1.Identification of core genes of osteoarthritis by bioinformatics
Xuekun ZHU ; Heng LIU ; Hui FENG ; Yunlong GAO ; Lei WEN ; Xiaosong CAI ; Ben ZHAO ; Min ZHONG
Chinese Journal of Tissue Engineering Research 2025;29(3):637-644
BACKGROUND:At present,osteoarthritis has become a major disease affecting the quality of life of the elderly,and the therapeutic effect is poor,often focusing on preventing the disease process,and the pathogenesis of osteoarthritis is still not fully understood.Bioinformatics analysis was carried out to explore the main pathogenesis of osteoarthritis and related mechanisms of gene coding regulation. OBJECTIVE:To screen core differential genes with a major role in osteoarthritis by gene expression profiling. METHODS:Datasets were downloaded from the Gene Expression Omnibus(GEO):GSE114007,GSE117999,and GSE129147.Differential genes in the GSE114007 and GSE117999 data collections were screened using R software,performing differential genes to weighted gene co-expression network analysis.The module genes most relevant to osteoarthritis were selected to perform protein interaction analysis.Candidate core genes were selected using the cytocape software.The candidate core genes were subsequently subjected to least absolute shrinkage and selection operator regression and COX analysis to identify the core genes with a key role in osteoarthritis.The accuracy of the core genes was validated using an external dataset,GSE129147. RESULTS AND CONCLUSION:(1)A total of 477 differential genes were identified,265 differential genes associated with osteoarthritis were obtained by weighted gene co-expression network analysis,and 8 candidate core genes were identified.The least absolute shrinkage and selection operator regression analysis finally yielded a differential gene ASPM with core value that was externally validated.(2)It is concluded that abnormal gene ASPM expression screened by bioinformatics plays a key central role in osteoarthritis.
2.A modified surgical technique of robot-assisted inferior vena cava thrombectomy for patients with left renal cell carcinoma and tumor emboli: a report of 7 cases eliminating preoperative interventional embolization
Shengzheng WANG ; Jinshan CUI ; Zhenhao LI ; Yunlong LIU ; Shuanbao YU ; Yafeng FAN ; Zhaowei ZHU ; Jin TAO ; Xuepei ZHANG
Journal of Modern Urology 2025;30(2):128-132
Objective: To explore the safety and feasibility of the disconnection of the left renal artery preferentially during robot-assisted inferior vena cava (IVC) thrombectomy for patients with left renal cell carcinoma and tumor emboli. Methods: Clinical data of 7 patients who underwent robot-assisted IVC thrombectomy and radical nephrectomy in the First Affiliated Hospital of Zhengzhou University during Dec.2021 and Oct.2024 were retrospectively analyzed.Thrombectomy was performed first,followed by nephrectomy. The “IVC-first, kidney-last”robotic technique was developed to minimize chances of IVC thrombus. When patients in left lateral decubitus position, the left renal artery was severed from the right side through the inferior vena cava and abdominal aorta. After removal of thrombus from IVC was completed, patients changed to the right lateral position to complete radical left nephrectomy. Results: Imaging examinations revealed that the median diameter of the renal cell carcinomas was 83(46-99) mm; the median length of the inferior vena cava cancerous emboli was 49(2-91) mm.According to the Mayo classification,the cancerous emboli were gradeⅠ in 2 cases,gradeⅡ in 4 cases,and grade Ⅲ in 1 case.All surgeries were successful.The median operation time was 248(201-331) minutes,blood loss 500(200-1000) mL,and 6 cases required intraoperative blood transfusion.The median time for transition into the intensive care unit was 1(1-4) days,and drainage tube removal 6(5-12) days.Serum creatinine increased significantly in 5 cases,4 of which returned to normal after 1 week,but 1 had renal insufficiency (creatinine 166 μmol/L).Chylous fistula occurred in 1 patient,and lower extremity venous thrombosis developed in 3 patients.Pathological examinations indicated 6 cases of renal cell carcinoma and 1 case of MiT family translocation renal cell carcinoma.During the median follow-up of 17(1-35) months,5 cases were tumor-free,while 2 had lung and retroperitoneal metastases.They received targeted therapy of axitinib combined immunotheraphy and lived with tumors. Conclusion: In the left lateral position for left renal cell carcinoma with cancerous emboli,robot-assisted laparoscopic thrombectomy by crossing the inferior vena cava and abdominal aorta and disconnecting the left renal artery first is safe and feasible.
3.Full-size diffusion model for adaptive feature medical image fusion.
Jing DI ; Shuhui SHI ; Heran WANG ; Chan LIANG ; Yunlong ZHU
Journal of Biomedical Engineering 2025;42(5):871-882
To address issues such as loss of detailed information, blurred target boundaries, and unclear structural hierarchy in medical image fusion, this paper proposes an adaptive feature medical image fusion network based on a full-scale diffusion model. First, a region-level feature map is generated using a kernel-based saliency map to enhance local features and boundary details. Then, a full-scale diffusion feature extraction network is employed for global feature extraction, alongside a multi-scale denoising U-shaped network designed to fully capture cross-layer information. A multi-scale feature integration module is introduced to reinforce texture details and structural information extracted by the encoder. Finally, an adaptive fusion scheme is applied to progressively fuse region-level features, global features, and source images layer by layer, enhancing the preservation of detail information. To validate the effectiveness of the proposed method, this paper validates the proposed model on the publicly available Harvard dataset and an abdominal dataset. By comparing with nine other representative image fusion methods, the proposed approach achieved improvements across seven evaluation metrics. The results demonstrate that the proposed method effectively extracts both global and local features of medical images, enhances texture details and target boundary clarity, and generates fusion image with high contrast and rich information, providing more reliable support for subsequent clinical diagnosis.
Humans
;
Image Processing, Computer-Assisted/methods*
;
Algorithms
;
Neural Networks, Computer
;
Diagnostic Imaging/methods*
;
Image Interpretation, Computer-Assisted/methods*
4.Perifornical UCN3 Neurons Regulate Overeating-Induced Weight Gain.
Shanshan LU ; Xinran ZHANG ; Wanqi CHEN ; Baofang ZHANG ; Haiyang JING ; Yunlong XU ; Fengling LI ; Chenyu JIANG ; Gaowei CHEN ; Xiaofei DENG ; Yingjie ZHU
Neuroscience Bulletin 2025;41(6):1103-1108
5.Emphasizing the innovation of urological robotic-assisted surgical instruments and technology driven by new quality productivity forces
Xuepei ZHANG ; Zhaowei ZHU ; Pin ZHAO ; Shuanbao YU ; Shengzheng WANG ; Jin TAO ; Yunlong LIU
Chinese Journal of Surgery 2024;62(11):996-1000
New quality productivity force is an advanced form of productive force that is innovation-driven, characterized by high technology, high efficiency, and high quality. It aligns with the new development philosophy and represents an advanced state of productivity. Within the medical sphere, this concept is epitomized by the progressive evolution of surgical instruments and techniques. In recent years, the rapid development of new quality productivity forces in the medical field has generated significant anticipation for innovations in urological robotic surgery instruments and techniques. Advancements in domestically produced robotic surgery systems, remote robotic surgery, single-port robotic surgery, and pediatric-specific robotic surgery exemplify the critical application of new quality productivity forces in urology. The integration of artificial intelligence, haptic feedback technology, and sensory enhancement technologies has further enhanced the safety and precision of surgeries. Driven by these new quality productivity forces, the development of urological robotic surgery instruments and techniques has reached a new milestone, potentially setting a new gold standard for urological surgeries and providing patients with safer, more efficient, and personalized medical care. However, certain emerging technologies still face challenges in their application, necessitating further research and clinical validation.
6.Targeting the chromatin structural changes of antitumor immunity
Li NIAN-NIAN ; Lun DENG-XING ; Gong NINGNING ; Meng GANG ; Du XIN-YING ; Wang HE ; Bao XIANGXIANG ; Li XIN-YANG ; Song JI-WU ; Hu KEWEI ; Li LALA ; Li SI-YING ; Liu WENBO ; Zhu WANPING ; Zhang YUNLONG ; Li JIKAI ; Yao TING ; Mou LEMING ; Han XIAOQING ; Hao FURONG ; Hu YONGCHENG ; Liu LIN ; Zhu HONGGUANG ; Wu YUYUN ; Liu BIN
Journal of Pharmaceutical Analysis 2024;14(4):460-482
Epigenomic imbalance drives abnormal transcriptional processes,promoting the onset and progression of cancer.Although defective gene regulation generally affects carcinogenesis and tumor suppression networks,tumor immunogenicity and immune cells involved in antitumor responses may also be affected by epigenomic changes,which may have significant implications for the development and application of epigenetic therapy,cancer immunotherapy,and their combinations.Herein,we focus on the impact of epigenetic regulation on tumor immune cell function and the role of key abnormal epigenetic processes,DNA methylation,histone post-translational modification,and chromatin structure in tumor immunogenicity,and introduce these epigenetic research methods.We emphasize the value of small-molecule inhibitors of epigenetic modulators in enhancing antitumor immune responses and discuss the challenges of developing treatment plans that combine epigenetic therapy and immuno-therapy through the complex interaction between cancer epigenetics and cancer immunology.
7.Emphasizing the innovation of urological robotic-assisted surgical instruments and technology driven by new quality productivity forces
Xuepei ZHANG ; Zhaowei ZHU ; Pin ZHAO ; Shuanbao YU ; Shengzheng WANG ; Jin TAO ; Yunlong LIU
Chinese Journal of Surgery 2024;62(11):996-1000
New quality productivity force is an advanced form of productive force that is innovation-driven, characterized by high technology, high efficiency, and high quality. It aligns with the new development philosophy and represents an advanced state of productivity. Within the medical sphere, this concept is epitomized by the progressive evolution of surgical instruments and techniques. In recent years, the rapid development of new quality productivity forces in the medical field has generated significant anticipation for innovations in urological robotic surgery instruments and techniques. Advancements in domestically produced robotic surgery systems, remote robotic surgery, single-port robotic surgery, and pediatric-specific robotic surgery exemplify the critical application of new quality productivity forces in urology. The integration of artificial intelligence, haptic feedback technology, and sensory enhancement technologies has further enhanced the safety and precision of surgeries. Driven by these new quality productivity forces, the development of urological robotic surgery instruments and techniques has reached a new milestone, potentially setting a new gold standard for urological surgeries and providing patients with safer, more efficient, and personalized medical care. However, certain emerging technologies still face challenges in their application, necessitating further research and clinical validation.
8.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
9.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
10.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.

Result Analysis
Print
Save
E-mail