1.Analysis of polonium-210 activity concentration in seafood from eastern coastal areas of China and its dose assessment
Ziyuan HE ; Liangliang YIN ; Yuhan XIE ; Yanqin JI
Chinese Journal of Radiological Health 2026;35(3):349-353
Objective To establish an alpha spectrometric method for the analysis of polonium-210 (210Po) in seafood, determine the activity concentration of 210Po in seafood from China’s eastern coastal areas, and assess the corresponding radiation doses. Methods A total of 21 types of seafood belonging to four categories (fish, shrimp, crab, and shellfish) were collected from eastern coastal cities in China. The activity concentration of 210Po in different tissues of the seafood was analyzed using the 209Po tracer-α spectrometry method. The annual effective dose was then estimated by combining seafood consumption rates and dose conversion factors. Results The activity concentrations of 210Po in the edible parts of fish, shrimp, and shellfish samples ranged from 0.65 to 17.89 Bq/kg, 0.81 to 5.95 Bq/kg, and 0.73 to 44.09 Bq/kg, respectively. In whole crab samples, the range was 1.77 to 11.43 Bq/kg. The activity concentration of 210Po in crab samples (whole crab) ranged from 1.77 to 11.43 Bq/kg. 210Po activity was mainly enriched in the head, internal organs, and shell. The annual effective ingestion dose for different age groups ranged from 91.39 to 251.33 μSv/a. Conclusion The annual effective dose resulting from 210Po ingestion via seafood consumption for residents in China’s eastern coastal regions is lower than the annual effective dose reference level recommended by the IAEA.
3.Determining radioactivity concentration of carbon-14 in seafood using a tube combustion system (or oxygen bomb combustion devices) coupled with liquid scintillation counting
Yuxin QIAN ; Yuhan XIE ; Cen SHI ; Yanqin JI
Chinese Journal of Radiological Medicine and Protection 2025;45(9):892-897
Objective:To develop a method for determining 14C in seafood using a tube combustion furnace (or oxygen bomb combustion devices) coupled with liquid scintillation counting (LSC), in order to accurately determine 14C in seafood. Methods:Four categories of seafood samples (i.e., fish, crustaceans, mollusks, and algae) were collected. They were then subjected to high-temperature oxidation using a tube combustion furnace or oxygen bomb combustion devices to isolate CO 2, followed by an analysis of the radioactivity concentration of 14C using LSC. The combustion conditions were optimized by investigating the heating nodes and rates in the oxidation combustion furnace, and the CO 2 collection conditions were optimized by placing a NaOH absorption solution in the oxygen bomb combustion devices. Additionally, the optimal measurement conditions were determined by comparing the effects of varying scintillation cocktails and the dark adaptation time of two preparation methods, i. e., the adsorption and suspension method. Results:When a tubular combustion furnace was used for oxidation and combustion, the optimal heating rate of the sample pyrolysis temperature zone was determined at 1.5℃/min. In this case, the combustion efficiency of various seafood could reach over 95%. When the oxygen bomb combustion devices were employed, placing NaOH solutions both inside and at the exhaust end increased absorption efficiency by 10% compared to the traditional practice of placing a NaOH solution only at the exhaust end. Samples prepared using the absorption method should be kept in the dark for at least 10 h before measurement using LSC, while samples prepared with the suspension methods should be kept for at least 20 h. The results obtained using two preprocessing devices and two sample preparation method were consistent, with a detection limit of 9.10 Bq/kg (dry samples). Compared to the suspension method (The relative standard deviation of the results obtained by two preprocessing devices were 9.00% and 8.27%), the absorption method (the corresponding relative standard deviation were 3.61% and 3.29%) exhibited higher precision in repeated measurements.Conclusions:The aforementioned pretreatment devices and sample preparation method are suitable for determining 14C in seafood.
4.Treatment of pulmonary diseases in children from the lung collaterals′ structure, function and pathogenesis
Zhiyuan LU ; Yuhan WANG ; Qigang DAI ; Lili LIN ; Tong XIE ; Shouchuan WANG
Journal of Beijing University of Traditional Chinese Medicine 2025;48(3):323-329
The lung collaterals form a network that branches from the lung meridian, traversing the lung system and extending across the body′s surface. Lung collateral disease refers to the structural alterations or dysfunction in these collaterals caused by external or internal pathogens. Research into the structural and physiological functions of children′s lung collaterals, as well as the pathogenesis and syndrome differentiation for treating lung collateral diseases in children, holds significant value in guiding the prevention and treatment of pediatric respiratory conditions. Drawing on the theory of collateral disease, the clinical insights of both historical and contemporary physicians, and modern research findings—while considering the unique physiological and pathological characteristics of children′s respiratory systems—this study provides a foundational summary of the morphology and spatial distribution of children′s lung collaterals. The characteristics of these collaterals are highlighted as thin, sparse, short, narrow, brittle, and tender. From this structural understanding, the unique physiological functions of children′s lung collaterals are analyzed. The study further explores the interactions between pathogenic factors and lung collaterals, elucidating the pathogenesis and progression of children′s lung collateral diseases. It proposes treatment principles centered on "seeking treatment in the collaterals and employing the method of unblocking collaterals, "which align with the unique features of pediatric lung collaterals. Common treatment approaches, and relevant prescriptions for managing these diseases are summarized. This paper lays the foundation for a theoretical system encompassing the structure, function, pathogenesis, and syndrome differentiation for treating children′s lung collateral diseases. It offers valuable insights for the clinical diagnosis and management of pediatric respiratory diseases linked to collateral dysfunction and serves as a reference for the systematic development of a broader theoretical framework for children′s collateral diseases.
5.Application and optimization of HDEHP extraction chromatography in the determination of strontium-90 in seafood
Cen SHI ; Yuhan XIE ; Yuxin QIAN ; Yanqin JI
Chinese Journal of Radiological Health 2025;34(2):231-236
Objective To evaluate the environmental radioactive safety level in China, monitor the radioactivity of strontium-90 (90Sr) in seafood from selected marine regions of China, and optimize the di-(2-ethylhexyl)phosphoric acid (HDEHP) extraction chromatography method for determining Sr-90 in seafood. Methods In 2023, seafoods of fish, shrimp, shellfish, and seaweed were collected from the Shandong Province (Bohai Sea and Yellow Sea) and Hainan Province (South China Sea). The levels of Sr in the samples were determined by inductively coupled plasma atomic emission spectrometer (ICP-AES). The 90Sr separation were performed using HDEHP extraction chromatography, while the recovery of 90Sr were determined by the gravitmetry with the assistant of ICP-AES. Results The content of strontium in seafoods varies greatly, and excessive strontium and calcium in seafood may lead to overestimated recovery due to insufficient leaching during chromatographic separation by HDEHP extraction. Therefore, the yttrium content in the eluent should be analyzed by ICP . The radioactivity of 90Sr in seafood from the sea areas in Shandong Province was 0.22-1.85 Bq/kg (dry weight), and that of seafood from Hainan Province was 0.19-1.82 Bq/kg (dry weight). Conclusion For the analysis of shirmp and seaweed samples, the recovery rate of 90Sr should be analyzed using both gravimetry and ICP-AES. There is no significant linear correlation between total Sr and 90Sr in seafood. There is no significant difference in 90Sr radioactivity between the seafood samples collected from Shandong and Hainan. The 90Sr radioactivity levels of all 28 samples are below the limit specified in the Limited concentrations of radioactive materials in foods (GB 14882—1994) and are within the range of environmental background fluctuations.
6.Analysis of the 2023 national interlaboratory comparison for measurement of gross α and gross β radioactivity in water
Liangliang YIN ; Yuhan XIE ; Yuxin QIAN ; Cen SHI ; Yanqin JI
Chinese Journal of Radiological Health 2025;34(2):237-241
Objective To organize a nationwide interlaboratory comparison for measurement of gross α and gross β radioactivity in water, and improve the laboratory analysis of gross α and gross β radioactivity in water. Methods A unified comparison protocol was developed by the organizers. The groundwater with high natural radioactivity was used as water sample and distributed randomly to the participating laboratories. The participating laboratories used routine analytical methods to measure the samples and provided information such as analytical results, original records, and test reports. The results were evaluated using z-score. Results A total of 76 laboratories participated in the comparison, all employing the evaporation concentration-α/β counting method. Among them, 69 laboratories achieved |z| ≤ 2 for both gross α and gross β radioactivity measurements, and 32 laboratories achieved |z| ≤ 0.50 for both gross α and gross β radioactivity measurements. There were 69 laboratories with qualified results and 30 laboratories with excellent results, yielding a qualified rate of 90.8% and an excellent rate of 39.5%. Seven laboratories showed unqualified results and the unqualified rate was 9.2%. Conclusion Most laboratories have the ability to analyze gross α and gross β radioactivity in water. The main reasons for the deviation in comparison results are calibration efficiency, errors in the total residue mass caused by improper water sample processing operations. By analyzing the main technical problems existed in unqualified laboratories, their ability for measurement of gross α and gross β radioactivity in water has been improved.
7.Determining radioactivity concentration of carbon-14 in seafood using a tube combustion system (or oxygen bomb combustion devices) coupled with liquid scintillation counting
Yuxin QIAN ; Yuhan XIE ; Cen SHI ; Yanqin JI
Chinese Journal of Radiological Medicine and Protection 2025;45(9):892-897
Objective:To develop a method for determining 14C in seafood using a tube combustion furnace (or oxygen bomb combustion devices) coupled with liquid scintillation counting (LSC), in order to accurately determine 14C in seafood. Methods:Four categories of seafood samples (i.e., fish, crustaceans, mollusks, and algae) were collected. They were then subjected to high-temperature oxidation using a tube combustion furnace or oxygen bomb combustion devices to isolate CO 2, followed by an analysis of the radioactivity concentration of 14C using LSC. The combustion conditions were optimized by investigating the heating nodes and rates in the oxidation combustion furnace, and the CO 2 collection conditions were optimized by placing a NaOH absorption solution in the oxygen bomb combustion devices. Additionally, the optimal measurement conditions were determined by comparing the effects of varying scintillation cocktails and the dark adaptation time of two preparation methods, i. e., the adsorption and suspension method. Results:When a tubular combustion furnace was used for oxidation and combustion, the optimal heating rate of the sample pyrolysis temperature zone was determined at 1.5℃/min. In this case, the combustion efficiency of various seafood could reach over 95%. When the oxygen bomb combustion devices were employed, placing NaOH solutions both inside and at the exhaust end increased absorption efficiency by 10% compared to the traditional practice of placing a NaOH solution only at the exhaust end. Samples prepared using the absorption method should be kept in the dark for at least 10 h before measurement using LSC, while samples prepared with the suspension methods should be kept for at least 20 h. The results obtained using two preprocessing devices and two sample preparation method were consistent, with a detection limit of 9.10 Bq/kg (dry samples). Compared to the suspension method (The relative standard deviation of the results obtained by two preprocessing devices were 9.00% and 8.27%), the absorption method (the corresponding relative standard deviation were 3.61% and 3.29%) exhibited higher precision in repeated measurements.Conclusions:The aforementioned pretreatment devices and sample preparation method are suitable for determining 14C in seafood.
8.Research progress on nurses' knowledge, attitude and practice and associated factors concerning patient-controlled analgesia for cancer pain
Qiaozhen XIANG ; Shulan YANG ; Lingfang XIE ; Yanfang LI ; Yilong YANG ; Yuhan LIN
Chinese Journal of Geriatrics 2024;43(7):828-833
Pain is one of the most common and unendurable symptoms in cancer patients and a major factor affecting their quality of life.Patient-controlled analgesia(PCA) is an important palliative measure in additional to conventional pharmacological control of pain.Nurses play the primary role in the management of PCA for cancer pain, and their knowledge, attitude and practice about PCA for cancer pain directly affect the effectiveness of cancer pain management.This article summarizes and analyzes the current status of nurses' knowledge, attitude and practice and associated influencing factors, aiming to improve nursing management of PCA, reinforce specialized nursing training, propose recommendations for an expert consensus on PCA for cancer pain and provide a reference for nursing practice in PCA for cancer pain.
9.Effect of HES5 on transdifferentiation and apoptosis of renal tubular epithelial cells and its underlying mechanism
Yuhan ZHANG ; Xue HENG ; Lin ZHU ; Pan XIE ; Guilian XU ; Kanfu PENG
Journal of Army Medical University 2024;46(11):1214-1225
Objective To investigate the effect of hairy and enhancer of split 5(HES5)on transdifferentiation and apoptosis of renal tubular epithelial cells induced by TGF-β1 and its potential mechanism.Methods The differentially expressed genes in GSE66494 data were analyzed and screened.The mouse model of unilateral uretera obstruction(UUO)was established,and the expression level of HES5 was detected in the renal tissue.HK-2 cells were treated with 10 ng/mL TGF-β1 for 24 h to establish a tubular epithelial-mesenchymal transition(EMT)model,and then qRT-PCR and Western blotting were performed to detect the expression of HES5 at mRNA and protein levels.After HK-2 cells were transfected with the plasmid overexpressing HES5,the protein levels of fibronectin,collagen Ⅰ,vimentin,apoptosis markers Bax and Bcl2 were detected in 24 h later.Then,HK-2 cells were divided into Control group,siHES5 group,TGF-β 1 group,and siHES5+TGF-β1 group.The protein level of fibrosis and apoptosis markers were measured in above groups with Western blotting.TUNEL staining and flow cytometry were employed to detect cell apoptosis.Western blotting was applied to determine the protein levels of AKT,p-AKT,PI3K and p-PI3K.HK-2 cells overexpressing HES5 were treated with PI3K inhibitor LY294002,and the expression of vimentin was detected.Results The expression of HES5 was significantly up-regulated in both chronic kidney disease(CKD)and fibrotic kidneys of mice.Overexpression of HES5 promoted the synthesis of fibronectin,collagen Ⅰ,vimentin and Bax in HK-2 cells,and inhibited the expression of Bcl2(P<0.05).HES5 knockdown not only down-regulated the expression of fibrosis markers,but also inhibited the apoptosis of HK-2 cells.Furthermore,HES5 knockdown inhibited the activation of PI3K/AKT signaling pathway induced by TGF-β1 in HK-2 cells(P<0.05).Inhibitors of the PI3K/AKT signaling pathway inhibitor attenuated the induction of HES5 on vimentin.Conclusion HES5 knockdown inhibits the transdifferentiation and apoptosis in TGF-β1-induced renal tubular epithelial cells,which may be related to the decreased activity of the PI3K/AKT signaling pathway.
10.Analysis of image quality based on different imaging algorithms of the Ethos adaption radiotherapy system
Xiaoyu LIU ; Yuhan KOU ; Changxin YAN ; Jinyuan WANG ; Peichao BAN ; Dandan ZHANG ; Kaiwen CHEN ; Chuanbin XIE
China Medical Equipment 2024;21(11):1-6
Objective:To quantitatively analyze the differences in image quality and generated synthetic-computed tomography(sCT)between cone beam CT(CBCT)and iteration CBCT(iCBCT),which based on filtered back projection(FBP)and iterative reconstruction(IR)techniques of Varian Ethos adaption system.Methods:Using the special Catphan604 phantom of the test of CT image quality,five times of scanning series of CBCT and iCBCT were respectively performed based on thoracic and abdominal scanning protocols,so as to obtain four sets of images,and each set of image included the CBCT image,the composited sCT and iCBCT images based on CBCT,the composited sCT bases on iCBCT.The noise power spectrum(NPS),image uniformity(UI),modulation transfer function(MTF),low-contrast visibility(LCV)and contrast-to-noise ratio(CNR)of them were analyzed.Additionally,a retrospective analysis was conducted on images of six patients who underwent clinical radiotherapy,and the images of them were obtained by using thoracic and abdominal scanning protocols.The sCT images,which were generated by deformable registrations on the basis of CBCT and iCBCT,were analyzed,and they were compared with located CT images,and their mean absolute error(MAE)and root mean square error(RMSE)were further quantitatively analyzed.Results:Compared to CBCT,iCBCT significantly reduced NPS(thoracic images reduced by 0.08,abdominal images reduced by 0.06).The UI values of thoracic images and abdominal images of iCBCT were respectively 0.37 and 0.28,and those of CBCT were respectively 0.65 and 0.39.The LCV values of thoracic images and abdominal images of iCBCT were respectively 0.67 and 0.56,and those of CBCT were respectively 0.93 and 0.90.The MTF50%were 0.28 lp/mm except abdominal image of iCBCT was 0.29 lp/mm.The resolution rate of high contrast between iCBCT and CBCT was basic consistency.The differences of similarity analysis of the generated sCT and located CT bases on CBCT and iCBCT was no significant(P>0.05).Conclusion:The image quality of iCBCT is superior to conventional CBCT.The accuracy of CT value of generated sCT bases on CBCT and iCBCT can meet requirement,and both of them can be used in the dose calculation of adaptive radiotherapy.


Result Analysis
Print
Save
E-mail