1.Three-dimensional finite element analysis of molar distalization with clear aligners with different thicknesses and edges
Yanan CHENG ; Jiazhi YU ; Yinchang LIU ; Jie WU ; Tong YU ; Lu WANG ; Xiaoguang LI
Chinese Journal of Tissue Engineering Research 2026;30(2):310-318
BACKGROUND:One of the advantages of clear aligner treatment is molar distalization.However,tooth tilting movement and loss of anterior anchorage may occur during treatment.There are few studies on whether these problems can be improved by selecting clear aligners with different thicknesses and edges to improve the clinical treatment effect.OBJECTIVE:To analyze the control ability of clear aligners with different thickness and edges on the central incisor,lateral incisor,and second molar when pushing the maxillary second molar distally by three-dimensional finite element analysis.METHODS:Three-dimensional finite element analysis models of bilateral maxillary second molar distalization with clear aligner,maxillary dentition,periodontal ligament,and alveolar bone with different thicknesses and margins were established by Mimics,Geomagic Wrap,3-matic and SolidWorks software,respectively.There were 16 combinations of four thicknesses(0.4,0.5,0.625,and 0.75 mm)and four margins(scallop,straight,straight extension 2 mm and straight extension 4 mm).The data were imported into Ansys Workbench software for design and solution.The mean value,peak value and distribution of the periodontal ligament equivalent stress of the second molar,the equivalent stress and the maximum initial displacement of the second molar,and the control ability of each appliance on the second molar,central incisor,and lateral incisor were analyzed.RESULTS AND CONCLUSION:(1)The mean equivalent stress of periodontal ligament of the second molar,the equivalent stress of the second molar and the maximum initial displacement of the second molar increased with the extension of the appliance edge and the increase of the thickness of the appliance in the 16 groups of models.(2)When the thickness of appliances was the same,the maximum equivalent stress of the second molar in the linear appliance group was the highest,and the maximum equivalent stress of the second molar in the linear extended appliance group was greater than that in the scallop appliance group.When the edge of the appliance was the same,the periodontal ligament equivalent stress peak of the second molar increased with the increase of the thickness of the appliance.The equivalent stress distribution in the periodontal ligament of the second molar in the linear extendable appliance group was more uniform than that in the scallop appliance group and the linear appliance group.(3)When the thickness of the appliance was the same,the scallop-shaped appliance had the worst control on the second molar.When the edge of the appliance was the same,with the increase of the thickness of the appliance,the control of the second molar by the linear extender appliance was gradually stronger than that by the linear appliance.The control of the central incisor was stronger and more stable with the linear extended 2 mm appliance,while the control of the lateral incisor was stronger and more stable with the linear appliance.(4)The results showed that when using clear aligners to push molars distally,extending the edge of the appliance could improve the control of the molars and reduce the tilting movement of the teeth.The design of a straight extension margin of 2 mm for the central incisor and a straight edge for the lateral incisor can enhance the control of the anchorage incisor and reduce the labial inclination of the anterior teeth.
2.Construction of Saikosaponin D Multifunctional Liposomes and Evaluation of Its Anti-liver Cancer Efficacy and Targeting
Kun YU ; Guochun YANG ; Yaliang JIANG ; Yunting XIAO ; Congxian WANG ; Qionge SUN ; Ziyue LI ; Yikun SHANG ; Yu MAO ; Xin CHENG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(9):205-216
ObjectiveTo construct a multifunctional liposomal delivery system by replacing cholesterol(Chol) in conventional liposomes with saikosaponin D(SSD) and modifying with poloxamer 407(P407) for co-delivery of curcumin(Cur). The system was evaluated for in vivo tumor targeting and inhibitory effects on mouse subcutaneous solid tumors. MethodsSingle-factor and orthogonal tests combined with information entropy weighting were used to optimize the formulation process of the liposome with encapsulation efficiency and absolute Zeta potential as indexes, and validation studies and liposomal characterization were performed. A subcutaneous solid tumor model was established by injecting H22 hepatocellular carcinoma cells subcutaneously into the dorsal surface of the right forelimb of mice. DiR-loaded traditional Chol liposomes(P407-DiR-Chol-LPs, PDCL) and novel SSD-based liposomes(P407-DiR-SSD-LPs, PDSL) were prepared by the optimized formulation process, and tail vein injection was performed to investigate the impact of SSD on liposome tumor targeting with small animal in vivo imaging. Mice were randomly divided into eight groups, including blank group, model group, free doxorubicin(DOX) group(2 mg·kg-1), free Cur group(8 mg·kg-1), free SSD group(10 mg·kg-1), P407-Cur-Chol-LPs(PCCL) group, P407-SSD-LPs(PSL) group, and P407-Cur-SSD-Lps(PCSL) group. Treatments were administered intraperitoneally every other day for seven doses. Antitumor efficacy and biocompatibility were evaluated by monitoring body weight change, organ indices, tumor volume and mass, relative tumor proliferation rate(T/C), and tumor growth inhibition rate(TGI). Histopathological analysis of liver, kidney, and tumor tissues was performed using hematoxylin-eosin(HE) staining. Serum levels of aspartate aminotransferase(AST), alanine aminotransferase (ALT), blood urea nitrogen(BUN), and creatinine(Crea)in mice were quantified by fully automated biochemical analyzer. ResultsOrthogonal test yielded optimal ratios of Cur, SSD, and P407 to soybean phosphatidylcholine(SPC) as 1∶25, 1∶20, and 1∶4. The optimized PCSL exhibited spherical morphology with a particle size of 179.15 nm, a Zeta potential of -47.25 mV, and an encapsulation efficiency of 96.40%. Its in vitro release profile conformed to first-order kinetics, demonstrating excellent storage stability and hemocompatibility. In vivo imaging revealed that the fluorescence signal in tumor tissues and the fluorescence intensity ratio between tumors and organs were significantly higher in the PDSL group than in the PDCL group(P<0.05, P<0.01). Among the treatment groups, PCSL group showed superior efficacy over free Cur group, free SSD group, PCCL group, and PSL group, with TGI>40% and T/C<60%, indicating pronounced anti-hepatocellular carcinoma effects(P<0.05, P<0.01). Histopathology and serum biochemistry indicated minimal hepatorenal toxicity and improved hepatic and renal function in PCSL-treated mice. ConclusionReplacing Chol with SSD in preparing multifunctional drug delivery systems not only stabilizes liposomes but also yields superior anti-hepatocellular carcinoma efficacy, achieving the effect of drug-excipient integration. Co-delivery of Cur via this system can be used for treating subcutaneous solid tumors in hepatocellular carcinoma, providing new insights and technical approaches for anti-hepatocellular carcinoma research and the meridian-guiding and messenger-directing theory in traditional Chinese medicine.
3.Research progress of biomaterial-mediated brain-computer interfaces in neural rehabilitation
Xiangxiang YU ; Jie SHI ; Yucheng CHEN ; Lifeng CHENG ; Liangcan HE ; Kai LI
Chinese Journal of Clinical Medicine 2026;33(2):213-220
Neurological disorders such as post-stroke hemiplegia, spinal cord injury, and Parkinson disease represent a major global health burden. Brain-computer interface (BCI), which creates direct communication pathways between the nervous system and external devices, offers a promising strategy for functional restoration. The long-term efficacy of such BCI fundamentally depends on the performance of biomaterials at the neural interface. Ideal materials must concurrently satisfy biocompatibility, electrical conductivity, enduring chemical stability, and mechanical compatibility with brain tissue. This review systematically outlines the application of conductive polymers, inorganic nanomaterials, natural biomaterials, and composites in BCI, with a focus on how advanced designs, such as bionic and encapsulated electrodes, improve signal fidelity and surgical feasibility through structural innovation. It further summarizes key material-modification techniques and analyzes the complex foreign-body response orchestrated by microglia, astrocytes, and peripheral immune cells. Finally, it provides insights into future research directions and clinical translation of BCI-based neurorehabilitation, while highlighting critical challenges including long-term biosafety and the establishment of standardized evaluation frameworks, aiming to bridge the gap between laboratory innovation and effective clinical deployment.
4.Heartbeat-evoked responses to cue-induced craving in heroin use disorder individuals
Dingming CHANG ; Yongxin CHENG ; Juan WANG ; Ruowan LI ; Fang DONG ; Kai YUAN ; Dahua YU
Chinese Journal of Clinical Medicine 2026;33(2):230-239
Objective To explore the differences in heartbeat-evoked response (HER) under drug-related cues and neutral cues in individuals with heroin use disorder (HUD), and analyze the correlation between HER potentials and immediate cue-induced craving scores. Methods Fifty HUD participants were recruited from the Chang’an Compulsory Isolation Drug Rehabilitation Center in Shaanxi Province from June to September 2024. Simultaneous acquisition of 64-channel electroencephalography (EEG) and electrocardiogram signals was performed. Twenty alternating segments of drug-related and neutral cue videos were presented, and participants rated their subjective craving after each segment using visual analogue scale (VAS) scores. Scalp EEG data were source analyzed to obtain cortical EEG signals and corresponding HER. Short-time Fourier transform was used to calculate the power spectral density (PSD) of EEG within a time window from 100 ms before the R-peak to 500 ms after it, using the R-peak as the time zero point. Cluster-based permutation testing was used to analyze PSD differences between drug-related and neutral cues in the HUD individuals. Pearson correlation analysis was performed to evaluate the correlation between HER potentials and VAS scores. Results In the 350–420 ms time window, HER potentials in the left posterior parietal, temporal, and posterior cingulate cortices were significantly lower under drug-related cues compared to neutral cues (P<0.01); in the 140–210 ms time window, HER potentials in the right prefrontal cortex were significantly higher under drug-related cues compared to neutral cues (P<0.01). Correlation analysis showed that HER potentials in the left temporal and left posterior cingulate cortices were significantly negatively correlated with VAS scores (P<0.05). Drug-related cues enhanced PSD of γ power (30–100 Hz) in salience network (fronto-insular), parietal and occipital regions (P<0.05). PSD integrations of low-γ power (40–60 Hz) in parietal region (350–400 ms) and high-γ power (70–100 Hz) in left salience network (fronto-parietal) and occipital regions (300–350 ms) were positively correlated with VAS scores (P<0.05). Conclusions Drug-related cues may modulate cortical activity related to heartbeat perception in HUD individuals, and such dynamic changes in both time and frequency domains are stably associated with subjective craving.
5.Three-dimensional finite element analysis of molar distalization with clear aligners with different thicknesses and edges
Yanan CHENG ; Jiazhi YU ; Yinchang LIU ; Jie WU ; Tong YU ; Lu WANG ; Xiaoguang LI
Chinese Journal of Tissue Engineering Research 2026;30(2):310-318
BACKGROUND:One of the advantages of clear aligner treatment is molar distalization.However,tooth tilting movement and loss of anterior anchorage may occur during treatment.There are few studies on whether these problems can be improved by selecting clear aligners with different thicknesses and edges to improve the clinical treatment effect.OBJECTIVE:To analyze the control ability of clear aligners with different thickness and edges on the central incisor,lateral incisor,and second molar when pushing the maxillary second molar distally by three-dimensional finite element analysis.METHODS:Three-dimensional finite element analysis models of bilateral maxillary second molar distalization with clear aligner,maxillary dentition,periodontal ligament,and alveolar bone with different thicknesses and margins were established by Mimics,Geomagic Wrap,3-matic and SolidWorks software,respectively.There were 16 combinations of four thicknesses(0.4,0.5,0.625,and 0.75 mm)and four margins(scallop,straight,straight extension 2 mm and straight extension 4 mm).The data were imported into Ansys Workbench software for design and solution.The mean value,peak value and distribution of the periodontal ligament equivalent stress of the second molar,the equivalent stress and the maximum initial displacement of the second molar,and the control ability of each appliance on the second molar,central incisor,and lateral incisor were analyzed.RESULTS AND CONCLUSION:(1)The mean equivalent stress of periodontal ligament of the second molar,the equivalent stress of the second molar and the maximum initial displacement of the second molar increased with the extension of the appliance edge and the increase of the thickness of the appliance in the 16 groups of models.(2)When the thickness of appliances was the same,the maximum equivalent stress of the second molar in the linear appliance group was the highest,and the maximum equivalent stress of the second molar in the linear extended appliance group was greater than that in the scallop appliance group.When the edge of the appliance was the same,the periodontal ligament equivalent stress peak of the second molar increased with the increase of the thickness of the appliance.The equivalent stress distribution in the periodontal ligament of the second molar in the linear extendable appliance group was more uniform than that in the scallop appliance group and the linear appliance group.(3)When the thickness of the appliance was the same,the scallop-shaped appliance had the worst control on the second molar.When the edge of the appliance was the same,with the increase of the thickness of the appliance,the control of the second molar by the linear extender appliance was gradually stronger than that by the linear appliance.The control of the central incisor was stronger and more stable with the linear extended 2 mm appliance,while the control of the lateral incisor was stronger and more stable with the linear appliance.(4)The results showed that when using clear aligners to push molars distally,extending the edge of the appliance could improve the control of the molars and reduce the tilting movement of the teeth.The design of a straight extension margin of 2 mm for the central incisor and a straight edge for the lateral incisor can enhance the control of the anchorage incisor and reduce the labial inclination of the anterior teeth.
6.Cage design-centric glider approach to full-endoscopic lumbar fusion: optimizing nerve root protection in facet-sparing and facet-resecting techniques
Yu-Chia HSU ; Hao-Chun CHUANG ; Yuan-Fu LIU ; Chao-Jui CHANG ; Yu-Meng HSIAO ; Yi-Hung HUANG ; Keng-Chang LIU ; Chien-Min CHEN ; Hyeun-Sung KIM ; Cheng-Li LIN
Asian Spine Journal 2026;20(2):343-353
Endoscopic transforaminal lumbar interbody fusion (TLIF) offers substantial advantages in the management of degenerative spinal diseases, including accelerated postoperative recovery. However, its technical complexity and steep learning curve pose risks for nerve root injury. Optimizing nerve root protection in full-endoscopic facet-sparing TLIF (FE fs-TLIF) and full-endoscopic facet-resecting TLIF (FE fr-TLIF) is essential for enhancing surgical safety. This study aimed to improve the nerve root protection in FE fs-TLIF and FE fr-TLIF by optimizing cage glider selection and insertion techniques based on the specific cage shape—banana-shaped or bullet-shaped. The goal was to ensure safe cage positioning and mitigate nerve root injury during discectomy, endplate preparation, and cage insertion. These strategies were validated through cadaveric simulations and clinical implementation. In FE fr-TLIF utilizing bullet-shaped (straight) cages, one-tip and two-tip cage gliders effectively protected the traversing nerve root by facilitating medial cage entry, thereby minimizing irritation of the exiting nerve root. Conversely, in FE fr-TLIF with banana-shaped cages, the lateral tilt of the cage holder during implantation required the use of a two-tip cage glider to protect the traversing and exiting nerve roots, thereby mitigating the potential risk of nerve irritation. In FE fs-TLIF, a one-tip cage glider is preferred for safeguarding the exiting nerve root, while the traversing root is inherently protected by the medial wall of the facet joint. The use of a two-tip cage glider in FE fs-TLIF can cause injury to the nerve root during glider insertion. In addition to the selection of cage gliders, improper cage insertion steps can also contribute to postoperative neurapraxia. The appropriate selection of cage gliders with corresponding insertion techniques is critical for nerve root protection in endoscopic TLIF. Tailoring these choices to the specific approach (FE fs-TLIF or FE fr-TLIF) and cage type (banana or bullet) enhances surgical safety and clinical outcomes.
7.SIRT5 Potentiates Hepatocarcinogenesis by Modulating Protein Acylation in Mice
Yu ZHANG ; Feng-Rui REN ; Jia-Yun LI ; Xiang-Yu CHEN ; Zi-Yi WANG ; Qi SUN ; Jun-Cheng ZHAO ; Ye ZHANG ; Zhen HUANG ; Hao HU ; Tao-Tao WEI ; Min XIAO
Progress in Biochemistry and Biophysics 2026;53(6):1712-1722
ObjectiveHepatocellular carcinoma (HCC) represents 90% of all primary liver cancers. The main risk factors associated with HCC include viral hepatitis (B and/or C), alcohol abuse, and metabolic dysfunction-associated steatotic liver disease (MASLD), which progressively advance to liver fibrosis, cirrhosis, and ultimately evolve into HCC. Surgical resection represents the most effective treatment for HCC, while recent advances in immunotherapy, including immune checkpoint inhibitors and adoptive cell therapies, have provided improved treatment prospects for patients with unresectable HCC. However, the complex metabolic heterogeneity of HCC limits the therapeutic efficacy. Metabolic intermediates acyl-CoA not only provide energy and substrates for numerous biochemical reactions but also serve as donors for protein lysine acylation, a major class of post-translational modification (PTM). Therefore, a deeper understanding of the molecular mechanisms underlying protein lysine acylation and hepatocarcinogenesis is urgently needed. MethodsThe levels of protein lysine acylation and silence information regulator 5 (SIRT5) expression levels in clinical HCC samples were analyzed by Western blot. Quantitative malonylome and succinylome of HCC samples were analyzed by antibody-based affinity enrichment coupled with tandem mass spectrometry. The proliferation of HCC cells was analyzed with Cell Counting Kit-8 (CCK-8) assays, the apoptosis was quantified by Annexin V-FITC/propidium iodide (PI) staining coupled with flow cytometry, and the ability of cells to migrate was assayed by Transwell assays. The enzymatic activity of glutathione S-transferase Mu 1 (GSTM1) was quantified. Transgenic mice with hepatic overexpression of SIRT5 were constructed using CRISPR-Cas9, and primary hepatocarcinogenesis was induced by administration of diethylnitrosamine. ResultsWestern blot analysis indicated that the expression level of SIRT5 was elevated in clinical samples from HCC patients, and the levels of lysine malonylation, glutarylation, and succinylation were significantly reduced in HCC tissues. Knockout of SIRT5 in MHCC-97H and MHCC-97L hepatoma cells suppressed cell proliferation, and increased the percentage of apoptotic cells significantly. Gene Ontology (GO) and Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway enrichment analyses of the differentially malonylome and succinylome of HCC samples revealed significant enrichment in two major classes of biological processes: core energy metabolism (e.g., glycolysis/gluconeogenesis, tricarboxylic acid metabolic process, fatty acid beta oxidation) and detoxification and oxidative stress response (e.g., response to toxic substance, chemical carcinogenesis, reactive oxygen species (ROS)). SIRT5 removes malonylation from lysine residues in GSTM1 and restores its detoxification activity, which is crucial for the survival of hepatocytes under stressed conditions. More importantly, in vivo experiment indicated that hepatic-specific overexpression of SIRT5 in mice accelerated diethylnitrosamine-induced liver fibrosis and hepatocarcinogenesis, indicating the critical role of SIRT5 in HCC progression. ConclusionThis study highlights the previously unrecognized SIRT5-GSTM1 axis as a key regulator in hepatocarcinogenesis, and suggests a potential target for the treatment of patients with HCC.
8.Pseudolaric Acid B-linked Double-network Hydrogel Alleviates Pruritus by Inhibiting The Growth of Staphylococcus aureus
Ye YOU ; Yan YANG ; Tong-Yu LI ; Cheng-Long CAI ; Ting WANG ; Chan ZHU ; Zong-Xiang TANG
Progress in Biochemistry and Biophysics 2026;53(6):1734-1745
ObjectiveThis study aimed to elucidate the mechanistic role of Staphylococcus aureus in the pathogenesis of atopic dermatitis (AD), a chronic inflammatory skin disorder characterized by pruritus and barrier dysfunction. A key focus was screening traditional Chinese medicine (TCM) active components with dual antibacterial and antipruritic efficacy, followed by systematic evaluation of their in vitro antibacterial activity. Additionally, a novel drug delivery system was constructed to enable localized efficient drug delivery, inhibiting S. aureus proliferation and alleviating its induced pruritus, thereby providing new strategies for targeted AD therapy. MethodsMale C57BL/6J mice aged 6-8 weeks (body weight 18-22 g) were used to establish an AD model via repeated oxazolone sensitization. On day 14, microbial samples were collected from the lesional area (1 cm²) using sterile cotton swabs, followed by vortex mixing, serial dilution, and plating on 5% sheep blood agar plates (incubated at 37°C for 24 h). Single colonies with complete transparent β-hemolytic zones were isolated and identified as vancomycin-intermediate S. aureus (VISA) via 16S rRNA sequencing. An S. aureus mono-infection animal model was then established by applying gauze saturated with bacterial suspension (McFarland turbidity 0.1) to the nape and back skin of mice. The pruritic phenotype and inflammatory cell infiltration induced by S. aureus were evaluated using comprehensive approaches including behavioral assays (e.g., scratching frequency recording), hematoxylin-eosin (HE) staining, and toluidine blue staining. The in vitro antibacterial efficacy of the TCM monomer pseudolaric acid B (PAB) and double network hydrogel (DN) was separately assessed by disk diffusion assay, while the minimum inhibitory concentration (MIC) of PAB was determined via broth dilution method. Further validation of the pharmacodynamic characteristics of the composite system (PAB@DN, composed of PAB and DN) was conducted through behavioral assays, HE staining, and dermatitis scoring, with its drug release profile evaluated by mass spectrometry analysis. Based on scratching behavioral analysis and dermatitis scoring, the optimal ratio and concentration of PAB@DN were optimized. ResultsThe S. aureus load in AD lesional tissues was significantly higher than in normal skin ((5.3±0.33)×10⁶ CFU vs. (3.6±0.26)×10⁷ CFU, P<0.001). In the S. aureus mono-infection group, mice exhibited a 6.7-fold increase in scratching frequency compared to the control group. HE staining revealed marked epidermal thickening ((10.4±2.39) μm vs. (85.6±1.95) μm, P<0.000 1), and toluidine blue staining showed a 23-fold increase in mast cell degranulation. Pseudolaric acid B exhibited a significant concentration-dependent inhibitory effect onS. aureus growth, with its in vitro antibacterial effect being 57% that of the antibiotic cefepime (inhibition zone diameter: PAB (1.885±0.036) cm vs. cefepime (3.636±0.005) cm, P<0.000 1) and a minimum inhibitory concentration (MIC) of 1 g/L. The carrier double network hydrogel (DN) itself lacked direct antibacterial activity (no significant difference in inhibition zone diameter compared to the control) but effectively ameliorated the dry symptoms of AD-like lesions. The PAB@DN composite system demonstrated a synergistic effect compared to individual components, resulting in a 50% reduction in scratching behavior, an 86% decrease in dermatitis score, and a 60% reduction in epidermal thickening. It also reduced the S. aureus load in mouse skin by approximately 34%, with the optimal effective formulation being PAB at 1 g/L loaded onto DN. ConclusionS. aureus colonization plays a critical driving role in the onset and progression of AD. Using an S. aureus infection model, this study confirmed that the pseudolaric acidB-hydrogel composite delivery system (PAB@DN) can effectively alleviate S. aureus-induced pruritus and skin damage, providing experimental evidence for microbiota-targeted therapy of AD.
9.Interpretation of 2024 ESC guidelines for the management of elevated blood pressure and hypertension
Yu CHENG ; Yiheng ZHOU ; Yao LÜ ; ; Dongze LI ; Lidi LIU ; Peng ZHANG ; Rong YANG ; Yu JIA ; Rui ZENG ; Zhi WAN ; Xiaoyang LIAO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(01):31-40
The European Society of Cardiology (ESC) released the "2024 ESC guidelines for the management of elevated blood pressure and hypertension" on August 30, 2024. This guideline updates the 2018 "Guidelines for the management of arterial hypertension." One notable update is the introduction of the concept of "elevated blood pressure" (120-139/70-89 mm Hg). Additionally, a new systolic blood pressure target range of 120-129 mm Hg has been proposed for most patients receiving antihypertensive treatment. The guideline also includes numerous additions or revisions in areas such as non-pharmacological interventions and device-based treatments for hypertension. This article interprets the guideline's recommendations on definition and classification of elevated blood pressure and hypertension, and cardiovascular disease risk assessment, diagnosing hypertension and investigating underlying causes, preventing and treating elevated blood pressure and hypertension. We provide a comparison interpretation with the 2018 "Guidelines for the management of arterial hypertension" and the "2017 ACC/AHA guideline on the prevention, detection, evaluation, and management of high blood pressure in adults."
10.Predictive Modeling of Symptomatic Intracranial Hemorrhage Following Endovascular Thrombectomy: Insights From the Nationwide TREAT-AIS Registry
Jia-Hung CHEN ; I-Chang SU ; Yueh-Hsun LU ; Yi-Chen HSIEH ; Chih-Hao CHEN ; Chun-Jen LIN ; Yu-Wei CHEN ; Kuan-Hung LIN ; Pi-Shan SUNG ; Chih-Wei TANG ; Hai-Jui CHU ; Chuan-Hsiu FU ; Chao-Liang CHOU ; Cheng-Yu WEI ; Shang-Yih YAN ; Po-Lin CHEN ; Hsu-Ling YEH ; Sheng-Feng SUNG ; Hon-Man LIU ; Ching-Huang LIN ; Meng LEE ; Sung-Chun TANG ; I-Hui LEE ; Lung CHAN ; Li-Ming LIEN ; Hung-Yi CHIOU ; Jiunn-Tay LEE ; Jiann-Shing JENG ;
Journal of Stroke 2025;27(1):85-94
Background:
and Purpose Symptomatic intracranial hemorrhage (sICH) following endovascular thrombectomy (EVT) is a severe complication associated with adverse functional outcomes and increased mortality rates. Currently, a reliable predictive model for sICH risk after EVT is lacking.
Methods:
This study used data from patients aged ≥20 years who underwent EVT for anterior circulation stroke from the nationwide Taiwan Registry of Endovascular Thrombectomy for Acute Ischemic Stroke (TREAT-AIS). A predictive model including factors associated with an increased risk of sICH after EVT was developed to differentiate between patients with and without sICH. This model was compared existing predictive models using nationwide registry data to evaluate its relative performance.
Results:
Of the 2,507 identified patients, 158 developed sICH after EVT. Factors such as diastolic blood pressure, Alberta Stroke Program Early CT Score, platelet count, glucose level, collateral score, and successful reperfusion were associated with the risk of sICH after EVT. The TREAT-AIS score demonstrated acceptable predictive accuracy (area under the curve [AUC]=0.694), with higher scores being associated with an increased risk of sICH (odds ratio=2.01 per score increase, 95% confidence interval=1.64–2.45, P<0.001). The discriminatory capacity of the score was similar in patients with symptom onset beyond 6 hours (AUC=0.705). Compared to existing models, the TREAT-AIS score consistently exhibited superior predictive accuracy, although this difference was marginal.
Conclusions
The TREAT-AIS score outperformed existing models, and demonstrated an acceptable discriminatory capacity for distinguishing patients according to sICH risk levels. However, the differences between models were only marginal. Further research incorporating periprocedural and postprocedural factors is required to improve the predictive accuracy.

Result Analysis
Print
Save
E-mail