surgical transfer devices were(75.00±0.00)%and(66.67±14.43)%,and the birth rates were(46.11±6.31)%and(18.89±0.96)%,respectively.Transfer of 10,15,and 20 embryos resulted in pregnancy rates of(66.67±11.55)%,(80.00±0.00)%,and(66.67±23.09)%,and birth rates of(29.33±4.16)%,(38.67±4.81)%,and(17.00±3.46)%,respectively.When blastocysts and morulae were transferred non-surgically,the resulting pregnancy rates were(80.00±0.00)%and(46.67±11.55)%and the birth rates were(38.67±4.81)%and(10.22±2.77)%,respectively.Four strains(C57BL/6J,ICR,genetically modified mice A,genetically modified mice B)were used as donors for non-surgical embryo transfer,with resulting pregnancy rates of(66.67±11.55)%,(80.00±0.00)%,(73.33±11.55)%,and(80.00±0.00)%,and birthrates of(26.67±2.67)%,(38.67±4.81)%,(32.00±3.53)%,and(29.34±2.31)%,respectively.Fifteen pseudo-pregnant mice were transplanted surgically and 15 were transplanted non-surgically,with pregnancy rates of(80.00±0.00)%and(86.67±11.55)%,and birth rates of(38.67±4.81)%and(36.00±5.82)%,respectively.Conclusions Transfer device A resulted in a higher birth rate in this study.The embryo transfer efficiency was higher when 15 embryos were transferred into unilateral uterine horns of pseudo-pregnant 2.5-day recipients.Blastocyst-stage embryo transfer was more efficient than morula-stage transfer.There was no significant difference in efficiency between surgical and non-surgical embryo transfer procedures.
8.Key aspects for the ethical review of laboratory animal welfare protocols
Xiaying LI ; Yonglu TIAN ; Yusheng WEI ; Wanyong PANG
Acta Laboratorium Animalis Scientia Sinica 2025;33(4):616-622
As an important and fundamental resource of scientific research,laboratory animals have become essential tools for the continuous advancements in life sciences,medical research,drug development,and other fields.With the development of related laws and regulations,the welfare of laboratory animals is increasingly valued by the general public and international research communities alike.To ensure the welfare of laboratory animals,the ethical review and conduct of laboratory animal practitioners should be standardized,incorporating and adapting advanced international practices with those in China.This article primarily outlines the process for reviewing and approving animal use protocols,along with the standards for evaluation,with the aim of providing a reference for researchers writing animal use protocols and for International Animal Care and Use Committee members conducting ethical reviews of laboratory animal welfare.
9.Timing of stage Ⅱ vitrectomy in patients with open ocular trauma
Chunxia* MA ; Xiaxia* YANG ; Chaowei TIAN ; Manhong LI ; Dan HU ; Yusheng WANG ; Zifeng ZHANG
International Eye Science 2024;24(4):630-633
AIM:To observe the clinical efficacy of vitrectomy at different times for open ocular trauma and explore the timing of stage Ⅱ vitrectomy.METHODS: Retrospective case series study. A total of 60 cases(60 eyes)with open ocular trauma who visited our ophthalmology department from June 2022 to February 2023 were included. They were divided into treatment group A(interval ≤14 d)and treatment group B(interval >14 d)based on the interval between the stage Ⅰ emergency treatment surgery and the stage Ⅱ vitreoretinal surgery. Among the 32 cases(32 eyes)in the treatment group A, 16 eyes(50%)had eyeball rupture, 13 eyes(41%)had penetrating injury, and 3 eyes(9%)had perforating injury. Among the 28 cases(28 eyes)in the treatment group B, 15 eyes(54%)had eyeball rupture, 12 eyes(43%)had penetrating injury, and one eye(4%)had perforating injury. The two groups of patients were followed-up for 6 mo after surgery, and the treatment effects were compared.RESULTS:There was no statistically significant difference in visual acuity between the two groups of patients before vitrectomy(P>0.05). In the treatment group A, 10 eyes(31%)had significantly improved visual acuity, 21 eyes(66%)had effectively enhanced visual acuity, and 1 eye(3%)had no improvement in visual acuity at 6 mo after surgery. Among the 28 eyes in the treatment group B, 5 eyes(18%)had significantly improved vision, 16 eyes(57%)had effectively enhanced vision, and 7 eyes(25%)had no change in vision, with statistically significant difference between the two groups(U=322.5, P=0.032). There was no significant difference between the treatment group A and the treatment group B in complications such as secondary glaucoma, silicone oil dependence, vitreous hemorrhage, and eyeball atrophy(P>0.05). There was no evidence of traumatic proliferative vitreoretinopathy(TPVR)in the treatment group A during postoperative follow-up, which was significantly lower than that of the treatment group B(P<0.05).CONCLUSION:The prognosis of the stage Ⅱ vitrectomy for open ocular injury is relatively good after completing the stage Ⅰ surgery within 2 wk.
10.Refractive prediction error in vitrectomy combined with phacoemulsification and intraocular lens implantation for patients with macular disease and cata-ract
Jiayi KONG ; Zifeng ZHANG ; Manhong LI ; Chaowei TIAN ; Yusheng WANG
Recent Advances in Ophthalmology 2024;44(5):370-375
Objective To analyze the refractive prediction error(PE)in combined vitrectomy,phacoemulsification,and intraocular lens(IOL)implantation for patients with macular disease and cataract.Methods This study encom-passed 96 patients(96 eyes)diagnosed with macular disease and cataract,who underwent combined vitrectomy,phacoe-mulsification and IOL implantation at the Department of Ophthalmology in Xijing Hospital,Air Force Military Medical Uni-versity from May 2014 to November 2022.The best corrected visual acuity(BCVA)and actual spherical equivalent(SE)were studied,PE and absolute refractive error(ARE)were calculated,and the correlations between PE and axial length(AL),anterior chamber depth(ACD),lens thickness(LT),flat keratometry(Kf),steep keratometry(Ks),mean kera-tometry(Km),corneal astigmatism degree(cylinder,Cyl),intraocular pressure(IOP),BCVA,corneal astigmatism axis,the classification of macular diseases,and the type of intraoperative vitreous fillers were analyzed.Results In the early postoperative period(within 3 days after surgery),no statistically significant disparity in BCVA was observed compared to preoperative data among the 96 patients studied(P>0.05).The ARE was determined to be(1.47±2.54)D,indicating a substantial deviation between the actual SE and preoperative predictive refraction of the 96 patients(P<0.05).Among them,61 patients had a myopic shift,35 patients had a hyperopic shift,and the values of PE were(-1.81±3.07)D and(0.87±0.96)D,respectively.At the 1-month mark after surgery,there was no statistically significant difference in BCVA compared to the preoperative data of 12 follow-up patients(P>0.05).Similarly,no statistically significant differences were found between every two of the three data,namely the actual SE one month after surgery,the preoperative predictive refraction,and the actual SE in the early postoperative period of the 12 follow-up patients(all P>0.05).Also,no disparity was observed in BCVA at the last follow-up(P>0.05)among the 6 patients who were followed up for over 1 year(long-term postoperative follow-up).The correlation analysis revealed that,in the early postoperative period,the PE of patients with myopic shift was negatively correlated with both preoperative AL and Cyl measurements(both P<0.05).The early postoperative PE of patients with myopic shift was associated with the diagnostic classification of macular diseases(P<0.05),and the degree of myopic shift was observed to be significantly greater in patients with pathological myopia macular holes compared to those with other macular diseases(P<0.05).Additionally,the early postoperative PE of patients with myopic shift was uncorrelated with preoperative ACD,TL,Kf,Ks,Km,IOP,BCVA,the type of intraoperative vitreous fillers and the corneal astigmatism axis(all P>0.05).In contrast,for patients exhibiting hyperopic shift,the PE observed in the early postoperative period exhibited a positive correlation with preoperative Cyl(P<0.05).PE was also correlated with the type of intraoperative vitreous fillers(P<0.05),and the degree of hyperopic shift was notably enhanced when the intraoperative vitreous cavity was filled with silicone oil(P<0.05).The PE of patients with hyperopic shift observed in the early postoperative period exhibited no correlation with preoperative AL,ACD,TL,Kf,Ks,Km,IOP,BCVA,the diagnos-tic classification of macular diseases or the astigmatism axis(all P>0.05).Conclusion Refractive prediction error may occur in patients with macular disease and cataract in the initial postoperative period after the vitrectomy combined with phacoemulsification and IOL implantation,predominantly caused by myopic shift.However,over time,there is a signifi-cant reduction in the magnitude of this refractive error.The direction and extent of diopter drift appear to be influenced by preoperative AL,Cyl,the specific diagnosis of macular disease,and the type of vitreous cavity filler utilized in the surgical procedure.

Result Analysis
Print
Save
E-mail