1.Risk of chronic kidney disease in the population aged 60 and above with hypertension and diabetes in Nanjing based on LASSO-logistic regression model
Yucheng HUANG ; Caihong HU ; Huiqing XU ; Ruikang CHEN ; Guofeng AO ; Zhiyong WANG
Journal of Public Health and Preventive Medicine 2026;37(1):98-102
Objective To construct a prediction model for the population with hypertension and diabetes to assess the risk of chronic kidney disease (CKD), and to provide a scientific basis for formulating targeted CKD prevention and control measures. Methods Based on physical examination data from community residents aged 60 years and above in Nanjing in 2022, 10 221 patients with hypertension and diabetes were selected as the study subjects. Variables associated with CKD prevalence were screened using univariate analysis, and further variable selection was performed using LASSO regression. Finally, a CKD risk prediction model was constructed based on logistic regression. The model's performance was evaluated using the ROC curve and calibration curve. Results The prevalence rate of CKD in the study population was 22.71%, with a mean age of 71.66 years. LASSO regression identified seven variables associated with CKD: age, blood urea nitrogen (BUN), hemoglobin, uric acid, triglyceride-glucose (TyG) index, urine protein-to-creatinine ratio (UPCR), and medical insurance type. The final logistic regression model incorporated six variables: age [OR=1.067 (95% CI: 1.058-1.076)], BUN [OR=1.377 (95% CI: 1.338-1.418)], hemoglobin [OR=0.992 (95% CI: 0.989-0.995)], uric acid [OR=1.004 (95% CI: 1.003-1.004)], TyG index [OR=1.445 (95% CI: 1.324-1.577)], and self-payment medical insurance [OR=1.732 (95% CI: 1.542-1.945)]. The model had an AUC of 0.759 (95% CI: 0.747-0.770) and a Brier score of 0.140 (95% CI: 0.136-0.145), indicating good predictive performance. The calibration curve showed good agreement between the predicted risk and the observed value. Conclusion The constructed LASSO-logistic regression risk prediction model in this study can effectively assess the risk of CKD in elderly individuals aged 60 years and above with hypertension and diabetes, providing a basis for early identification of high-risk individuals and the formulation of targeted CKD prevention and control measures.
2.Pinelliae Rhizoma and Its Prescription Compatibility for Depression Treatment: A Review
Zhe XIE ; Yifan SHI ; Linzhe SU ; Ming BAI ; Yucheng LI ; Baoying WANG ; Erping XU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(9):284-293
Depression is a common mental disorder that falls under the category of "stagnation syndrome" in traditional Chinese medicine (TCM). Its complex pathogenesis poses challenges for the development of novel therapeutic agents. Currently, clinically used antidepressants are often accompanied by significant side effects, and statistics show that about one-third of patients do not respond to these medications. TCM demonstrates advantages in the treatment of depression through multi-target, multi-pathway and multi-mechanistic approaches. Pinelliae Rhizoma, a phlegm-resolving herb, exhibits effects such as drying dampness and resolving phlegm, as well as eliminating stuffiness and reducing masses. The characteristics of harmonizing Yin and Yang and resolving stagnation in the middle energizer align precisely with the pathogenesis of depression syndrome, demonstrating therapeutic efficacy in affected patients. Literature studies have found that the active ingredients of Pinelliae Rhizoma, such as cavidine, baicalein, β-sitosterol, as well as Pinelliae Rhizoma herb pairs, such as Pinelliae Rhizoma-Magnoliae Officinalis Cortex, Pinelliae Rhizoma-husked sorghum, Pinelliae Rhizoma-Prunellae Spica, exhibit significant antidepressant effects. Furthermore, TCM formulas containing Pinelliae Rhizoma as the principal therapeutic agent, such as Banxia Xiexin Tang, Banxia Houpo Tang, and Wendan Tang, as well as formulas incorporating Pinelliae Rhizoma like compound Xiaochaihu Tang, Chaihu Jia Longgu Muli Tang, and Erchen Tang, have also demonstrated favorable antidepressant efficacy. The antidepressant mechanism of these agents may involve modulation of 5-hydroxytryptamine (5-HT) and dopamine (DA) levels, up-regulation of brain-derived neurotrophic factor (BDNF) expression, regulation of the hypothalamus-pituitary-adrenal (HPA) axis, reduction of oxidative stress, modulation of nuclear transcription factor-κB (NF-κB) signaling pathway, and inhibition of microglia-mediated inflammatory responses. This review summarized the antidepressant mechanisms and clinical applications of the active components, herb pairs, and TCM formulas containing Pinelliae Rhizoma, aiming to provide a reference for modern research on the use of Pinelliae Rhizoma in antidepressant therapy.
3.Prevalence and associated factors of work-related musculoskeletal disorders among workers in a manganese enterprise
Tianzi SHAN ; Junxiang MA ; Tian CHEN ; Kang NONG ; Yucheng SUN ; Xueting WANG ; Gaoman ZHANG ; Teng MA ; Zhuoran XIA ; Fengtao CUI ; Li CHEN ; Yanyan ZHENG ; Piye NIU
Journal of Environmental and Occupational Medicine 2026;43(3):333-340
Background Work-related musculoskeletal disorders (WMSDs) are a major occupational health concern, particularly among workers exposed to adverse ergonomic conditions. Manganese production involves heavy physical demands, yet research on WMSDs among manganese workers remains limited. Objective To investigate the prevalence and influencing factors of WMSDs among manganese workers in a manganese enterprise in Guangxi. Methods A cross-sectional survey was conducted from May to June 2024 on workers at a manganese factory in Guangxi. The Chinese Musculoskeletal Disorders Questionnaire was used to collect information on demographic characteristics, distribution of musculoskeletal symptoms, and work-related exposures. χ2 test was applied to compare differences in positive WMSDs rates across groups, and logistic regression analysis was performed to identify associated factors. Results A total of 1476 workers were enrolled in the study after pre-determined inclusion and exclusion criteria. The overall prevalence of WMSDs was 34.15%. The most commonly affected body regions were the lower back (17.28%), neck (16.67%), and shoulders (13.82%). The results of logistic regression analysis indicated that female, older age, and education level of college or above were associated with a higher risk of WMSDs (P<0.05). Awkward working postures were significantly associated with WMSDs in corresponding body regions; in particular, awkward postures of the neck, upper limbs, trunk, and lower limbs were related to an increased risk of WMSDs in multiple body sites (P<0.05). In addition, poor lighting conditions, high workplace temperature, frequent or sustained arm support during work, and high job demands were associated with an increased risk of overall or site-specific WMSDs (P<0.05). Conclusion The high prevalence of WMSDs among manganese workers is closely associated with demographic characteristics, working postures, and work environment and organizational factors. Targeted ergonomic interventions focusing on high-risk body regions and key ergonomic exposures are warranted to reduce the risk of WMSDs among manganese workers.
4.Predictive model of 4-year cognitive decline risk in middle-aged adults in rural area of Xi'an
Ling GAO ; Yucheng PANG ; Suhang SHANG ; Liangjun DANG ; Shan WEI ; Jin WANG ; Qiumin QU ; Kang HUO
Journal of Xi'an Jiaotong University(Medical Sciences) 2025;46(5):811-817
Objective To develop a risk predictive model of cognitive decline in a prospective cohort study in rural area of Xi'an and compare the predictive performance with that of the classical CAIDE model.Methods The cohort was established between October 2014 and March 2015 in two selected villages in rural Xi'an.Mini-Mental State Examination(MMSE)was applied to assess global cognition at baseline and 4-year follow-up,and cognitive decline was defined as a drop of ≥4 points in MMSE after 4-year follow-up.Participants were randomly split into training set and validation set in a ratio of 7∶3.The Logistic regression analysis was used to develop the predictive model,and the area under the receiver operating characteristic(ROC)curve was applied to assess the performance of the risk model.Results Occurrence of cognitive decline after 4-year follow-up was 4.15%.Future cognitive decline was significantly predicted by age,low education and stroke(AUC in training set=0.73,95%CI:0.63-0.79;AUC in valid data=0.77,95%CI:0.67-0.87),while the classical CAIDE model did not predict the risk of cognitive decline well(AUC=0.68,95%CI:0.61-0.75).The results differed after stratification by APOE genotype,and showed a better predictive value of both our model(AUC=0.87,95%CI:0.78-0.96)and CAIDE model(AUC=0.89,95%CI:0.81-0.98)in APOE ε4 carriers.Conclusion The predictive model was developed based on age,educational level and stroke,and it predicted relatively well 4-year cognitive decline as compared with traditional CAIDE model,especially in APOE ε4 carriers.However,the model should be validated after longer follow-up and further improved to increase its predictive value.
5.Advances in centrosome amplification and cancer development
Zhaoxue WANG ; Xin MENG ; Shiyun ZHANG ; Ke SHI ; Yucheng LU
Chinese Journal of Pathophysiology 2025;41(10):2038-2045
Centrosome amplification is a hallmark of malignant tumours and has been established as a critical carcinogenic factor driving the progression of various malignancies.This review systematically outlines the structural com-position and replication cycle of the centrosome,thoroughly analyses the specific manifestations of abnormal centrosome amplification in tumor cells,and explores the molecular mechanisms underlying centrosome amplification.Furthermore,this review highlights therapeutic strategies targeting abnormal centrosome expansion and their potential application in tu-mor intervention.In-depth investigations of centrosome amplification mechanisms and intervention pathways may offer novel insights for early cancer diagnosis and precision therapy.
6.Effect of intrathecal morphine combined with liposomal bupivacaine adductor canal block on postopera-tive analgesia and opioid-sparing effect in patients undergoing total knee arthroplasty
Chenglong LI ; Lun WAN ; Lisha HUANG ; Yucheng ZHAN ; Shiying LONG ; Zheng WANG
The Journal of Practical Medicine 2025;41(19):3083-3088
Objective To evaluate the effects of low-dose intrathecal morphine(ITM)combined with liposomal bupivacaine adductor canal block(LB-ACB)on postoperative analgesia and opioid-sparing efficacy in patients undergoing total knee arthroplasty(TKA).Methods In this randomized,double-blind,controlled trial,80 TKA patients were allocated to either an intervention group(ITM 0.1 mg+LB-ACB,n=40)or a control group(intrathecal saline+LB-ACB,n=40).Primary outcomes included resting/movement visual analog scale(VAS)scores at 6,12,24,48,and 72 hours postoperatively,48-hour morphine consumption,time to first rescue analgesia,and incidence of complications.Results(1)The intervention group showed significantly lower resting and movement VAS scores at 6,12,24,and 48 hours postoperatively compared with controls(all P<0.05),except at 72 hours(P>0.05).(2)The intervention group had a significant reduction in 48-hour morphine consumption(4.58±1.0 mg vs.9.34±4.8 mg,P=0.027),a significantly lower rescue analgesia rate(15.0%vs.47.5%,P=0.002),and a significantly prolonged time to first rescue analgesia(48.8±7.5 h vs.14.5±5.5 h,P<0.001).(3)The intervention group demonstrated a significant decrease in the incidence of nausea(from 15.0%to 35.0%,P=0.039)and vomiting(from 10.0%to 27.5%,P=0.045),but no significant differences were observed in the incidences of pruritus,urinary retention,or motor block(all P>0.05).Conclusion Low-dose ITM(0.1 mg)combined with LB-ACB significantly enhances early postoperative analgesia,reduces opioid consumption,and decreases nausea/vomiting risk,without increasing the risks of other complications.This regimen aligns with enhanced recovery after surgery(ERAS)principles.
7.Design of customized Gyroid condylar prosthesis and finite element analysis of articular disc
Tingting JIANG ; Danyu LIU ; Zhixiu JIANG ; Yuchen JI ; Yilin CAO ; Yucheng SU ; Xinyu WANG
Chinese Journal of Tissue Engineering Research 2025;29(28):6003-6011
BACKGROUND:Condylar prosthesis replacement,as one of the surgical methods for the treatment of temporomandibular joint diseases,not only needs to restore the morphology and function,but also needs to ensure long-term stable application.OBJECTIVE:To design finite element analysis of a customized Gyroid condylar prosthesis.METHODS:Gyroid structure specimens with different wall thicknesses(250,350,450,550,650,and 750 μm)were designed by software.Finite element simulation compression experiments were carried out to test the elastic modulus of the specimens.The Gyroid structure wall thickness range that matches the elastic modulus of mandibular cancellous bone and whose pore size meets the osteogenesis conditions was screened out.This range was subdivided and Gyroid structure specimens were made using 3D printing technology.Mechanical compression experiments were carried out on a universal testing machine.The Gyroid structure wall thickness that meets the mechanical properties of mandibular bone,has an easier osteogenesis and a smaller strength was screened out by elastic modulus and compressive strength,and subsequent experiments were carried out.A three-dimensional model of a customized Gyroid condylar prosthesis was designed,and the finite element analysis of the blade jaw position and cusp interdigitation position of the model under natural occlusion was simulated.RESULTS AND CONCLUSION:(1)Finite element analysis results showed that with the increase of wall thickness,the elastic modulus of Gyroid structure specimens increased.The elastic modulus of Gyroid structure specimens with wall thickness of 350,450,550,650,and 750 μm matched the elastic modulus of mandibular cancellous bone.Since the subsequent experiments needed to be subdivided into groups and the pore size of the 550,650,and 750 μm wall thickness group(pore size 800-1 000 μm)was within the osteogenesis range.Gyroid structure specimens with wall thickness of 550,600,650,700,and 750μm were selected for mechanical compression experiments on a universal testing machine.(2)The results of mechanical compression experiments showed that with the increase of wall thickness,the elastic modulus and compressive strength of Gyroid structure specimens increased.The elastic modulus of Gyroid structure specimens with wall thickness of 550,600,and 650 μm was within the elastic modulus of the mandibular cancellous bone.Finally,the wall thickness of 650 μm and the pore size of 900 μm were selected to construct the three-dimensional model of the mandibular customized Gyroid condylar prosthesis.(3)The results of finite element analysis of three-dimensional model of the mandibular customized Gyroid condylar prosthesis showed that the stress of the articular disc in the edge-to-edge occlusion was mainly concentrated on the lower surface of the anterior middle band,and the stress of the articular disc in the interposition of tooth tips was mainly concentrated on the lateral surface of the lower surface.The maximum displacement and the maximum equivalent stress of the left and right articular discs in the edge-to-edge occlusion and the interposition of tooth tips were similar.The maximum displacement was 0.031,0.030,0.028,and 0.018 mm,and the maximum equivalent stress was 2.87,2.30,2.73,and 1.71 MPa,respectively.(4)The results showed that the Gyroid structure with a wall thickness of 650 μm was consistent with the mechanical properties of the mandible,which reduced the strength of the titanium alloy and reduced the damage of the articular disc caused by the customized Gyroid condylar prosthesis.
8.Advances in centrosome amplification and cancer development
Zhaoxue WANG ; Xin MENG ; Shiyun ZHANG ; Ke SHI ; Yucheng LU
Chinese Journal of Pathophysiology 2025;41(10):2038-2045
Centrosome amplification is a hallmark of malignant tumours and has been established as a critical carcinogenic factor driving the progression of various malignancies.This review systematically outlines the structural com-position and replication cycle of the centrosome,thoroughly analyses the specific manifestations of abnormal centrosome amplification in tumor cells,and explores the molecular mechanisms underlying centrosome amplification.Furthermore,this review highlights therapeutic strategies targeting abnormal centrosome expansion and their potential application in tu-mor intervention.In-depth investigations of centrosome amplification mechanisms and intervention pathways may offer novel insights for early cancer diagnosis and precision therapy.
9.Expert consensus:Prevention and treatment of dental implant biological complications
Xing WANG ; Liping WANG ; Qintao WANG ; Rong SHU ; Dongying XUAN ; Yiqun WU ; Lixin QIU ; Derong ZOU ; Yingliang SONG ; Jiang CHEN ; Yan XU ; Jincai ZHANG ; Yucheng SU ; Linhu GE ; Yufeng XIE
STOMATOLOGY 2025;45(11):801-807
Dental implantology has developed rapidly for over half a century,since pure titanium(99.7%)dental cylindrical threaded implants were exploited and osseointegration was introduced in 1960s by Prof.Br?nemark.The long term retention rates of 10 years or more are over 95%.However,the biological complications jeopardize the long term effects of dental implant treatment seriously.The prevalence of dental implant biological complications varies greatly among different reports resulting from the disparities on the defini-tions of dental implant biological complications.After analyzing and summarizing the major opinions proposed internationally in recent years,the consensus for the definition of dental implant biological complications has been reached.Generally the dental implant biologi-cal implications can be classified into early stage(before restoration)biological complications and late stage(after restoration)biological complications.The early stage biological complications include acute and chronic infections,pain,soft tissue deficiency,and osseointegration failure,etc.The late stage complications include peri-implant diseases(peri-implant mucositis and peri-implantitis),soft tissue deficiency around implant,implant loosening and dropping off,etc.The various risk factors related to different dental implant biological complications,the strategies of the prevention and treatment for the dental implant biological complications have been discussed comprehensively,and the consensus has been reached.It is aimed to advocate the dentist to pay more attention to the early prevention of the biological implant complications,to promote more researches on the implant biological complications,and to help elevate the level of dental implantology in our country.
10.Design of customized Gyroid condylar prosthesis and finite element analysis of articular disc
Tingting JIANG ; Danyu LIU ; Zhixiu JIANG ; Yuchen JI ; Yilin CAO ; Yucheng SU ; Xinyu WANG
Chinese Journal of Tissue Engineering Research 2025;29(28):6003-6011
BACKGROUND:Condylar prosthesis replacement,as one of the surgical methods for the treatment of temporomandibular joint diseases,not only needs to restore the morphology and function,but also needs to ensure long-term stable application.OBJECTIVE:To design finite element analysis of a customized Gyroid condylar prosthesis.METHODS:Gyroid structure specimens with different wall thicknesses(250,350,450,550,650,and 750 μm)were designed by software.Finite element simulation compression experiments were carried out to test the elastic modulus of the specimens.The Gyroid structure wall thickness range that matches the elastic modulus of mandibular cancellous bone and whose pore size meets the osteogenesis conditions was screened out.This range was subdivided and Gyroid structure specimens were made using 3D printing technology.Mechanical compression experiments were carried out on a universal testing machine.The Gyroid structure wall thickness that meets the mechanical properties of mandibular bone,has an easier osteogenesis and a smaller strength was screened out by elastic modulus and compressive strength,and subsequent experiments were carried out.A three-dimensional model of a customized Gyroid condylar prosthesis was designed,and the finite element analysis of the blade jaw position and cusp interdigitation position of the model under natural occlusion was simulated.RESULTS AND CONCLUSION:(1)Finite element analysis results showed that with the increase of wall thickness,the elastic modulus of Gyroid structure specimens increased.The elastic modulus of Gyroid structure specimens with wall thickness of 350,450,550,650,and 750 μm matched the elastic modulus of mandibular cancellous bone.Since the subsequent experiments needed to be subdivided into groups and the pore size of the 550,650,and 750 μm wall thickness group(pore size 800-1 000 μm)was within the osteogenesis range.Gyroid structure specimens with wall thickness of 550,600,650,700,and 750μm were selected for mechanical compression experiments on a universal testing machine.(2)The results of mechanical compression experiments showed that with the increase of wall thickness,the elastic modulus and compressive strength of Gyroid structure specimens increased.The elastic modulus of Gyroid structure specimens with wall thickness of 550,600,and 650 μm was within the elastic modulus of the mandibular cancellous bone.Finally,the wall thickness of 650 μm and the pore size of 900 μm were selected to construct the three-dimensional model of the mandibular customized Gyroid condylar prosthesis.(3)The results of finite element analysis of three-dimensional model of the mandibular customized Gyroid condylar prosthesis showed that the stress of the articular disc in the edge-to-edge occlusion was mainly concentrated on the lower surface of the anterior middle band,and the stress of the articular disc in the interposition of tooth tips was mainly concentrated on the lateral surface of the lower surface.The maximum displacement and the maximum equivalent stress of the left and right articular discs in the edge-to-edge occlusion and the interposition of tooth tips were similar.The maximum displacement was 0.031,0.030,0.028,and 0.018 mm,and the maximum equivalent stress was 2.87,2.30,2.73,and 1.71 MPa,respectively.(4)The results showed that the Gyroid structure with a wall thickness of 650 μm was consistent with the mechanical properties of the mandible,which reduced the strength of the titanium alloy and reduced the damage of the articular disc caused by the customized Gyroid condylar prosthesis.


Result Analysis
Print
Save
E-mail