1.Epidemiological characteristics and influencing factors of severe fever with thrombocytopenia syndrome in Zhejiang Province
LÜ ; Jing ; XU Xinying ; QIAO Yingyi ; SHI Xinglong ; YUE Fang ; LIU Ying ; CHENG Chuanlong ; ZHANG Yuqi ; SUN Jimin ; LI Xiujun
Journal of Preventive Medicine 2026;38(1):10-14
Objective:
To analyze the epidemiological characteristics and influencing factors of severe fever with thrombocytopenia syndrome (SFTS) in Zhejiang Province from 2019 to 2023, so as to provide the reference for strengthening SFTS prevention and control.
Methods:
Data on laboratory-confirmed SFTS cases in Zhejiang Province from 2019 to 2023 were collected through the Infectious Disease Reporting Information System of Chinese Disease Prevention and Control Information System. Meteorological data, geographic environment and socioeconomic factors during the same period were collected from the fifth-generation European Centre for Medium-Range Weather Forecasts, Geospatial Data Cloud, and Zhejiang Statistical Yearbook, respectively. Descriptive epidemiological methods were used to analyze the epidemiological characteristics of SFTS from 2019 to 2023, and a Bayesian spatio-temporal model was constructed to analyze the influencing factors of SFTS incidence.
Results:
A total of 578 SFTS cases were reported in Zhejiang Province from 2019 to 2023, with an annual average incidence of 0.23/105. The peak period was from May to July, accounting for 52.60%. There were 309 males and 269 females, with a male-to-female ratio of 1.15∶1. The cases were mainly aged 50-<80 years, farmers, and in rural areas, accounting for 82.53%, 77.34%, and 75.43%, respectively. Taizhou City and Shaoxing City reported more SFTS cases, while Shaoxing City and Zhoushan City had higher annual average incidences of SFTS. The Bayesian spatio-temporal interaction model showed good goodness of fit. The results showed that mean temperature (RR=1.626, 95%CI: 1.111-2.378) and mean wind speed (RR=1.814, 95%CI: 1.321-2.492) were positively correlated with SFTS risk, while altitude (RR=0.432, 95%CI: 0.230-0.829) and population density (RR=0.443, 95%CI: 0.207-0.964) were negatively correlated with SFTS risk.
Conclusions
SFTS in Zhejiang Province peaks from May to July. Middle-aged and elderly people and farmers are high-risk populations. Taizhou City, Shaoxing City, and Zhoushan City are high-incidence areas. Mean temperature, mean wind speed, altitude, and population density can all affect the risk of SFTS incidence.
2.Health risk assessment of employees in an enterprise involving lead, arsenic and cadmium
Yanru WANG ; Zhaohui ZHANG ; Yuqi TONG ; Yaqi LI
Journal of Public Health and Preventive Medicine 2026;37(3):66-70
Objective To investigate occupational exposure levels of lead, arsenic and cadmium in the lead smelting plant of Hunan Shui Kou Shan Nonferrous Metals Group Co. Ltd., analyze their effects on health of employees, and compare the applicability of different occupational health risk assessment methods, and to provide a basis for prevention and control of occupational exposure risks in enterprises. Methods According to systematic sampling method, 380 employees with lead, arsenic and cadmium exposure (exposure group) and 100 non-exposure employees (non-exposure group) were selected from 2022 to 2024 for on-site investigation of occupational health [concentration time-weighted average (CTWA)] and physical examination. The risk was evaluated by qualitative assessment method, the U.S. Environmental Protection Agency (EPA) inhalation risk assessment method, and the Singapore Ministry of Manpower (MOM) semi-quantitative method. The consistency was analyzed by the Kappa test. Results CTWA values of lead, arsenic, and cadmium in all positions were lower than the occupational exposure limit (OEL). The levels of blood lead, urine arsenic, and urine cadmium, as well as the prevalence of multiple systems in the exposure group were significantly higher than those in the non-exposure group (P<0.05). The proportions of chronic lead, arsenic, and cadmium poisoning were increasing year by year in the exposure group (P<0.05). The qualitative assessment method mainly indicated low and medium risk, while the EPA and MOM methods mainly indicated medium and high risk, with good agreement between the two methods (Kappa=0.676, P<0.05). Conclusion Although the enterprise meets the CTWA standards, there are still occupational health risks of lead, arsenic, and cadmium. The EPA inhalation risk assessment method is more applicable.
3.Analyses of comorbidity patterns of chronic metabolic diseases among residents aged 35‒75 years in Nantong City, Jiangsu Province
Yuqi WANG ; Jie HUANG ; Bo CAI ; Yarong HAN ; Ling LIN ; Xingxing FANG
Shanghai Journal of Preventive Medicine 2026;38(3):187-192
ObjectiveTo analyze the comorbidity patterns of chronic metabolic diseases and their influencing factors among residents aged 35‒75 years old in Nantong City of Jiangsu Province, and to provide theoretical support for the prevention and control of comorbidities. MethodsThe permanent residents aged 35‒75 years from the Comprehensive Prevention and Control Project of Cardiovascular and Cerebrovascular Diseases in Nantong City from 2021 to 2024 were selected as the research subjects. Clustering analysis and association rule were used to investigate the comorbidity patterns of chronic metabolic diseases, and their influencing factors were identified through logistic regression analyses. ResultsThe prevalence of comorbidity of chronic metabolic diseases among residents aged 35‒75 years in Nantong City was 47.40%. Among comorbidity patterns based on disease counts, the prevalence of hypertension+dyslipidemia was highest in binary comorbidity patterns (6.25%), while that of hypertension+dyslipidemia+obesity was highest in ternary comorbidity patterns (4.01%). Association rules showed that in both binary and ternary comorbidity patterns, the confidence level was highest for obesity+hypertension (72.70%) and obesity+dyslipidemia+hypertension (74.54%). Renal insufficiency formed an independent cluster in cluster analyses. Logistic regression analyses revealed that, compared with the non-comorbidity group, males (OR=2.22, 95%CI: 1.69‒2.91), advanced age (45‒54 years, OR=1.38, 95%CI: 1.02‒1.88; 55‒64 years, OR=1.59, 95%CI: 1.14‒2.23; 65‒75 years, OR=2.34, 95%CI: 1.58‒3.47), and low physical activity (OR=1.26, 95%CI: 1.10‒1.65) were influencing factors for metabolic disease comorbidity. ConclusionIn the comorbidity patterns of chronic metabolic diseases among residents aged 35‒75 years in Nantong City, hypertension, diabetes mellitus, and dyslipidemia interact with each other. Individuals with obesity are more prone to diseases such as hypertension and dyslipidemia. Prevention and control of chronic metabolic diseases should be strengthened for males, individuals with low physical activity and advanced age.
4.Smart traditional Chinese medicine empowers the whole chain of “prevention–screening–diagnosis–treatment–management” for major chronic diseases in primary healthcare: Research on cardiovascular–cerebrovascular diseases and tumors
Xiaoyu ZHANG ; Jianlin WEI ; Yuqi LIANG ; Liangzhen YOU ; Mei ZHANG ; Hongcai SHANG
Science of Traditional Chinese Medicine 2026;4(2):132-139
Driven by policy initiatives promoting the integration of digital-intelligent technologies with primary healthcare and the digital transformation of traditional Chinese medicine (TCM), Smart TCM has emerged as a pivotal strategy for enhancing primary healthcare services for major chronic diseases. This paper reviews the current status, challenges, and feasible pathways of Smart TCM in community-level management of cardiovascular–cerebrovascular diseases and tumors, which represent major chronic disease burdens. Our findings indicate that Smart TCM demonstrates emerging potential in primary healthcare for chronic diseases across the entire continuum of “prevention-screening-diagnosis-treatment-management.” However, several significant challenges persist, including data silos and security vulnerabilities, limited applicability of existing models to real-world clinical needs, and insufficient digital literacy among primary healthcare physicians and elderly patients. To address these constraints, this paper proposes a multidimensional strategy encompassing the development of secure and interoperable regional data platforms, lightweight intelligent devices and support services aligned with primary care capacity, unified technical and data standards with corresponding quality control systems, adaptive and dynamically updated artificial intelligent models, interdisciplinary workforce training and patient education programs, and enhanced policy and health insurance support. Overall, Smart TCM shows great promise for improving the efficiency of primary healthcare delivery and establishing innovative TCM-based chronic disease management paradigms.
5.Effects of Electro-Acupuncture Based on the Midnight-Noon Ebb-Low Method with Hour-Prescription on BMAL1 Protein and NETs Markers in Lung Tissue of Chronic Obstructive Pulmonary Disease Model Rats with Lung-Qi Deficiency Syndrome
Changtian JIAO-LI ; Nise Pantaleo SHIO ; Lianqing CAI ; Qingyao JIANG ; Siyu TANG ; Qianqian WAN ; Mengchen WAN ; Yuqi YE ; Jie ZHU
Journal of Traditional Chinese Medicine 2026;67(13):1422-1430
ObjectiveTo explore the potential mechanism underlying electroacupuncture therapy with the midnight-noon ebb-low method with hour-prescription for chronic obstructive pulmonary disease (COPD) with lung-qi deficiency syndrome from the perspective of brain and muscle basic helix-loop-helix ARNT-like 1 (BMAL1) as well as neutrophil extracellular traps (NETs). MethodsThe experiment was conducted in two phases. For the therapeutic effectiveness observation, 24 rats were randomly allocated into control group 1, model group 1, midnight-noon electro-acupuncture group 1 and conventional electro-acupuncture group, with 6 rats per group. Rat models of COPD with lung-qi deficiency syndrome were established via cigarette smoke exposure combined with intratracheal instillation of lipopolysaccharide (LPS). After successful modelling, rats in midnight-noon electro-acupuncture group 1 received electro-acupuncture at acupoints "Taiyuan (LU 9)", "Feishu (BL 13)" and "Zusanli (ST 36)" during 05:00—07:00, 30 minutes per treatment once every other day for 14 consecutive days (7 sessions in total). Rats in the conventional electro-acupuncture group received identical electroacupuncture manipulation at random daytime hours (08:00—18:00). Pulmonary function parameters including forced expiratory volume in 0.3 second (FEV0.3), forced vital capacity (FVC) and FEV0.3/FVC ratio were detected. Pulmonary histopathological changes were observed via hematoxylin-eosin (HE) staining. Plasma levels of pro-inflammatory factors interleukin-1β (IL-1β) and tumor necrosis factor-α (TNF-α), as well as pulmonary reactive oxygen species (ROS) content, BMAL1 protein expression and the levels of neutrophil extracellular traps (NETs) biomarkers such as myeloperoxidase (MPO), neutrophil elastase (NE), and citrullinated histone H3 (CitH3) in lung tissue were determined. For the mechanistic verification phase, 36 rats were divided into control group 2, model group 2, midnight-noon electro-acupuncture group 2, overexpression empty group, overexpression BMAL1 group and overexpression with midnight-noon electro-acupuncture group, with 6 rats in each group. At the 5th week of model construction, rats in the overexpression BMAL1 group and overexpression with midnight-noon electro-acupuncture group received intratracheal instillation of 100 μl adenoviral suspension carrying overexpressed Bmal1 gene. Rats in the overexpression empty group were injected with an equal titer and equal volume of blank adenovirus without the Bmal1 coding sequence into the lung at the identical time point. Midnight-noon electro-acupuncture group 2 and overexpression with midnight-noon electro-acupuncture group were consistent with the aforementioned protocol. Finally, pulmonary levels of MPO, NE and CitH3 were measured in all groups. ResultsCompared with the control group 1, the model group 1 exhibited decreased FEV0.3, FVC and FEV0.3/FVC ratio, elevated plasma IL-1β, TNF-α and pulmonary ROS levels, downregulated lung BMAL1 protein expression, and increased contents of MPO, NE and CitH3 (all P<0.05); typical NETs-like structures with sparse granular substances attached to fibrous networks were observed under scanning electron microscopy; HE staining revealed damaged alveolar architecture accompanied by inflammatory cell infiltration. Compared with model group 1, both the midnight-noon electro-acupuncture group 1 and conventional electro-acupuncture group achieved obvious improvements in all above indicators, with superior therapeutic effects in midnight-noon electro-acupuncture group 1 (P<0.05). Consistently, midnight-noon electro-acupuncture group 1 showed more prominent alleviation of NETs-like structure formation and lung pathological injury compared to the conventional electro-acupuncture group. Mechanistic validation results demonstrated that compared with model group 2, the average optical density of MPO as well as the protein levels of MPO, NE and CitH3 were markedly reduced in midnight-noon electro-acupuncture group 2, overexpression BMAL1 group and overexpression with midnight-noon electro-acupuncture group (P<0.05); furthermore, these parameters were significantly lower in the overexpression with midnight-noon electro-acupuncture group than in midnight-noon electro-acupuncture group 2 (P<0.05). ConclusionElectro-acupuncture based on the midnight-noon ebb-low method with hour-prescription may alleviate pulmonary inflammation in COPD by upregulating the expression of clock protein BMAL1 and inhibiting excessive accumulation of NETs in lung tissue.
6.Screening and quantitative analysis of Q-Marker for anti-renal fibrosis of Shenqi shenshuai mixture based on untargeted metabolomics and bioinformatics
Yuhang ZHOU ; Yuqi LI ; Zhuo GAO ; Qingfeng RUAN ; Xiaoxuan ZENG ; Hui WANG ; Chuanqi HUANG ; Hongfeng XU
China Pharmacy 2026;37(13):1716-1721
OBJECTIVE To screen and quantitatively analyze the quality marker (Q-Marker) associated with anti-renal fibrosis in Shenqi shenshuai mixture (SQSS), so as to provide references for the analysis of pharmacodynamic substances and new drug transformation of SQSS. METHODS The chemical components of SQSS were characterized by untargeted metabolomics. Combined with network pharmacology, gene expression omnibus (GEO) and connectivity map (CMAP) databases, the anti-renal fibrosis Q-Markers of SQSS were screened. HPLC-MS/MS was applied to determine the contents of Q-Markers in 10 batches of SQSS. RESULTS A total of 1 319 compounds were identified from SQSS via untargeted metabolomics,and 84 active ingredients with anti-renal fibrosis activity were further screened out, such as formononetin. Nine anti-renal fibrosis Q-Markers were obtained by network pharmacology and GEO database, including berberine, quercetin, honokiol, nicotinamide, daidzein, coumarin, kaempferol, formononetin and amygdalin. The quantitative results showed that the average contents of the above components (excluding amygdalin) in 10 batches of SQSS were 2.523, 1.942, 26.848, 1.415, 0.692, 0.171, 0.374, 7.401 μg/mL, respectively. CONCLUSIONS Nine anti-renal fibrosis Q-Markers of SQSS were screened in this study, and the contents of eight among them were determined. The results can provide a basis for elucidating the pharmacodynamic material basis and promoting the new drug transformation of SQSS.
7.Screening and quantitative analysis of Q-Marker for anti-renal fibrosis of Shenqi shenshuai mixture based on untargeted metabolomics and bioinformatics
Yuhang ZHOU ; Yuqi LI ; Zhuo GAO ; Qingfeng RUAN ; Xiaoxuan ZENG ; Hui WANG ; Chuanqi HUANG ; Hongfeng XU
China Pharmacy 2026;37(13):1716-1721
OBJECTIVE To screen and quantitatively analyze the quality marker (Q-Marker) associated with anti-renal fibrosis in Shenqi shenshuai mixture (SQSS), so as to provide references for the analysis of pharmacodynamic substances and new drug transformation of SQSS. METHODS The chemical components of SQSS were characterized by untargeted metabolomics. Combined with network pharmacology, gene expression omnibus (GEO) and connectivity map (CMAP) databases, the anti-renal fibrosis Q-Markers of SQSS were screened. HPLC-MS/MS was applied to determine the contents of Q-Markers in 10 batches of SQSS. RESULTS A total of 1 319 compounds were identified from SQSS via untargeted metabolomics,and 84 active ingredients with anti-renal fibrosis activity were further screened out, such as formononetin. Nine anti-renal fibrosis Q-Markers were obtained by network pharmacology and GEO database, including berberine, quercetin, honokiol, nicotinamide, daidzein, coumarin, kaempferol, formononetin and amygdalin. The quantitative results showed that the average contents of the above components (excluding amygdalin) in 10 batches of SQSS were 2.523, 1.942, 26.848, 1.415, 0.692, 0.171, 0.374, 7.401 μg/mL, respectively. CONCLUSIONS Nine anti-renal fibrosis Q-Markers of SQSS were screened in this study, and the contents of eight among them were determined. The results can provide a basis for elucidating the pharmacodynamic material basis and promoting the new drug transformation of SQSS.
8.Analysis of the results from the 2024 national interlaboratory comparison for radionuclide measurement in bio-ash
Chunming ZHONG ; Xiang GAO ; Jin ZHANG ; Xin ZHANG ; Yuqi HUANG
Chinese Journal of Radiological Health 2026;35(3):331-335
Objective To enhance the gamma spectrometry analysis and detection capabilities of personnel in measuring radionuclides in bio-ash, and ensure the accuracy and precision of gamma spectrometer in our laboratory for the analysis of radionuclides in bio-ash. Methods The laboratory participated in the 2024 national interlaboratory comparison for radionuclide measurement in bio-ash. Radionuclides 241Am, 137Cs, and 40K in four different bio-ash samples were measured. Based on the measurement methods specified in GB/T 16145—2022, sample measurement, result calculation, and uncertainty evaluation were performed using spectrometry analysis software and sourceless efficiency calibration software. The measurement results and performance evaluation of the laboratory in the comparison were analyzed, and factors affecting gamma-spectrometry measurement and result interpretation were discussed. Results The relative deviation (D) of the measurement results for radionuclides 241Am and 137Cs in the four bio-ash samples ranged from −10.2% to 2.0% and −1.7% to 0.3%, respectively. The P statistic ranged from 7.0% to 12.5% and 5.0% to 10.8%, respectively. These results met the criteria of |D| ≤ 20% (MARB), |D| ≤ 2.58P, and P ≤ 20% (MARB). The ζ-scores for the measurement of 40K in the four bio-ash samples ranged from 0.8 to 1.3, satisfying the criterion of |ζ| < 2. All measurement results in this laboratory in the comparison were satisfactory. Conclusion The laboratory uses a high-purity germanium gamma spectrometer to measure radionuclides in bio-ash. The self-absorption correction method, analysis method, and uncertainty evaluation are appropriate, which can ensure the accuracy and precision of the measurement results. The measurement results are accurate and reliable.
9.Preliminary establishment of comprehensive risk assessment indicator system for occupational health based on Delphi method and analytic hierarchy process
Weiqi SUN ; Meixia LIU ; Tongning GAO ; Yuqi CHEN ; Yan YIN
Journal of Environmental and Occupational Medicine 2026;43(6):754-761
Background Occupational health risk assessment is the foundation of safeguarding workers' occupational health. However, traditional assessment methods often fail to adequately account for health effects and enterprise-specific characteristics, limiting their comprehensive evaluation capabilities. Additionally, these methods suffer from inconsistent standards, narrow application scopes, insufficient hazard sub-categorization, and indicator systems that poorly support informatization and digital transformation. To address these gaps, this study proposes methodological innovations focusing on the assessment indicator system. Objective To construct a systematic, generalizable, and practical occupational health comprehensive risk assessment indicator system by leveraging occupational health practices and surveillance big data from Shanghai. Methods Initial system indicators were extrated through literature review. Subsequently, expert interviews and group discussions, combined with occupational health surveillance big data, were used to refine these indicators, forming a candidate pool covering two major dimensions: risk factor characteristics and enterprise characteristics. The Delphi method was applied to evaluate and screen the indicators, while the analytic hierarchy process (AHP) was used to construct a hierarchical model and determine indicator weights. Results A total of 76 articles were reviewed, identifying 25 candidate indicators. After two rounds of Delphi expert consultation, 8 primary indicators (e.g. hazard characteristics, exposure characteristics, health effects, industry characteristics, management characteristics, protective features, adverse events, and uncertainty) and 17 secondary indicators (hazard factor characteristics, exposure levels, number of people exposed, number of factor exposure, special physical exam indicators, suspected occupational diseases, occupational diseases, industry categories, organizational management, hazard reporting, occupational health training, hazard factor testing, occupational health exams, protective facilities, personal protective equipment, administrative penalties, and data quality) were finalized. The expert response rate was 100%, and the expert authority coefficient was 0.86. The Kendall's W coefficients for importance and accessibility scores across the two consultation rounds were 0.41, 0.40 and 0.41, 0.50. A hierarchical model targeting the comprehensive occupational health risk index was constructed, comprising two major elements and three levels of indicators. AHP was applied to calculate the weights, with all judgment matrices demonstrating satisfactory consistency (consistency ratio < 0.1). Conclusion By integrating risk factor profiles with enterprise-specific characteristics via the Delphi-AHP approach, a robust occupational health comprehensive risk assessment indicator system is established. This system provides a practical framework for digitized occupational health management, though further empirical validation in real-world settings is warranted.
10.Status and influencing factors of the application of informatization tools for antimicrobial stewardship in Chinese county hospitals
Yuqi FU ; Xin LI ; Ying LI ; Hongwei WU ; Zhixin FAN ; Jinru LIU ; Xi CHEN ; Yuxiang XIA ; Qiang SUN ; Yingbo ZHAO
China Pharmacy 2026;37(16):2084-2089
OBJECTIVE To investigate the current status of informatization tools applied to antimicrobial stewardship in county hospitals in China, and to provide a reference for promoting the informatization development of antimicrobial stewardship in county hospitals.METHODS From August to September 2025, an online questionnaire survey was conducted among 1 007 county hospitals across 31 provinces(autonomous regions, and municipalities) in China. The survey focused on the application of four types of informatization tools:the real-time monitoring system for antimicrobial use, the pre-prescription review system, the irrational use warning system, and the electronic prescription evaluation system(hereinafter referred to as the “monitoring system”“review system”“warning system”“evaluation system”,respectively). Correlation analysis and binary Logistic regression analysis were employed to explore the influencing factors.RESULTS Of the county hospitals, 80.83% were equipped with at least one type of informatization tool for antimicrobial stewardship, while 19.17% had no relevant tool. Only 18.87% of the hospitals were equipped with all four types of tools. The monitoring system exhibited the highest equipped rate (70.80%), whereas the warning system was equipped in only 33.96% of the hospitals. Four types of tools are evenly and adequately deployed in the eastern region, the central and western regions have far lower deployment rates of intervention tools including review system and warning system, accompanied by prominent intra-provincial gaps. The total number of the health technicians, hospital grade, and prescription review rate of outpatient antibacterial drug were significantly and positively correlated with the deployment rates of the four informatization tools ( P <0.05). The results of the Logistic regression model fitting indicated that the model of the review system was rated “excellent” [area under the receiver operating characteristic curve (AUC)=0.81], and the model of the warning system was rated “further improvement” (AUC=0.67). The total number of health technicians was significantly positively correlated with the deployment rates of all four types of informatization tools (all P <0.05).CONCLUSIONS The informatization of antimicrobial stewardship in county hospitals in China remains in the initial stage of transitioning from “passive statistics” to “active prevention and control”, with challenges such as structural imbalance and regional disparities. In the future, differentiated support strategies should be implemented, the allocation of resources should be optimized, to enhance the level of refined antimicrobial stewardship.


Result Analysis
Print
Save
E-mail