1.Study on secondary metabolites of Penicillium expansum GY618 and their tyrosinase inhibitory activities
Fei-yu YIN ; Sheng LIANG ; Qian-heng ZHU ; Feng-hua YUAN ; Hao HUANG ; Hui-ling WEN
Acta Pharmaceutica Sinica 2025;60(2):427-433
Twelve compounds were isolated from the rice fermentation extracts of
2.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
4.Screening key genes of PANoptosis in hepatic ischemia-reperfusion injury based on bioinformatics
Lirong ZHU ; Qian GUO ; Jie YANG ; Qiuwen ZHANG ; Guining HE ; Yanqing YU ; Ning WEN ; Jianhui DONG ; Haibin LI ; Xuyong SUN
Organ Transplantation 2025;16(1):106-113
Objective To explore the relationship between PANoptosis and hepatic ischemia-reperfusion injury (HIRI), and to screen the key genes of PANoptosis in HIRI. Methods PANoptosis-related differentially expressed genes (PDG) were obtained through the Gene Expression Omnibus database and GeneCards database. Gene ontology (GO), Kyoto Encyclopedia of Genes and Genomes (KEGG), and Gene Set Enrichment Analysis (GSEA) were used to explore the biological pathways related to PDG. A protein-protein interaction network was constructed. Key genes were selected, and their diagnostic value was assessed and validated in the HIRI mice. Immune cell infiltration analysis was performed based on the cell-type identification by estimating relative subsets of RNA transcripts. Results A total of 16 PDG were identified. GO analysis showed that PDG were closely related to cellular metabolism. KEGG analysis indicated that PDG were mainly enriched in cellular death pathways such as apoptosis and immune-related signaling pathways such as the tumor necrosis factor signaling pathway. GSEA results showed that key genes were mainly enriched in immune-related signaling pathways such as the mitogen-activated protein kinase (MAPK) signaling pathway. Two key genes, DFFB and TNFSF10, were identified with high accuracy in diagnosing HIRI, with areas under the curve of 0.964 and 1.000, respectively. Immune infiltration analysis showed that the control group had more infiltration of resting natural killer cells, M2 macrophages, etc., while the HIRI group had more infiltration of M0 macrophages, neutrophils, and naive B cells. Real-time quantitative polymerase chain reaction results showed that compared with the Sham group, the relative expression of DFFB messenger RNA in liver tissue of HIRI group mice increased, and the relative expression of TNFSF10 messenger RNA decreased. Cibersort analysis showed that the infiltration abundance of naive B cells was positively correlated with DFFB expression (r=0.70, P=0.035), and the infiltration abundance of M2 macrophages was positively correlated with TNFSF10 expression (r=0.68, P=0.045). Conclusions PANoptosis-related genes DFFB and TNFSF10 may be potential biomarkers and therapeutic targets for HIRI.
5.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
6.Advances of Metal-Organic Framework Stationary Phases for Gas Chromatographic Separations
Yan JIN ; Wen-Bo LI ; Yu-Chen ZHU ; Bin ZHAO ; Lei LI ; Dan ZHENG ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(1):1-13
Metal-organic frameworks(MOFs)are porous materials composed of metal ions or metal clusters and organic ligands by coordination,which have the advantages of large specific surface area,good thermal stability and adjustable pore size,and have a promising application in gas chromatographic separation.In recent years,MOFs materials have been used as stationary phases for gas chromatography mainly including ZIF,MIL,UiO-66,HKUST-1,IRMOFs,etc.Based on the molecular sieve effect,van der Waals forces,hydrogen bonding and π-π interactions,the pore size,pore microenvironment,unsaturated metal site and special functional group of the MOFs stationary phase materials can be specifically designed and regulated.MOFs materials as stationary phases have unique separation performance for n-alkanes and their isomers,aromatic compounds and their isomers,alcohols/ketones/aldehydes and their isomers,and chiral compounds.The combination of organic polymers and novel nanomaterials with MOFs materials can improve the separation performance and stability of MOFs.Therefore,MOFs materials are expected to be the promising stationary phase that can be applied to gas separation in complex environments.In this article,the research advances of various stationary phases based on MOFs for gas chromatography in recent years were reviewed.The separation performance and separation mechanism of MOFs stationary phases for mixed gas samples were discussed,and the development trends in the future were prospected.
7.A Pneumatic Micro-valve with Sandwich Structure Based on Micro-electro-mechanical System
Shao-Jie MA ; Wen-Bo LI ; Yu-Chen ZHU ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(5):758-764
In this study,an ON/OFF type micro-valve with a sandwich(glass-silicon-glass)structure was designed and fabricated based on the micro-electro-mechanical system(MEMS)technique.The deformable membrane of this micro-valve was prepared on the silicon on insulator(SOI)substrate and sealed using Si-Si bonding and anodic bonding methods.The micro-valve had high-temperature stability and was suitable for integration with other gas chromatography components.The deformable membrane with a thickness of 10 μm was processed on the top silicon of the SOI substrate.The flow control of the micro-valve could be achieved by changing the driving pressure applied to the deformable membrane to deform it.Compared with polymer membranes,the deformable membrane prepared on the top layer silicon of SOI had better temperature stability and could be released using the deep reactive ion etching technique after silicon-silicon bonding,avoiding deformation during the preparation process.In addition,due to the small gap between the membrane and the inlet/outlet holes,the dead volume of the microvalve was very small.The test results indicated that the micro-valve achieved flow control and ON/OFF functions with good repeatability.
8.A Monolithic Integrated Gas Chromatography Chip with Gas Chromatographic Column and Helium Discharge Ionization Detector
Yu-Chen ZHU ; Shao-Jie MA ; Wen-Bo LI ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(7):1064-1071
A monolithic integrated gas chromatography chip,consisting of a micro gas chromatography column(μGCC)and a micro helium discharge ionization detector(μHDID)was proposed.The chip was fabricated using micro electromechanical system(MEMS)technique,and its sensitivity was improved from two aspects.On one hand,open tubular column was selected as the separation device,and the auxiliary helium channel width of μHDID was modulated based on the microchannel width of the μGCC to match the flow rates of μHDID and μGCC.On the other hand,the electrode structure inside the μHDID collection zone was optimized,a bias electrode group around the collection electrode was constructed,and the ion collection efficiency was improved.After coating HKUST-1 as the stationary phase,the monolithic integrated gas chromatography chip could achieve baseline separation and detection of light hydrocarbon gas mixture(methane,ethane,propane,andn-butane),with a detection limit for propane as low as 25 pg.The chip could carried out test under temperature-programmed conditions,with a resolution of 9.24 for ethane and propane.
9.A Micro Gas Chromatographic Column with Large Surface Area Based on Anodization
Shao-Jie MA ; Wen-Bo LI ; Yu-Chen ZHU ; Bo-Xin CHEN ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(10):1607-1614
A micro gas chromatographic column with mesoporous surface micro column array prepared by anodization method was proposed.A porous support layer with a characteristic pore size of about 30 nm inside the chromatographic column was prepared in situ using anodization method,and a uniform alumina stationary phase was deposited on the mesoporous support layer using atom layer deposition(ALD)technique.The existence of a mesoporous support layer increased surface area of the chromatographic column,thereby increasing the total amount of stationary phase loading and enhancing column capacity,which facilitated chromatographic separation.The test results showed that the porous support layer significantly reduced the longitudinal molecular diffusion and mass transfer resistance of the micro gas chromatographic column,and significantly increased the number of theoretical plates(n-nonane increased by 290.2%).Furthermore,column efficiency of the chromatographic column was less affected by flow rate,which was conducive to rapid separation of heavy hydrocarbon mixtures.
10.Exploration of the application of vehicle-mounted 5G remote mobile robotic surgical system in thyroid surgery
Meng WANG ; Wen TIAN ; Qingqing HE ; Guolou LI ; Jian ZHU ; Xiaodong MA ; Wei WEI ; Qiongqiong TAN ; Jinzhi HU ; Yingying WANG ; Peng ZHOU ; Gang WANG ; Yixin LIU ; Hejun WANG ; Yu LIU ; Lihu LIU
International Journal of Surgery 2025;52(1):28-32
Objective:To investigate the feasibility and safety of implementing a domestic vehicle-mounted remote mobile robotic surgical system in thyroid surgery applications, integrated with 5G communication technology.Methods:Using the main system located on the vehicle-mounted mobile robot operating platform of the 960th Hospital of PLA Joint Logistics Support Force and the slave system of Weifang Traditional Chinese Hospital, the remote radical thyroidectomy 5G communication technology, and analyze the clinical and information transmission data of two female patients who underwent remote mobile robot thyroid cancer surgery on October 21, 2024 at Weifang Traditional Chinese Medicine Hospital.Results:The remote radical thyroidectomy was conducted by the robosurgeons utilizing a vehicle-mounted mobile robotic surgical system, and the procedure was successfully completed without necessitating intermediate open surgery. The operation durations for patient 1 and patient 2 were 135 minutes and 108 minutes, respectively, with 7 and 13 lymph nodes dissected, respectively. The average delay in surgical data transmission was recorded at 61.9 milliseconds, with no instances of signal interruption or frame loss. The procedure proceeded smoothly, without any jamming, and the audio and video transmissions were consistently clear. Follow up for 21 days after surgery showed no complications such as hoarseness, skin damage, or lymphatic fistula.Conclusion:The implementation of a vehicle-mounted remote mobile robotic surgery system for thyroid surgery has demonstrated safety and feasibility. Furthermore, the utilization of the 5G network offers rapid data transmission and minimal latency, closely approximating the therapeutic efficacy of traditional robotic thyroidectomy.

Result Analysis
Print
Save
E-mail