1.Resistance of Aedes albopictus to common insecticides in Zhejiang Province, 2024
Qin-mei LIU ; Jin-na WANG ; Tian-qi LI ; Ming-yu LUO ; Zhou GUAN ; Zhen-yu GONG ; Ji-min SUN
Acta Parasitologica et Medica Entomologica Sinica 2026;33(2):96-100
Objective In order to understand the current resistance status of Aedes albopictus(Ae. albopictus) adult population to commonly used insecticides and the resistance dynamics development in Zhejiang Province and provide a theoretical basis for the scientific and rational use of hygienic insecticides. Methods Resistance determination was carried out using the diagnostic dose method(GB/T 26347-2010)recommended by WHO in the adult mosquito contact cylinder method to monitor the resistance of Ae. albopictus field populations in 11 cities and districts in Zhejiang Province in 2024. Results The monitoring result showed that adult Ae. albopictus in 11 areas were resistant or suspected resistant populations to both cis-cypermethrin and permethrin; suspected and resistant populations to the organophosphate insecticide malathion were as high as 81.82%; while suspected resistance to the carbamate insecticide residual carbofuran accounted for 45.45%, and the rest of the monitoring sites were sensitive to it. Conclusions The result suggest that the generalized resistance of Ae. albopictus populations to pyrethroids and organophosphorus insecticides in the field in Zhejiang Province needs to be highly emphasized. In future mosquito vector and mosquito-borne disease control, insecticides should be selected based on the resistance monitoring information, while following scientific guidelines for insecticide use.
2.Research and Application of Scalp Surface Laplacian Technique
Rui-Xin LUO ; Si-Ying GUO ; Xin-Yi LI ; Yu-He ZHAO ; Chun-Hou ZHENG ; Min-Peng XU ; Dong MING
Progress in Biochemistry and Biophysics 2025;52(2):425-438
Electroencephalogram (EEG) is a non-invasive, high temporal-resolution technique for monitoring brain activity. However, affected by the volume conduction effect, EEG has a low spatial resolution and is difficult to locate brain neuronal activity precisely. The surface Laplacian (SL) technique obtains the Laplacian EEG (LEEG) by estimating the second-order spatial derivative of the scalp potential. LEEG can reflect the radial current activity under the scalp, with positive values indicating current flow from the brain to the scalp (“source”) and negative values indicating current flow from the scalp to the brain (“sink”). It attenuates signals from volume conduction, effectively improving the spatial resolution of EEG, and is expected to contribute to breakthroughs in neural engineering. This paper provides a systematic overview of the principles and development of SL technology. Currently, there are two implementation paths for SL technology: current source density algorithms (CSD) and concentric ring electrodes (CRE). CSD performs the Laplace transform of the EEG signals acquired by conventional disc electrodes to indirectly estimate the LEEG. It can be mainly classified into local methods, global methods, and realistic Laplacian methods. The global method is the most commonly used approach in CSD, which can achieve more accurate estimation compared with the local method, and it does not require additional imaging equipment compared with the realistic Laplacian method. CRE employs new concentric ring electrodes instead of the traditional disc electrodes, and measures the LEEG directly by differential acquisition of the multi-ring signals. Depending on the structure, it can be divided into bipolar CRE, quasi-bipolar CRE, tripolar CRE, and multi-pole CRE. The tripolar CRE is widely used due to its optimal detection performance. While ensuring the quality of signal acquisition, the complexity of its preamplifier is relatively acceptable. Here, this paper introduces the study of the SL technique in resting rhythms, visual-related potentials, movement-related potentials, and sensorimotor rhythms. These studies demonstrate that SL technology can improve signal quality and enhance signal characteristics, confirming its potential applications in neuroscientific research, disease diagnosis, visual pathway detection, and brain-computer interfaces. CSD is frequently utilized in applications such as neuroscientific research and disease detection, where high-precision estimation of LEEG is required. And CRE tends to be used in brain-computer interfaces, that have stringent requirements for real-time data processing. Finally, this paper summarizes the strengths and weaknesses of SL technology and envisages its future development. SL technology boasts advantages such as reference independence, high spatial resolution, high temporal resolution, enhanced source connectivity analysis, and noise suppression. However, it also has shortcomings that can be further improved. Theoretically, simulation experiments should be conducted to investigate the theoretical characteristics of SL technology. For CSD methods, the algorithm needs to be optimized to improve the precision of LEEG estimation, reduce dependence on the number of channels, and decrease computational complexity and time consumption. For CRE methods, the electrodes need to be designed with appropriate structures and sizes, and the low-noise, high common-mode rejection ratio preamplifier should be developed. We hope that this paper can promote the in-depth research and wide application of SL technology.
3.Effect of ligation methods of inferior mesenteric artery on preserving left colic artery in lapa-roscopic radical resection of rectal cancer: a prospective randomized controlled study
Yang LUO ; Minhao YU ; Guangyao YE ; Feng GUO ; Yifei MU ; Ming ZHONG ; Zizhen ZHANG ; Lei GU
Chinese Journal of Digestive Surgery 2025;24(6):746-753
Objective:To investigate the effect of ligation methods of inferior mesenteric artery (IMA) on preserving left colic artery (LCA) in laparoscopic radical resection of rectal cancer.Methods:The prospective randomized controlled study was conducted. The clinical data of 864 patients who underwent laparoscopic radical resection of rectal cancer at Renji Hospital of Shanghai Jiaotong University School of Medicine from January 2020 to December 2024 were selected. Patients were randomly divided into the low ligation group and high ligation group using a random number table. Patients of the low ligation group underwent laparoscopic radical resection of rectal cancer with preserving LCA by low ligation of IMA and apical lymph node dissection, and patients of the high ligation group underwent laparoscopic radical resection of rectal cancer with traditional high ligation of IMA. Observation indicators: (1) grouping of the enrolled patients; (2) intraoperative conditions; (3) postoperative pathological examination; (4) postoperative recovery. Comparison of measurement data with normal distribution between groups was conducted using the independent sample t test. Comparison of count data between groups was conducted using the chi-square test or Fisher exact probability. Comparison of ordinal data between groups was conducted using the non-parametric test. Results:(1) Grouping of the enrolled patients. A total of 864 patients with rectal cancer who underwent laparoscopic radical resection of rectal cancer were screened for eligibility, including 410 males and 454 females, aged (63±11)years. All 864 patients were randomly divided into the low ligation group and high ligation group, with 432 patients in each group. There was no significant difference in gender, age, body mass index, carcinoembryonic antigen, distance from tumor to anal margin, diabetes, hypertension, neoadjuvant radiochemotherapy, IMA subtypes and IMA length between the two groups ( P>0.05), ensuring comparability. (2) Intraoperative conditions. All patients of the two groups successfully completed surgery, with no errors in blood vessel ligation during operation or conversion to open surgery. There was a significant difference in time of IMA dissection between the low ligation group and high ligation group [(31±11)minutes vs. (28±9)minutes, t=4.39, P<0.05], and there was no significant difference in total operation time, volume of intra-operative blood loss or prophylactic stoma rate between the two groups ( P>0.05). (3) Postopera-tive pathological examination. There was a significant difference in the number of lymph node dissected between the low ligation group and high ligation group (1.8±1.4 vs. 1.5±1.4, t=2.51, P<0.05), and there was no significant difference in tumor diameter, the total number of lymph node dissected, total lymph node positive status, No.253 lymph node positive status, TNM staging between the two groups ( P>0.05). (4) Postoperative recovery. The time to postoperative first flatus and the number of anastomotic leakage of patients in the low ligation group were (74±22)hours and 16 cases, versus (78±20)hours and 31 cases in the high ligation group, respectively, showing significant differences in the above indicators between the two groups ( t=2.52, χ2=5.06, P<0.05). There was no significant difference in the time to postoperative initial liquid food intake, duration of post-operative hospital stay, duration of abdominal drainage tube indwelling, duration of anal tube indwelling, postoperative wound infection, pulmonary infection, intestinal obstruction, or urinary dysfunction between the two groups ( P>0.05). None of patients in the two groups had readmission or death during the postoperative 30 days. Conclusion:Low ligation of IMA in laparoscopic radical resection of rectal cancer can guide precise LCA preservation, which is beneficial for accelerating the recovery of intestinal function and reducing the incidence of anastomotic leakage.
4.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
5.Research progress on role of necroptosis in chronic kidney disease
Ping QIU ; Shuo HUANG ; Qi-han LUO ; Qing MA ; Fu-zhe CHEN ; Zi-yi SHAN ; Yi-ming LIU ; Chang-yu LI
Chinese Pharmacological Bulletin 2025;41(5):816-820
Chronic kidney disease(CKD)is a chronic disease characterized by renal structural damage and dysfunction.At present,there is still a lack of effective therapeutic drugs and prevention and treatment methods for CKD in clinical practice.More and more studies have shown that necroptosis,as a new type of programmed cell death,plays a vital role in the onset and progression of CKD.Targeting key molecules in the necroptosis pathway,such as RIPK1,RIPK3 and MLKL,the development of small molecule inhibitors has become an emerging strategy for the treatment of CKD,and has shown significant potential to pro-tect the kidneys and alleviate renal fibrosis in a variety of in vitro and in vivo models.Therefore,this article summarizes the re-search progress of the mechanism of necroptosis in recent years,and focuses on the potential role of necroptosis in the pathogene-sis of CKD and the therapeutic potential of targeting this path-way,providing a new perspective and research direction for the prevention and treatment of CKD in the future.
6.Design and Development of Diagnosis Related Group(DRG)
Kaihua GAO ; Lü XUAN ; Yu HOU ; Jie LUO ; Ming LU ; Qinghong LI ; Hongquan YANG ; Xianchen MENG ; Xiaowei ZHU ; Mu HU ; Jing YANG
Chinese Health Economics 2025;44(4):46-49
In July 2024,the Diagnosis Related Groups(DRG)2.0 is released based on the Notice from the National Healthcare Security Administration on Issuing the DRG 2.0 and Deepening the Relevant Work.Compared with DRG 1.1,version 2.0 was established based on a wider range of suggestions regarding the Adjacent Diagnosis Related Groups(ADRG),Major Comorbidity or Complication(MCC),and Comorbidity or Complication(CC)from various institutions.A list of disease diagnoses and surgical operations that are not used as grouping rules was compiled,and grouping efficacy was further improved by upgrading the algorithms for MCC and CC with the help of AI.Meanwhile,it is necessary to pay more attention to the number of cases of ADRG,the better methods to list the MCC/CC,the suggestions of various doctors and continuously standardize the data and update the grouping scheme of DRG.
7.Effect of different detector combinations on head CT image quality and radiation dose in 320-row CT
Yun LUO ; Ming-ran SHAO ; Shang-wen YANG ; Yu-xiao WANG ; Kang SHI ; Ya-yun XU
Chinese Medical Equipment Journal 2025;46(4):57-62
Objective To compare the effects of different detector combinations of 320-row CT on the image quality and radiation dose of head CT to explore the feasibility of using a wide detector for head CT scanning.Methods Totally 100 patients underwent head CT scanning due to trauma or cerebrovascular disease at some hospital from June to August 2023 were collected prospectively and divided into group A and group B by using block randomization grouping method,with the length of the block group being 2 and 50 patients in each group.In group A,all the detectors had the widths at z-axis direction being 40×0.5 mm and head scanning was completed after multiple exposures;in group B,detector combinations with widths of 280×0.5 mm or 320×0.5 mm were chosen based on the patient's head size in the head-foot direction(z-axis direction),and head scanning was performed with a single-turn exposure.The remaining scanning and image reconstruction parameters in the two groups were kept completely consistent.The head image quality of the 2 groups was evaluated objectively and scored subjectively by 2 radiologists.The volume CT dose index(CTDIvol),dose length product(DLP)and exposure time of the 2 groups were recorded,and the effective dose(ED)was calculated.SPSS 22.0 software was used for statistical analysis.Results In terms of objective evaluation of image quality,at the level of the parietal skull group B had the CT value of gray matter,image noise and contrast to noise ratio(CNR)of the images higher than those of group A,and the differences were statistically significant(all P<0.05);at the level of the posterior skull group B had the CT values of gray and white matter,image noise and air noise lower while CNR higher than those of group A,and the differences were statistically significant(all P<0.05).In terms of subjective scoring of image quality,at the levels of parietal and posterior skull group A behaved better than group B,and the differences were statistically significant(all P<0.05).In group A 5 patients had obvious motion artifacts affecting the diagnosis and the image quality scores not higher than 2,and secondary scanning had to be carried out;In group B all the patients had no obvious motion artifacts and met the diagnosis requirements.When compared with group A Group B had the CTDIvol,DLP,ED and exposure time decreased by 17.44%,17.24%,17.48%and 85.53%,respectively,and the differences were statistically significant(all P<0.05).Conclusion A wide detector gains advantages over a 20 mm detector in image quality when 320-row CT is used for head CT scanning,with the diagnosis requirements satisfied.[Chinese Medical Equipment Journal,2025,46(4):57-62]
8.Research progress on role of necroptosis in chronic kidney disease
Ping QIU ; Shuo HUANG ; Qi-han LUO ; Qing MA ; Fu-zhe CHEN ; Zi-yi SHAN ; Yi-ming LIU ; Chang-yu LI
Chinese Pharmacological Bulletin 2025;41(5):816-820
Chronic kidney disease(CKD)is a chronic disease characterized by renal structural damage and dysfunction.At present,there is still a lack of effective therapeutic drugs and prevention and treatment methods for CKD in clinical practice.More and more studies have shown that necroptosis,as a new type of programmed cell death,plays a vital role in the onset and progression of CKD.Targeting key molecules in the necroptosis pathway,such as RIPK1,RIPK3 and MLKL,the development of small molecule inhibitors has become an emerging strategy for the treatment of CKD,and has shown significant potential to pro-tect the kidneys and alleviate renal fibrosis in a variety of in vitro and in vivo models.Therefore,this article summarizes the re-search progress of the mechanism of necroptosis in recent years,and focuses on the potential role of necroptosis in the pathogene-sis of CKD and the therapeutic potential of targeting this path-way,providing a new perspective and research direction for the prevention and treatment of CKD in the future.
9.Design and Development of Diagnosis Related Group(DRG)
Kaihua GAO ; Lü XUAN ; Yu HOU ; Jie LUO ; Ming LU ; Qinghong LI ; Hongquan YANG ; Xianchen MENG ; Xiaowei ZHU ; Mu HU ; Jing YANG
Chinese Health Economics 2025;44(4):46-49
In July 2024,the Diagnosis Related Groups(DRG)2.0 is released based on the Notice from the National Healthcare Security Administration on Issuing the DRG 2.0 and Deepening the Relevant Work.Compared with DRG 1.1,version 2.0 was established based on a wider range of suggestions regarding the Adjacent Diagnosis Related Groups(ADRG),Major Comorbidity or Complication(MCC),and Comorbidity or Complication(CC)from various institutions.A list of disease diagnoses and surgical operations that are not used as grouping rules was compiled,and grouping efficacy was further improved by upgrading the algorithms for MCC and CC with the help of AI.Meanwhile,it is necessary to pay more attention to the number of cases of ADRG,the better methods to list the MCC/CC,the suggestions of various doctors and continuously standardize the data and update the grouping scheme of DRG.
10.Effect of different detector combinations on head CT image quality and radiation dose in 320-row CT
Yun LUO ; Ming-ran SHAO ; Shang-wen YANG ; Yu-xiao WANG ; Kang SHI ; Ya-yun XU
Chinese Medical Equipment Journal 2025;46(4):57-62
Objective To compare the effects of different detector combinations of 320-row CT on the image quality and radiation dose of head CT to explore the feasibility of using a wide detector for head CT scanning.Methods Totally 100 patients underwent head CT scanning due to trauma or cerebrovascular disease at some hospital from June to August 2023 were collected prospectively and divided into group A and group B by using block randomization grouping method,with the length of the block group being 2 and 50 patients in each group.In group A,all the detectors had the widths at z-axis direction being 40×0.5 mm and head scanning was completed after multiple exposures;in group B,detector combinations with widths of 280×0.5 mm or 320×0.5 mm were chosen based on the patient's head size in the head-foot direction(z-axis direction),and head scanning was performed with a single-turn exposure.The remaining scanning and image reconstruction parameters in the two groups were kept completely consistent.The head image quality of the 2 groups was evaluated objectively and scored subjectively by 2 radiologists.The volume CT dose index(CTDIvol),dose length product(DLP)and exposure time of the 2 groups were recorded,and the effective dose(ED)was calculated.SPSS 22.0 software was used for statistical analysis.Results In terms of objective evaluation of image quality,at the level of the parietal skull group B had the CT value of gray matter,image noise and contrast to noise ratio(CNR)of the images higher than those of group A,and the differences were statistically significant(all P<0.05);at the level of the posterior skull group B had the CT values of gray and white matter,image noise and air noise lower while CNR higher than those of group A,and the differences were statistically significant(all P<0.05).In terms of subjective scoring of image quality,at the levels of parietal and posterior skull group A behaved better than group B,and the differences were statistically significant(all P<0.05).In group A 5 patients had obvious motion artifacts affecting the diagnosis and the image quality scores not higher than 2,and secondary scanning had to be carried out;In group B all the patients had no obvious motion artifacts and met the diagnosis requirements.When compared with group A Group B had the CTDIvol,DLP,ED and exposure time decreased by 17.44%,17.24%,17.48%and 85.53%,respectively,and the differences were statistically significant(all P<0.05).Conclusion A wide detector gains advantages over a 20 mm detector in image quality when 320-row CT is used for head CT scanning,with the diagnosis requirements satisfied.[Chinese Medical Equipment Journal,2025,46(4):57-62]


Result Analysis
Print
Save
E-mail