1.Research progress of nano drug delivery system based on metal-polyphenol network for the diagnosis and treatment of inflammatory diseases
Meng-jie ZHAO ; Xia-li ZHU ; Yi-jing LI ; Zi-ang WANG ; Yun-long ZHAO ; Gao-jian WEI ; Yu CHEN ; Sheng-nan HUANG
Acta Pharmaceutica Sinica 2025;60(2):323-336
Inflammatory diseases (IDs) are a general term of diseases characterized by chronic inflammation as the primary pathogenetic mechanism, which seriously affect the quality of patient′s life and cause significant social and medical burden. Current drugs for IDs include nonsteroidal anti-inflammatory drugs, corticosteroids, immunomodulators, biologics, and antioxidants, but these drugs may cause gastrointestinal side effects, induce or worsen infections, and cause non-response or intolerance. Given the outstanding performance of metal polyphenol network (MPN) in the fields of drug delivery, biomedical imaging, and catalytic therapy, its application in the diagnosis and treatment of IDs has attracted much attention and significant progress has been made. In this paper, we first provide an overview of the types of IDs and their generating mechanisms, then sort out and summarize the different forms of MPN in recent years, and finally discuss in detail the characteristics of MPN and their latest research progress in the diagnosis and treatment of IDs. This research may provide useful references for scientific research and clinical practice in the related fields.
2.Discovery and investigation of six polio vaccine derived viruses in Guangzhou City
Min CUI ; Chunhuan ZHANG ; Wei ZHANG ; Jun LIU ; Jialing LI ; Jianxiong XU ; Wenji WANG ; Qing HE ; Lihong NI ; Xuexia YUN ; Huanying ZHENG
Journal of Public Health and Preventive Medicine 2025;36(2):22-25
Objective To understand the surveillance situation of poliovirus in Guangzhou from 2011 to 2024, and to further strengthen polio surveillance and ensure the continued maintenance of a polio-free status. Methods An analysis was conducted on the discovery and investigation results of six cases of vaccine-derived poliovirus (VDPV) detected in Guangzhou. Results A total of 6 VDPV incidents were reported in Guangzhou from 2011 to June 2024, among which 5 incidents were from sewage sample testing in the Liede Sewage Treatment Plant in Guangzhou, all of which were confirmed as VDPV, with 1 for type I, 1 for type II, and 3 for type III. In addition, one confirmed HFMD case was identified as a type VDPV II carrier. No presence of any wild poliovirus (WPV), VDPV cases, or circulating VDPV (cVDPV) was reported. Conclusion Guangzhou City has maintained a high level of vigilance and effectiveness in the monitoring and prevention of polio. Continuously strengthening the construction of the polio monitoring network, optimizing vaccination strategies, and comprehensively improving public health awareness are still the focus of the prevention and control work in the future.
3.Nutrition literacy of primary and secondary school students and its influencing factors in Shijingshan District of Beijing
Deyue XU ; Mingliang WANG ; Wei WANG ; Yingjie YU ; Shuiying YUN ; Bo YANG ; Yunzheng YAN ; Lingyan SU
Journal of Public Health and Preventive Medicine 2025;36(2):126-130
Objective To understand the current situation of nutrition literacy of primary and secondary school students in Shijingshan District of Beijing, and analyze its influencing factors, and to put forward targeted suggestions for improving the students’ nutrition literacy and promoting their healthy growth. Methods A multi-stage stratified cluster sampling method was used to select 2480 primary and secondary school students and their parents from 5 primary schools, 3 middle schools and 1 high school in Shijingshan District. The multivariate logistic regression model was used to analyze the factors influencing the attainment rate of nutrition literacy. Results The median score of nutrition literacy of 2480 primary and secondary school students from grades 1 to 12 was 77.86 (in hundred-mark system), the quartile range (IQR) was 16.96, and the attainment rate of nutrition literacy was 42.46%. The cognitive level (45.12%) was higher than the skill level (41.20%) among students from grades 3 to 12. In terms of skills, the attainment rate of food preparation was the lowest, at 30.38%. The scores of nutrition literacy of girls were higher than those of boys, and the scores of primary school students were higher than those of secondary school students. Students with different levels of caregiver’s education, family income, and family food environment had different scores of nutrition literacy, and the differences were statistically significant (P<0.05). Multivariate logistic regression analysis showed that the attainment rate of nutrition literacy was closely related to student’s gender and study stage, caregiver’s education level, and family food environment. Conclusion The nutrition literacy of primary and secondary school students in Shijingshan District still needs to be improved, especially in the aspect of skills. Targeted nutrition education should be carried out.
4.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
5.A new classification of atlas fracture based on computed tomography: reliability, reproducibility, and preliminary clinical significance
Yun-lin CHEN ; Wei-yu JIANG ; Wen-jie LU ; Xu-dong HU ; Yang WANG ; Wei-hu MA
Asian Spine Journal 2025;19(1):3-9
Methods:
Seventy-five patients with atlas fracture were included from January 2015 to December 2020. Based on the anatomy of the fracture line, atlas fractures were divided into three types. Each type was divided into two subtypes according to the fracture displacement. Unweighted Cohen kappa coefficients were applied to evaluate the reliability and reproducibility.
Results:
According to the new classification, 17 cases of type A1, 12 of type A2, seven of type B1, 13 of type B2, 12 of type C1, and 14 of type C2 were identified. The K-values of the interobserver and intraobserver reliability were 0.846 and 0.912, respectively, for the new classification. The K-values of interobserver reliability for types A, B, and C were 0.843, 0.799, and 0.898, respectively. The K-values of intraobserver reliability for types A, B, and C were 0.888, 0.910, and 0.935, respectively. The mean K-values of the interobserver and intraobserver reliability for subtypes were 0.687 and 0.829, respectively.
Conclusions
The new classification of atlas fractures can cover nearly all atlas fractures. This system is the first to evaluate the severity of fractures based on the C1 articular facet and fracture displacement and strengthen the anatomy ring of the atlas. It is concise, easy to remember, reliable, and reproducible.
6.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
7.Enzyme-directed Immobilization Strategies for Biosensor Applications
Xing-Bao WANG ; Yao-Hong MA ; Yun-Long XUE ; Xiao-Zhen HUANG ; Yue SHAO ; Yi YU ; Bing-Lian WANG ; Qing-Ai LIU ; Li-He ZHANG ; Wei-Li GONG
Progress in Biochemistry and Biophysics 2025;52(2):374-394
Immobilized enzyme-based enzyme electrode biosensors, characterized by high sensitivity and efficiency, strong specificity, and compact size, demonstrate broad application prospects in life science research, disease diagnosis and monitoring, etc. Immobilization of enzyme is a critical step in determining the performance (stability, sensitivity, and reproducibility) of the biosensors. Random immobilization (physical adsorption, covalent cross-linking, etc.) can easily bring about problems, such as decreased enzyme activity and relatively unstable immobilization. Whereas, directional immobilization utilizing amino acid residue mutation, affinity peptide fusion, or nucleotide-specific binding to restrict the orientation of the enzymes provides new possibilities to solve the problems caused by random immobilization. In this paper, the principles, advantages and disadvantages and the application progress of enzyme electrode biosensors of different directional immobilization strategies for enzyme molecular sensing elements by specific amino acids (lysine, histidine, cysteine, unnatural amino acid) with functional groups introduced based on site-specific mutation, affinity peptides (gold binding peptides, carbon binding peptides, carbohydrate binding domains) fused through genetic engineering, and specific binding between nucleotides and target enzymes (proteins) were reviewed, and the application fields, advantages and limitations of various immobilized enzyme interface characterization techniques were discussed, hoping to provide theoretical and technical guidance for the creation of high-performance enzyme sensing elements and the manufacture of enzyme electrode sensors.
8.Analysis of The Application and Prospects of CRISPR-based RNA Detection Technology in Forensic Science
Yun FANG ; Xian-Miao WANG ; Wei XIE ; Qi-Fan SUN
Progress in Biochemistry and Biophysics 2025;52(10):2602-2613
The emergence of clustered regularly interspaced short palindromic repeat (CRISPR) and CRISPR-associated proteins (Cas) system represents a revolutionary paradigm shift in molecular diagnostics, offering transformative potential for RNA analysis within the rigorous demands of forensic science. Conventional forensic RNA detection methodologies, such as reverse transcription-quantitative polymerase chain reaction (RT-qPCR) or microarray analysis, are significantly hampered by inherent limitations including complex, multi-step protocols requiring sophisticated laboratory infrastructure, pronounced susceptibility to inhibitors prevalent in complex forensic matrices (e.g., humic acids, heme, indigo dyes), and often inadequate sensitivity for trace or degraded samples typical of crime scenes, thereby failing to meet the critical operational imperatives of forensic practice: rapidity, high specificity, sensitivity, portability, and robustness against interference. This review posits that CRISPR-Cas-based RNA detection technology provides a groundbreaking solution by leveraging the programmable, sequence-specific recognition conferred by the synergistic interaction between a designed guide RNA (gRNA) and Cas effector proteins (e.g., Cas12a, Cas13a, Cas14). Upon target RNA binding, specific Cas enzymes undergo conformational activation, exhibiting collateral cleavage activity―a unique catalytic amplification mechanism where the enzyme non-specifically cleaves surrounding reporter molecules, enabling ultra-high sensitivity. To further enhance detection limits, CRISPR-Cas systems are strategically integrated with isothermal pre-amplification techniques like recombinase polymerase amplification (RPA) or loop-mediated isothermal amplification (LAMP), which efficiently amplify target RNA at constant temperatures, eliminating the need for thermal cyclers. This powerful cascade―isothermal pre-amplification followed by CRISPR-mediated sequence-specific recognition and collateral signal amplification―achieves exceptional sensitivity, often down to the single-molecule (attomolar) level, while drastically reducing analysis time to potentially 30-60 min. Crucially, the compatibility of CRISPR-Cas detection with simple, equipment-free readout systems, such as lateral flow strips (LFS) for visual colorimetric results or portable fluorescence/electrochemical sensors, facilitates true point-of-need (PON) forensic analysis directly at crime scenes, morgues, or field labs. This enables rapid applications like specific body fluid identification (e.g., distinguishing menstrual blood via miRNA, identifying saliva via mRNA), post-mortem interval (PMI) estimation through RNA degradation/expression patterns, donor age inference via age-related RNA markers, tissue identification, and microbial forensics, thereby accelerating investigative leads, minimizing sample degradation risks, and optimizing resource allocation. However, significant challenges impede widespread adoption, including persistent environmental interference inhibiting enzymes, fluctuations in Cas/amplification enzyme activity affecting reproducibility, a critical lack of standardized protocols and validated quality assurance/quality control (QA/QC) frameworks essential for forensic reliability and court admissibility, and current limitations in multiplex detection capability. Consequently, future research must prioritize overcoming multiplexing bottlenecks for comprehensive analysis, enhancing system robustness through Cas protein engineering and optimized reagents, developing fully integrated, sample-to-answer microfluidic or lateral flow devices for user-friendly field deployment, and collaboratively establishing universally accepted validation guidelines, performance standards, and stringent QA/QC procedures. Furthermore, the urgent development of clear ethical guidelines governing the use of this highly sensitive technology, particularly concerning RNA data privacy and potential misuse, is imperative. This review systematically outlines the principles, forensic applications, current limitations, and future trajectories of CRISPR-RNA detection, with the authors’ conviction that focused efforts addressing these challenges will translate this technology into a cornerstone of next-generation forensic practice, driving unprecedented efficiency and innovation in field investigations and laboratory analysis to enhance justice delivery.
9.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
10.A new classification of atlas fracture based on computed tomography: reliability, reproducibility, and preliminary clinical significance
Yun-lin CHEN ; Wei-yu JIANG ; Wen-jie LU ; Xu-dong HU ; Yang WANG ; Wei-hu MA
Asian Spine Journal 2025;19(1):3-9
Methods:
Seventy-five patients with atlas fracture were included from January 2015 to December 2020. Based on the anatomy of the fracture line, atlas fractures were divided into three types. Each type was divided into two subtypes according to the fracture displacement. Unweighted Cohen kappa coefficients were applied to evaluate the reliability and reproducibility.
Results:
According to the new classification, 17 cases of type A1, 12 of type A2, seven of type B1, 13 of type B2, 12 of type C1, and 14 of type C2 were identified. The K-values of the interobserver and intraobserver reliability were 0.846 and 0.912, respectively, for the new classification. The K-values of interobserver reliability for types A, B, and C were 0.843, 0.799, and 0.898, respectively. The K-values of intraobserver reliability for types A, B, and C were 0.888, 0.910, and 0.935, respectively. The mean K-values of the interobserver and intraobserver reliability for subtypes were 0.687 and 0.829, respectively.
Conclusions
The new classification of atlas fractures can cover nearly all atlas fractures. This system is the first to evaluate the severity of fractures based on the C1 articular facet and fracture displacement and strengthen the anatomy ring of the atlas. It is concise, easy to remember, reliable, and reproducible.


Result Analysis
Print
Save
E-mail