1.Effect of Wearing Phospholipid-releasing Contact Lenses on Dry Eyes in Rabbits
Hyeon Jung KIM ; Sehie PARK ; Yun Kyoung RYU ; Jin Sun HWANG ; Sun Hee OH ; Jae Hwi LEE ; Gui Bae KIM ; Young Joo SHIN
Journal of the Korean Ophthalmological Society 2025;66(4):181-190
Purpose:
To investigate whether a new phospholipid-releasing soft contact lens can improve symptoms of dry eyes.
Methods:
The study used 2.5-3.0 kg New Zealand rabbits including both normal non-dry eye rabbits and dry eye rabbits, the latter having undergone electrocauterization of the meibomian glands to block the gland orifices. Each rabbit wore a control contact lens on one eye and a phospholipid-releasing contact lens on the other eye daily. Phospholipid-releasing and control contact lenses were provided by NEOVISION Co., Ltd. The parameters assessed included tear film break-up time, tear osmolarity, ocular surface staining, and central corneal thickness. After the experiment, the rabbits were euthanized and their conjunctival tissue was stained with Periodic Acid Schiff (PAS) to observe conjunctival goblet cells.
Results:
In both dry eye and normal non-dry eye rabbits, tear film break-up time was longer and tear osmolarity was lower when using the phospholipid-releasing contact lens compared to the control contact lens. The ocular surface remained unstained in normal non-dry eye rabbits while staining was observed in dry eye rabbits. There was no significant difference in central corneal thickness between the control and phospholipid-releasing contact lenses in either group. PAS staining showed no difference in conjunctival goblet cell density between the two lens types in normal non-dry eye rabbits. However, in dry eye rabbits, the conjunctival goblet cell density tended to be slightly higher with the phospholipid-releasing contact lens compared to the control lens.
Conclusions
Phospholipid-releasing contact lenses may help reduce dry eye symptoms and minimize contact lens-related complications by stabilizing the tear film and lowering tear osmolarity.
2.Hemicentral Retinal Vein Occlusion: Clinical Outcomes and Visual Prognostic Factors
Dong Woo LEE ; Do Yun SONG ; Mi-Ji KIM ; Yong Wun CHO ; Woong-Sun YOO ; In Young CHUNG
Journal of the Korean Ophthalmological Society 2025;66(2):94-100
Purpose:
To confirm the clinical features of hemicentral retinal vein occlusion and identify predictors of visual outcomes.
Methods:
A retrospective analysis was conducted on patients diagnosed with hemicentral retinal vein occlusion between January 2018 and December 2022 and followed for more than 6 months. Patients underwent intravitreal injections as necessary for intraretinal edema. Visual acuity, central macular thickness, ellipsoid zone damage, and the location of inner retinal layer edema were assessed. Patients were categorized into groups A and group B based on the visual acuity at 6 months.
Results:
In total, 20 eyes were followed, with 15 eyes observed for up to 12 months. Seven patients (35.0%) had diabetes and 11 (55.0%) had hypertension. There was a correlation between poor vision at 6 months and hypertension (p = 0.033). The visual acuity of all patients improved from a logMAR of 0.96 at the initial visit to a logMAR of 0.35 at 6 months (p = 0.005). In the group with good initial visual acuity, there were no significant changes in visual acuity during the follow-up period (p = 0.444). The group with good visual acuity at 6 months had a lower degree of photoreceptor ellipsoid zone disruption compared to the group with poor initial vision, indicating a normal structure (p = 0.015).
Conclusions
During follow-up of patients with hemicentral retinal vein occlusion, overall visual acuity improved over time. Patients with good initial acuity maintained it. Favorable visual outcomes can be expected if the ellipsoid zone has a normal structure at the time of the first examination.
3.Effect of regional COVID-19 outbreak to emergency department response on acute myocardial infarction: a multicenter retrospective study
Young Wook KIM ; Sungbae MOON ; Hyun Wook RYOO ; Jae Yun AHN ; Jung Bae PARK ; Dong Eun LEE ; Sang Hun LEE ; Sangchan JIN ; You Ho MUN ; Jung Ho KIM ; Tae Chang JANG
Journal of the Korean Society of Emergency Medicine 2025;36(2):72-82
Objective:
The Daegu region experienced the first wave of the pandemic at the beginning of the coronavirus disease 2019 (COVID-19) outbreak in Korea. Other non-COVID-19-related treatments during a community outbreak, such as cardiovascular diseases, were expected to impact emergency departments. In acute myocardial infarctions, time is an important factor affecting the patient outcome. This study examined how community COVID-19 outbreak affected STsegment elevated myocardial infarction (STEMI) care in emergency departments.
Methods:
A retrospective analysis was performed on patients visiting five emergency departments in the Daegu area who were diagnosed with STEMI from February 18 to April 17 each year from 2018 to 2020. The demographic characteristics, prehospital variables, in-hospital time variables, and treatment results were collected. The cases were divided into the pre-COVID period and the COVID period for comparison.
Results:
The study included 254 patients (194 pre-COVID, 60 during COVID). The symptom-to-door time did not differ. Although the door-to-first doctor time was shortened (4 min vs. 2 min, P=0.01), the rate of coronary angiogram along with the door-to-angiogram time and the door-to-balloon time did not change. The length of stay in the emergency department was delayed during COVID-19 (median, 136 min vs. 404 min; P<0.01). The in-hospital length of stay and mortality were similar in both groups.
Conclusion
The time to treat STEMI was not delayed significantly during the first wave of the COVID-19 outbreak in the Daegu area compared with the pre-pandemic period. Mortality did not change. The length of stay was elongated significantly in the emergency department but not in the hospital.
4.Sentinel Safety Monitoring System for Adverse Events of Special Interest Associated With Non-NIP Vaccines in Korea
Hakjun HYUN ; Jung Yeon HEO ; Yu Jung CHOI ; Eliel NHAM ; Jin Gu YOON ; Ji Yun NOH ; Joon Young SONG ; Woo Joo KIM ; Won Suk CHOI ; Min Joo CHOI ; Yu Bin SEO ; Jacob LEE ; Hee Jin CHEONG
Journal of Korean Medical Science 2025;40(16):e152-
South Korea’s current vaccination policies leave a surveillance gap for non-National Immunization Program (NIP) vaccines. In this study, we proposed a sentinel surveillance approach for monitoring the safety of non-NIP vaccines. Vaccination data were collected retrospectively among patients hospitalized with pre-defined adverse events of special interest (AESI) by reviewing electronic medical records in five university hospitals. This approach incorporates expert assessment to determine the causal relationship. We confirmed that 16 patients had received non-NIP vaccines among 860 patients diagnosed with AESI.We concluded one case of preeclampsia was possibly related to tetanus-diphtheria-pertussis vaccination. We propose a multi-hospital-based, retrospective assessment system for predefined AESIs as an alternative to active vaccine safety monitoring method. These efforts are expected to enhance both the accuracy and timeliness of safety monitoring in South Korea.
5.Consensus Statements on Tinnitus Assessment and Treatment Outcome Evaluation: A Delphi Study by the Korean Tinnitus Study Group
Oak-Sung CHOO ; Jung Mee PARK ; Euyhyun PARK ; Jiwon CHANG ; Min Young LEE ; Ho Yun LEE ; In Seok MOON ; Jae-Jun SONG ; Kyu-Yup LEE ; Jae-Jin SONG ; Eui-Cheol NAM ; Shi Nae PARK ; Hyun Joon SHIM ; Yoon Chan RAH ; Jae-Hyun SEO
Journal of Korean Medical Science 2025;40(7):e93-
Background:
Tinnitus is a multifactorial condition with no universally accepted assessment guidelines. The Korean Tinnitus Study Group previously established consensus statements on the definition, classification, and diagnostic tests for tinnitus. As a continuation of this effort, this study aims to establish expert consensus on tinnitus assessment and treatment outcome evaluation, specifically tailored to the Korean clinical context.
Methods:
A modified Delphi method involving 26 otology experts from across Korea was used. A two-round Delphi survey was conducted to evaluate statements related to tinnitus assessment before and after treatment. Statements were rated on a scale of 1 to 9 for the level of agreement. Consensus was defined as ≥ 70% agreement (score of 7–9) and ≤ 15% disagreement (score of 1–3). Statistical measures such as content validity ratio and Kendall’s coefficient of concordance (W) were calculated to assess agreement levels.
Results:
Of the 46 assessment-related statements, 17 (37%) reached consensus, though overall pre-treatment assessments showed weak agreement (Kendall’s W = 0.319). Key areas of agreement included the use of the visual analogue scale, numeric rating scale, and validated questionnaires for pre-treatment evaluation. Five statements, such as the use of computed tomography, magnetic resonance imaging, and angiography for diagnosing pulsatile tinnitus, achieved over 90% agreement. For treatment outcome measurements, 8 of 12 statements (67%) reached a consensus, with moderate agreement (Kendall’s W = 0.513). Validated questionnaires and psychoacoustic tests were recommended for evaluating treatment effects within 12 weeks. While standardized imaging for pulsatile tinnitus and additional clinical tests were strongly recommended, full consensus was not achieved across all imaging modalities.
Conclusion
This study provides actionable recommendations for tinnitus assessment and treatment evaluation, emphasizing the use of standardized tools and individualized approaches based on patient needs. These findings offer a practical framework to enhance consistency and effectiveness in tinnitus management within Korean clinical settings.
6.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
7.Radiation-Induced Meningiomas Have an Aggressive Clinical Course:Genetic Signature Is Limited to NF2Alterations, and Epigenetic Signature Is H3K27me3 Loss
Tae-Kyun KIM ; Jong Seok LEE ; Ji Hoon PHI ; Seung Ah CHOI ; Joo Whan KIM ; Chul-Kee PARK ; Hongseok YUN ; Young-Soo PARK ; Sung-Hye PARK ; Seung-Ki KIM
Journal of Korean Medical Science 2025;40(18):e62-
Background:
While the clinical course of radiation-induced meningioma (RIM) is considered to be more aggressive than that of sporadic meningioma (SM), the genetic predisposition for RIM is not established well. The present study aimed to analyze the clinical and genetic characteristics of RIMs to increase understanding of the tumorigenesis and prognosis of RIMs. Methods: We investigated a database of 24 patients who met the RIM criteria between January 2000 and April 2023. Genetic analysis through next-generation sequencing with a targeted gene panel was performed on 10 RIM samples. Clinical, radiological, and pathological parameters were evaluated with genetic analyses.
Results:
The median ages for receiving radiotherapy (RT) and RIM diagnosis were 8.0 and 27.5 years, respectively, with an interval of 17.5 years between RT and RIM diagnosis. RIMs tended to develop in non-skull bases and multifocal locations. Most primary pathologies included germ cell tumors and medulloblastoma. The tumor growth rate was 3.83 cm 3 per year, and the median doubling time was 0.8 years. All patients underwent surgical resection of RIMs. The histological grade of RIMs was World Health Organization grade 1 (64%) or 2 (36%). RIMs showed higher incidences in young-age (63%), high-dose (75%), and extendedfield (79%) RT groups. The recurrence rate was 21%. Genetic analysis revealed NF2 one copy loss in 90% of the patients, with truncating NF2 mutations and additional copy number aberrations in grade 2 RIMs. TERT promoter mutation and CDKN2A/B deletion were not identified. Notably, loss of H3K27me3 was identified in 26% of RIMs. H3K27me3 loss was associated with a higher prevalence of grade 2 RIMs (67%) and high recurrence rates (33%).
Conclusion
The study reveals a higher prevalence of high-grade tumors among RIMs with more rapid growth and higher recurrences than SMs. Genetically, RIMs are primarily associated with NF-2 alterations with chromosomal abnormalities in grade 2 tumors, along with a higher proportion of H3K27me3 loss.
9.Effect of Wearing Phospholipid-releasing Contact Lenses on Dry Eyes in Rabbits
Hyeon Jung KIM ; Sehie PARK ; Yun Kyoung RYU ; Jin Sun HWANG ; Sun Hee OH ; Jae Hwi LEE ; Gui Bae KIM ; Young Joo SHIN
Journal of the Korean Ophthalmological Society 2025;66(4):181-190
Purpose:
To investigate whether a new phospholipid-releasing soft contact lens can improve symptoms of dry eyes.
Methods:
The study used 2.5-3.0 kg New Zealand rabbits including both normal non-dry eye rabbits and dry eye rabbits, the latter having undergone electrocauterization of the meibomian glands to block the gland orifices. Each rabbit wore a control contact lens on one eye and a phospholipid-releasing contact lens on the other eye daily. Phospholipid-releasing and control contact lenses were provided by NEOVISION Co., Ltd. The parameters assessed included tear film break-up time, tear osmolarity, ocular surface staining, and central corneal thickness. After the experiment, the rabbits were euthanized and their conjunctival tissue was stained with Periodic Acid Schiff (PAS) to observe conjunctival goblet cells.
Results:
In both dry eye and normal non-dry eye rabbits, tear film break-up time was longer and tear osmolarity was lower when using the phospholipid-releasing contact lens compared to the control contact lens. The ocular surface remained unstained in normal non-dry eye rabbits while staining was observed in dry eye rabbits. There was no significant difference in central corneal thickness between the control and phospholipid-releasing contact lenses in either group. PAS staining showed no difference in conjunctival goblet cell density between the two lens types in normal non-dry eye rabbits. However, in dry eye rabbits, the conjunctival goblet cell density tended to be slightly higher with the phospholipid-releasing contact lens compared to the control lens.
Conclusions
Phospholipid-releasing contact lenses may help reduce dry eye symptoms and minimize contact lens-related complications by stabilizing the tear film and lowering tear osmolarity.
10.Hemicentral Retinal Vein Occlusion: Clinical Outcomes and Visual Prognostic Factors
Dong Woo LEE ; Do Yun SONG ; Mi-Ji KIM ; Yong Wun CHO ; Woong-Sun YOO ; In Young CHUNG
Journal of the Korean Ophthalmological Society 2025;66(2):94-100
Purpose:
To confirm the clinical features of hemicentral retinal vein occlusion and identify predictors of visual outcomes.
Methods:
A retrospective analysis was conducted on patients diagnosed with hemicentral retinal vein occlusion between January 2018 and December 2022 and followed for more than 6 months. Patients underwent intravitreal injections as necessary for intraretinal edema. Visual acuity, central macular thickness, ellipsoid zone damage, and the location of inner retinal layer edema were assessed. Patients were categorized into groups A and group B based on the visual acuity at 6 months.
Results:
In total, 20 eyes were followed, with 15 eyes observed for up to 12 months. Seven patients (35.0%) had diabetes and 11 (55.0%) had hypertension. There was a correlation between poor vision at 6 months and hypertension (p = 0.033). The visual acuity of all patients improved from a logMAR of 0.96 at the initial visit to a logMAR of 0.35 at 6 months (p = 0.005). In the group with good initial visual acuity, there were no significant changes in visual acuity during the follow-up period (p = 0.444). The group with good visual acuity at 6 months had a lower degree of photoreceptor ellipsoid zone disruption compared to the group with poor initial vision, indicating a normal structure (p = 0.015).
Conclusions
During follow-up of patients with hemicentral retinal vein occlusion, overall visual acuity improved over time. Patients with good initial acuity maintained it. Favorable visual outcomes can be expected if the ellipsoid zone has a normal structure at the time of the first examination.

Result Analysis
Print
Save
E-mail