1.Airborne bacterial profiling and air disinfection efficacy in small animal hospitals in South Korea
Dongryeoul BAE ; Yuseung KIM ; Kwang-Young SONG ; Jung-Hee KWON ; Jungwhan CHON
Journal of Veterinary Science 2026;27(1):e2-
Objective:
To evaluate the efficacy of a high-pressure spray disinfection system using neutral electrolyzed water to reduce airborne bacterial concentrations in veterinary hospitals and to characterize clinically relevant airborne pathogens and antimicrobial resistance.
Methods:
Active air sampling was performed before and after disinfection in multiple room types across five small animal hospitals in South Korea. Total airborne bacterial concentrations were quantified as colony-forming units per cubic meter. Representative colonies were identified by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, with confirmatory sequencing for selected isolates. Susceptibility testing was performed for Enterococcus faecium, Staphylococcus aureus, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, and Enterobacter species using disk diffusion.
Results:
Mean airborne bacterial concentrations decreased from 358.2 to 150.6 colony-forming units per cubic meter (58% reduction; p < 0.05). Waiting rooms showed the highest predisinfection concentrations, and operating rooms the lowest. Among 848 isolates, Micrococcus luteus, staphylococci, and Bacillus species were most frequent. Eight isolates were clinically important pathogens; two met multidrug resistance criteria. No targeted pathogens were detected after disinfection.
Conclusions
and Relevance: High-pressure neutral electrolyzed water spraying significantly reduced airborne bacterial loads in veterinary clinical environments, supporting routine air disinfection and microbial surveillance as components of infection prevention programs.
2.A prospective clinical study of immediate implant placement in the maxillary esthetic zone
Hee-seung HAN ; Sungtae KIM ; Hyunjae KIM ; Yuseung YI ; Young-Dan CHO
Journal of Periodontal & Implant Science 2025;55(5):397-407
Purpose:
Immediate implant placement (IIP) offers several advantages, including minimizing hard and soft tissue deformation, reducing implant time and cost, and rapidly restoring tooth function. However, IIP is technically challenging due to the need to secure initial stability and limit functional loading during healing. Therefore, this study aimed to evaluate the clinical outcomes of a bone-level implant featuring a dual thread design—an upper U-shaped thread and a lower V-shaped thread—with an 11° internal hexagonal connection in IIP within the maxillary esthetic zone.
Methods:
This study included 20 patients. Implants were inserted immediately after tooth extraction. Soft tissue changes were evaluated before tooth extraction (V0), after IIP (V1), at prosthesis delivery (V5), at a 3-month follow-up after prosthesis delivery (V6), and at a 1-year follow-up (V8). Bone dimensional changes were assessed at V1 and V8 using cone beam computed tomography, and the marginal bone level (MBL) was evaluated at V6 and V8 using 2-dimensional.
Results:
Of the 20 patients, 3 dropped out due to osseointegration failure during the followup period. Although the horizontal dimensions of the soft and hard tissues decreased slightly, the gingival margin and MBL remained well maintained throughout the follow-up.
Conclusions
Within this limited dataset, the lower V-shaped thread enabled favorable initial stability in IIP, and the esthetic outcomes were positive—with minimal gingival recession and marginal bone loss. Long-term follow-up is required to fully assess the impact of thread design and connection on esthetics.
3.Clinical performance of implant-assisted removable partial dentures using implant surveyed crowns: a systematic review and meta-analysis
So-Yeun KIM ; Young-Eun CHO ; Seoung-Jin HONG ; Jung-Bo HUH ; Se-Wook PYO ; Yuseung YI ; Soo-Yeon YOO
The Journal of Advanced Prosthodontics 2024;16(4):255-266
PURPOSE:
This study aimed to evaluate the clinical performance of implant-assisted removable partial dentures (IARPD) with surveyed crowns, also known as implant-crown-retained removable partial dentures (ICRPDs).
MATERIALS AND METHODS:
Electronic searches of MEDLINE/PubMed, the Cochrane Central Register of Controlled Trials, the Web of Science, and the Korea Citation Index were performed according to the established search terms for ICRPD. A literature search was conducted for studies published in English or Korean until September 2023, using the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guidelines.
RESULTS:
A total of 216 journals were searched, and 31 eligible studies were selected based on the inclusion and exclusion criteria. One systematic review included five case reports of ICRPD. Nine retrospective studies evaluated implant survival/success rate, implant failure cases, marginal bone loss, periodontal status, clinical complications, and patient satisfaction. Twenty-one case reports published in Korea showed good prognoses.
CONCLUSION
According to the findings of this systematic review, ICRPD has a reasonable survival/success rate, minimal bone loss, and high patient satisfaction.
4.A retrospective comparison of clinical outcomes of implant restorations for posterior edentulous area: 3-unit bridge supported by 2 implants vs 3 splinted implant-supported crowns
Yuseung YI ; Seong-Joo HEO ; Jai-Young KOAK ; Seong-Kyun KIM
The Journal of Advanced Prosthodontics 2022;14(4):223-235
PURPOSE:
. To compare the clinical outcomes of two types of implant restoration for posterior edentulous area, 3-unit bridge supported by 2 implants and 3 implant-supported splinted crowns.
MATERIALS AND METHODS:
. The data included 127 implant-supported fixed restorations in 85 patients: 37 restorations of 3-unit bridge supported by 2 implants (2-IB), 37 restorations of 3 implantsupported splinted crowns (3-IC), and 53 single restorations (S) as controls.Peri-implantitis and mechanical complications that occurred for 14 years were analyzed by multivariable Cox regression model. Kaplan-Meier curves and the multivariable Cox regression model were used to analyze the success and survival of implants.
RESULTS:
. Peri-implantitis occurred in 28.4% of 2-IB group, 37.8% of 3-IC group, and 28.3% of S control group with no significant difference. According to the implant position, middle implants (P2) of the 3-IC group had the highest risk of peri-implantitis. The 3-IC group showed a lower mechanical complication rate (7.2%) than the 2-IB (16.2%) and S control group (20.8%). The cumulative success rate was 52.8% in S (control) group, 62.2% in 2-IB group, and 60.4% in 3-IC group. The cumulative survival rate was 98.1% in S (control) group, 98.6% in 2-IB group, and 95.5% in 3-IC group. There was no significant difference in the success and survival rate according to the restoration type.
CONCLUSION
. The restoration type was not associated with the success and survival of implants. The risk of mechanical complications was reduced in 3 implant-supported splinted crowns. However, the middle implants of the 3 implant-supported splinted crowns had a higher risk of peri-implantitis.
5.Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force
Yuseung YI ; Seong Joo HEO ; Jai Young KOAK ; Seong Kyun KIM
The Journal of Advanced Prosthodontics 2019;11(6):305-312
PURPOSE: The purpose of this study was to compare computer-aided design/computer-aided manufacturing (CAD/CAM) abutment and prefabricated abutment in Morse taper internal connection type implants after cyclic loading.MATERIALS AND METHODS: The study was conducted with internal type implants of two different manufacturers (Group Os, De). Fourteen assemblies were prepared for each manufacturer group and divided into 2 groups (n=7): prefabricated abutments (Os-P, De-P) and CAD/CAM abutments (Os-C, De-C). The amount of axial displacement and the removal torque values (RTVs) were measured before and after cyclic loading (10⁶ cycles, 3 Hz with 150 N), and the tensile removal force to dislodge the abutments was measured after cyclic loading. A repeated measures ANOVA and a pattern analysis based on the logarithmic regression model were conducted to evaluate the effect of cyclic loading on the axial displacement. The Wilcoxon signed-rank test and the Mann-Whitney test was conducted for comparison of RTV reduction% and tensile removal forces.RESULTS: There was no significant difference between CAD/CAM abutments and prefabricated abutments in axial displacement and tensile removal force; however, significantly greater RTV reduction% after cyclic loading was observed in CAD/CAM abutments. The correlation among the axial displacement, the RTV, and the tensile removal force was not significant.CONCLUSION: The use of CAD/CAM abutment did not significantly affect the amount of axial displacement and tensile removal force, but presented a significantly greater removal torque reduction% than prefabricated abutments. The connection stability due to the friction at the abutment-implant interface of CAD/CAM abutments may not be different from prefabricated abutment.
Friction
;
Torque
6.Comparison of implant component fractures in external and internal type: A 12-year retrospective study
Yuseung YI ; Jai Young KOAK ; Seong Kyun KIM ; Shin Jae LEE ; Seong Joo HEO
The Journal of Advanced Prosthodontics 2018;10(2):155-162
PURPOSE: The aim of this study was to compare the fracture of implant component behavior of external and internal type of implants to suggest directions for successful implant treatment. MATERIALS AND METHODS: Data were collected from the clinical records of all patients who received WARANTEC implants at Seoul National University Dental Hospital from February 2002 to January 2014 for 12 years. Total number of implants was 1,289 and an average of 3.2 implants was installed per patient. Information about abutment connection type, implant locations, platform sizes was collected with presence of implant component fractures and their managements. SPSS statistics software (version 24.0, IBM) was used for the statistical analysis. RESULTS: Overall fracture was significantly more frequent in internal type. The most frequently fractured component was abutment in internal type implants, and screw fracture occurred most frequently in external type. Analyzing by fractured components, screw fracture was the most frequent in the maxillary anterior region and the most abutment fracture occurred in the maxillary posterior region and screw fractures occurred more frequently in NP (narrow platform) and abutment fractures occurred more frequently in RP (regular platform). CONCLUSION: In external type, screw fracture occurred most frequently, especially in the maxillary anterior region, and in internal type, abutment fracture occurred frequently in the posterior region. placement of an external type implant rather than an internal type is recommended for the posterior region where abutment fractures frequently occur.
Humans
;
Retrospective Studies
;
Seoul

Result Analysis
Print
Save
E-mail