1.The clinical effect of three dimensional print guided F/B-TEVAR vascular endoluminal repair of anastomotic leaks after open surgery for type A aortic dissection
Yu ZHOU ; Yuexue HAN ; Jianhang HU ; Tao TANG ; Lili SUN ; Wendong LI ; Nan HU ; Chen LIU ; Jun SHAO ; Hao YU ; Zhao LIU
Chinese Journal of Surgery 2025;63(9):836-841
Objective:To evaluate the clinical value of three-dimensional(3D) printing-assisted fenestrated/branched endovascular aortic repair (F/B-TEVAR) for the treatment of endoleak after open surgery for type A aortic dissection.Methods:A multi-center retrospective case series analysis was conducted on 16 patients with anastomotic leakage following Stanford type A aortic dissection open repair, admitted to 12 medical centers between January 2019 and December 2023. All surgeries were led by the vascular surgery team from Department of Vascular Surgery, Nanjing Drum Tower Hospital. The study included 12 males and 4 females, with an age of (58.1±8.2) years (range: 42 to 75 years). Preoperative patient-specific 3D-printed models or 3D parametric surface topological guides were created based on aortic CT angiography data. These models assisted intraoperative external positioning of fenestration sites, combined with stent diameter selection and inner branch techniques to complete endovascular repair. Surgical procedures, complications, and clinical outcomes were evaluated, with follow-up CT imaging to assess efficacy.Results:All patients successfully underwent surgery without conversion to open repair. One patient had distal stent migration from a prior open repair, requiring intraoperative coverage of the main stent window and conversion to an in situ fenestration procedure. The mean operative time was (332.6±111.2)minutes (range: 80 to 460 minutes). No renal failure, paraplegia, or branch artery loss occurred. Postoperative follow-up ( M(IQR)) was 18(18) months(range: 6 to 36 months), with follow-up rates of 16/16 at 6 months, 10/16 at 12 months, 8/16 at 24 months, and 2/16 at 36 months. During follow-up, endoleak occurred in 3 patients, cerebral infarction in 1 patient, and death in 1 patient. The remaining patients demonstrated stable stent positioning, patent branches, and no endoleak. Conclusion:3D technology-guided F/B-TEVAR shows favorable mid-to short-term outcomes in treating anastomotic leakage after open repair of type A aortic dissection.
2.The clinical effect of three dimensional print guided F/B-TEVAR vascular endoluminal repair of anastomotic leaks after open surgery for type A aortic dissection
Yu ZHOU ; Yuexue HAN ; Jianhang HU ; Tao TANG ; Lili SUN ; Wendong LI ; Nan HU ; Chen LIU ; Jun SHAO ; Hao YU ; Zhao LIU
Chinese Journal of Surgery 2025;63(9):836-841
Objective:To evaluate the clinical value of three-dimensional(3D) printing-assisted fenestrated/branched endovascular aortic repair (F/B-TEVAR) for the treatment of endoleak after open surgery for type A aortic dissection.Methods:A multi-center retrospective case series analysis was conducted on 16 patients with anastomotic leakage following Stanford type A aortic dissection open repair, admitted to 12 medical centers between January 2019 and December 2023. All surgeries were led by the vascular surgery team from Department of Vascular Surgery, Nanjing Drum Tower Hospital. The study included 12 males and 4 females, with an age of (58.1±8.2) years (range: 42 to 75 years). Preoperative patient-specific 3D-printed models or 3D parametric surface topological guides were created based on aortic CT angiography data. These models assisted intraoperative external positioning of fenestration sites, combined with stent diameter selection and inner branch techniques to complete endovascular repair. Surgical procedures, complications, and clinical outcomes were evaluated, with follow-up CT imaging to assess efficacy.Results:All patients successfully underwent surgery without conversion to open repair. One patient had distal stent migration from a prior open repair, requiring intraoperative coverage of the main stent window and conversion to an in situ fenestration procedure. The mean operative time was (332.6±111.2)minutes (range: 80 to 460 minutes). No renal failure, paraplegia, or branch artery loss occurred. Postoperative follow-up ( M(IQR)) was 18(18) months(range: 6 to 36 months), with follow-up rates of 16/16 at 6 months, 10/16 at 12 months, 8/16 at 24 months, and 2/16 at 36 months. During follow-up, endoleak occurred in 3 patients, cerebral infarction in 1 patient, and death in 1 patient. The remaining patients demonstrated stable stent positioning, patent branches, and no endoleak. Conclusion:3D technology-guided F/B-TEVAR shows favorable mid-to short-term outcomes in treating anastomotic leakage after open repair of type A aortic dissection.
3.3D print-guided fenestration/branch stent treatment of abdominal aortic disease: a national multicenter retrospective study
Yuexue HAN ; Yi JIN ; Dongsheng FU ; Jianhang HU ; Jianfeng DUAN ; Lili SUN ; Mian WANG ; Hao YU ; Yiming SU ; Zhengdong HUA ; Zhidan CHEN ; Shikui GUO ; Zhaohui HUA ; Xiaoqiang LI ; Zhao LIU
Chinese Journal of General Surgery 2024;39(7):527-533
Objective:To study the application of 3D printing technology in multi-center fenestrated/branched endovascular repair (F/B-EVAR) for endovascular repair of abdominal aortic diseases.Methods:From Feb 2018 to Mar 2023, The clinical and followup data of 316 cases of abdominal aortic lesions undergoing repair with F/B-EVAR at 69 medical centers nationwide using 3D printing technology to guide physician-modified stent graft were retrospectively analyzed.Results:The mean follow-up time of the patients was 23 months (2-60 months), and 24 cases were lost to follow up, the follow-up rate was 92.4% (292/316), the mean postoperative hospitalization time was (8.2±4.9) days. A total of 944 main abdominal branch arteries were reconstructed. Intraoperative reconstruction of 11 branches failed, with a success rate of 98.8% (933/944). Within 30 days after surgery, 8 patients died (2.5%), and 6 patients died during follow-up, a total of 14 patients died (4.4%). There were 11 cases (3.5%) of spinal cord ischemia and no patient suffered from permanent paraplegia. There were 19 patients (6.0%) with postoperative renal function injury. Internal leakage was found in 26 patients, and the rate of internal leakage was 8.2%.Conclusion:3D printing technology can accurately locate the location of branch arteries, simplifing the surgical process, shortening the learning curve , and improving clinical efficacy.
4.Risk factors of postoperative complications after fenestrated /branched TEVAR for aortic arch lesions: a multicenter retrospective analysis
Yuexue HAN ; Zhao LIU ; Chen LIU ; Wendong LI ; Nan HU ; Jianhang HU ; Yu ZHOU ; Jianfeng DUAN ; Lili SUN ; Hao YU ; Yiming SU ; Zhengdong HUA ; Zhidan CHEN ; Zhaohui HUA ; Xiaoqiang LI
Chinese Journal of General Surgery 2024;39(9):667-672
Objective:To review the risk factors for early and medium-term complications of fenestration-branch endovascular thoracic aortic repair (F/B-TEVAR) in patients with complex aortic arch disease.Methods:The clinical and follow-up data of 202 patients undergoing F/B-TEVAR treatment from Feb 2019 to Sep 2023 in these centers were retrospectively analyzed .Results:There were 46 cases suffering from postoperative complications (22.8%). The risk factors with statistical significance included aortic atherosclerotic plaque [ OR=2.843; 95% CI (1.4-5.6); P<0.01], aortic intramural thrombosis [ OR=2.358; 95% CI (1.2-4.6), P=0.011], the aortic dilatation [ OR=4.219; 95% CI (1.6-11.3), P<0.01], the history of stroke [ OR=2.088; 95% CI (1.1-4.1), P=0.032], smoking history [ OR=2.680; 95% CI: (1.3-5.5); P<0.01], duration of surgery [ OR=1.9; 95% CI: (1.2-2.9); P=0.042].While the application of 3D printing assistive technology [ OR=0.392; 95% CI: (0.2-0.9); P=0.048] was in a negative correlation with postoperative complication. Conclusions:The independent risk factors for complications after F/B-TVAR included aortic atherosclerotic plaque, aortic intramural thrombosis, the aortic dilatation, the history of stroke, smoking history,duration of surgery.The application of 3D printing technology can effectively reduce the complication rate.
5.Research progress on risk factors associated with postoperative complications of endovascular repair for abdominal aortic aneurysms
Yuzhu WANG ; Shuai ZHANG ; Yu ZHOU ; Yi JIN ; Zihe ZHAO ; Chaohui PAN ; Dongsheng FU ; Yuexue HAN ; Jianhang HU ; REYAGULI·KEYOUMU ; Zhao LIU ; Xiaoqiang LI
Chinese Journal of General Surgery 2024;33(12):2077-2082
Endovascular Aneurysm Repair (EVAR) has become an important treatment method for abdominal aortic aneurysms due to its advantages of shorter operative time,faster postoperative recovery,and lower early postoperative mortality. However,the incidence of complications and the postoperative reintervention rates are higher than those of open surgery. The main complications after EVAR include access vessel injury,post-implantation syndrome,stent migration,endoleaks,visceral branch artery occlusion,lower limb ischemia,and stent infection,which are also the primary causes of reintervention. In recent years,the causes and associated risk factors of various postoperative complications of EVAR have attracted widespread attention and discussion,which are of great significance for improving surgical techniques,enhancing postoperative monitoring,and improving patient outcomes. This paper provides a review of the current complications,associated risk factors,and management strategies after EVAR.
6.Research progress on risk factors associated with postoperative complications of endovascular repair for abdominal aortic aneurysms
Yuzhu WANG ; Shuai ZHANG ; Yu ZHOU ; Yi JIN ; Zihe ZHAO ; Chaohui PAN ; Dongsheng FU ; Yuexue HAN ; Jianhang HU ; REYAGULI·KEYOUMU ; Zhao LIU ; Xiaoqiang LI
Chinese Journal of General Surgery 2024;33(12):2077-2082
Endovascular Aneurysm Repair (EVAR) has become an important treatment method for abdominal aortic aneurysms due to its advantages of shorter operative time,faster postoperative recovery,and lower early postoperative mortality. However,the incidence of complications and the postoperative reintervention rates are higher than those of open surgery. The main complications after EVAR include access vessel injury,post-implantation syndrome,stent migration,endoleaks,visceral branch artery occlusion,lower limb ischemia,and stent infection,which are also the primary causes of reintervention. In recent years,the causes and associated risk factors of various postoperative complications of EVAR have attracted widespread attention and discussion,which are of great significance for improving surgical techniques,enhancing postoperative monitoring,and improving patient outcomes. This paper provides a review of the current complications,associated risk factors,and management strategies after EVAR.

Result Analysis
Print
Save
E-mail