1.Effect of cone beam CT registration versus intraoral scanning registration on implant accuracy in robot-assisted surgery: a study using simulated skull models
Yunxiao WANG ; Yulan WANG ; Shimin YU ; Yaoyu ZHAO ; Yufeng ZHANG ; Qi YAN
Chinese Journal of Stomatology 2025;60(8):857-862
Objective:To compare the effects of using cone beam CT (CBCT) and oral scanning registration on implant positional accuracy during robot-assisted implant surgery, and to provide a basis for selecting the appropriate registration for robot-assisted implant surgical options.Methods:One patient with dentition defect, specifically missing teeth at positions 21 and 26 and having natural teeth adjacent mesially and distally to the edentulous area, who visited the Department of Oral Implantology, School of Hospital of Stomatology Wuhan University in 2024 were selected. Based on reconstructed imaging data, 30 identical jaw models were printed. These models were divided into a CBCT registration group and an intra-oral scanning registration group (15 models per group). An associate chief physician with extensive experience in implant surgery performed preoperative registration using the implant robot and completed the implant surgeries. Postoperative CBCT scans were used to determine the three-dimensional position of the implants. The deviations between the planned implant position and the actual position were evaluated, including deviations at the implantation point, apical point, and angular deviation. The differences between the two groups were compared.Results:The implantation deviation was 0.675 (0.490) mm, apical deviation was (0.680±0.272) mm, and the angular deviation was 0.566°±0.147° in the CBCT registration group, and in the intra-oral scanning registration group, implantation deviation was 0.695 (0.313) mm, apical deviation was (0.667±0.217) mm, and the angular deviation was 0.523°±0.168°. There was no statistically significant error in implant precision between the two groups ( P>0.05). Conclusions:This in vitro experiment found that the use of intra-oral scanning registration in robot-assisted implant surgery can achieve similar implant placement accuracy as CBCT registration.
2.Myeloid cells: key players in tumor microenvironments.
Qiaomin HUA ; Zhixiong LI ; Yulan WENG ; Yan WU ; Limin ZHENG
Frontiers of Medicine 2025;19(2):265-296
Cancer is the result of evolving crosstalk between neoplastic cell and its immune microenvironment. In recent years, immune therapeutics targeting T lymphocytes, such as immune checkpoint blockade (ICB) and CAR-T, have made significant progress in cancer treatment and validated targeting immune cells as a promising approach to fight human cancers. However, responsiveness to the current immune therapeutic agents is limited to only a small proportion of solid cancer patients. As major components of most solid tumors, myeloid cells played critical roles in regulating the initiation and sustentation of adaptive immunity, thus determining tumor progression as well as therapeutic responses. In this review, we discuss emerging data on the diverse functions of myeloid cells in tumor progression through their direct effects or interactions with other immune cells. We explain how different metabolic reprogramming impacts the characteristics and functions of tumor myeloid cells, and discuss recent progress in revealing different mechanisms-chemotaxis, proliferation, survival, and alternative sources-involved in the infiltration and accumulation of myeloid cells within tumors. Further understanding of the function and regulation of myeloid cells is important for the development of novel strategies for therapeutic exploitation in cancer.
Humans
;
Tumor Microenvironment/immunology*
;
Myeloid Cells/immunology*
;
Neoplasms/therapy*
;
Animals
3.Associations between statins and all-cause mortality and cardiovascular events among peritoneal dialysis patients: A multi-center large-scale cohort study.
Shuang GAO ; Lei NAN ; Xinqiu LI ; Shaomei LI ; Huaying PEI ; Jinghong ZHAO ; Ying ZHANG ; Zibo XIONG ; Yumei LIAO ; Ying LI ; Qiongzhen LIN ; Wenbo HU ; Yulin LI ; Liping DUAN ; Zhaoxia ZHENG ; Gang FU ; Shanshan GUO ; Beiru ZHANG ; Rui YU ; Fuyun SUN ; Xiaoying MA ; Li HAO ; Guiling LIU ; Zhanzheng ZHAO ; Jing XIAO ; Yulan SHEN ; Yong ZHANG ; Xuanyi DU ; Tianrong JI ; Yingli YUE ; Shanshan CHEN ; Zhigang MA ; Yingping LI ; Li ZUO ; Huiping ZHAO ; Xianchao ZHANG ; Xuejian WANG ; Yirong LIU ; Xinying GAO ; Xiaoli CHEN ; Hongyi LI ; Shutong DU ; Cui ZHAO ; Zhonggao XU ; Li ZHANG ; Hongyu CHEN ; Li LI ; Lihua WANG ; Yan YAN ; Yingchun MA ; Yuanyuan WEI ; Jingwei ZHOU ; Yan LI ; Caili WANG ; Jie DONG
Chinese Medical Journal 2025;138(21):2856-2858
4.Effect of cone beam CT registration versus intraoral scanning registration on implant accuracy in robot-assisted surgery: a study using simulated skull models
Yunxiao WANG ; Yulan WANG ; Shimin YU ; Yaoyu ZHAO ; Yufeng ZHANG ; Qi YAN
Chinese Journal of Stomatology 2025;60(8):857-862
Objective:To compare the effects of using cone beam CT (CBCT) and oral scanning registration on implant positional accuracy during robot-assisted implant surgery, and to provide a basis for selecting the appropriate registration for robot-assisted implant surgical options.Methods:One patient with dentition defect, specifically missing teeth at positions 21 and 26 and having natural teeth adjacent mesially and distally to the edentulous area, who visited the Department of Oral Implantology, School of Hospital of Stomatology Wuhan University in 2024 were selected. Based on reconstructed imaging data, 30 identical jaw models were printed. These models were divided into a CBCT registration group and an intra-oral scanning registration group (15 models per group). An associate chief physician with extensive experience in implant surgery performed preoperative registration using the implant robot and completed the implant surgeries. Postoperative CBCT scans were used to determine the three-dimensional position of the implants. The deviations between the planned implant position and the actual position were evaluated, including deviations at the implantation point, apical point, and angular deviation. The differences between the two groups were compared.Results:The implantation deviation was 0.675 (0.490) mm, apical deviation was (0.680±0.272) mm, and the angular deviation was 0.566°±0.147° in the CBCT registration group, and in the intra-oral scanning registration group, implantation deviation was 0.695 (0.313) mm, apical deviation was (0.667±0.217) mm, and the angular deviation was 0.523°±0.168°. There was no statistically significant error in implant precision between the two groups ( P>0.05). Conclusions:This in vitro experiment found that the use of intra-oral scanning registration in robot-assisted implant surgery can achieve similar implant placement accuracy as CBCT registration.
5.Study on ultrasonographic diagnosis of complex fetal congenital heart disease in the first trimester
Shuihua YANG ; Mengfeng LIANG ; Guican QIN ; Yan LIANG ; Suli LUO ; Zuojian YANG ; Yulan PANG ; Feiwen LONG ; Yanni TANG ; Guidan HE
Chinese Journal of Ultrasonography 2024;33(1):27-35
Objective:To determine the diagnostic accuracy and prognosis of fetal congenital heart disease (CHD) detected by ultrasound at 11-13 weeks gestation.Methods:Fetuses at 11 to 13 + 6 weeks gestation in the Maternal and Child Health Hospital of Guangxi Zhuang Autonomous Region between January 2015 and December 2022 were prospectively collected. Standrardized ultrasound was used to examine the fetuses. For the suspected fetal CHD, the section of cardiac ultrasound was improved as far as possible, and ultrasonic results, prenatal diagnosis, pathological anatomy and pregnancy outcome were followed up. Results:A total of 539 cases of CHD were detected in 72 242 fetuses with mixed risk in the first trimester, the incidence was 0.75% (539/72 242). The incidence of CHD in the fetuses with positive soft markers was 9.20% (287/3 118), and the incidence of multiple fetal malformations was 16.22% (235/1 449). The diagnostic accordance rate of complex CHD was 97.42%. For complex CHD, the sensitivity, specificity, false positive rate and false negative rate of first-trimester ultrasound were 90.41%, 99.98%, 0.02%, 9.59%. Combined with the results of this study, the abnormal section model of complex CHD was recommended. A total of 252 cases underwent staining chromosomal microarray or gene sequencing, of which 42.46% (107/252) were positive.Conclusions:Standardized ultrasound examination has a very high detection rate for fetal CHD in the first trimester. Transverse scanning of the heart can significantly improve the display of gray scale cardiac section, and reference to the cardiac section pattern map is beneficial to the early diagnosis of fetal CHD.
6.Changes in corneal epithelial thickness and optical density and their correlation after smart pulse technology-assisted transepithelial photorefractive keratectomy
Shiyang NIU ; Hua YANG ; Yan LI ; Zhiqiang DAI ; Xinmin LI ; Yulan ZHOU ; Ouyang ZHANG ; Baojun WANG
International Eye Science 2024;24(8):1308-1313
AIM: To evaluate the changes in corneal epithelial thickness(CET)and corneal optical density(CD)after smart pulse technology(SPT)-assisted transepithelial photorefractive keratectomy(TPRK)and analyze their correlation.METHODS: The prospective study included 60 patients(120 eyes)with myopia and myopic astigmatism who underwent SPT-TPRK in the ophthalmology department at the First Affiliated Hospital of Xinxiang Medical University between February and August 2023. Changes in CET and CD were evaluated preoperatively and at 1 wk, 1 and 3 mo postoperatively.RESULTS: A total of 14 cases(28 eyes)were lost to follow-up, and 3 patients(6 eyes)with postoperative haze were excluded from this study, resulting in a final inclusion of 43 patients(86 eyes). At 1 wk after SPT-TPRK, CET had statistically significantly thickened compared to preoperative levels(P<0.05), particularly in the CET at 0-2 mm central corneal area(P<0.05). At 1 mo after SPT-TPRK, the CET at 0-2 mm area had statistically significantly decreased(P<0.05). At 3 mo after SPT-TPRK, the CET at 0-2 mm had essentially reached preoperative levels. Postoperative CD values increased, with a positive correlation between CET in the 0-2 mm area and CD in the whole 0-2 mm area(r=0.256, P<0.05), and a positive correlation between CET in the 2-5 mm area and CD in the anterior 2-6 mm area(r=0.319, P<0.05).CONCLUSION: Corneal epithelial remodeling takes 3 mo in areas within 2 mm of the central cornea; areas with thinner CET have faster postoperative corneal epithelial remodeling and greater thickening in the early postoperative period; CD increases in the early postoperative period compared to the preoperative value, and in some areas, there is a positive correlation between CET and CD value.
7.Research progress on the correlation between plaque biofilm and peri-implantitis
Journal of Prevention and Treatment for Stomatological Diseases 2024;32(9):730-736
Bacterial overproliferation and virulence factors in plaque biofilms can cause inflammation of soft and hard tissues around the implant, resulting in peri-implantitis. If not well controlled, severe peri-implantitis can lead to failure of implant osseointegration and implant loosening and loss. Currently, peri-implantitis can be treated by surgical and non-surgical treatment such as mechanical debridement and chemotherapy, but there remain problems related to the unpredictable therapeutic effect and high recurrence rate. Therefore, gaining a comprehensive understanding of the relationship between plaque biofilm formation and peri-implantitis is crucial for the prevention and treatment of peri-implantitis. In this article, we comprehensively review current research on the specific composition and formation process of biofilms and the influence of implant material characteristics on biofilm formation. The results of the research review indicated that peri-implantitis biofilms are composed of extracellular matrix, with a predominant population of anaerobic Gram-negative bacteria embedded within. The formation process includes the acquisition of an acquired membrane, microbial adhesion, and biofilm detachment and dispersion. Biofilm formation is primarily influenced by the implant surface roughness, surface free energy (SFE), and material properties. Current strategies for biofilm removal around implants mainly involve implant surface coating techniques, mechanical debridement, chemical agents, laser therapy, and photodynamic therapy; however, the therapeutic outcomes remain uncertain. The future research direction will be based on the characteristics of the plaque biofilm around the implant, combined with cutting-edge methods, such as nanotechnology, immunotherapy, and gene therapy, to continuously prevent the formation of plaque biofilm on the surface of the implant to prevent and treat peri-implantitis.
8.Family resilience mechanisms in children with obstetrical brachial plexus palsy:a qualitative study
Xiaoju ZHANG ; Yulan ZHU ; Pengfei YAN
Modern Hospital 2024;24(11):1776-1779,1785
Objective To explore mechanisms of family resilience in children with obstetrical brachial plexus palsy(OBPP)and provide a basis for developing interventions to family resilience.Methods Semi-structured interviews were conduc-ted with 10 primary caregivers,and data were analyzed through content analysis.Results Three themes were distilled,namely,great impact of the injurious event on the family,positive response of the family to the injurious event,and hidden pain that the injurious event brought to the family.Conclusion The overall resilience of families of OBPP children is in a high level.It is es-sential to address the adverse impact of the injurious event on the families,consolidate the positive results of the family's re-sponse to the injury,and promote the restoration and enhancement of the family's function.
9.Exploration and practice of teaching reform in the course of Engineering Drawing for biomedical engineering major at military medical universities
Da JING ; Zedong YAN ; Tao SUN ; Juan LIU ; Yulan TIAN ; Xiaoming WU ; Kangning XIE
Chinese Journal of Medical Education Research 2024;23(12):1654-1659
Based on the practical issues discovered in the long-duration teaching practice for the course of Engineering Drawing, our teaching team has proposed the "four combinations" reform concept for the Engineering Drawing course of the biomedical engineering major in military medical universities. A distinguished course closely related with biomedical engineering, clinical medicine, and military medicine was successfully established by performing the course teaching reforms from multiple dimensions, including optimizing the curriculum system, improving teaching methods, innovating assessment models, improving textbook construction, promoting teaching condition construction, and strengthening the teaching team competitiveness. We have demonstrated a significant improvement in teaching effectiveness from multiple perspectives, including student classroom enthusiasm, graduation exam scores, student satisfaction with evaluations, and the use of learned knowledge in practical design work. The teaching reform of this course is expected to significantly enhance the interest of biomedical engineering students in the major at military medical universities, and provide practical experience for other related universities to perform subsequent reforms in Engineering Drawing teaching.
10.A multicenter prospective study on early identification of refractory Mycoplasma pneumoniae pneumonia in children
Dan XU ; Ailian ZHANG ; Jishan ZHENG ; Mingwei YE ; Fan LI ; Gencai QIAN ; Hongbo SHI ; Xiaohong JIN ; Lieping HUANG ; Jiangang MEI ; Guohua MEI ; Zhen XU ; Hong FU ; Jianjun LIN ; Hongzhou YE ; Yan ZHENG ; Lingling HUA ; Min YANG ; Jiangmin TONG ; Lingling CHEN ; Yuanyuan ZHANG ; Dehua YANG ; Yunlian ZHOU ; Huiwen LI ; Yinle LAN ; Yulan XU ; Jinyan FENG ; Xing CHEN ; Min GONG ; Zhimin CHEN ; Yingshuo WANG
Chinese Journal of Pediatrics 2024;62(4):317-322
Objective:To explore potential predictors of refractory Mycoplasma pneumoniae pneumonia (RMPP) in early stage. Methods:The prospective multicenter study was conducted in Zhejiang, China from May 1 st, 2019 to January 31 st, 2020. A total of 1 428 patients with fever >48 hours to <120 hours were studied. Their clinical data and oral pharyngeal swab samples were collected; Mycoplasma pneumoniae DNA in pharyngeal swab specimens was detected. Patients with positive Mycoplasma pneumoniae DNA results underwent a series of tests, including chest X-ray, complete blood count, C-reactive protein, lactate dehydrogenase (LDH), and procalcitonin. According to the occurrence of RMPP, the patients were divided into two groups, RMPP group and general Mycoplasma pneumoniae pneumonia (GMPP) group. Measurement data between the 2 groups were compared using Mann-Whitney U test. Logistic regression analyses were used to examine the associations between clinical data and RMPP. Receiver operating characteristic (ROC) curves were used to analyse the power of the markers for predicting RMPP. Results:A total of 1 428 patients finished the study, with 801 boys and 627 girls, aged 4.3 (2.7, 6.3) years. Mycoplasma pneumoniae DNA was positive in 534 cases (37.4%), of whom 446 cases (83.5%) were diagnosed with Mycoplasma pneumoniae pneumonia, including 251 boys and 195 girls, aged 5.2 (3.3, 6.9) years. Macrolides-resistant variation was positive in 410 cases (91.9%). Fifty-five cases were with RMPP, 391 cases with GMPP. The peak body temperature before the first visit and LDH levels in RMPP patients were higher than that in GMPP patients (39.6 (39.1, 40.0) vs. 39.2 (38.9, 39.7) ℃, 333 (279, 392) vs. 311 (259, 359) U/L, both P<0.05). Logistic regression showed the prediction probability π=exp (-29.7+0.667×Peak body temperature (℃)+0.004×LDH (U/L))/(1+exp (-29.7+0.667×Peak body temperature (℃)+0.004 × LDH (U/L))), the cut-off value to predict RMPP was 0.12, with a consensus of probability forecast of 0.89, sensitivity of 0.89, and specificity of 0.67; and the area under ROC curve was 0.682 (95% CI 0.593-0.771, P<0.01). Conclusion:In MPP patients with fever over 48 to <120 hours, a prediction probability π of RMPP can be calculated based on the peak body temperature and LDH level before the first visit, which can facilitate early identification of RMPP.


Result Analysis
Print
Save
E-mail