1.Noninvasive Screening for Chronic Atrophic Gastritis Using Photoplethysmography-derived Meridian-labelled Harmonic Parameters
Yun-Qing LE ; Jian-Xin CHEN ; Ai-Ping CHEN ; Zhi-Hong LI
Progress in Biochemistry and Biophysics 2026;53(5):1178-1194
ObjectiveChronic atrophic gastritis (CAG) is usually diagnosed by gastroscopy and histopathological biopsy. These procedures remain the reference standard, but their invasive nature and resource requirements may limit their use in large-scale population screening and repeated follow-up. A convenient and reproducible method for noninvasive auxiliary screening may help identify individuals who require further endoscopic assessment. Fingertip photoplethysmography (PPG) provides a noninvasive recording of peripheral pulse waves and allows harmonic features to be extracted from the signal. In this study, the so-called meridian-related variables were defined as PPG-derived harmonic parameters labelled according to meridian nomenclature, rather than as direct measurements of meridian physiology. This study aimed to compare these harmonic parameters between patients with CAG and non-CAG controls, identify parameters that remained different after age adjustment, and develop a multivariable model for noninvasive auxiliary screening and pre-endoscopic risk stratification of CAG. MethodsA total of 343 participants were included, comprising 171 patients with CAG and 172 non-CAG controls. CAG diagnosis was established using gastroscopy and histopathology as the reference standard. Fingertip PPG signals were collected using a PPG-based pulse acquisition device. Eight PPG-derived harmonic parameters labelled according to meridian nomenclature were extracted for analysis. Between-group differences were first assessed using nonparametric tests. Age-adjusted analyses were then performed to reduce potential confounding by age. The false discovery rate (FDR) method was applied for multiple-comparison correction. A multivariable logistic regression model integrating age and multiple harmonic parameters was constructed. Model performance was evaluated using receiver operating characteristic (ROC) analysis and the area under the curve (AUC). Internal validation performance was assessed using stratified five-fold cross-validation and bootstrap optimism correction. Threshold performance was examined using both a high-specificity strategy and a Youden index-based cutoff. Decision curve analysis was used to evaluate the model’s net clinical benefit across a range of threshold probabilities. ResultsAll eight harmonic parameters were non-normally distributed. In the univariate analysis, the stomach-labelled harmonic parameter (ST), bladder-labelled harmonic parameter (BL), and liver-labelled harmonic parameter (LR) differed between the CAG and non-CAG groups. After age adjustment and FDR correction, only ST and BL remained statistically significant. Compared with non-CAG controls, patients with CAG showed higher ST values and lower BL values. This finding indicates an associated differential harmonic pattern that was not fully explained by age distribution. However, the discriminative ability of a single harmonic parameter was limited. The best-performing single indicator was ST, with an AUC of 0.652 (95% CI: 0.595-0.707). The multivariable model integrating age and multiple harmonic parameters achieved an AUC of 0.791 (95% CI: 0.743-0.835), representing an improvement of 0.139 over ST alone. In internal validation, stratified five-fold cross-validation yielded a mean AUC of 0.753 (95% CI: 0.715-0.781), and the bootstrap optimism-corrected AUC was 0.748. These results suggest that the model retained moderate discriminative performance after internal validation.At a specificity of at least 95%, the model achieved a sensitivity of only 40.4% (95% CI: 25.7%-49.7%). This high-specificity cutoff may be suboptimal as the preferred threshold for an initial screening setting because of the potential risk of missed CAG cases. The Youden index-based optimal cutoff was 0.419, corresponding to a sensitivity of 80.7% and a specificity of 62.8%. This threshold may better match the practical aim of noninvasive auxiliary screening, where sensitivity is usually prioritized to reduce missed cases. Decision curve analysis showed that, within a threshold probability range of 10%-55%, the model provided higher net clinical benefit than the reference strategies of recommending gastroscopy for all participants or for none. ConclusionPatients with CAG showed associated harmonic differences in fingertip PPG-derived features, mainly characterized by higher ST and lower BL values after age adjustment and FDR correction. Compared with a single harmonic parameter, the multivariable model showed better overall discrimination and retained moderate internal validation performance. These findings suggest that PPG-derived harmonic parameters labelled according to meridian nomenclature may provide auxiliary information for noninvasive auxiliary screening and front-line triage before gastroscopic confirmation in CAG. The present results support further validation rather than immediate clinical implementation. External validation in independent, multicenter, and preferably prospective screening cohorts is needed to assess the model’s generalizability, screening performance, and potential clinical utility.
2.Noninvasive Screening for Chronic Atrophic Gastritis Using Photoplethysmography-derived Meridian-labelled Harmonic Parameters
Yun-Qing LE ; Jian-Xin CHEN ; Ai-Ping CHEN ; Zhi-Hong LI
Progress in Biochemistry and Biophysics 2026;53(5):1178-1194
ObjectiveChronic atrophic gastritis (CAG) is usually diagnosed by gastroscopy and histopathological biopsy. These procedures remain the reference standard, but their invasive nature and resource requirements may limit their use in large-scale population screening and repeated follow-up. A convenient and reproducible method for noninvasive auxiliary screening may help identify individuals who require further endoscopic assessment. Fingertip photoplethysmography (PPG) provides a noninvasive recording of peripheral pulse waves and allows harmonic features to be extracted from the signal. In this study, the so-called meridian-related variables were defined as PPG-derived harmonic parameters labelled according to meridian nomenclature, rather than as direct measurements of meridian physiology. This study aimed to compare these harmonic parameters between patients with CAG and non-CAG controls, identify parameters that remained different after age adjustment, and develop a multivariable model for noninvasive auxiliary screening and pre-endoscopic risk stratification of CAG. MethodsA total of 343 participants were included, comprising 171 patients with CAG and 172 non-CAG controls. CAG diagnosis was established using gastroscopy and histopathology as the reference standard. Fingertip PPG signals were collected using a PPG-based pulse acquisition device. Eight PPG-derived harmonic parameters labelled according to meridian nomenclature were extracted for analysis. Between-group differences were first assessed using nonparametric tests. Age-adjusted analyses were then performed to reduce potential confounding by age. The false discovery rate (FDR) method was applied for multiple-comparison correction. A multivariable logistic regression model integrating age and multiple harmonic parameters was constructed. Model performance was evaluated using receiver operating characteristic (ROC) analysis and the area under the curve (AUC). Internal validation performance was assessed using stratified five-fold cross-validation and bootstrap optimism correction. Threshold performance was examined using both a high-specificity strategy and a Youden index-based cutoff. Decision curve analysis was used to evaluate the model’s net clinical benefit across a range of threshold probabilities. ResultsAll eight harmonic parameters were non-normally distributed. In the univariate analysis, the stomach-labelled harmonic parameter (ST), bladder-labelled harmonic parameter (BL), and liver-labelled harmonic parameter (LR) differed between the CAG and non-CAG groups. After age adjustment and FDR correction, only ST and BL remained statistically significant. Compared with non-CAG controls, patients with CAG showed higher ST values and lower BL values. This finding indicates an associated differential harmonic pattern that was not fully explained by age distribution. However, the discriminative ability of a single harmonic parameter was limited. The best-performing single indicator was ST, with an AUC of 0.652 (95% CI: 0.595-0.707). The multivariable model integrating age and multiple harmonic parameters achieved an AUC of 0.791 (95% CI: 0.743-0.835), representing an improvement of 0.139 over ST alone. In internal validation, stratified five-fold cross-validation yielded a mean AUC of 0.753 (95% CI: 0.715-0.781), and the bootstrap optimism-corrected AUC was 0.748. These results suggest that the model retained moderate discriminative performance after internal validation.At a specificity of at least 95%, the model achieved a sensitivity of only 40.4% (95% CI: 25.7%-49.7%). This high-specificity cutoff may be suboptimal as the preferred threshold for an initial screening setting because of the potential risk of missed CAG cases. The Youden index-based optimal cutoff was 0.419, corresponding to a sensitivity of 80.7% and a specificity of 62.8%. This threshold may better match the practical aim of noninvasive auxiliary screening, where sensitivity is usually prioritized to reduce missed cases. Decision curve analysis showed that, within a threshold probability range of 10%-55%, the model provided higher net clinical benefit than the reference strategies of recommending gastroscopy for all participants or for none. ConclusionPatients with CAG showed associated harmonic differences in fingertip PPG-derived features, mainly characterized by higher ST and lower BL values after age adjustment and FDR correction. Compared with a single harmonic parameter, the multivariable model showed better overall discrimination and retained moderate internal validation performance. These findings suggest that PPG-derived harmonic parameters labelled according to meridian nomenclature may provide auxiliary information for noninvasive auxiliary screening and front-line triage before gastroscopic confirmation in CAG. The present results support further validation rather than immediate clinical implementation. External validation in independent, multicenter, and preferably prospective screening cohorts is needed to assess the model’s generalizability, screening performance, and potential clinical utility.
3.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
4.Key Factors and Improving Paths of Promoting Long-Acting Injections in Communities in Beijing.
Yu XIN ; Chen CHEN ; Yao DONG ; Jin-Qi ZHU ; Yun CHEN ; Qing-Zhi HUANG ; Jun-Li ZHU
Acta Academiae Medicinae Sinicae 2025;47(3):414-424
Objective To investigate the key factors influencing the implementation of long-acting injection-promoting policies and propose effective improving paths.Methods Qualitative interviews were carried out for stakeholders involved in the promotion of long-acting injections,based on the consolidated framework for implementation research.Additionally,countermeasures for identified barriers were proposed based on expert recommendations for implementation changes.Results A total of 46 health administrators,healthcare workers,and patients in Beijing were interviewed.The study identified several barriers in the strength and quality of evidence,adaptability,relative advantage,complexity and cost,patient needs and resources,external collaboration,external policies and incentives,organizational structural characteristics,and self-efficacy.Conclusions From the perspectives and experiences of stakeholders,the promotion of long-acting injections has shown initial success but still faces multiple obstacles.It is recommended that efforts should be made to coordinate and adapt policies,improve and incentivize relative organizations,and continuously strengthen the advocacy and education for individuals.
Humans
;
Beijing
;
Delayed-Action Preparations
;
Health Personnel
;
Health Policy
;
Injections
5.Analysis on Care Service Preferences of Community Patients With Severe Mental Disorders in Beijing Based on Discrete Choice Experiment.
Jin-Qi ZHU ; Wei LU ; Yu XIN ; Yun CHEN ; Qing-Zhi HUANG ; Jun-Li ZHU
Acta Academiae Medicinae Sinicae 2025;47(3):425-433
Objective To gain insights into the care service preferences and willingness of patients with severe mental disorders in Beijing,analyze the main factors affecting their participation in care services,and provide data support and decision-making reference for the optimal design of care services for patients with severe mental disorders and the improvement of relevant policies.Methods In July 2022,a questionnaire survey was conducted for a part of Beijing community patients with severe mental disorders selected by multi-stage stratified sampling,including the basic personal information and the preferences of discrete choice experiment.A mixed Logit model was used to perform regression analysis on the care service preferences,and the trade off between general and monetary attributes was quantified by willingness to pay(WTP).Results A total of 242 questionnaires were distributed,and 181 valid questionnaires were collected,with a response rate of 74.79%.The regression coefficients for the four attributes-service type,service content,service frequency,and service cost-all showed statistical significance(all P<0.05).Patients' most preferred attribute level was a service frequency covering about 90% of the time per month/year( β=1.059),while the least preferred was full-time residential care( β=-1.025).Increasing the service frequency from 30% to 90% corresponded to a WTP of 492.5 yuan,while changing the service type from home-based care to full-time residential care resulted in a WTP of -476.6 yuan.Moreover,there were differences in care service preferences and WTP among patient groups with different characteristics(all P<0.05).Conclusions Service type,service content,service frequency,and service cost all significantly affect the care service preferences of patients with severe mental disorders.There is heterogeneity in care service preferences among patient groups with different characteristics.
Humans
;
Mental Disorders/therapy*
;
Patient Preference
;
Beijing
;
Surveys and Questionnaires
;
Male
;
Female
;
Choice Behavior
;
Adult
;
Middle Aged
6.Creation and Exploration of the"Organized Fill-in-the-Blank Format"Disci-pline Construction Model for Forensic Medicine in the New Era
Zhi-Wen WEI ; Hong-Xing WANG ; Jun-Hong SUN ; Hao-Liang FAN ; Hong-Liang SU ; Le-Le WANG ; Wen-Ting HE ; Zhe CHEN ; Jie ZHANG ; Xiang-Jie GUO ; Ji LI ; Geng-Qian ZHANG ; Xin-Hua LIANG ; Jiang-Wei YAN ; Qiang-Qiang ZHANG ; Cai-Rong GAO ; Ying-Yuan WANG ; Hong-Wei WANG ; Jun XIE ; Bo-Feng ZHU ; Ke-Ming YUN
Journal of Forensic Medicine 2025;41(1):25-29
Forensic medicine has been designated as a first-level discipline,presenting new opportunities and challenges for the development of forensic medicine.Since the 1980s,the establishment of foren-sic medicine discipline and the cultivation of high-level forensic talents have become hot topics in the development of forensic medicine in China.Since the 13th Five-Year Plan,the forensic team of Shanxi Medical University has been aiming at the forefront,proposing the development goals of"Five First-class"and the discipline development path"Six Major Achievements".It has selected benchmark disci-plines,identified gaps in disciplinary development,unified thoughts,formulated completion timelines,concentrated superior resources,assigned tasks to individuals,and created an"Organized Fill-in-the-Blank Format"forensic medicine discipline construction model with the characteristics of the new era.The construction model of forensic medicine has achieved good results in the goals,discipline frame-work,scientific research,talent cultivation,discipline team and platform construction,forming a rela-tively complete discipline construction and management system,and accumulating valuable experience for the construction of first-level discipline and high-level talent cultivation of forensic medicine.
7.Validation and Forensic Application of a Domestic Human DNA Quantitative De-tection Kit
Jing CHEN ; Ya-Ping WANG ; Yun-Peng FENG ; Xiao-Xin HU ; Zhen-Jun JIA ; Hong-Di LIU ; An-Xin YAN ; Yong-Jiu LI ; Zhu PENG ; Zhi-Fang LIU ; Jian-Gang CHEN
Journal of Forensic Medicine 2025;41(3):252-259
Objective To verify the efficacy of a domestic human DNA quantification kit based on real-time fluorescence quantitative PCR in detecting the total human DNA concentration,male DNA concen-tration in mixed male/female DNA samples,the degree of DNA degradation and inhibitor tolerance.Methods Samples with different concentrations,different male/female ratios,different concentrations of inhibitors,and different degradation degrees were tested using the domestic human DNA quantification kit based on real-time fluorescence quantitative PCR.This kit was compared with a similar product on the market and was applied to the detection of DNA from real cases.Results This human DNA quan-tification kit can effectively detect human DNA as low as 0.001 65 ng/μL,and 6.25 pg/μL of male DNA in mixed samples with a male-to-female ratio of 1∶15 000.Even when the sample contains as high as 400 ng/μL of humic acid or 1 000 μmol/L of hemin alone,the DNA concentration can still be accurately detected.The degradation index can effectively characterize the degradation degree of the sample.This kit has been successfully applied in forensic practice.Conclusion This human DNA quan-tification kit is accurate and reliable in detection.It can accurately reflect the degradation of DNA and inhibitor tolerance.It has good performance in quantitative accuracy,determination of the male/female ratio in mixed samples,and inhibitor tolerance.It has application potential in forensic case examination.
8.Detection of Ketamine and Norketamine Using an Aptamer-Functionalized Gra-phene Oxide Fluorescent Sensor
Li-Xia WEI ; Bo LIU ; Xiao-Yuan YANG ; Xi ZHANG ; Yi-Feng LAN ; Chao ZHANG ; Juan JIA ; Dan ZHANG ; Zhi-Wen WEI ; Ke-Ming YUN ; Zhe CHEN
Journal of Forensic Medicine 2025;41(4):326-339
Objective To construct an aptamer-functionalized carboxylated graphene oxide(CGO)fluo-rescent sensor to achieve highly sensitive and specific detection of ketamine(KET)and its metabolite norketamine(NK)using an aptamer capable of simultaneously recognizing KET and NK.Methods A specific aptamer for simultaneous recognition of KET and NK was screened using graphene oxide-sys-tematic evolution of ligand by exponential enrichment(GO-SELEX)and molecular docking tech-niques.The aptamer,labeled with Cy5 fluorescence,was chemically conjugated to CGO to construct an aptamer-functionalized CGO fluorescent sensor.By optimizing detection conditions,including the mass concentration of CGO,aptamer concentration,reaction temperature,and incubation time,quantita-tive analysis of the target analytes was achieved using the ratio of fluorescence intensity changes be-fore and after target addition.The stability of the sensor in biological matrices was evaluated by moni-toring fluorescence intensity changes over incubation time in blank blood and urine,in comparison with the traditional physical adsorption-based CGO fluorescent sensor.Spiked recovery experiments in blank blood and urine were conducted to compare performance with that of HPLC-MS/MS.Results A specific aptamer A5 was selected and chemically conjugated with CGO to construct the aptamer-functionalized CGO fluorescent sensor.Under optimized conditions,the proposed fluorescent sensor ex-hibited a linear detection range of 1.0-5.0 ng/mL for KET,with a limit of detection(LOD)of 0.86 ng/mL;while for NK,the linear detection range was 1.0-5.0 ng/mL,with an LOD of 0.70 ng/mL.Com-pared with the CGO fluorescent sensor constructed via physical adsorption,this sensor demonstrated greater stability in blood and urine.The spiked recovery rates of KET and NK in blank blood and urine ranged from 81.50%to 110.03%,exhibiting detection performance comparable to that of HPLC-MS/MS.Conclusion The aptamer screening method offers a novel approach for selecting aptamers tar-geting drugs and their metabolites.The constructed aptamer-functionalized CGO fluorescent sensor pro-vides an efficient and reliable strategy for the high-performance detection of KET and NK.
9.Toxicokinetics of Chlorfenapyr and Its Metabolites in Rats
Wen-Yan LI ; Jin-Feng ZHAO ; Wei-Chen LIU ; Shi-Jing LÜ ; Jia-Xin ZHANG ; Xu-Dong ZHANG ; Zhi-Wen WEI ; Ke-Ming YUN ; Chao ZHANG
Journal of Forensic Medicine 2025;41(4):380-386
Objective To establish a chromatography-tandem mass spectrometry method for detecting chlorfenapyr and its metabolite tralopyril in blood,and to investigate the toxicokinetics in rats.Methods Chlorfenapyr(8 mg/kg)was administered orally to rats,and blood samples were collected from rats'canthus vein at 5 min,15 min,30 min,1 h,3 h,6 h,12 h,24 h and 48 h after administration.The blood samples were extracted using 100 μL of 5%formic acid solution and 400 μL of acetonitrile.Chlorfena-pyr was qualitatively and quantitatively detected by triple quadrupole gas chromatography-tandem mass spectrometry(GC-MS/MS)and tralopyril was detected by triple quadrupole liquid chromatography-tandem mass spectrometry(LC-MS/MS).The DAS 3.0 software was used to fit the toxicokinetic equa-tions and calculate the toxicokinetic parameters.Results Chlorfenapyr was detectable from 5 min to 24 h with a peak time of 1 h.Tralopyril was detectable from 15 min to 48 h with a peak time of 3 h.The toxicokinetic process of chlorfenapyr in rat blood conformed to a first-order absorption one-compartment open model,with the toxicokinetic equation described as C=e-0.265t-e-0.175t.Tralopyril con-formed to the first-order absorption three-compartment model,and the toxicokinetic equation was C=47 361.069e-2.209t-35 404.962e-1.486t+11 956.363e-0.512t.In the equations,C stands for the concentration of the target substance in the blood,e is the natural constant(≈2.718 28),and t stands for time.Conclu-sion This study optimized the detection method for chlorfenapyr and its metabolite tralopyril in blood.The toxicokinetic equations and parameters of chlorfenapyr and tralopyril can provide a reference for the estimation of oral intake time of chlorfenapyr.
10.Moxibustion combined with low-dose tadalafil for diabetes mellitus-induced erectile dysfunction: A prospective, single-center, three-arm randomized controlled trial.
Tao LIU ; Zhao-Xu YANG ; Yan XU ; Qi ZHAO ; Xue LIU ; Xin-Fei HUANG ; Zhi-Xing SUN ; Yun CHEN ; Jian-Huai CHEN
National Journal of Andrology 2025;31(2):55-60
OBJECTIVE:
To investigate the clinical efficacy of moxibustion (Mox) combined with low-dose tadalafil (TAD) in the treatment of diabetes mellitus-induced erectile dysfunction (DMED) with the syndrome of Qi deficiency and blood stasis.
METHODS:
According to the inclusion and exclusion criteria, we selected 90 patients with DMED for this trial and equally randomized them into a Mox, a TAD, and a Mox combined with TAD (Mox+TAD) group to be treated by mild Mox applied to the acupoints Zusanli, Sanyinjiao and Yinlingquan qd alt, oral medication with low-dose TAD at 5 mg per dose qd, and combination of the above two therapies, respectively, all for 4 weeks. We obtained from the patients their IIEF-5 scores, traditional Chinese medicine (TCM) symptoms scores, Erectile Hardness Scale (EHS) scores, corpus cavernosal hemodynamic indexes, and the peak systolic velocity (PSV), end diastolic velocity (EDV) and resistance index (RI) of the corpus cavernosal arteries before and after treatment, and compared them among the three groups.
RESULTS:
The total effectiveness rate was significantly higher in the Mox+TAD (90.0%) than in the Mox (46.7%) and TAD groups (60.0%) (P< 0.05). Compared with the baseline, the IIEF-5 and EHS scores were increased, while the TCM symptoms scores decreased in all the three groups after treatment, more significantly in the Mox+TAD group than in the other two (P< 0.05). And the PSV and RI were remarkably increased, while the EDV decreased (P< 0.05) in all the three groups (P< 0.05) after treatment, with PSV even higher in the Mox+TAD than in the Mox and TAD groups (P< 0.05).
CONCLUSION
Moxibustion combined with tadalafil has a definite efficacy and safety for the treatment of DMED, which can effectively improve the erectile function of the patients by increasing penile blood supply, benefiting qi and activating blood circulation.
Humans
;
Male
;
Tadalafil
;
Erectile Dysfunction/etiology*
;
Moxibustion
;
Middle Aged
;
Prospective Studies
;
Adult
;
Carbolines/administration & dosage*
;
Diabetes Complications/therapy*
;
Aged
;
Treatment Outcome
;
Combined Modality Therapy

Result Analysis
Print
Save
E-mail