1.Comparative study of single-criteria and multi-criteria optimization modes for cervical cancer VMAT radiotherapy plans by Raystation planning system
Gang LI ; Yu-song LONG ; Jun-wen TAN ; Xian-tao HE ; Yong-fu FENG ; Zhan-yu WANG
Chinese Medical Equipment Journal 2025;46(9):39-44
Objective To carry out cervical cancer VMAT radiotherapy planning respectively with the single-criteria optimization(SCO)and multi-criteria optimization(MCO)modes of Raystation 4.7 planning system,and to provide references for selecting optimization mode clinically by comparing and analyzing the dosimetric parameters such as target dose distribution,exposure dose to organ at risk(OAR),monitor unit and beam-on time.Methods Ten cervical cancer patients who attended some hospital from February to December 2022 were retrospectively selected,and some VMAT plans were designed for them with the SCO mode of Raystation 4.7 planning system and then enrolled into a SCO group;other VMAT plans were redesigned with the MCO mode under the premise the setup conditions such as machine model and shot field angle were unchanged,and divided into a MCO group.The two groups were compared in terms of maximum dose(D2%),minimum dose(D98%),homogeneity index(HI)and conformity index(CI)of the planning target volume(PTV),beam-on time,monitor unit and exposure doses to OARs including bladder V50 Gy,V40 Gy and V30 Gy,rectum V50 Gy,V40 Gy and V30 Gy,small intestine V50 Gy,V40 Gy and V30 Gy and left and right femur V50 Gy,V40 Gy and V30 Gy.SPSS 22.0 software was used for statistical analysis.Results Both the two groups met clinical requirements.There were no significant differences between the two groups in D98%,CI,small intestine V50 Gy and left and right femur V40 Gy(P>0.05).The MCO group had the values of HI,D2%,V50 Gy,V40 Gy and V30 Gy,rectum V50 Gy,V40 Gy and V30 Gy,small intestine V40 Gy and V30 Gy and left and right femur V30 Gy lower than those of the SCO group,with the differences being statistically significant(P<0.05).The SCO group had less monitor units and shorter beam-on time when compared with the MCO group,with the differences being statistically siginificant(P<0.05).Conclusion When compared with the SCO mode-based VMAT plans,the MCO mode-based VMAT plans significantly decrease the exposure doses and volume to rectum,bladder and small intestine and raise the PTV homogeneity,while lower the treatment efficiency to some extent by increased monitor units and prolonged beam-on time.[Chinese Medical Equipment Journal,2025,46(9):39-44]
2.Quality inspection of ultrasound soft tissue cutting hemostatic equipment
Jing HUANG ; Qi-di SUN ; Ao-wen DUAN ; Li XU ; Heng-yu LONG ; Hai-jiang ZHU ; He-hua ZHANG
Chinese Medical Equipment Journal 2025;46(10):49-53
Objective To carry out quality inspection of the ultrasound soft tissue cutting hemostatic equipment to ensure its safety and effectiveness.Methods Five brands of ultrasound soft tissue cutting hemostatic equipment were selected and noted as test equipment A,test equipment B,test equipment C,test equipment D and test equipment E,which underwent quality inspection in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current based on YY/T 0644-2008 Ultrasonics-surgical systems—Measurement and declaration of the basic output characteristics,YY/T 1750-2020 Ultrasonic surgical equipmetn for soft tissue excision and hemostasia and GB 9706.1-2020 Medical electrical equipment—Part 1:General requirements for basic safety and essential performance.Results The test data of the five brands in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current met the technical requirements of YY/T 0644-2008,YY/T 1750-2020,GB 9706.1-2020.Conclusion The quality inspection of the ultrasound soft tissue cutting hemostatic equipment contributes to enhancing the accuracy and stability of the equipment and decreasing the risk during its clinical application.[Chinese Medical Equipment Journal,2025,46(10):49-53]
3.Troubleshooting of YLY-020Y acidic oxidation potential water generator:Three case reports
Jing-jing LU ; Jing WU ; Zhen-le FEI ; Xiao-long LI ; Yu ZHANG ; Min HE
Chinese Medical Equipment Journal 2025;46(10):118-120
Three failures of YLY-020Y acidic oxidation potential water generator were introduced,and the causes and specific troubleshooting measures were explored.References were provided for engineers to treat similar failures.[Chinese Medical Equipment Journal,2025,46(10):118-120]
4.Research on application of a teaching model based on three-dimensional visualization technology in cul-tivating clinical decision-making ability for severe pancreatitis in standardized residency training
Modern Hospital 2025;25(10):1637-1640
Objective To explore the application effect of three-dimensional(3D)visualization technology in teaching rounds for severe pancreatitis during standardized residency training.Methods Forty residents undergoing standardized training in the Department of Pancreatic Surgery,Union Hospital,Tongji Medical College,Huazhong University of Science and Technolo-gy from February 2024 to February 2025 were selected as the study subjects and randomly divided into a traditional teaching rounds group(n=20)and a 3 D visualization teaching rounds group(n=20).The traditional group followed the standard teach-ing rounds procedure,while the 3D visualization group incorporated 3D visualization models into the standard teaching rounds.A questionnaire survey was used to assess the satisfaction of the two groups with the teaching rounds.Results Analysis of the questionnaire results showed that the 3D visualization teaching group had significantly higher scores than the traditional teaching group in overall satisfaction(4.20±0.77 vs.3.10±1.17),helpfulness in understanding the disease(4.55±0.69 vs.3.20±1.20),teaching interactivity(4.40±0.68 vs.3.05±1.19),improvement in clinical thinking ability(4.50±0.51 vs.3.05±1.23),helpfulness in clinical decision-making(4.35±0.67 vs.3.20±1.32),and assessment scores(88.55±6.35 vs.81.10±7.17),with all differences being statistically significant(P<0.05).Conclusion The 3D visualization technology en-hances residents' learning interest in teaching rounds for severe pancreatitis during standardized training,while also strengthening their understanding and mastery of professional knowledge.This teaching method received positive feedback and can be promoted in teaching rounds.
5.Research on application of a teaching model based on three-dimensional visualization technology in cul-tivating clinical decision-making ability for severe pancreatitis in standardized residency training
Modern Hospital 2025;25(10):1637-1640
Objective To explore the application effect of three-dimensional(3D)visualization technology in teaching rounds for severe pancreatitis during standardized residency training.Methods Forty residents undergoing standardized training in the Department of Pancreatic Surgery,Union Hospital,Tongji Medical College,Huazhong University of Science and Technolo-gy from February 2024 to February 2025 were selected as the study subjects and randomly divided into a traditional teaching rounds group(n=20)and a 3 D visualization teaching rounds group(n=20).The traditional group followed the standard teach-ing rounds procedure,while the 3D visualization group incorporated 3D visualization models into the standard teaching rounds.A questionnaire survey was used to assess the satisfaction of the two groups with the teaching rounds.Results Analysis of the questionnaire results showed that the 3D visualization teaching group had significantly higher scores than the traditional teaching group in overall satisfaction(4.20±0.77 vs.3.10±1.17),helpfulness in understanding the disease(4.55±0.69 vs.3.20±1.20),teaching interactivity(4.40±0.68 vs.3.05±1.19),improvement in clinical thinking ability(4.50±0.51 vs.3.05±1.23),helpfulness in clinical decision-making(4.35±0.67 vs.3.20±1.32),and assessment scores(88.55±6.35 vs.81.10±7.17),with all differences being statistically significant(P<0.05).Conclusion The 3D visualization technology en-hances residents' learning interest in teaching rounds for severe pancreatitis during standardized training,while also strengthening their understanding and mastery of professional knowledge.This teaching method received positive feedback and can be promoted in teaching rounds.
6.Heterologous Expression,Purification and Enzymatic Characterization of Xylitol Dehydrogenase from the Thermophilic Fungus Talaromyces emersonii
Er MENG ; Cong QU ; Ke YI ; Hui-Min LI ; Xin-Yi DUAN ; Zhe-Yuan ZHANG ; Shao-Long HE ; Yu-Tao LUO ; Lei WU ; Dong-Yi ZHANG ; Chang-Jun LIU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(7):1007-1018
The xylitol dehydrogenase(XDH)is a crucial enzyme involved in the xylose utilization in pentose-catabolizing yeasts and fungi.In addition to producing xylulose,XDH can also be employed to develop a biosensor for monitoring xylitol concentration.In this study,the gene encoding the thermophilic fungus Talaromyces emersonii XDH(TeXDH)was heterologously expressed in Escherichia coli BL21(DE3)at 16 ℃ in the soluble form.Recombinant TeXDH with high purity was purified by using a Ni-NTA affinity column.Size-exclusion chromatography and SDS-PAGE analysis demonstrated that the puri-fied recombinant TeXDH exists as a native trimer with a molecular mass of approximately 116 kD,and is composed of three identical subunits,each with a molecular weight of around 39 kD.The TeXDH strictly preferred NAD+as a coenzyme to NADP+.The optimal temperature and pH of the TeXDH were 40 ℃and 10.0,respectively.After EDTA treatment,the enzyme activity of TeXDH decreased to 43.26%of the initial enzyme activity,while the divalent metal ions Mg2+or Ca2+could recover the enzyme activity of TeXDH,reaching 103.32%and 110.69%of the initial enzyme activity,respectively,making them the optimal divalent metal ion cofactors for TeXDH enzyme.However,the divalent metal ions of Mn2+,Ni2+,Cu2+,Zn2+,Co2+,and Cd2+significantly inhibited the activity of TeXDH.ICP-MS and molecular doc-king studies revealed that 1 mol/L of TeXDH bound 2 mol/L Zn2+ions and 1 mol/L Mg2+ion.Further-more,TeXDH exhibited a high specificity for xylitol,laying the foundation for the development of future xylitol biosensors.
7.A prospective randomized controlled study on 3D-printed porous bioceramic artificial bone and artificial bone substitutes in the treatment of limb bone defect
Taoran WANG ; Zhuojing LUO ; Long BI ; Jiakai GAO ; Xiang HE ; Jingdi CHEN ; Jingzhuo JIA ; Hui ZHANG ; Yu WANG
Chinese Journal of Orthopaedics 2025;45(20):1298-1304
Objective:To compare the safety and efficacy of 3D-printed porous bioceramic artificial bone and artificial bone substitutes in the treatment of limb bone defects.Methods:A total of 220 patients with post-traumatic limb bone defects admitted to Xijing Hospital Affiliated to Air Force Medical University of the Chinese People's Liberation Army (34 cases), the Third Hospital of Hebei Medical University (60 cases), Xi'an Honghui Hospital (28 cases), the Third Hospital of Southern Medical University (18 cases), Changsha Third Hospital (28 cases), Foshan Traditional Chinese Medicine Hospital (16 cases), Foshan Fuxing Chancheng Hospital (12 cases), and Henan Provincial Orthopaedic Hospital (24 cases) from May 2022 to October 2023 were included as research subjects. According to the manufacturing method of the bone graft material, the subjects were randomly divided into the 3D printed porous bioceramic artificial bone group (3D printing group) and the artificial bone substitute group (non-3D printing group) at a ratio of 1:1 by the envelope method. Adverse events that might be related to the surgery were selected through correlation evaluation and classified as abnormal laboratory indicators, systemic or other site symptoms and abnormalities, and local symptoms and abnormalities of the affected limb. The safety of the two groups was compared. The bone graft fusion rate, bone defect repair and healing rate, and short form 12 (SF-12) score of the two groups were calculated to evaluate the postoperative recovery.Results:Thirty-two cases were excluded (4 cases refused to use their data after reconsideration, 7 cases were not used after preoperative assessment, and 21 cases exceeded the standard for body mass index and laboratory indicators upon re-examination). A total of 188 cases were randomly divided into the 3D printing group and the non-3D printing group according to the random method, with 94 cases in each group. Among them, 11 cases in the 3D printing group and 9 cases in the non-3D printing group dropped out due to loss to follow-up. Finally, 168 cases completed the follow-up, including 83 cases in the 3D printing group and 85 cases in the non-3D printing group. In the 3D printing group, there were 53 males and 30 females, with an average age of 47.9±12.7 years; in the non-3D printing group, there were 53 males and 32 females, with an average age of 48.6±12.9 years. A total of 51 cases in the two groups experienced adverse events related to the surgery, including 13 cases of abnormal laboratory indicators (5 cases in the 3D printing group and 8 cases in the non-3D printing group), 15 cases of systemic or other site symptoms and abnormalities (9 cases in the 3D printing group and 6 cases in the non-3D printing group), and 23 cases of local symptoms and abnormalities of the affected limb (13 cases in the 3D printing group and 10 cases in the non-3D printing group). There was no statistically significant difference in the incidence of adverse events between the two groups ( P>0.05). The bone graft fusion rates of the 3D printing group and the non-3D printing group at 6 months after surgery were 99%(82/83) and 99%(84/85), respectively, and the bone defect repair and healing rates were 89%(74/83) and 89%(76/85), respectively. At the time of 12 months after surgery, the bone graft fusion rates were 99%(82/83) and 99%(84/85), respectively, and the bone defect repair and healing rates were 94%(78/83) and 92%(78/85), respectively. There was no statistically significant difference in the bone graft fusion rate and bone defect repair and healing rate between the two groups ( P>0.05). The SF-12 scores during the screening period were 27.82±2.96 points and 27.22±4.23 points in the 3D printing group and the non-3D printing group, respectively, and at 3 months after surgery were 28.08±3.13 points and 27.64±3.16 points, at 6 months after surgery were 29.42±3.10 points and 28.55±3.45 points, and at 12 months after surgery were 29.78±2.80 points and 29.58±2.94 points, respectively. There was no statistically significant difference between the groups ( P>0.05). Both groups of surgeries were successfully completed without any serious surgical or bone graft-related complications. Conclusion:The safety and efficacy of 3D-printed porous bioceramic artificial bone in the treatment of limb bone defects are not significantly different from those of currently clinically applied artificial bone substitutes.
8.Quality inspection of ultrasound soft tissue cutting hemostatic equipment
Jing HUANG ; Qi-di SUN ; Ao-wen DUAN ; Li XU ; Heng-yu LONG ; Hai-jiang ZHU ; He-hua ZHANG
Chinese Medical Equipment Journal 2025;46(10):49-53
Objective To carry out quality inspection of the ultrasound soft tissue cutting hemostatic equipment to ensure its safety and effectiveness.Methods Five brands of ultrasound soft tissue cutting hemostatic equipment were selected and noted as test equipment A,test equipment B,test equipment C,test equipment D and test equipment E,which underwent quality inspection in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current based on YY/T 0644-2008 Ultrasonics-surgical systems—Measurement and declaration of the basic output characteristics,YY/T 1750-2020 Ultrasonic surgical equipmetn for soft tissue excision and hemostasia and GB 9706.1-2020 Medical electrical equipment—Part 1:General requirements for basic safety and essential performance.Results The test data of the five brands in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current met the technical requirements of YY/T 0644-2008,YY/T 1750-2020,GB 9706.1-2020.Conclusion The quality inspection of the ultrasound soft tissue cutting hemostatic equipment contributes to enhancing the accuracy and stability of the equipment and decreasing the risk during its clinical application.[Chinese Medical Equipment Journal,2025,46(10):49-53]
9.Troubleshooting of YLY-020Y acidic oxidation potential water generator:Three case reports
Jing-jing LU ; Jing WU ; Zhen-le FEI ; Xiao-long LI ; Yu ZHANG ; Min HE
Chinese Medical Equipment Journal 2025;46(10):118-120
Three failures of YLY-020Y acidic oxidation potential water generator were introduced,and the causes and specific troubleshooting measures were explored.References were provided for engineers to treat similar failures.[Chinese Medical Equipment Journal,2025,46(10):118-120]
10.Treating Type 2 Diabetic Nephropathy by Down-regulating NOX4 to Inhibit the Oxidative Stress Pathway in Mesenchymal Stem Cells
Shu-Qi FENG ; Guo-Rong JIN ; Qun-Hang XUE ; Min HE ; Ze-Hang WANG ; Jia-Xin YAO ; Long CHEN ; Yu-Jiao WANG ; An-Xiu ZHANG ; Sheng HE ; Bing-Rui ZHOU ; Jun XIE
Chinese Journal of Biochemistry and Molecular Biology 2025;41(5):730-740
Diabetic nephropathy(DN)is a serious complication of diabetes mellitus and a leading cause of end-stage renal diseases.In DN patients,key pathological mechanisms include proteinuria,glomerulo-sclerosis,and fibrosis,largely driven by poor glycemic control and oxidative stress caused by prolonged hyperglycemia.This stress damages renal podocytes and triggers inflammatory mesenchymal infiltration of renal tubular cells,exacerbating the progression of proteinuria and fibrosis.Human umbilical cord-de-rived mesenchymal stem cells(hUC-MSCs)offer promising potential for treating DN due to their strong anti-oxidative properties.In this study,we developed a DN mouse model and treated the mouse via tail vein injections of hUC-MSCs(1×106 cells/mouse).The results indicated that hUC-MSCs significantly lowered fasting blood glucose levels(22.5±3.0 vs 14.7±1.1,P<0.01)and improved glucose toler-ance,as shown by intraperitoneal glucose tolerance test(IPGTT)results(P<0.05).Additionally,the renal function improved in hUC-MSCs-treated mice,with marked reductions in oxidative stress markers,including blood urea nitrogen(BUN),urinary creatinine(Ucr),urinary protein(PRO),superoxide dismutase(SOD),and malondialdehyde(MDA)(P<0.05).Histological analyses through hematoxy-lin-eosin(H&E),Periodic Acid-Schiff(PAS),and Sirius red staining demonstrated alleviation of glo-merular mesangial hyperplasia,glomerular hypertrophy,and tubular inflammation.Furthermore,hUC-MSCs treatment downregulated the expression of oxidative stress-related proteins,such as NADPH oxi-dase 4(NOX4)and thioredoxin-interacting protein(TXNIP),and reduced reactive oxygen species(ROS)production(P<0.05).Meanwhile,human renal cortical proximal tubule epithelial cells(HK-2 cells)were selected for validation in vitro experiments using high glucose treatment followed by super-natants of hUC-MSCs(MSC-CM),and Western blotting showed that the expression of both NOX4 and TXNIP was inhibited(P<0.05)and ROS expression was reduced.In conclusion,hUC-MSC treatment effectively lowered blood glucose levels and improved renal function in DN mice,likely through the sup-pression of NOX4 expression and TXNIP-mediated oxidative stress.

Result Analysis
Print
Save
E-mail