1.Diagnostic value of exhaled volatile organic compounds in pulmonary cystic fibrosis: A systematic review
Xiaoping YU ; Zhixia SU ; Kai YAN ; Taining SHA ; Yuhang HE ; Yanyan ZHANG ; Yujian TAO ; Hong GUO ; Guangyu LU ; Weijuan GONG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(02):223-229
Objective To explore the diagnostic value of exhaled volatile organic compounds (VOCs) for cystic fibrosis (CF). Methods A systematic search was conducted in PubMed, EMbase, Web of Science, Cochrane Library, CNKI, Wanfang, VIP, and SinoMed databases up to August 7, 2024. Studies that met the inclusion criteria were selected for data extraction and quality assessment. The quality of included studies was assessed by the Newcastle-Ottawa Scale (NOS), and the risk of bias and applicability of included prediction model studies were assessed by the prediction model risk of bias assessment tool (PROBAST). Results A total of 10 studies were included, among which 5 studies only identified specific exhaled VOCs in CF patients, and another 5 developed 7 CF risk prediction models based on the identification of VOCs in CF. The included studies reported a total of 75 exhaled VOCs, most of which belonged to the categories of acylcarnitines, aldehydes, acids, and esters. Most models (n=6, 85.7%) only included exhaled VOCs as predictive factors, and only one model included factors other than VOCs, including forced expiratory flow at 75% of forced vital capacity (FEF75) and modified Medical Research Council scale for the assessment of dyspnea (mMRC). The accuracy of the models ranged from 77% to 100%, and the area under the receiver operating characteristic curve ranged from 0.771 to 0.988. None of the included studies provided information on the calibration of the models. The results of the Prediction Model Risk of Bias Assessment Tool (PROBAST) showed that the overall bias risk of all predictive model studies was high, and the overall applicability was unclear. Conclusion The exhaled VOCs reported in the included studies showed significant heterogeneity, and more research is needed to explore specific compounds for CF. In addition, risk prediction models based on exhaled VOCs have certain value in the diagnosis of CF, but the overall bias risk is relatively high and needs further optimization from aspects such as model construction and validation.
2.Sequencing analysis of whole genome of one strain of bovine Akabane virus and es-tablishment of fluorescence quantitative PCR for virus detection
Jiafu SHANG ; Le HU ; Mingke LI ; Yujian WU ; Xingwei NI ; Xiaowei YANG ; Xia LIU ; Liwu ZHANG ; Tingting XU ; Guangwei ZHAO
Chinese Journal of Veterinary Science 2024;44(9):1872-1881
In order to understand the prevalence of Akabane disease(AKAD)in Guizhou Province and the molecular characteristics of the isolates,the whole-genome sequence of a strain of Akabane virus(AKAV)from a bovine AKAD-positive sample was determined and analyzed.The genotype and genetic variation of the strain were also explored.Based on the conserved S sequence,a fluores-cence quantitative PCR(qPCR)detection method was established and applied for the investigation of AKAV infection status in four large-scale beef cattle farms of Guizhou.Results showed that the S,M and L fragments of the bovine strain were highly homologous to the Tianjin strain(TJ2016/China/2016)and the Australian strain(JaLAB39/Australia/1959),where they were in the same evolutionary branch and belonged to genotype Ⅱ.Sensitivity assay found that the lowest detection limit was 2.5 X 101 copies/μL.Specificity assay showed the established method detected only AKAV with no amplification on bovine bluetongue virus(BLUV),Pasteurella multocida(PM),bovine infectious rhinotracheitis virus(IBRV)and bovine Mycoplasma bovis.The variation coefficients of inter-and intra batches in the repeatability test were both lower than 2.26%.These findings illus-trated that the established qPCR method had high sensitivity,good specificity and repeatability.A total of 298 serum samples from 4 large-scale beef cattle farms in Qianxi City and Huangping County of Guizhou Province were collected and tested for AKAV by the method.Out of 298 sam-ples,25 positive samples(25/298)were detected as positive with a positive rate of 8.39%.In sum-mary,this work provided the reference data for a deep understanding of the molecular prevalence of AKAV in Guizhou Province and laid foundation for the prevention and control of AKAD.
3.Antibody-platinum(Ⅳ)prodrugs conjugates for targeted treatment of cutaneous squamous cell carcinoma
Yin XIANGYE ; Zhuang YINGJIE ; Song HAIQIN ; Xu YUJIAN ; Zhang FAN ; Cui JIANXIN ; Zhao LEI ; Yu YINGJIE ; Zhang QIXU ; Ye JUN ; Chen YOUBAI ; Han YAN
Journal of Pharmaceutical Analysis 2024;14(3):389-400
Antibody-drug conjugates(ADCs)are a new type of targeting antibodies that conjugate with highly toxic anticancer drugs via chemical linkers to exert high specificity and efficient killing of tumor cells,thereby attracting considerable attention in precise oncology therapy.Cetuximab(Cet)is a typical antibody that offers the benefits of good targeting and safety for individuals with advanced and inoperable cutaneous squamous cell carcinoma(cSCC);however,its anti-tumor activity is limited to a single use.Cisplatin(CisPt)shows good curative effects;however,its adverse effects and non-tumor-targeting ability are major drawbacks.In this study,we designed and developed a new ADC based on a new cytotoxic platinum(Ⅳ)prodrug(C8Pt(Ⅳ))and Cet.The so-called antibody-platinum(Ⅳ)prodrugs conjugates,named Cet-C8Pt(Ⅳ),showed excellent tumor targeting in cSCC.Specifically,it accurately delivered C8Pt(Ⅳ)into tumor cells to exert the combined anti-tumor effect of Cet and CisPt.Herein,metabolomic analysis showed that Cet-C8Pt(Ⅳ)promoted cellular apoptosis and increased DNA damage in cSCC cells by affecting the vitamin B6 metabolic pathway in tumor cells,thereby further enhancing the tumor-killing ability and providing a new strategy for clinical cancer treatment using antibody-platinum(Ⅳ)prodrugs conjugates.
4.Digital design and 3D-printed customized flanged cups in hip revision with severe acetabular bone defects
Yujian DING ; Dehong FENG ; Ling WANG ; Yu GUO ; Yi LIU ; Yiyi ZHOU ; Sutong GUO ; Zhengying QIAN ; Kuixue XU ; Zhaofeng ZHANG
Chinese Journal of Orthopaedics 2023;43(2):97-103
Objective:To investigate the effect of 3D-printed customized flanged cup in hip revision with severe acetabular bone defects.Methods:Since February 2017, 10 cases of 3D-printed customized flanged cups were used in hip revision with severe acetabular bone defects, including 2 cases of Paprosky type IIIA and 8 cases of Paprosky type IIIB. There were 5 males and 5 females, mean age 73.6±8.1 yrs (range, 62-87 yrs), 5 left and 5 right cases. The preoperative thin-layer CT scan was preformed to reverse reconstruct digital pelvis. Five cases of one-piece flanged cups and 5 cases of decomposed flanged cups, including 3 cases of composite one-piece cups were designed by computer. The surgery was performed strictly according to the plan.Postoperative follow-up was performed to evaluate the Harris score. Operation time,intraoperative bleeding and other complications such as vascular and nerve injury, postoperative infection, and dislocation were counted. Pelvic X-ray was used to assess the height and horizontal position of the center of rotation and the stability of the prosthesis.Results:The surgical procedure was successful, with an average operative time of 147.9±48.3 min (range, 96-212 min) and an average intraoperative bleeding of 730.4±262.6 ml (range, 500-1 300 ml). The mean time of final follow-up was 40.8±18.7 months (range, 16-70 months) after surgery. At the last follow-up, the average Harris score was 83.80±6.73, with 4 cases excellent, 5 cases good, and 1 case fair. The excellent and good rate was 90%. The last Harris score was significantly higher than that before operation 28.60±8.40 ( t=16.84, P<0.001). The height of affected hip joint rotation center decreased from 46.24±7.74 mm before operation to 15.54±2.54 mm after operation with significant difference ( t=14.61, P<0.001). It was slightly higher than the opposite side (13.81±1.48 mm), which had no significant difference ( t=1.83, P=0.100). The horizontal distance of affected hip joint rotation center increased from 33.79±5.27 mm before operation to 40.53±4.50 mm after operation with significant difference ( t=3.62, P=0.006). It had no significant difference ( t=1.28, P=0.232) compared with the opposite side (38.54±3.46 mm). All incisions were healed in one stage without infection, vascular or nerve injury. During the following-up, all prostheses were in satisfied position without loosening, dislocation or screw breaks. Conclusion:Digitally assisted 3D-printed flanged cups can be used in hip revision with severe acetabular bone defect. It can not only improve hip joint function, but also restore the acetabular rotation center and the prosthesis stability, which can achieve good early and mid-term effect.
5.Effect and necessity of early surgical management of neonatal testicular torsion: an analysis of 11 cases
Hao CHEN ; Yujian DAI ; Xiaogang SUN ; Zhenhua ZHANG ; Chuntian WANG ; Weixiu CHEN ; Ruoyi WANG
Chinese Journal of Perinatal Medicine 2023;26(8):676-680
Objective:To investigate the clinical features of neonatal testicular torsion and to evaluate the effect and necessity of early intervention.Methods:A retrospective analysis was performed on 11 neonates admitted to the Second Hospital of Shandong University with neonatal testicular torsion from June 2017 to June 2022. Clinical data of these cases including clinical manifestations, ultrasonography findings, surgical management and outcomes were reviewed and analyzed with descriptive statistical methods.Results:The median age of the 11 patients on admission was 2.6 d (1-5 d). The median time from finding abnormal scrotum to admission was 12 h (1-120 h). Various degrees of scrotal swelling or scleroma were found in the patients. Among them, seven patients presented with acute inflammatory signs of cyano sis or skin redness, and testis-like tissue induration could be touched. Ultrasound scan showed abnormal blood flow in the affected testicle in all cases. Emergency scrotal exploration under general anesthesia was performed successfully in all cases and ten of them underwent orchiectomy of the affected testicle plus contralateral orchiopexy. The rest one who was admitted within 1 h after birth only underwent orchiopexy of the affected testicle as the parents refused contralateral testicular exploration. During the operation, 12 twisted testis were observed, including seven with extravaginal torsion, three with intravaginal torsion and two adhering to the surrounding tissue without normal testicular tissue or distinguishable torsion direction or degree. In this study, ten patients had unilateral testicular torsion, which affected the left side in seven cases and the right side in three cases, and one had bilateral testicular torsion, which was diagnosed as left testicle torsion before surgery. During scrotal exploration, the left testicle of this bilateral case was resected due to necrosis, while the right testicle twisted about 180 degrees with good blood flow and was subjected to orchidopexy after reduction. In one case, the unaffected testicle was unfixed and dysplastic during contralateral exploration, which was also subjected to orchidopexy. In the 12 testis with torsion, one testicle of the patient admitted within 1 h after birth and the right testicle of the bilateral case were preserved with a salvage rate of 2/12. Pathological examination showed necrosis in the ten excised testis, and fibrosis and calcification foci in two of them. None of the patients had any perioperative complications and the scrotal incision healed well in all neonates. The patients were followed up for 6-12 months with regular ultrasound. The two preserved testis and the contralateral testis subjected to orchidopexy were located in the scrotum with good blood supply, and no torsion, atrophy or other abnormalities occurred.Conclusions:Neonatal testicular torsion is rarely seen in clinical practice and has no specific manifestations. It has a high excision rate due to testicular necrosis. Early diagnosis and bilateral scrotal exploration are crucial to the prognosis and the keys to save the affected testis and avoid anorchidism.
6.Influence of blood donors' coagulation status in apheresis platelet aggregation in vitro
Yujian LIU ; Xiaofan LI ; Qiwen LIN ; Dawei CHEN ; Fanfan FENG ; Huibin ZHONG ; Wenchun ZHANG ; Yongmei NIE
Chinese Journal of Blood Transfusion 2023;36(8):728-731
【Objective】 To investigate whether the blood donors' coagulation status may lead to apheresis platelet aggregation in vitro. 【Methods】 Thirty blood donors with aggregation in apheresis platelets collected by AMICUS blood cell separator no less than 3 times previously and occurred when the last time of apheresis donation were observed in aggregated group (referred to as the experimental group); Thirty donors without aggregation in apheresis platelets collected by AMICUS blood cell separator no less than 3 times were observed in the control group simultaneously. The basic platelet parameters in the two groups, including Plt, MPV, PDW, Pet, P-LCR were detected by automatic blood cell analyzer (BC-3000Plus), and thromboelastogram indexes including reaction time(R), kinetics time(K), kinetics of clot development(α), maximum amplitude (MA) and coagulation index(CI) were tested by Thrombosis elastography (TEG) before collection. With SPSS24.0 software, t test was used to compare the differences between the two groups. 【Results】 The CI value in experimental group was significantly different from that of the control group (0.48± 1.00 vs -0.99 ±1.96, P< 0.05), and there was no significant difference in all above basic platelet parameters and other TEG parameters (P>0.05 ) . 【Conclusion】 The coagulation status of blood donors may be an independent risk factor for the in vitro aggregation of apheresis platelets.
7.A sourceless efficiency calibration method based on the coupling of Monte Carlo simulation and analytical calculation
Zhen WU ; Pengwen SU ; Yujian WANG ; Hui ZHANG ; Rui QIU ; Junli LI
Chinese Journal of Radiological Health 2022;31(4):392-400
Objective To establish a sourceless efficiency calibration method by coupling Monte Carlo simulation with analytical calculation. Methods Monte Carlo simulation was used to calculate the point-to-point detection efficiency of specific detectors to establish a detection efficiency grid. The detection efficiency of point source, disc, cylindrical, beaker, spherical, U-tube and Marlin cup samples was analyzed using numerical integration method after detection efficiency grid interpolation. Results The above coupling method was used for sourceless efficiency calibration. Within the energy range of 0.2–3 MeV, the relative deviation of calibration between coupling method and Monte Carlo simulation was mostly less than 10%, the maximum relative deviation was 18.06%, and the computation time was reduced by at least 86%. The above coupling method was used for sourceless efficiency calibration of an HPGe detector manufactured by ORTEC for point source detection, which was in good agreement with the experimental calibration, and the relative deviations were less than 10%. Conclusion This method can be generalized and used in the sourceless efficiency calibration of HPGe, LaBr3, and NaI detectors.
8.The concept and preliminary practice of precise flap surgery based on CTA
Xiaoqing HE ; Xi YANG ; Jiazhang DUAN ; Xulin ZHANG ; Yujian XU ; Yan SHI ; Yuexian XU ; Yongqing XU
Chinese Journal of Orthopaedics 2022;42(6):365-373
Objective:To introduce the concept and procedure of CTA guided precision flap surgery and report the preliminary clinical application.Methods:The theory of CTA guided precision flap surgery is: based on CTA high-throughput data, comprehensively evaluate the wound and potential donor sites, and select the best plan for wound repair. This article reviews 177 patients treated under the guidance of CTA guided precision flap surgery from August 2014 to December 2018. Among them, 131 were males and 46 were females; they were 7-72 years old, with an average age of 39.5 years. The tissue defects were: 74 cases of foot and ankle, 64 cases of wrist, 15 cases of calf, 11 cases of forearm and upper arm, 7 cases of thigh and perineum, 5 cases of face and neck, and 1 case of abdomen. The size of the defect was 2 cm×1 cm to 65 cm×50 cm. The recipient and donor sites were assessed based on CTA guided precision flap surgery, then choose the optimal flap to repair the defect. The flap types, outcomes and complications were recorded. The visual analogue scale (VAS), British Medical Research Council sensory rating scale, and revascularization assessments of digital replantation standard by Hand Surgery Branch of Chinese Medical Association was used to assess clinical results.Results:All flaps were uneventfully harvested as planned according to the CTA guided precision flap surgery concept.A total number of 181 flaps were harvested, including 125 free flaps and 56 pedicled flaps. The flap area rangedfrom 4 cm×3 cm to 40 cm×8 cm. After surgery, 165 cases were survival completely, 7 cases were total necrosis, 9 cases were partial necrosis. A total of 174 cases of flaps survived. The mean follow-up was 9.2 months (range, 6-60 months). After surgery 53 flaps were bulky, and 7 cases with other complications.At the last follow-up, only 6 patients had mild pain, the VAS score was 1-3. The sensation of the flaps recovered partially. According to the British Medical Research Council sensory rating scale: 68 cases were grade S2 and 106 cases were grade S3. According to the revascularization assessments of digital replantation standard by Hand Surgery Branch of Chinese Medical Association, 171 cases were excellent and 3 cases were good.Conclusion:The concept of precision flap surgery based on CTA can effectively guide flap surgery and achieve precise wound repair.
9.Advances in clinical application of laparoscopic totally extraperitoneal herniorraphy
Yujian ZENG ; Tong ZHANG ; Chengmin SHI ; Zhizhong WU ; Yanqiang SHI ; Huayou LUO
Chinese Journal of Digestive Surgery 2022;21(9):1197-1200
Inguinal hernia is a common surgical disease, and most patients need surgical treatment. In recent years, minimally invasive surgery based on laparoscopy has been popularized in hernia surgery. With the release of clinical guidelines, the progress of instruments and materials, the update of treatment concepts and anatomical knowledge, laparoscopic inguinal hernia repair, especially laparoscopic total extraperitoneal hernia repair (TEP), is developing towards a more accurate and minimally invasive direction. Based on literatures in recent years and combined with clinical practice, the authors explore the advances in clinical application of laparoscopic TEP.
10.Effects of Shuanghuanglian oral liquids on patients with COVID-19: a randomized, open-label, parallel-controlled, multicenter clinical trial.
Li NI ; Zheng WEN ; Xiaowen HU ; Wei TANG ; Haisheng WANG ; Ling ZHOU ; Lujin WU ; Hong WANG ; Chang XU ; Xizhen XU ; Zhichao XIAO ; Zongzhe LI ; Chene LI ; Yujian LIU ; Jialin DUAN ; Chen CHEN ; Dan LI ; Runhua ZHANG ; Jinliang LI ; Yongxiang YI ; Wei HUANG ; Yanyan CHEN ; Jianping ZHAO ; Jianping ZUO ; Jianping WENG ; Hualiang JIANG ; Dao Wen WANG
Frontiers of Medicine 2021;15(5):704-717
We conducted a randomized, open-label, parallel-controlled, multicenter trial on the use of Shuanghuanglian (SHL), a traditional Chinese patent medicine, in treating cases of COVID-19. A total of 176 patients received SHL by three doses (56 in low dose, 61 in middle dose, and 59 in high dose) in addition to standard care. The control group was composed of 59 patients who received standard therapy alone. Treatment with SHL was not associated with a difference from standard care in the time to disease recovery. Patients with 14-day SHL treatment had significantly higher rate in negative conversion of SARS-CoV-2 in nucleic acid swab tests than the patients from the control group (93.4% vs. 73.9%, P = 0.006). Analysis of chest computed tomography images showed that treatment with high-dose SHL significantly promoted absorption of inflammatory focus of pneumonia, which was evaluated by density reduction of inflammatory focus from baseline, at day 7 (mean difference (95% CI), -46.39 (-86.83 to -5.94) HU; P = 0.025) and day 14 (mean difference (95% CI), -74.21 (-133.35 to -15.08) HU; P = 0.014). No serious adverse events occurred in the SHL groups. This study illustrated that SHL in combination with standard care was safe and partially effective for the treatment of COVID-19.
COVID-19
;
Humans
;
Medicine, Chinese Traditional
;
Research
;
SARS-CoV-2
;
Treatment Outcome

Result Analysis
Print
Save
E-mail