1.Comparative analyses of the detection performance of five multiplex polymerase chain reaction nucleic acid detection kits for respiratory pathogens
Fang YUAN ; Lei BI ; Jiajing LIU ; Huanru WANG ; Jun FENG ; Yuan ZHUANG ; Min CHEN ; Zheng TENG
Shanghai Journal of Preventive Medicine 2026;38(2):165-169
ObjectiveTo evaluate the detection specificity for clinical samples and the detection capability for standard substances of five commercially available multiplex polymerase chain reaction (PCR) nucleic acid detection kits (hereinafter referred to as the kits) for respiratory pathogens, and to provide a reference for selecting appropriate detection kits for multi-pathogen nucleic acid testing of respiratory infections. MethodsA total of 60 respiratory pathogen-positive clinical samples with known redults were selected and tested using the five kits (labeled as A, B, C, D, and E). The detection rates and Kappa coefficients were calculated to evaluate the consistency between the results from these kits and those from single-pathogen PCR kits. According to the limit of detection (LOD) provided by the kits, standard substances of respiratory pathogens (including 12 types such as influenza virus, Mycoplasma pneumoniae, and Bordetella pertussis) were diluted to four concentrations (250, 500, 1 000, and 2 000 copies·mL⁻¹). All five kits were used for detection to evaluate their respective detection capabilities. ResultsCompared with the results from single-pathogen PCR kits, the five tested kits demonstrated good consistency (all Kappa >0.80). Among them, Kit A had the highest detection rate (100.00%), followed by Kits C and E (98.33%), and then Kits B and D (95.00%). All five kits showed a relatively low false negative rate (FNR) for samples with a cycle threshold (Ct) value ≤35 (≤2.38%). However, for samples with Ct values>35, the FNR increased accordingly(average FNR=6.67%, P=0.029). Kit C exhibited the highest detection sensitivity for the tested standard substances (average LOD: 458.33 copies·mL⁻¹), followed by Kit D, then Kits A/E, and finally Kit B. ConclusionThe five multiplex PCR kits showed good consistency with single-pathogen detection results, but each had its own performance emphasis. Kit A, with the highest detection rate and high throughput, is suitable for targeted viral screening. Kit B, covering the broadest pathogen spectrum (including fungi/bacteria), is suitable for comprehensive respiratory pathogen screening. Kits C, D and E, are applicable for rapid detection. It is important to note that the detection efficacy of all kits decreases for low viral load samples with Ct values >35. In practical application, selection should be based on specific screening objectives, throughput requirements, and sample types.
2.Development and validation of assessment and diagnostic tools for apraxia of speech of Chinese Putonghua
Tianhao NI ; Siyu BI ; Yuan DAI ; Hong QIAN ; Yongli WANG ; Qin WAN ; Zhaoming HUANG
Chinese Journal of Rehabilitation Theory and Practice 2026;32(5):550-560
ObjectiveTo develop an assessment tool for apraxia of speech (AOS) of Chinese Putonghua speakers and test its reliability and validity. MethodsThe Chinese Apraxia of Speech Assessment and Diagnostic Tool (CAADT) was developed based on the Apraxia of Speech Rating Scale 3.5, combined with the linguistic characteristics of Chinese and clinical experience. The tool consistsed of eleven items across three sections: articulation, prosody and alternating motion rates. Six experts evaluated the content validity. From November, 2024 to May, 2025, 51 patients with post-stroke AOS (experimental group) and ten patients with post-stroke aphasia without AOS (control group) were recruited from Anhui Wannan Rehabilitation Hospital (the Fifth People's Hospital of Wuhu), and tested with CAADT. Reliability was assessed using Cronbach's α coefficient, Kendall's coefficient of concordance W and Pearson correlation coefficient. Validity was evaluated using the content validity index (CVI) and Spearman correlation coefficient. Discriminative effect was analyzed using the receiver operating characteristic (ROC) curve. ResultsThe Cronbach's α coefficients for the articulation and prosody sections and the total scale were all > 0.9, while it was 0.454 for the alternating motion rates. Inter-rater reliability was good (W ≥ 0.598, P < 0.001). Test-retest reliability showed high positive correlations for the three sections and the total score between the two assessments (r ≥ 0.84, P < 0.001). The scale-level CVI was 0.95, and the item-level CVI ≥ 0.83. The Spearman correlation coefficients among the sections ranged from 0.30 to 0.70. ROC analysis revealed an area under the curve of 0.953, with a cut-off value of 11, yielding a sensitivity of 0.92 and a specificity of 0.90. ConclusionCAADT demonstrates good reliability, validity and discriminative effect, which can be used for clinical assessment and auxiliary diagnosis of Chinese Putonghua speaking patients with post-stroke AOS.
3.Production Research and Risk Factor Analysis of Transfusion and Infusion Warmer Based on Real-World Data.
Hongfeng BI ; Yonggang WANG ; Zhendong WANG ; Yuan FU ; Huifang NIU
Chinese Journal of Medical Instrumentation 2025;49(4):466-472
OBJECTIVE:
To investigate the transfusion and infusion warmer manufacturers, combine the use failures to analyze adverse events, and provide support for enterprise risk management and clinical safe use.
METHODS:
The sentinels from 7 manufacturing enterprises and 11 medical institutions that participated in Shandong Province's key monitoring program during the "14th Five-Year Plan" period were targeted. This was done by understanding the equipment's principles, structures, and quality control. Additionally, real-world data from January 2019 to December 2023 were collected to count adverse events.
RESULTS:
During production, there are risks in switching power supply stability and solder joint firmness. Fifteen kinds of faults occurred during use, and common faults such as inability to heat, unable to turn on the machine, and bubbles in the infusion tube accounted for more than 80%.
CONCLUSION
There are many risk points and failures for transfusion and infusion warmers, so enterprises should improve processes and quality control to address risks, and medical institutions should formulate specifications and maintenance plans to provide targeted theoretical basis for supervision.
Blood Transfusion/instrumentation*
;
Risk Factors
;
Quality Control
;
Humans
;
Risk Management
;
Equipment Failure
4.Effect of Acupuncture on Clinical Symptoms of Patients with Intractable Facial Paralysis: A Multicentre, Randomized, Controlled Trial.
Hong-Yu XIE ; Ze-Hua WANG ; Wen-Jing KAN ; Ai-Hong YUAN ; Jun YANG ; Min YE ; Jie SHI ; Zhen LIU ; Hong-Mei TONG ; Bi-Xiang CHA ; Bo LI ; Xu-Wen YUAN ; Chao ZHOU ; Xiao-Jun LIU
Chinese journal of integrative medicine 2025;31(9):773-781
OBJECTIVE:
To evaluate the clinical effect and safety of acupuncture manipulation on treatment of intractable facial paralysis (IFP), and verify the practicality and precision of the Anzhong Facial Paralysis Precision Scale (Eyelid Closure Grading Scale, AFPPS-ECGS).
METHODS:
A multicentre, single-blind, randomized controlled trial was conducted from October 2022 to June 2024. Eighty-nine IFP participants were randomly assigned to an ordinary acupuncture group (OAG, 45 cases) and a characteristic acupuncture group (CAG, 44 cases) using a random number table method. The main acupoints selected included Yangbai (GB 14), Quanliao (SI 18), Yingxiang (LI 20), Shuigou (GV 26), Dicang (ST 4), Chengjiang (CV 24), Taiyang (EX-HN 5), Jiache (ST 6), Fengchi (GB 20), and Hegu (LI 4). The OAG patients received ordinary acupuncture manipulation, while the CAG received characteristic acupuncture manipulation. Both groups received acupuncture treatment 3 times a week, with 10 times per course, lasting for 10 weeks. Facial recovery was assessed at baseline and after the 1st, 2nd and 3rd treatment course by AFPPS-ECGS and the House-Brackmann (H-B) Grading Scale. Infrared thermography technology was used to observe the temperature difference between healthy and affected sides in various facial regions. Adverse events and laboratory test abnormalities were recorded. The correlation between the scores of the two scales was analyzed using Pearson correlation coefficient.
RESULTS:
After the 2nd treatment course, the two groups showed statistically significant differences in AFPPS-ECGS scores (P<0.05), with even greater significance after the 3rd course (P<0.01). Similarly, H-B Grading Scale scores demonstrated significant differences between groups following the 3rd treatment course (P<0.05). Regarding temperature measurements, significant differences in temperatures of frontal and ocular areas were observed after the 2nd course (P<0.05), becoming more pronounced after the 3rd course (P<0.01). Additionally, mouth corner temperature differences reached statistical significance by the 3rd course (P<0.05). No safety-related incidents were observed during the study. Correlation analysis revealed that the AFPPS-ECGS and the H-B Grading Scale were strongly correlated (r=0.86, 0.91, 0.93, and 0.91 at baseline, and after 1st, 2nd, and 3rd treatment course, respectively, all P<0.01).
CONCLUSIONS
Acupuncture is an effective treatment for IFP, and the characteristic acupuncture manipulation enhances the therapeutic effect. The use of the AFPPS-ECGS can more accurately reflect the recovery status of patients with IFP. (Trial registration No. ChiCTR2200065442).
Humans
;
Acupuncture Therapy/methods*
;
Facial Paralysis/therapy*
;
Female
;
Male
;
Middle Aged
;
Adult
;
Treatment Outcome
;
Acupuncture Points
;
Aged
6.Analysis of cochlear reimplantation surgery and factors influencing postoperative auditory and speech function.
Qingling BI ; Zhongyan CHEN ; Yong LYU ; Wenjing YANG ; Xiaoyu XU ; Yan LI ; Yuan LI
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(5):419-424
Objective:The aim of this study was to present an institution's experience with cochlear reimplantation(CRI), to assess surgical challenges and post-operative outcomes and to increase the success rate of CRI. Methods:We retrospectively evaluated data from 76 reimplantation cases treated in a tertiary center between 2001 and 2022. Clinical features include caused of CRI, type of failure, surgical issues, and auditory speech performance were analyzed. Categorical Auditory Performance (CAP) and Speech Intelligibility Rating (SIR) scores were used to evaluate pre-and post-CRI outcomes. Our center's consecutive cohort of 1 126 patients had seven patients, while 69 patients were from other cochlear implant centers. Device failure was the most common cause of CRI(68/76), with the remaining cases including flap complications(3/76), magnet displacement(3/76), secondary meningitis(1/76), and foreign bodies around the implant(1/76). Postoperative auditory and speech outcome improved in 31.6%(24/76) of patients, remained unchanged in 63.2%(48/76), and decreased in CAP and SIR scores in 5.2%(4/76) of patients. Postoperatively, the seven patients with cochlear ossification and fibrosis scored lower on the overall CAP and SIR scale than non-ossification individuals, which is a significant factor in surgical success rates and auditory-speech outcomes. Conclusion:CRI surgery is a challenging but relatively safe procedure, and most reimplanted patients experience favorable postoperative outcomes. Medical complications and intracochlear damage are the main causes of poor postoperative results. Therefore, minimally invasive CI has a positive significance for reducing the difficulty of CRI surgery and improving the CI performance.
Humans
;
Cochlear Implantation/methods*
;
Retrospective Studies
;
Cochlear Implants
;
Male
;
Female
;
Postoperative Period
;
Treatment Outcome
;
Adult
;
Speech
;
Middle Aged
;
Postoperative Complications
;
Replantation
;
Cochlea/surgery*
7.Activation of Centromedial Amygdala GABAergic Neurons Produces Hypotension in Mice.
Xiaoyi WANG ; Ziteng YUE ; Luo SHI ; Wei HE ; Liuqi SHAO ; Yuhang LIU ; Jinye ZHANG ; Shangyu BI ; Tianjiao DENG ; Fang YUAN ; Sheng WANG
Neuroscience Bulletin 2025;41(5):759-774
The central amygdala (CeA) is a crucial modulator of emotional, behavioral, and autonomic functions, including cardiovascular responses. Despite its importance, the specific circuit by which the CeA modulates blood pressure remains insufficiently explored. Our investigations demonstrate that photostimulation of GABAergic neurons in the centromedial amygdala (CeMGABA), as opposed to those in the centrolateral amygdala (CeL), produces a depressor response in both anesthetized and freely-moving mice. In addition, activation of CeMGABA axonal terminals projecting to the nucleus tractus solitarius (NTS) significantly reduces blood pressure. These CeMGABA neurons form synaptic connections with NTS neurons, allowing for the modulation of cardiovascular responses by influencing the caudal or rostral ventrolateral medulla. Furthermore, CeMGABA neurons targeting the NTS receive dense inputs from the CeL. Consequently, stimulation of CeMGABA neurons elicits hypotension through the CeM-NTS circuit, offering deeper insights into the cardiovascular responses associated with emotions and behaviors.
Animals
;
GABAergic Neurons/physiology*
;
Male
;
Central Amygdaloid Nucleus/physiopathology*
;
Hypotension/physiopathology*
;
Mice
;
Blood Pressure/physiology*
;
Mice, Inbred C57BL
;
Solitary Nucleus/physiology*
;
Photic Stimulation
;
Neural Pathways/physiology*
8.Clinical efficacy of open reduction and internal fixation with plates versus minimally invasive Kirschner wire fixation for osteoporotic Colles' fractures.
Jun-Wei ZHANG ; Jin-Yong HOU ; Zhao-Hui LI ; Zhen-Yuan MA ; Xiang GAO ; Hong-Zheng BI ; Ling-Ling CHEN ; Hai-Tao WANG ; Wei-Zhi NIE ; Yong-Zhong CHENG ; Xiao-Bing XI
China Journal of Orthopaedics and Traumatology 2025;38(1):18-24
OBJECTIVE:
To compare the short-term clinical efficacy and safety of closed reduction with Kirschner wire fixation versus open reduction with plate fixation for treating osteoporotic Colles' fractures in middle-aged and elderly patients.
METHODS:
Between January 2018 and January 2023, 119 patients with Colles fractures were retrospectively analyzed, including 39 males and 80 females, aged from 48 to 74 years old with an average of(60.58±6.71) years old. The time from injury to operation ranged 1 to 13 days with an average of (5.29±2.52) days. According to the surgical method, they were divided into Kirschner wire fixation group (Kirschner wire group) and plate internal fixation group (plate group). In Kirschner wire group, there were a total of 68 patients, comprising 21 males and 47 females. The average age was (61.15±6.24) years old, ranged from 49 to 74 years old. Among them, 41 cases involved the left side while 27 cases involved the right side. In the plate group, there were a total of 51 patients, including 18 males and 33 females. The average age was (59.78±5.71) years old ranged from 48 to 72 years old. Among them, there were 31 cases on the left side and 20 cases on the right side. The following parameters were recorded before and after the operation:operation time, intraoperative blood loss, hospitalization days, hospitalization expenses, postoperative complications, and radiographic parameters of distal radius (distal radius height, ulnar deviation angle, palmar tilt angle). The clinical efficacy was evaluated at 3 and 12 months after the operation using Gartland-Werley and disabilites of the arm shoulder and hand (DASH) scores.
RESULTS:
The patients in both groups were followed up for a duration from 12 to 19 months with an average of(13.32±2.02) months. The Kirschner wire group exhibited significantly shorter operation time compared to the plate group 27.91(13.00, 42.00) min vs 67.52(29.72, 105.32) min, Z=-8.74, P=0.00. Intraoperative blood loss was also significantly lower in the Kirschner wire group than in the plate group 3.24(1.08, 5.40) ml vs 21.91(17.38, 26.44) ml, Z=-9.31, P=0.00. Furthermore, patients in the Kirschner wire group had a shorter length of hospital stay compared to those in the plate group (8.38±2.63) days vs (11.40±2.78) days, t=-3.12, P=0.00. Additionally, hospitalization cost was significantly lower in the Kirschner wire group than in the plate group 10 111.29(6 738.98, 13 483.60) yuan vs 15 871.11(11 690.40, 20 051.82) yuan, Z=-5.62, P=0.00. The incidence of complications was 2 cases in the Kirschner wire group and 1 case in the plate group, with no statistically significant difference(P>0.05). At 3 months postoprative, the radial height of the Kirschner wire group was found to be significantly smaller than that of the plate group, with measurements of (11.45±1.69) mm and (12.11±1.78) mm respectively (t=-2.06, P=0.04). However, there were no statistically significant differences observed in ulnar deviation angle and palmar tilt angle between the two groups (P>0.05). The DASH score and Gartland-Werley score in the Kirschner group were significantly higher than those in the plate group at 3 months post-operation (19.10±9.89) vs (13.47±3.51), t=4.34, P=0.00;(11.15±3.61) vs (6.41±2.75), t=8.13, P=0.00). However, there was no significant difference between the two groups at 12 months post-operation (P>0.05).
CONCLUSION
Compared to plate internal fixation, closed reduction with Kirschner wire support fixation yields a slightly inferior recovery of radial height;however, there is no significant disparity in the functional score of the affected limb at 12 months post-operation. Nonetheless, this technique offers advantages such as shorter operation time, reduced intraoperative blood loss, decreased hospitalization duration, and lower cost.
Humans
;
Female
;
Male
;
Middle Aged
;
Aged
;
Fracture Fixation, Internal/instrumentation*
;
Bone Wires
;
Bone Plates
;
Retrospective Studies
;
Colles' Fracture/surgery*
;
Minimally Invasive Surgical Procedures/methods*
;
Open Fracture Reduction/methods*
;
Osteoporotic Fractures/surgery*
9.Delayed covering causes the accumulation of motile sperm, leading to overestimation of sperm concentration and motility with a Makler counting chamber.
Lin YU ; Qing-Yuan CHENG ; Ye-Lin JIA ; Yan ZHENG ; Ting-Ting YANG ; Ying-Bi WU ; Fu-Ping LI
Asian Journal of Andrology 2025;27(1):59-64
According to the World Health Organization (WHO) manual, sperm concentration should be measured using an improved Neubauer hemocytometer, while sperm motility should be measured by manual assessment. However, in China, thousands of laboratories do not use the improved Neubauer hemocytometer or method; instead, the Makler counting chamber is one of the most widely used chambers. To study sources of error that could impact the measurement of the apparent concentration and motility of sperm using the Makler counting chamber and to verify its accuracy for clinical application, 67 semen samples from patients attending the Department of Andrology, West China Second University Hospital, Sichuan University (Chengdu, China) between 13 September 2023 and 27 September 2023, were included. Compared with applying the cover glass immediately, delaying the application of the cover glass for 5 s, 10 s, and 30 s resulted in average increases in the sperm concentration of 30.3%, 74.1%, and 107.5%, respectively (all P < 0.0001) and in the progressive motility (PR) of 17.7%, 30.8%, and 39.6%, respectively (all P < 0.0001). However, when the semen specimens were fixed with formaldehyde, a delay in the application of the cover glass for 5 s, 10 s, and 30 s resulted in an average increase in the sperm concentration of 6.7%, 10.8%, and 14.6%, respectively, compared with immediate application of the cover glass. The accumulation of motile sperm due to delays in the application of the cover glass is a significant source of error with the Makler counting chamber and should be avoided.
Humans
;
Male
;
Sperm Motility/physiology*
;
Sperm Count
;
Semen Analysis/methods*
;
Spermatozoa/physiology*
;
Time Factors
10.Clinical characteristics and survival analysis of pediatric Hodgkin lymphoma: a multicenter study.
Ying LIN ; Li-Li PAN ; Shao-Hua LE ; Jian LI ; Bi-Yun GUO ; Yu ZHU ; Kai-Zhi WENG ; Jin-Hong LUO ; Gao-Yuan SUN ; Yong-Zhi ZHENG
Chinese Journal of Contemporary Pediatrics 2025;27(6):668-674
OBJECTIVES:
To investigate the clinicopathological characteristics and prognostic factors of pediatric Hodgkin lymphoma (HL).
METHODS:
A retrospective analysis was conducted on the clinical data of children with newly diagnosed HL from January 2011 to December 2023 at four hospitals: Fujian Medical University Union Hospital, Fujian Medical University Zhangzhou Hospital, First Affiliated Hospital of Xiamen University, and Fujian Children's Hospital. Patients were categorized into low-risk (R1), intermediate-risk (R2), and high-risk (R3) groups based on HL staging and pre-treatment risk factors. The patients received ABVD regimen or Chinese Pediatric HL-2013 regimen chemotherapy. Early treatment response and long-term efficacy were assessed, and prognostic factors were analyzed using the Cox proportional hazards regression model.
RESULTS:
The overall complete response (CR) rates after 2 and 4 cycles of chemotherapy were 42% and 68%, respectively. Compared with the ABVD regimen group, patients treated with the HL-2013 regimen in the R1 group showed significantly higher CR rates after both 2 and 4 cycles (P<0.05). However, no statistically significant differences in CR rates were observed between the two regimens in the R2 and R3 groups (P>0.05). The 5-year event-free survival (EFS) rate, overall survival rate, and freedom from treatment failure rate were 83%±4%, 97%±2%, and 88%±4%, respectively. Cox analysis indicated that the presence of a large tumor mass at diagnosis and failure to achieve CR after 4 cycles of chemotherapy were independent risk factors for lower EFS rates (P<0.05).
CONCLUSIONS
Pediatric HL generally has a favorable prognosis. The presence of a large tumor mass at diagnosis and failure to achieve CR after 4 cycles of chemotherapy indicate poor prognosis.
Humans
;
Hodgkin Disease/pathology*
;
Male
;
Child
;
Female
;
Adolescent
;
Retrospective Studies
;
Child, Preschool
;
Antineoplastic Combined Chemotherapy Protocols/therapeutic use*
;
Prognosis
;
Proportional Hazards Models
;
Survival Analysis
;
Infant

Result Analysis
Print
Save
E-mail