1.Research on classification management model based on Karajek matrix for ECG monitoring equipment in emergency ICU
Xi TANG ; Ting ZENG ; Wangsheng DENG ; Yanhua DU ; Ao LIU ; Yuquan DENG ; Jinfeng MENG ; Xiaogui QI ; Lili WU ; Wanrong ZHU
China Medical Equipment 2025;22(2):132-137
Objective:To construct a classification management model on the basis of Kraljic matrix for electrocardiogram(ECG)monitoring equipment in emergency intensive care unit(ICU),so as to explore its application value in the management for ECG monitoring equipment in emergency ICU.Methods:The classification management model on the basis of index for ECG monitoring equipment in emergency ICU was constructed.According to two classification dimensions included the market supply risk and the self-value,an indicator system of classification management,which aimed at strategic materials with high value and high risk,leverage materials with high value and low risk,bottleneck materials with low value and high risk,and conventional materials with low value and low risk,was constructed.A total of fifty-one ECG monitoring equipment in the emergency ICU of The People's Hospital of Longhua of Shenzhen from January to December 2023 were selected,and they were managed respectively by conventional management mode(25 sets)and classification management mode(26 sets)according to different management modes.The standardization level of operation management for equipment,the occurrence of safety risk and the level of management for equipment of the two management modes were compared,and the satisfaction of 30 relative personnel,who used and managed these equipment,for classification management of equipment also were compared.Results:The average values of the percentage of standardization level of normality of equipment operation,disinfection and sterilization,maintenance and fault repair of using classification management mode were respectively(91.58±4.33)%,(92.1±3.28)%,(91.49±3.54)%and(92.58±3.32)%,all of which were higher than those of conventional management mode,and the differences were statistically significant(t=12.537,15.706,14.196,18.946,P<0.05),repsectively.The average incidences of the risk of pressure injury,electrical injury and body fluid extravasation of adopting classification management mode were respectively(2.54±0.87)%,(3.02±0.82)%and(1.29±0.65)%,all of which were lower than those of adopting conventional management mode,and the differences were statistically significant(t=22.825,17.453,24.424,P<0.05),respectively.The satisfaction scores of 30 relative management personnel,who used equipment on the process rationality,system standardization and quality effectiveness,of adopting classification management mode were respectively(94.26±3.54),(92.57±4.36)and(91.87±3.69),all of which were higher than those of conventional management mode,and the differences were statistically significant(t=14.052,13.991,13.551,P<0.05),respectively.The reasonable placement rate,recording rate of standardization,and intact rate of equipment in the 26 equipment by adopting classification management mode were respectively 92.31%,92.31%and 88.46%,all of which were significantly higher than those by adopting conventional management mode,and the differences were statistical significant(x2=12.052,10.398,11.338,P<0.05).Conclusion:The classification management model of ECG monitoring equipment in emergency ICU can increase the management efficiency for the equipment in operating room of hospital,and improve the operation quality of equipment,and enhance the safety of equipment in clinical use,and the standardization of operation management for equipment.
2.Research on classification management model based on Karajek matrix for ECG monitoring equipment in emergency ICU
Xi TANG ; Ting ZENG ; Wangsheng DENG ; Yanhua DU ; Ao LIU ; Yuquan DENG ; Jinfeng MENG ; Xiaogui QI ; Lili WU ; Wanrong ZHU
China Medical Equipment 2025;22(2):132-137
Objective:To construct a classification management model on the basis of Kraljic matrix for electrocardiogram(ECG)monitoring equipment in emergency intensive care unit(ICU),so as to explore its application value in the management for ECG monitoring equipment in emergency ICU.Methods:The classification management model on the basis of index for ECG monitoring equipment in emergency ICU was constructed.According to two classification dimensions included the market supply risk and the self-value,an indicator system of classification management,which aimed at strategic materials with high value and high risk,leverage materials with high value and low risk,bottleneck materials with low value and high risk,and conventional materials with low value and low risk,was constructed.A total of fifty-one ECG monitoring equipment in the emergency ICU of The People's Hospital of Longhua of Shenzhen from January to December 2023 were selected,and they were managed respectively by conventional management mode(25 sets)and classification management mode(26 sets)according to different management modes.The standardization level of operation management for equipment,the occurrence of safety risk and the level of management for equipment of the two management modes were compared,and the satisfaction of 30 relative personnel,who used and managed these equipment,for classification management of equipment also were compared.Results:The average values of the percentage of standardization level of normality of equipment operation,disinfection and sterilization,maintenance and fault repair of using classification management mode were respectively(91.58±4.33)%,(92.1±3.28)%,(91.49±3.54)%and(92.58±3.32)%,all of which were higher than those of conventional management mode,and the differences were statistically significant(t=12.537,15.706,14.196,18.946,P<0.05),repsectively.The average incidences of the risk of pressure injury,electrical injury and body fluid extravasation of adopting classification management mode were respectively(2.54±0.87)%,(3.02±0.82)%and(1.29±0.65)%,all of which were lower than those of adopting conventional management mode,and the differences were statistically significant(t=22.825,17.453,24.424,P<0.05),respectively.The satisfaction scores of 30 relative management personnel,who used equipment on the process rationality,system standardization and quality effectiveness,of adopting classification management mode were respectively(94.26±3.54),(92.57±4.36)and(91.87±3.69),all of which were higher than those of conventional management mode,and the differences were statistically significant(t=14.052,13.991,13.551,P<0.05),respectively.The reasonable placement rate,recording rate of standardization,and intact rate of equipment in the 26 equipment by adopting classification management mode were respectively 92.31%,92.31%and 88.46%,all of which were significantly higher than those by adopting conventional management mode,and the differences were statistical significant(x2=12.052,10.398,11.338,P<0.05).Conclusion:The classification management model of ECG monitoring equipment in emergency ICU can increase the management efficiency for the equipment in operating room of hospital,and improve the operation quality of equipment,and enhance the safety of equipment in clinical use,and the standardization of operation management for equipment.
3.Prokaryotic expression, purification, refolding and biological assays of recombinant human interleukin 4 inclusion body.
Jiong LI ; Kaijun CUI ; Jing WEN ; Zhiwei ZHAO ; Ping CHEN ; Ling TIAN ; Bing KAN ; Yanjun WEN ; Hongxin DENG ; Linyu FAN ; Yuquan WEI
Journal of Biomedical Engineering 2007;24(4):866-869
A DNA fragment encoding human interleukin 4 was obtained by PCR from pORF-hIL4 plasmid. The amplified fragment was inserted into prokaryotic expression vector PQE60 and recombinant protein was expressed in E. Coli M15 by adding isopropyl-beta-D-thiogalactoside (IPTG). The hIL-4 protein was present as insoluble inclusion bodies in the bacterial extract. After denaturation of inclusion bodies with 5 mol/L guanidine hydrochloride, the supernate was diluted to get renaturized. Then dialysis and Ni chelating chromatography were used for purification. TF-1 proliferation assay of recombinant human interleukin 4 was performed, and then rhIL-4 was fit to be used for proliferation of human dendritic cells from monocyte in vitro.
Escherichia coli
;
genetics
;
metabolism
;
Genetic Vectors
;
Humans
;
Inclusion Bodies
;
metabolism
;
Interleukin-4
;
biosynthesis
;
genetics
;
Protein Folding
;
Recombinant Proteins
;
biosynthesis
;
genetics
;
isolation & purification
4.Complete genome sequences of the SARS-CoV: the BJ Group (Isolates BJ01-BJ04).
Shengli BI ; E'de QIN ; Zuyuan XU ; Wei LI ; Jing WANG ; Yongwu HU ; Yong LIU ; Shumin DUAN ; Jianfei HU ; Yujun HAN ; Jing XU ; Yan LI ; Yao YI ; Yongdong ZHOU ; Wei LIN ; Hong XU ; Ruan LI ; Zizhang ZHANG ; Haiyan SUN ; Jingui ZHU ; Man YU ; Baochang FAN ; Qingfa WU ; Wei LIN ; Lin TANG ; Baoan YANG ; Guoqing LI ; Wenming PENG ; Wenjie LI ; Tao JIANG ; Yajun DENG ; Bohua LIU ; Jianping SHI ; Yongqiang DENG ; Wei WEI ; Hong LIU ; Zongzhong TONG ; Feng ZHANG ; Yu ZHANG ; Cui'e WANG ; Yuquan LI ; Jia YE ; Yonghua GAN ; Jia JI ; Xiaoyu LI ; Xiangjun TIAN ; Fushuang LU ; Gang TAN ; Ruifu YANG ; Bin LIU ; Siqi LIU ; Songgang LI ; Jun WANG ; Jian WANG ; Wuchun CAO ; Jun YU ; Xiaoping DONG ; Huanming YANG
Genomics, Proteomics & Bioinformatics 2003;1(3):180-192
Beijing has been one of the epicenters attacked most severely by the SARS-CoV (severe acute respiratory syndrome-associated coronavirus) since the first patient was diagnosed in one of the city's hospitals. We now report complete genome sequences of the BJ Group, including four isolates (Isolates BJ01, BJ02, BJ03, and BJ04) of the SARS-CoV. It is remarkable that all members of the BJ Group share a common haplotype, consisting of seven loci that differentiate the group from other isolates published to date. Among 42 substitutions uniquely identified from the BJ group, 32 are non-synonymous changes at the amino acid level. Rooted phylogenetic trees, proposed on the basis of haplotypes and other sequence variations of SARS-CoV isolates from Canada, USA, Singapore, and China, gave rise to different paradigms but positioned the BJ Group, together with the newly discovered GD01 (GD-Ins29) in the same clade, followed by the H-U Group (from Hong Kong to USA) and the H-T Group (from Hong Kong to Toronto), leaving the SP Group (Singapore) more distant. This result appears to suggest a possible transmission path from Guangdong to Beijing/Hong Kong, then to other countries and regions.
Genome, Viral
;
Haplotypes
;
Humans
;
Mutation
;
Open Reading Frames
;
Phylogeny
;
SARS Virus
;
genetics

Result Analysis
Print
Save
E-mail