1.Application of laser microporous decellularized scaffolds in tissue regeneration
Jianmei GU ; Kunshan YUAN ; Qiang ZHOU ; Haijun ZHANG
Chinese Journal of Tissue Engineering Research 2026;30(2):499-506
BACKGROUND:In the field of tissue engineering,decellularized scaffolds are widely used owing to their biocompatibility.Nonetheless,these scaffolds frequently encounter the limitation of inadequate cell infiltration due to their densely structured composition.Using laser micro-patterning technology for structural modification can improve cell adhesion and proliferation.OBJECTIVE:To summarize the research progress of laser microporous decellularized scaffolds in tissue regeneration.METHODS:Related literature was searched in PubMed and CNKI databases.The Chinese and English search terms were"decellularized scaffold,laser micro-patterning technology,laser microporous decellularized scaffold,extracellular matrix,laser drilling,tissue regeneration."References were screened according to inclusion and exclusion criteria,and 65 articles were finally included for analysis and discussion.RESULTS AND CONCLUSION:(1)Laser micro-patterning technology can selectively remove tissues to achieve scaffold modification.Laser treatment can have controllable effects on the pore structure,mechanical properties and cell permeability of the scaffold.(2)To obtain the optimal cell integration and remodeling effect,factors such as scaffold pretreatment,laser and decellularization process sequence,laser parameter setting,decellularization process and pore structure should be considered.(3)At present,the application of laser microporous decellularized scaffolds has shown that it can promote tissue repair,and it is also necessary to solve the problem of tissue thermal damage.Depending on the absorption of different wavelengths of laser light by the tissue,a reasonable selection of laser type is a feasible solution.(4)Tissue damage repair by laser microporous decellularized scaffold is expected to achieve clinical transformation,and optimizing laser technology and carrying out larger scale biosafety testing are future research directions.
2.Application of laser microporous decellularized scaffolds in tissue regeneration
Jianmei GU ; Kunshan YUAN ; Qiang ZHOU ; Haijun ZHANG
Chinese Journal of Tissue Engineering Research 2026;30(2):499-506
BACKGROUND:In the field of tissue engineering,decellularized scaffolds are widely used owing to their biocompatibility.Nonetheless,these scaffolds frequently encounter the limitation of inadequate cell infiltration due to their densely structured composition.Using laser micro-patterning technology for structural modification can improve cell adhesion and proliferation.OBJECTIVE:To summarize the research progress of laser microporous decellularized scaffolds in tissue regeneration.METHODS:Related literature was searched in PubMed and CNKI databases.The Chinese and English search terms were"decellularized scaffold,laser micro-patterning technology,laser microporous decellularized scaffold,extracellular matrix,laser drilling,tissue regeneration."References were screened according to inclusion and exclusion criteria,and 65 articles were finally included for analysis and discussion.RESULTS AND CONCLUSION:(1)Laser micro-patterning technology can selectively remove tissues to achieve scaffold modification.Laser treatment can have controllable effects on the pore structure,mechanical properties and cell permeability of the scaffold.(2)To obtain the optimal cell integration and remodeling effect,factors such as scaffold pretreatment,laser and decellularization process sequence,laser parameter setting,decellularization process and pore structure should be considered.(3)At present,the application of laser microporous decellularized scaffolds has shown that it can promote tissue repair,and it is also necessary to solve the problem of tissue thermal damage.Depending on the absorption of different wavelengths of laser light by the tissue,a reasonable selection of laser type is a feasible solution.(4)Tissue damage repair by laser microporous decellularized scaffold is expected to achieve clinical transformation,and optimizing laser technology and carrying out larger scale biosafety testing are future research directions.
3.Prevention,control monitoring of environmental carbapenem-resistant Klebsiella pneumoniae in intensive care unit of a three-A hospital
Yuan LI ; Guangnan SHAO ; Keju GU ; Liang TIAN ; Chunyan LI ; Yun LIU ; Huan TANG ; Fei WANG ; Wei JI
Chinese Journal of Nosocomiology 2025;35(9):1391-1395
OBJECTIVE To carry out regular monitoring of carbapenem-resistant Klebsiella pneumoniae(CRKP)contamination status in the environment of intensive care unit(ICU)and take targeted prevention and control measures so as to reduce the incidence of hospital-associated infections with multidrug-resistant organisms(MDROs).METHODS The surfaces of surroundings of the patients who were colonized and infected with CRKP in the ICU of grade A tertiary hospital of Shanghai and the hands of relevant staff were sampled by stages from Jan 1,2021 to Jun 30,2024.The distribution of the CRKP strains in the surroundings were analyzed according to the locations positive for CRKP,and the disinfection measures were accordingly and continuously modified.The trend of isolation rate of CRKP strains from the ICU patients was analyzed during the time period when the measures were implemented.RESULTS Totally 266 environmental samples were collected during the baseline period(from Jan.1 2021 to Dec.31 2021),265 during intervention period(from Jan.1 2022 to Dec.31 2023),274 during con-solidation period(from Jan.1 to Jun.30 2024);the isolation rates of the CRKP strains were 4.51%,4.91%and 3.65%,respectively.The isolation rate of the strains was highest from the bed unit(10.40%),followed by the article for public use(6.74%),articles used by health care workers(2.98%)and diagnosis and treatment arti-cles(1.91%).The isolation rate of CRKP of the patients was 24.75%during the baseline period,15.48%during the intervention period,5.69%during the consolidation period,showing a continuously downward trend(x2=30.330,P<0.001).CONCLUSION It is necessary to regularly carry out the environmental monitoring of CRKP strains,seek for the weak links of environmental disinfection and implement the intensified prevention and control measures so as to reduce the incidence of CRKP infection,which may provide theoretical bases for effective control of the CRKP strains.
4.Analysis of the process framework and optimization strategies for the transformation of scientific and technological achievements in public hospitals based on Grounded Theory
Zi-wen XU ; Jia-jie ZHAO ; Dan-na ZHAO ; San-yuan HAO ; Zi-wei WANG ; Gu-yang FU ; Ren CHEN
Chinese Journal of Health Policy 2025;18(5):74-80
Objective:To understand the workflow and key tasks of the transformation of scientific and technological achievements in public hospitals,and propose optimization strategies from the perspective of managers.Methods:Based on the research method of Grounded Theory,semi-structured interviews were conducted among 23 managers of scientific and technological achievements transformation in public hospitals,and relevant concepts and categories were summarized by three stages coding with NVivo 12.Results:Through the three stages of coding,64 initial concepts,19 categories and 4 main categories were sorted out,and a framework diagram of the process of transforming scientific and technological achievements in public hospitals covering four stages was constructed.Conclusion:The scientific and technological achievements of public hospitals can be divided into four phases:project initiation and demand docking,research and development process and achievements incubation,achievements transformation and market docking,product promotion and industrial development,which can be used to achieve high-quality development of scientific and technological achievements through standardized management of the whole process,excavation of high-quality results,enhancement of humanistic construction,accumulation of scientific research experience,and standardization of qualification of technological managers.
5.Application of Lean Six Sigma in the construction of clinical coaching teacher qualification access system in university-affiliated hospitals
Shan LU ; Zhengqian LI ; Wenqing YUAN ; Yan LI ; Shixian GU
Chinese Journal of Medical Education Research 2025;24(2):241-245
In this study, we proposed an idea on systematic construction and optimization of a clinical coaching teacher qualification access system in Peking University Third Hospital by combining lean thinking and the Six Sigma methodology and following the steps of definition, measurement, analysis, improvement, and control. Based on the constructivism theory, the clinical coaching teacher qualification access system is divided into two progressive sessions: access to clinical coaching qualifications and access to theoretical teaching qualifications. By analyzing the appraisal data of clinical coaching teacher qualification access in the past 10 years, we revealed the data characteristics of pass rates of clinical coaching qualifications to determine the goal for dynamic improvement. On top of this analysis, we identified measures to maintain a stable pass rate of clinical coaching teacher qualification access, optimized the development direction and path of the clinical coaching teacher qualification access, and continuously promoted the teaching ability of teachers through the coordinated implementation of different systems and measures. In our research, we expanded the administrative scope of the access system, sorted out the objectives and paths of the system improvement, and provided a practical reference for constructing a clinical coaching teacher qualification access system and promoting the construction of teaching quality standardization in university-affiliated hospitals.
6.Application of intelligent APP in process assessment of standardized residency training
Mengxuan LÜ ; Shan LU ; Wenqing YUAN ; Jinyi GU ; Shixian GU
Chinese Journal of Medical Education Research 2025;24(3):374-381
Objective:To construct an intelligent APP-assisted process assessment mode for standardized residency training and explore its application effect.Methods:Based on the "XUEYIKU" APP platform developed in Peking University Third Hospital, we built a standardized process of process assessment for standardized residency training assisted by intelligent APP and combining both online and offline components. We analyzed the frequency of APP use, satisfaction with the APP, the problems solved by the APP, and the aspects that need to be improved. SPSS 26.0 was used for t-test and Chi-square test. Results:The satisfaction score of teachers with the APP was (7.66±1.86) points. The satisfaction score of professional base teaching directors/process assessment coordinators was higher than that of clinical teachers [(8.28±1.30) vs. (7.42±1.99), P=0.013]. Most residents were satisfied with the APP (67.44%, 29/43), regarded its role in supporting the entire assessment process as important (55.81%, 24/43), and reviewed teacher feedback (65.12%, 28/43). Some teachers indicated that the APP solved problems such as paperless exam scoring (59.00%, 59/100), standardized exam processes (43.00%, 43/100), score statistics (42.00%, 42/100), and score reporting (42.00%, 42/100). The residents believed that the APP resolved issues such as exam notification (44.19%, 19/43), scheduling (41.86%, 18/43), and result feedback (41.86%, 18/43). Both teachers and residents mentioned the need for further strengthening the stability of the APP system and simplifying operational steps. Conclusions:With APP as a link, through the instant transmission and feedback of data, the intelligent APP-assisted process assessment mode drives the reflection and summarization of professional bases, clinical teachers, and residents, and promotes the post competence of residents.
7.Photon-counting detector CT with virtual monoenergetic imaging in enabling a quadruple low-dose aortic CT angiography protocol: a feasibility study
Ke QI ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Mengyuan ZHANG ; Weiting ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Jie LIU
Chinese Journal of Radiology 2025;59(10):1133-1141
Objective:To assess the viability of reducing radiation dose, contrast media volume, injection flow rate and contrast medium concentration (quadruple low-dose protocol) by utilizing virtual monoenergetic images (VMI) in photon-counting detector CT (PCD-CT) for aortic CT angiography (CTA), while maintaining image quality in comparison to images obtained from energy-integrating detector CT (EID-CT).Methods:From April 2024 to June 2024, a total of 40 participants who underwent aortic CTA on PCD-CT were prospectively enrolled in the experimental group (PCD-CT group), while 40 patients with similar baseline characteristics who had previously undergone aortic CTA using EID-CT were retrospectively selected for the conventional group (EID-CT group). The EID-CT group used a tube voltage of 90 kVp, a contrast media volume of 60 ml of contrast, an injection flow rate of 3 ml/s, and a contrast concentration of 350 mgI/ml; the PCD-CT group used the QuantumPlus mode, with a tube voltage of 140 kVp, a total amount of iodine in the contrast media of 140 mgI/kg, and an injection flow rate=contrast media volume/(delay time+scan time), and a contrast media concentration of 320 mgI/ml. VMIs in PCD-CT group were reconstructed in 5-keV intervals ranging from 45 to 65 keV. The effective radiation dose and contrast injection protocols were recorded and compared between two groups. Objective image quality assessment was performed for each group. CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured at five anatomical locations (ascending aorta, aortic arch, descending aorta, abdominal aorta, and right common iliac artery), and image noise was recorded. Subjective image quality was independently evaluated by two readers using a 5-point Likert scale in a blinded manner. Based on data normality, the one-way ANOVA or Kruskal-Wallis test was used for image quality assessment, with Bonferroni-corrected post-hoc analysis for multiple comparisons.Results:There were no significant differences in the baseline characteristics between two groups (all P0.05). The PCD-CT group demonstrated significantly lower effective radiation dose [(3.88±0.65) mSv vs. (5.97±1.15)mSv], contrast media volume [(29.25±4.56) ml vs. 60 ml], and injection rate [(2.65±0.42) ml/s vs. 3 ml/s] than the EID-CT group, with reductions of 35%, 51%, and 12%, respectively (all P0.001). For objective image quality, except for the ascending aortic CT attenuation, the CT attenuation, SNR, and CNR of other vessels in the 55 keV PCD-CT group were comparable to those in the EID-CT group. Additionally, the difference in image noise between these two groups was not statistically significant ( P0.05). Concerning subjective image quality, at 55 keV, the PCD-CT group had similar image noise scores and vessel attenuation scores (both P0.05) and better visualization of renal artery branching ( P=0.001) compared to the EID-CT group. Conclusion:In comparison to EID-CT, the use of a 55 keV image in PCD-CT for aortic CTA has demonstrated reductions in radiation dose, contrast media volume, injection flow rate and contrast medium concentration, while maintaining image quality.
8.Feasibility study of photon counting CT combined with “quadruple lows” technology in head and neck vascular imaging
Mengyuan ZHANG ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Weiting ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Jie LIU
Chinese Journal of Radiology 2025;59(8):942-948
Objective:To evaluate the feasibility of head and neck vascular imaging using photon-counting detector computed tomography (PCD-CT) combined with a “quadruple lows” protocol—characterized by low contrast media volume, low iodine concentration, low injection rate, and low radiation dose—and to compare the image quality with that obtained by energy-integrating detector CT (EID-CT).Methods:A total of 105 patients with suspected cerebrovascular disease were prospectively enrolled at the First Affiliated Hospital of Zhengzhou University between April and June 2024. Patients were randomly assigned to three groups ( n=35). Group A underwent conventional head and neck CTA using EID-CT. Group B underwent PCD-CT with a protocol involving ultra-low contrast media volume, low iodine concentration, and low injection rate. Group C underwent PCD-CT with the full “quadruple low” protocol. Objective image quality parameters—including CT attenuation, image noise (standard deviation, SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR)—were measured at the ascending aorta, common carotid artery, internal carotid artery, vertebral artery, basilar artery, posterior cerebral artery, and middle cerebral artery. Two radiologists independently rated subjective image quality using a 5-point Likert scale. Differences among groups were analyzed using one-way ANOVA and the Kruskal-Wallis test. Results:Compared to Group A [contrast volume: (42.78±6.64)ml], contrast agent volume was significantly reduced in Groups B and C[ (26.26±4.45) ml and (26.54±3.83)ml, respectively], demonstrating reductions of 39% and 38% (both P<0.01). The iodine concentration was 320 mg/ml in Groups B and C, lower than 350 mg/ml in Group A (8.5%). The injection rate was also reduced in Groups B and C [(3.39±0.61) and (3.55±0.51)ml/s, respectively] compared to Group A [(4.28±0.66) ml/s], with reductions of 21% and 17% (both P<0.01). The effective dose (ED) was similar between Groups A and B [(1.40±0.15) vs. (1.40±0.19)mSv, P>0.05], while Group C demonstrated a significantly lower ED [(0.99±0.09) mSv], with a reduction of 30% compared to Group A and 29% compared to Group B (both P<0.01).In terms of objective image quality, significant differences in image noise (SD) were observed among the three groups at the vertebral artery, internal carotid artery, posterior cerebral artery, and middle cerebral artery (all P<0.05). Groups B and C showed significantly lower SD compared to Group A ( P<0.05), with no significant difference between B and C ( P>0.05). SNR was significantly higher in Groups B and C than in Group A at multiple vascular segments (all P<0.05). CNR differed only at the internal carotid artery, where Groups B and C demonstrated superior performance compared to Group A ( P<0.05).Subjective image quality scores showed no significant difference between Groups A and C ( P>0.05), while Group B had significantly higher scores than both A and C ( P<0.05). All images were deemed diagnostically acceptable. Conclusion:Compared with conventional EID-CT, PCD-CT combined with a “quadruple lows” protocol enables substantial reductions in contrast media and radiation dose while further improving image quality in head and neck CTA.
9.Risk factors and early warning model of coagulation with extracorporeal circulation device in uremic patients with CRRT
Yuan SUN ; Yunyu GU ; Yan HUANG
China Modern Doctor 2025;63(1):38-42
Objective To investigate the risk factors of coagulation with extracorporeal circulation device in uremic patients with continuous renal replacement therapy(CRRT),and establish and verify the risk warning model.Methods A total of 210 uremic patients who received CRRT treatment in the Second Affiliated Hospital of Nanchang University from March 2020 to March 2022 were retrospectively selected as training set,and divided into coagulation group and non-coagulation group according to whether coagulation occurred during CRRT treatment.At the same time,90 uremic patients who underwent CRRT treatment in our hospital from April 2022 to April 2023 were selected as validation set according to the ratio of 7:3.Univariate analysis and multivariate Logistic regression were used to analyze the factors related to coagulation with extracorporeal circulation device in uremic patients with CRRT,and a risk prediction model was constructed.The receiver operating characteristic(ROC)curve was used to verify the prediction efficiency of the model.Results In training set,53 patients had coagulation with extracorporeal circulation device,the incidence was 25.24%.Multivariate Logistic regression analysis showed that age≥60 years old,agitation,decreased blood flow,elevated platelet count,and elevated transmembrane pressure were all risk factors for coagulation in patients with uremia treated with CRRT(P<0.05).The Hosmer-Lemeshow test results of the training set showed that the model had a good goodness of fitting,and area under the curve(AUC)of the model was 0.956(95%CI:0.926-0.985,P<0.05)when CRRT was applied to uremic patients,and the sensitivity was 86.40%,the specificity was 83.80%.The goodness of fitting of the validation set was good.The AUC of the prediction model was 0.946(95%CI:0.915-0.977,P<0.05),the sensitivity was 82.60%,and the specificity was 81.80%.Conclusion The risk early warning model based on the above risk factors has a good prediction effect,and can provide a reference for clinical identification of the occurrence of coagulation with extracorporeal circulation device in uremic patients with CRRT.
10.Research progress on glucose metabolism reprogramming of tumor-associated macrophages in gastric cancer
Yun-tian DENG ; Yuan GU ; Yi-hong SUN ; Hong-shan WANG
Fudan University Journal of Medical Sciences 2025;52(5):717-723
Tumor-associated macrophages(TAMs)are one of the key components of the tumor microenvironment(TME)in gastric cancer.Glucose metabolism reprogramming significantly impacts TAMs'polarization and immune functions,thereby regulating the onset and the progression of gastric cancer.This review summarizes glucose metabolism reprogramming in TAMs'polarization and explores its role in gastric cancer-related TAMs through aspects such as signaling regulation,transcription factors,and epigenetic modifications.This review aims to deepen the understanding of TAMs'role in gastric cancer progression and offer new perspectives for the immunotherapy in gastric cancer.

Result Analysis
Print
Save
E-mail