1.Assessment of Genotoxicity of Tissue Engineered Materials Based on Improved in vivo Hepatocyte Unscheduled DNA Synthesis(UDS)Assay
Luan-luan WANG ; Li HOU ; Xiang-yu CHU ; Zi-yi YANG ; Ling-xiao SUN ; Xiao-fei WANG ; Qiu-jin QU ; Jing XU ; Zeng-xiang LIU ; Xiao-xia SUN
Progress in Modern Biomedicine 2025;25(17):2740-2748
Objective:An in vivo mammalian hepatocyte Unscheduled DNA Synthesis(UDS)test was used to evaluate the genotoxicity of Cross-linked Sodium Hyaluronate Gel and Bone Repair Materials,providing experimental evidence for establishing a UDS testing method for medical devices and materials.Methods:0.9%sodium chloride injection and cottonseed oil were used as the solvent for test materials and negative control,respectively.N-dimethylnitrosamine(NDMA)was used as the positive control for the early sampling times,and 2-acetylaminofluorene(2-AAF)was used as the positive control for the late sampling times.SD rats were administered a single dose for toxic exposure,and liver tissues were collected at 4 h and 16 h,respectively.Hepatocytes were isolated using collagenase perfusion.After labeling with 5-ethynyl-2'-deoxyuridine(EdU),and the net average fluorescence intensity(NAFI)of cell nuclei and nucleoplasm was measured by fluorescence microscope.Data from 50 cells were used to analyze the DNA repair level.Results:Compared with the negative control groups,the positive control groups(NDMA and 2-AAF)showed highly statistically significant differences in NAFI(P<0.01),indicating successful induction of DNA damage.There was no statistically significant differences between the cross-linked sodium hyaluronate gel groups,bone repair material groups and the negative control group(P>0.05),suggesting that these materials did not significantly induce DNA damage under the experimental conditions.Conclusion:This study first applied EdU labeling technology to the in vivo hepatic UDS assay,achieving non-radioactive labeling through click chemistry reactions.Under the conditions of this study,cross-linked sodium hyaluronate gel and bone repair materials did not exhibit genotoxicity.In the follow-up,the sample range can be expanded and the observation period can be prolonged to further improve the genotoxicity evaluation system of medical devices.
2.Subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets
Qiu-jin QU ; Ling-xiao SUN ; Xiao-fei WANG ; Fu-yu ZHU ; Guo-xi CHE ; Jing XU ; Xiao-yan WANG ; Nai-shui HAN ; Xiao-xia SUN ; Chun-xia QIAO
Chinese Medical Equipment Journal 2025;46(10):29-35
Objective To evaluate the subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets using hydroxyethyl starch(HES)130/0.4 sodium chloride injection as an extraction medium.Methods Firstly,40 Sprague Dawley(SD)rats including 20 male and 20 female ones were seleted and randomly enrolled into a sample group and a control group by sex,with 20 ones in each group.Secondly,instead of plasma HES 130/0.4 sodium chloride injection was used to leach disposable plasma virus-inactivated blood transfusion sets to prepare the test solution by simulating clinical application such as lighting,adsorption and filtration and storage.Finally,the test solution and HES 130/0.4 sodium chloride injection were injected into the tail vein of the SD rats at a dose of 20 mL/kg for 28 d in the sample group and in the control group respectively,and the subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets and the feasibility of using HES 130/0.4 sodium chloride injection as the extraction medium to assess their subchronic systemic toxicity were evaluated with clinical observation,body mass monitoring,clinical pathology examination,gross necropsy and histopathology examination.Results The sample group and control group had no significant differences in mortality rates,clinical observation results,body mass,gross necropsy results,hematological and coagulation examination results and organ weight(all P>0.05);blood biochemical examinations showed the male rats in the sample group had the cholesterol(CHO)values higher while the creatinine(CR)values lower than those in the control group,with the differences being statistically significant(both P<0.05)and the two indexes within the range of the laboratory's historical reference data,and other blood biochemical indexes were not significantly different(all P>0.05);the sample group had the spleen weight-to-body mass ratios of the female rates lower significantly than those in the control group(P<0.05),and the ratios of other organ weight to body mass had significant differences(all P>0.05);histopathology examination showed slight pathological changes in liver,spleen and kidney of female rats and in spleen and kidney of male rats in the sample group,and the female and male rats in the control group had similar pathological changes found in the sample group,which might be caused by HES metabolites.Conclusion Disposable plasma virus-inactivated blood transfusion sets prove to have no significant subchronic systemic toxicity,and its feasible to use HES 130/0.4 sodium chloride injection as the extraction medium to evaluate the subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets.[Chinese Medical Equipment Journal,2025,46(10):29-35]
3.Assessment of Genotoxicity of Tissue Engineered Materials Based on Improved in vivo Hepatocyte Unscheduled DNA Synthesis(UDS)Assay
Luan-luan WANG ; Li HOU ; Xiang-yu CHU ; Zi-yi YANG ; Ling-xiao SUN ; Xiao-fei WANG ; Qiu-jin QU ; Jing XU ; Zeng-xiang LIU ; Xiao-xia SUN
Progress in Modern Biomedicine 2025;25(17):2740-2748
Objective:An in vivo mammalian hepatocyte Unscheduled DNA Synthesis(UDS)test was used to evaluate the genotoxicity of Cross-linked Sodium Hyaluronate Gel and Bone Repair Materials,providing experimental evidence for establishing a UDS testing method for medical devices and materials.Methods:0.9%sodium chloride injection and cottonseed oil were used as the solvent for test materials and negative control,respectively.N-dimethylnitrosamine(NDMA)was used as the positive control for the early sampling times,and 2-acetylaminofluorene(2-AAF)was used as the positive control for the late sampling times.SD rats were administered a single dose for toxic exposure,and liver tissues were collected at 4 h and 16 h,respectively.Hepatocytes were isolated using collagenase perfusion.After labeling with 5-ethynyl-2'-deoxyuridine(EdU),and the net average fluorescence intensity(NAFI)of cell nuclei and nucleoplasm was measured by fluorescence microscope.Data from 50 cells were used to analyze the DNA repair level.Results:Compared with the negative control groups,the positive control groups(NDMA and 2-AAF)showed highly statistically significant differences in NAFI(P<0.01),indicating successful induction of DNA damage.There was no statistically significant differences between the cross-linked sodium hyaluronate gel groups,bone repair material groups and the negative control group(P>0.05),suggesting that these materials did not significantly induce DNA damage under the experimental conditions.Conclusion:This study first applied EdU labeling technology to the in vivo hepatic UDS assay,achieving non-radioactive labeling through click chemistry reactions.Under the conditions of this study,cross-linked sodium hyaluronate gel and bone repair materials did not exhibit genotoxicity.In the follow-up,the sample range can be expanded and the observation period can be prolonged to further improve the genotoxicity evaluation system of medical devices.
4.Subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets
Qiu-jin QU ; Ling-xiao SUN ; Xiao-fei WANG ; Fu-yu ZHU ; Guo-xi CHE ; Jing XU ; Xiao-yan WANG ; Nai-shui HAN ; Xiao-xia SUN ; Chun-xia QIAO
Chinese Medical Equipment Journal 2025;46(10):29-35
Objective To evaluate the subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets using hydroxyethyl starch(HES)130/0.4 sodium chloride injection as an extraction medium.Methods Firstly,40 Sprague Dawley(SD)rats including 20 male and 20 female ones were seleted and randomly enrolled into a sample group and a control group by sex,with 20 ones in each group.Secondly,instead of plasma HES 130/0.4 sodium chloride injection was used to leach disposable plasma virus-inactivated blood transfusion sets to prepare the test solution by simulating clinical application such as lighting,adsorption and filtration and storage.Finally,the test solution and HES 130/0.4 sodium chloride injection were injected into the tail vein of the SD rats at a dose of 20 mL/kg for 28 d in the sample group and in the control group respectively,and the subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets and the feasibility of using HES 130/0.4 sodium chloride injection as the extraction medium to assess their subchronic systemic toxicity were evaluated with clinical observation,body mass monitoring,clinical pathology examination,gross necropsy and histopathology examination.Results The sample group and control group had no significant differences in mortality rates,clinical observation results,body mass,gross necropsy results,hematological and coagulation examination results and organ weight(all P>0.05);blood biochemical examinations showed the male rats in the sample group had the cholesterol(CHO)values higher while the creatinine(CR)values lower than those in the control group,with the differences being statistically significant(both P<0.05)and the two indexes within the range of the laboratory's historical reference data,and other blood biochemical indexes were not significantly different(all P>0.05);the sample group had the spleen weight-to-body mass ratios of the female rates lower significantly than those in the control group(P<0.05),and the ratios of other organ weight to body mass had significant differences(all P>0.05);histopathology examination showed slight pathological changes in liver,spleen and kidney of female rats and in spleen and kidney of male rats in the sample group,and the female and male rats in the control group had similar pathological changes found in the sample group,which might be caused by HES metabolites.Conclusion Disposable plasma virus-inactivated blood transfusion sets prove to have no significant subchronic systemic toxicity,and its feasible to use HES 130/0.4 sodium chloride injection as the extraction medium to evaluate the subchronic systemic toxicity of disposable plasma virus-inactivated blood transfusion sets.[Chinese Medical Equipment Journal,2025,46(10):29-35]
5.Necessity of blood hemocompatibility evaluation in medical devices with indirect contact with blood
Chun-xia QIAO ; Qiu-jin QU ; Li HOU ; Zeng-lin ZHAO ; Xiang-yu CHU ; Xiao-xia SUN
Chinese Medical Equipment Journal 2025;46(8):44-49
Objective To study the need for blood compatibility evaluation of medical devices that come into indirect contact with blood in order to accurately evaluate the risk of their interaction with blood.Methods Seven medical devices with indirect contact with blood were selected as samples including extension tubes of central venous catheters,port bodies of implantable drug delivery devices,infusion sets,receiving lines of dialysis equipment,auxiliary lines of left ventricular assist devices,blood monitors and catheter holders,with high-density polyethylene as the negative control,glass beads as the positive control and blank whole blood or plasma for the blank control.Partial thromboplastin time(PTT)test,platelet count test and hematology test(white blood cell and red blood cell count)were performed by direct contact method and indirect contact method,respectively.In the direct contact method,whole blood or plasma was in direct contact with the sample;while in the indirect contact method,whole blood or plasma was not in direct contact with the extraction solution,with no direct contact with the sample.Results With the indirect contact method the ratios(expressed as a percentage)of the PTT,platelate,WBC and RBC counts of the samples,positive and negative controls to those of the blank control were all higher than those with the direct contact method,and the indirect contact method had the sensitivity lower than that of the direct contact method.Conclusion Medical devices indirectly contacting blood have low risks for causing coagulation and platelet and hematologic adverse reactions,which are suggested to be evaluated for hemolysis testing only in case of the history of safe clinical use.[Chinese Medical Equipment Journal,2025,46(8):44-49]
6.Expert consensus on infection prevention and control of Creutzfeldt-Jakob disease in medical institutions
Tianxiang GE ; Yangyang JIA ; Chunhui LI ; Jianrong HUANG ; Xiujuan MENG ; Xiaodong GAO ; Jingping ZHANG ; Fu QIAO ; Lijuan XIONG ; Hui LIANG ; Wei LI ; Haiyan LOU ; Wenjuan WU ; Tianxin XIANG ; Jiansen CHEN ; Biao ZHU ; Kaijin XU ; Zhihui ZHOU ; Hongliu CAI ; Meihong YU ; Yan ZHANG ; Yanwan SHANGGUAN ; Haiting FENG ; Hangping YAO ; Lei GUO ; Tieer GAN ; Weihong ZHANG ; Jimin SUN ; Ye LU ; Qun LU ; Meng CAI ; Jin SHEN ; Yunsong YU ; Anhua WU ; Liu-yi LI ; Tingting QU
Chinese Journal of Infection Control 2025;24(4):437-450
Creutzfeldt-Jakob disease(CJD)is a rapidly progressive and fatal neurodegenerative disorder caused by prions,with certain infectivity and iatrogenic transmission risks.With the rapid progress and application of new dia-gnostic biomarkers and detection methods,as well as the construction and improvement of surveillance and reporting systems,the detection of CJD in patients domestically and internationally has shown an increasing trend year by year.Due to its long incubation period and heterogeneity of early symptoms,early identification and diagnosis of the disease is difficult,increasing the risk of transmission within medical institutions.Currently,there is a lack of con-sensus on the infection prevention and control of CJD.In order to timely identify and diagnose CJD as well as effec-tively block its transmission in medical institutions,this consensus summarizes 15 clinical concerns and formulates 24 specific recommendations based on the latest domestic and international research findings and clinical evidence,as well as combines with clinical practice,aiming to standardize healthcare-associated infection prevention and control measures for CJD and reduce its transmission risk in medical institutions.
7.Necessity of blood hemocompatibility evaluation in medical devices with indirect contact with blood
Chun-xia QIAO ; Qiu-jin QU ; Li HOU ; Zeng-lin ZHAO ; Xiang-yu CHU ; Xiao-xia SUN
Chinese Medical Equipment Journal 2025;46(8):44-49
Objective To study the need for blood compatibility evaluation of medical devices that come into indirect contact with blood in order to accurately evaluate the risk of their interaction with blood.Methods Seven medical devices with indirect contact with blood were selected as samples including extension tubes of central venous catheters,port bodies of implantable drug delivery devices,infusion sets,receiving lines of dialysis equipment,auxiliary lines of left ventricular assist devices,blood monitors and catheter holders,with high-density polyethylene as the negative control,glass beads as the positive control and blank whole blood or plasma for the blank control.Partial thromboplastin time(PTT)test,platelet count test and hematology test(white blood cell and red blood cell count)were performed by direct contact method and indirect contact method,respectively.In the direct contact method,whole blood or plasma was in direct contact with the sample;while in the indirect contact method,whole blood or plasma was not in direct contact with the extraction solution,with no direct contact with the sample.Results With the indirect contact method the ratios(expressed as a percentage)of the PTT,platelate,WBC and RBC counts of the samples,positive and negative controls to those of the blank control were all higher than those with the direct contact method,and the indirect contact method had the sensitivity lower than that of the direct contact method.Conclusion Medical devices indirectly contacting blood have low risks for causing coagulation and platelet and hematologic adverse reactions,which are suggested to be evaluated for hemolysis testing only in case of the history of safe clinical use.[Chinese Medical Equipment Journal,2025,46(8):44-49]
8.Clinical pathway for integrated traditional Chinese and Western medicine in the diagnosis and treatment of acute pancreatitis
Yuan ZHANG ; Hao WANG ; Haiyan YIN ; Shengwei JIN ; Bangjiang FANG ; Guiwei LI ; Xijing ZHANG ; Hongmei GAO ; Donghao WANG ; Changsong WANG ; Keliang XIE ; Lai JIANG ; Yan QU ; Zhaocai ZHANG ; Jianying KAN ; Daihua YU ; Junling LIU ; Jun LI ; Weiwei AN ; Yong CHEN ; Jianbo YU
Chinese Journal of Integrated Traditional and Western Medicine in Intensive and Critical Care 2025;32(3):257-261
Acute pancreatitis(AP)is a frequently encountered acute abdominal syndrome in clinical settings,and the integrated model of traditional Chinese and Western medicine(TCM-WM)has demonstrated notable advantages in the diagnosis and treatment of AP.To systematize and standardize clinical practices related to develop clinical pathway for integrated TCM-WM diagnosis and treatment of AP,which enhances the efficiency and quality of patient care.This pathway focuses on AP,a common acute and life-threatening disease within the digestive system,and outlines that the central pathological mechanism involves pancreatic injury and localized inflammation resulting from the abnormal activation of pancreatic enzymes.It has the characteristics of rapid onset,multiple causes,and complex manifestations.Severe cases can be life-threatening.At present,conventional treatments encompass a diverse range of modalities.Moreover,traditional Chinese medicine(TCM)holds distinct advantages in alleviating relevant symptoms,and TCM-WM is gaining increasing prevalence.To enhance the standardization and consistency of diagnostic and therapeutic practices,this clinical pathway clearly delineates the target patient population,which includes individuals diagnosed with abdominal pain disorder according to TCM and with AP in accordance with WM criteria,as well as the corresponding inclusion standards.The diagnostic framework integrates both TCM and WM guidelines,and further incorporates disease staging,severity grading,and syndrome differentiation to support a comprehensive and integrated diagnostic strategy.The treatment integrates approaches from both TCM and WM.Within the WM framework,interventions consist of basic supportive care,infection control,nutritional support,and the management of complications.In the context of TCM,the protocol includes syndrome differentiation and corresponding therapeutic strategies(Distinct syndrome patterns are identified and managed during the acute and convalescent phases),such as acupuncture and retention enema.This clinical pathway addresses multiple key components,including preventive strategies,post-treatment follow-up,criteria for evaluating therapeutic efficacy,admission and discharge,admission examination protocols,discharge criteria,and the rationale for deviations or withdrawal from the pathway.It is designed to provide a systematic and standardized reference framework for relevant clinical practices.
9.Predictive value of albumin,hemoglobin,and multifactorial model for poor postoperative prognosis in elderly patients with meningiomas
Yan-Yu GONG ; Hong QU ; Si-Zhe FENG ; Chun-Yong YU ; Jin-Wei DU ; Jin JIANG
Medical Journal of Chinese People's Liberation Army 2025;50(4):418-426
Objective To explore the predictive value of albumin,hemoglobin and multifactorial model for poor postoperative prognosis in elderly patients with meningioma.Methods A retrospective analysis was conducted on 253 elderly patients who underwent meningioma surgery and were transferred to the neurosurgical intensive care unit(NICU)at General Hospital of Northern Theater Command from January 2019 to September 2021,serving as the modeling cohort.Another 227 elderly patients who were treated in NICU after meningioma surgery from November 2021 to June 2023 were used as the validation cohort.Patients in the modeling cohort were categorized into good prognosis group[Glasgow Coma Scale(GCS)score>7,n=161]and poor prognosis group(GCS≤7,n=92)based on the GCS.Univariate and multifactorial logistic regression analyses were performed on the modeling cohort to identify independent risk factors,and a multifactorial model for predicting poor postoperative prognosis in elderly patients with meningioma was constructed based on these factors.The predictive efficacy and accuracy of the model were evaluated using the area under the receiver operating characteristic(ROC)curve(AUC),sensitivity,specificity,Hosmer-Lemeshow goodness-of-fit test,and calibration curves.The predictive value of postoperative albumin,hemoglobin,and the multifactorial models for postoperative prognosis in elderly meningioma patients was assessed using restricted cubic spline modeling(RCS),decision curves(DCA),and validated using an external validation cohort to assess the stability of the model.Results Meningioma WHO grade Ⅱand Ⅲ(OR=3.994,95%CI 1.963-8.126),postoperative hypoalbuminemia(OR=2.194,95%CI 1.079-4.462),and postoperative anemia(OR=2.117,95%CI 1.096-4.089)were identified as independent risk factors for poor postoperative prognosis in elderly meningioma patients(P<0.05),while the use of analgesic/sedative medications was a protective factor(OR=0.388,95%CI 0.201-0.748,P<0.05).The Hosmer-Lemeshow test indicated that the constructed multifactorial model had a good fit accuracy(P=0.161).The AUC for predicting poor postoperative prognosis in elderly meningioma patients for postoperative albumin and hemoglobin were 0.545(95%CI 0.472-0.617)and 0.632(95%CI 0.561-0.702),respectively,and showed a nonlinear dose-response relationship with prognosis(P<0.01).DCA analysis results showed that the net benefit rate of multifactorial model was higher than that of postoperative albumin and hemoglobin when the threshold probabilities were between 0.10 and 0.90.The AUC for predicting postoperative prognosis in the elderly meningioma patients in the modeling and validation cohorts were 0.810 and 0.819,respectively,and their calibration curves suggested good discrimination and accuracy.Conclusions Meningioma WHO grades Ⅱ and Ⅲ,postoperative anemia and hypoalbuminemia are independent risk factors for poor postoperative prognosis in elderly meningioma patients,while the use of analgesic/sedative drugs is a protective factor.The multifactorial model constructed based on these factors has a good predictive efficacy and credibility,and can be used as a reference for clinical decision-making.
10.Comparative analysis of the efficacy of laparoscopic hiatal hernia repair combined with Toupet or Dor fundoplication for esophageal hiatal hernia
Sheng-Chang LIANG ; Jin-Lian WANG ; Yi-Bin GUO ; Qi ZHANG ; Yu-Peng ZHANG ; Ting-Bao CAO ; Kun-Peng QU
Medical Journal of Chinese People's Liberation Army 2025;50(9):1122-1128
Objective To investigate the postoperative efficacy of laparoscopic hiatal hernia repair(LHHR)combined with Toupet or Dor fundoplication for the treatment of esophageal hiatal hernia(HH).Methods A retrospective analysis was conducted on the case data of HH patients who underwent LHHR combined with Toupet(Toupet group,n=53)and Dor(Dor group,n=53)fundoplication between December 2018 and December 2022 in Department of General Surgery of Gansu Provincial Hospital.Intraoperative and postoperative recovery outcomes of both groups were observed.We analyzed and compared the incidence of dysphagia and gastroesophageal reflux disease questionnaire(GERD-Q)scores at preoperative and postoperative intervals of 1 month,6 months,and 1 year.The incidence of postoperative complications and the 1-year recurrence rate were compared between the two groups.Additionally,factors influencing postoperative dysphagia within the first month were examined.Results The differences between the two groups in operation time,intraoperative bleeding,postoperative ventilation time,postoperative extubation time and hospitalization time were not statistically significant(P>0.05).There was no significant difference in the incidence of immediate postoperative dysphagia in two groups(P>0.05).Furthermore,the differences between the two groups in the incidence of postoperative complications,such as bloating,abdominal pain and diarrhea,were not statistically significant(P>0.05).The incidence of dysphagia in Toupet group was higher than that in Dor group at 1 month postoperatively,and the difference was statistically significant(P=0.017);but the difference in the incidence of dysphagia between the two groups at 6 months and 1 year postoperatively was not statistically significant(P=0.767,1.000).The results of binary logistic regression analysis showed that both surgical procedure(OR=2.613,95%CI 1.141-5.983,P=0.023)and esophageal contractile reserve function(OR=2.921,95%CI 1.203-7.095,P=0.018)were independent risk factors for the incidence of dysphagia in patients with HH at 1 month after surgery.Compared with the preoperative period,the GERD-Q symptom scores were lower in both groups at 1 month,6 months,and 1 year postoperatively,and the difference was statistically significant(P<0.05);but there was no statistically significant difference between the groups at the same time point(Fintergroup=0.334,P=0.565).The difference between the two groups in 1-year postoperative recurrence rates was not statistically significant(P>0.05).Conclusions LHHR combined with Toupet or Dor fundoplication are both safe and effective surgical procedures for the treatment of HH,with excellent reflux control,fewer complications and lower recurrence rates,but Toupet fundoplication is more likely to have postoperative short-term dysphagia than Dor fundoplication.

Result Analysis
Print
Save
E-mail