1.Clinical Efficacy of Qi-regulating and Phlegm-removing Method(Liu Junzitang Combined with Linggang Wuwei Jiangxintang) in Treating AECOPD with Increased EOS
Renjie HUANG ; Wangqin YU ; Wuyinuo TANG ; Hong SONG ; Lyuyuan HE ; Wenbo LIN ; Guanyi WU ; Hang HUANG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(3):149-156
ObjectiveTo assess the efficacy and safety of the Qi-regulating and phlegm-removing method(Liu Junzitang Combined with Linggang Wuwei Jiangxintang) for treating acute exacerbations of chronic obstructive pulmonary disease (AECOPD) with increased eosinophils (EOS). MethodsSixty-eight AECOPD patients with increased EOS who were hospitalized in the Department of Pulmonary Diseases of Jinhua Traditional Chinese Medicine Hospital from April 2023 to April 2024 were recruited and randomly assigned to an experimental group (EG) or a control group (CG). Both groups received conventional Western medicine, with the EG additionally receiving Liujunzitang and Linggan Wuwei Jiangxintang. The therapeutic efficacy indicators were measured after the treatment. The main therapeutic efficacy indicators included partial pressure of oxygen (PaO2) and partial pressure of carbon dioxide (PaCO2). The secondary efficacy indicators included the TCM symptom scores, the COPD Assessment Test (CAT) score, the Modified Medical Research Council (mMRC) Dyspnea Scale score, and the length of hospital stay. The indicators were measured at baseline and on days 3 and 7 of intervention. The safety was evaluated based on the adverse events. ResultsBaseline characteristics were not statistically different between the two groups. Compared with CG, EG showed no significant difference in PaO2 (P=0.773), PaCO2 (P=0.632) and or CAT score (P=0.336) at on day 3 but better PaO2 (P=0.004), PaCO2 (P=0.008), and CAT score (P=0.013) were significantly better at on day 7. Compared with CGAfter treatment, EG had lower TCM syndrome scores of than CG EG on day 3 (P=0.005) and day 7 were significantly decreased (P0.001). There was no significant difference in mMRC score between the two groups on day 3 (P=0.514) and day 7 (P=0.176) as wasor the length of hospital stay (P=0.915). The generalized linear mixed model (GLMM) showed that compared with CG, EG had significant improvements over time in PaO2, PaCO2, TCM syndrome symptom scores, CAT score, and mMRC score. ConclusionRegulating qi Qi and removing phlegm combined with conventional Western medicine can significantly alleviateimprove the clinical symptoms and improve the lung function of AECOPD patients with increased EOS increased AECOPDwhich has and demonstrates good safety.
2.Clinical Efficacy of Qi-regulating and Phlegm-removing Method(Liu Junzitang Combined with Linggang Wuwei Jiangxintang) in Treating AECOPD with Increased EOS
Renjie HUANG ; Wangqin YU ; Wuyinuo TANG ; Hong SONG ; Lyuyuan HE ; Wenbo LIN ; Guanyi WU ; Hang HUANG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(3):149-156
ObjectiveTo assess the efficacy and safety of the Qi-regulating and phlegm-removing method(Liu Junzitang Combined with Linggang Wuwei Jiangxintang) for treating acute exacerbations of chronic obstructive pulmonary disease (AECOPD) with increased eosinophils (EOS). MethodsSixty-eight AECOPD patients with increased EOS who were hospitalized in the Department of Pulmonary Diseases of Jinhua Traditional Chinese Medicine Hospital from April 2023 to April 2024 were recruited and randomly assigned to an experimental group (EG) or a control group (CG). Both groups received conventional Western medicine, with the EG additionally receiving Liujunzitang and Linggan Wuwei Jiangxintang. The therapeutic efficacy indicators were measured after the treatment. The main therapeutic efficacy indicators included partial pressure of oxygen (PaO2) and partial pressure of carbon dioxide (PaCO2). The secondary efficacy indicators included the TCM symptom scores, the COPD Assessment Test (CAT) score, the Modified Medical Research Council (mMRC) Dyspnea Scale score, and the length of hospital stay. The indicators were measured at baseline and on days 3 and 7 of intervention. The safety was evaluated based on the adverse events. ResultsBaseline characteristics were not statistically different between the two groups. Compared with CG, EG showed no significant difference in PaO2 (P=0.773), PaCO2 (P=0.632) and or CAT score (P=0.336) at on day 3 but better PaO2 (P=0.004), PaCO2 (P=0.008), and CAT score (P=0.013) were significantly better at on day 7. Compared with CGAfter treatment, EG had lower TCM syndrome scores of than CG EG on day 3 (P=0.005) and day 7 were significantly decreased (P0.001). There was no significant difference in mMRC score between the two groups on day 3 (P=0.514) and day 7 (P=0.176) as wasor the length of hospital stay (P=0.915). The generalized linear mixed model (GLMM) showed that compared with CG, EG had significant improvements over time in PaO2, PaCO2, TCM syndrome symptom scores, CAT score, and mMRC score. ConclusionRegulating qi Qi and removing phlegm combined with conventional Western medicine can significantly alleviateimprove the clinical symptoms and improve the lung function of AECOPD patients with increased EOS increased AECOPDwhich has and demonstrates good safety.
3.Seamless corneal limbal stem cell transplantation combined with bandage soft contact lens for the treatment of pterygium
International Eye Science 2026;26(3):534-539
AIM: To investigate the clinical efficacy of seamless corneal limbal stem cell transplantation combined with bandage soft contact lens in the treatment of pterygium.METHODS: A retrospective collection was conducted on patients with pterygium admitted to the hospital from January 2020 to January 2025. They were divided into two groups according to different treatment methods. Group A received seamless corneal limbal stem cell transplantation surgery combined with bandage soft contact lens, while group B received simple seamless corneal limbal stem cell transplantation surgery. The complete repair and healing of corneal epithelium, ocular comfort and corneal refractive status at different time points after surgery were compared between the two groups, and the occurrence of postoperative complications in the two groups was recorded.RESULTS: This study included 120 cases(120 eyes)of patients with pterygium, including 60 cases(60 eyes)in the group A and 60 cases(60 eyes)in the group B. Group A had an age of 51.88±5.22 years, with 33 males and 27 females. Group B had an age of 52.48±6.00 years, with 30 males and 30 females. The complete repair and healing rate of corneal epithelium in the group A was higher than that in the group B at 1 and 2 wk after surgery(all P<0.05). At 1 and 2 wk after surgery, the scores of the eye comfort assessment table in both groups decreased compared to the day of surgery, and the group A was lower than the group B at all time points(all P<0.05). At 1 and 3 mo after surgery, the surface asymmetry index(SAI), corneal astigmatism(CA), and corneal surface regularity index(SRI)of the corneal topography in both groups decreased compared to preoperative values, and the group A was lower than the group B at all time points(all P<0.05). The incidence of postoperative complications in the group A was slightly lower than that in the group B, but the difference was not statistically significant(all P>0.05).CONCLUSION: The seamless corneal limbal stem cell transplantation surgery combined with bandage soft contact lens treatment can promote postoperative corneal epithelial healing in patients with pterygium, increase short-term eye comfort after surgery, improve short-term corneal refractive status after surgery, and reduce the occurrence of postoperative complications to a certain extent.
4.Response to the letter to the editor: Interpreting meta-analyses of biportal endoscopic decompression for lumbar spinal stenosis
Alexander YU ; Mark KURAPATTI ; Ryan HOANG ; James HONG ; Nancy SHRESTHA ; Ryan STADLER ; Peter CAMPBELL ; Junho SONG ; Joshua LEE ; Samuel K. CHO
Asian Spine Journal 2026;20(2):409-410
5.Associated factors of osteoporosis and the impact of osteoporosis on all-cause mortality in incident hemodialysis older patients
Seunghye LEE ; Yoomee KANG ; Yu Ah HONG ; Sung Joon SHIN ; Soon Hyo KWON ; Sungjin CHUNG ; Young Youl HYUN ; Sang Heon SONG ; Jae Won YANG ; Won Min HWANG ; Jang-Hee CHO ; Kyung Don YOO ; In O SUN ; Gang-Jee KO ; Byung Chul YU ; Hyunsuk KIM ; Woo Yeong PARK ; Tae Won LEE ; Dong Jun PARK ; Eunjin BAE ;
Kidney Research and Clinical Practice 2026;45(1):110-119
Background:
With the aging population and advancements in medical care worldwide, the number of older patients with end-stage kidney disease continues to rise. This study aimed to identify factors associated with osteoporosis and osteopenia in older patients undergoing incident hemodialysis and assess their impact on mortality.
Methods:
We analyzed a large multicenter retrospective cohort of patients aged ≥70 years undergoing incident hemodialysis to identify factors associated with osteoporosis using logistic regression analysis and to assess the association of death with osteoporosis and osteopenia using Cox multivariable analysis.
Results:
Among 710 patients, 39.0% and 19.6% had osteoporosis and osteopenia, respectively. Osteoporosis was significantly associated with female sex, a history of fractures, and the absence of phosphate binder use. During a median follow-up of 36.8 months, 348 participants (58.8%) died. Mortality rates were the highest in the osteoporosis group (79.8%), followed by the osteopenia (77.2%) and normal bone mineral density (BMD) groups (35.2%). Cox regression analysis revealed that even after adjusting for covariates, the osteoporosis group was significantly associated with a higher mortality risk than the normal BMD group. Osteoporosis at the start of hemodialysis was significantly associated with higher mortality.
Conclusion
We should consider the importance of bone health in patients undergoing incident hemodialysis and pay attention to the use of phosphate binders and fracture prevention.
6.Impact of obesity on renal function in elderly Korean adults: a national population-based cohort study
Jihyun YANG ; Hui Seung LEE ; Chi-Yeon LIM ; Hyunsuk KIM ; Sungjin CHUNG ; Soon Hyo KWON ; Jang-Hee CHO ; Kyung Don YOO ; Woo Yeong PARK ; In O SUN ; Byung Chul YU ; Gang-Jee KO ; Jae Won YANG ; Won Min HWANG ; Sang Heon SONG ; Sung Joon SHIN ; Yu Ah HONG ; Eunjin BAE ; Young Youl HYUN
Kidney Research and Clinical Practice 2026;45(1):65-76
Background:
Obesity is a well-known risk factor for chronic kidney disease and its progression. However, the impact of obesity on the renal function of the elderly population is uncertain. We investigated the association between obesity and renal outcomes in the elderly.
Methods:
We analyzed 130,504 participants from the Korean National Health Insurance Service-Senior cohort. Obesity was classified according to body mass index (BMI), sex-specific waist circumference (WC), and the presence of metabolic syndrome. The primary outcome was renal function decline, defined as a decline in the estimated glomerular filtration rate (eGFR) of at least 50% from baseline or new-onset end-stage renal disease.
Results:
During a follow-up period of 559,531.1 person-years (median, 4.3 years), 2,486 participants (19.0%; incidence rate of 4.44 per 1,000 person-years) showed renal function decline. A multivariate Cox proportional hazards model revealed that BMI/WC was not associated with renal function decline. However, the group with metabolic syndrome had a significantly increased risk of renal function decline compared to the group without metabolic syndrome (adjusted hazard ratio [HR], 1.24; 95% confidence interval [CI], 1.13–1.36). Compared with the non-metabolic syndrome group, the adjusted HRs (95% CI) for participants with one through five components were 0.96 (0.84–1.11), 1.10 (0.96–1.27), 1.24 (1.06–1.45), 1.37 (1.12–1.66), and 1.99 (1.42–2.79), respectively (p for trend < 0.001).
Conclusion
In elderly Korean adults, metabolic syndrome and the number of its components were associated with a higher risk of renal function decline, but BMI or WC was not significant.
7.Multi-level Characteristic Extraction and Analysis of Ink-enhanced Latent Fingerprint Using Optical and Electrochemical Visualization Methods
Yan-Feng ZHANG ; Hong-Yu CHEN ; Lu LIU ; Song GENG ; Mei-Qin ZHANG
Chinese Journal of Analytical Chemistry 2025;53(4):579-589,中插9-中插11
Due to the immaturity of visualization and quantitative analysis methods,the utilization rate of level 3 characteristics is seriously insufficient.In this work,based on the wet-membrane method and scanning electrochemical microscopy(SECM),and the introduction of conductive black ink to enhance the visualization effect,a systematic level 3 feature quantitative method was developed.Firstly,the feasibility and effect of the multi-level characteristics extraction strategy of latent fingerprints was investigated.Then,the influences of various deposition conditions on the level 3 features were explored.The results showed that the higher the deposition pressure,the wider the ridges,and the smaller the pore size.Moreover,excessive oil content could cause the pore size to be smaller and even been covered.Subsequently,the quantitative method was established from various pore characteristics such as pore number,pore activity,pore size,pore-to-pore distance and pore-to-pore angle.The stability of the level 3 features(pore number,pore-to-pore distance and pore-to-pore angle)was confirmed via repeated experiments on the same fingerprint region.After stability test,the recognition ability of three indicators was investigated for different fingerprints,verifying the uniqueness of pore-to-pore distance and pore-to-pore angle.Finally,a multiple recognition strategy was proposed that combined frequency distribution fitting curves for pore-to-pore distance and angle with other level 3 details,and was successfully applied to incomplete fingerprint recognition.This ink-enhanced optical and electrochemical extraction method and quantitative analysis provided a new path for fingerprint recognition.
8.Preparation and In Vitro Degradation Characteristics Analysis of Poly(lactic-co-glycolide)Microspheres Based on Microfluidic Process
Bao-Cheng WANG ; Cong-Yu MA ; Ke WANG ; Si-Tong ZHENG ; Xiao-Yan ZHANG ; Yue-Mei ZHAO ; Xun ZHAO ; Jian-Bin PAN ; Zheng-Song GAO ; Hai-Wei SHI ; Yao-Zuo YUAN ; Hong-Yuan CHEN
Chinese Journal of Analytical Chemistry 2025;53(4):621-630
Poly(lactic-co-glycolide)(PLGA)is a key excipient in long-acting sustained-release preparations,and its degradation properties directly affect the drug release behavior.In this study,PLGA microspheres were prepared by microfluidic techniques,and the morphology changes of the microspheres were observed by scanning electron microscopy(SEM).In alkaline environment,due to the accelerated hydrolysis of ester bonds,the surface of the microspheres was rapidly dissolved and eroded,and the degradation rate was significantly higher than that in acidic environment.High temperature accelerated the degradation of PLGA microspheres.Under neutral and alkaline conditions,the microspheres showed aggregation and adhesion.Under acidic conditions,the microspheres gradually decomposed into irregular fragments.The high ionic strength further promoted the surface corrosion of the microspheres,especially under extreme pH conditions.Simultaneously,PLGA microspheres encapsulating coumarin were prepared to simulate the microsphere formulation.The release rate of coumarin after degradation of the microspheres under different conditions was observed by measuring the absorbance with ultraviolet-visible spectrophotometry.The results were consistent with those of the blank microspheres.This study revealed that the degradation of PLGA microspheres was significantly pH-dependent,temperature sensitive and ion strength responsive.These findings not only helped to understand and optimize the long-term stability and controlled release performance of drug-carrying microspheres,but also provided a theoretical basis for further improvement of PLGA-based drug carrier design.
9.Synthesis of A New Naphthalenesulfonamide-based"Turn-on"Fluorescent Probe for Rapid Detection of Glyphosate
Rong-Rong ZHAO ; Hong-Lin LIU ; Ying-Ping HUANG ; Cui-Wen DENG ; Song-Yan LI ; Shui-Lian YU ; Mao-Sheng TAO ; Yi-Qun TIAN ; Xi YUAN
Chinese Journal of Analytical Chemistry 2025;53(6):903-913
Widespread utilization of glyphosate has led to environmental residues,posing potential threats to ecological systems and human health.Traditional methods for detection of glyphosate are limited by specialized equipment and operational techniques,resulting in inefficient responses.Therefore,it is urgent to develop a convenient,sensitive and accurate detection method for detection of glyphosate.Herein,a new naphthalenesulfonamide-based"Turn-on"fluorescent probe was synthesized using 2-chloroaniline and dansyl chloride as raw materials through a one-step process,which showed a good linear relationship between the glyphosate concentration in concentration range of 0.003-70 μmol/L and the fluorescence intensity(R2=0.995),with a detection limit of 2.73 nmol/L(S/N=3).Analytical techniques such as nuclear magnetic resonance(NMR)spectroscopy and high-resolution mass spectrometry(HRMS)were used to investigate the interaction mechanism between the fluorescent probe and glyphosate.The results indicated that a nucleophilic substitution reaction occurred between the probe and the secondary amine(—NH—)of glyphosate,inducing a photoinduced electron transfer(PET)effect which enhanced the fluorescence intensity by 11.2 times.The probe showed good anti-interference ability towards coexisting metal ions,anions and pesticides in water.When applied to determination of glyphosate in the samples such as tap water,river water(Xiangxi River Reservoir),soil,soybeans,and corn,the spiking recoveries ranged from 94.7%to 109.9%,demonstrating the high accuracy and broad applicability of this detection method.A portable test strip based on this fluorescent probe was developed for rapid semi-quantitative analysis of glyphosate.The developed method was rapid,sensitive,and portable,providing theoretical and technical support for on-site measurement of environmental contaminants.
10.Synthesis and Application of Benzimidazole-Carbazole-based Fluorescent Probe for Detection of Phosgene
Guang-Mei XU ; Ze-Yu SONG ; Qin-Qin TIAN ; Xiao-Hong ZHU ; Jin-Chao SHEN ; Wei HE
Chinese Journal of Analytical Chemistry 2025;53(10):1705-1713,中插37-中插41
Phosgene is a highly reactive chemical substance and a prevalent chemical warfare agent,and it is vitally important for rapid and accurate detection of phosgene to counteract terrorist threats and industrial accidents.In this work,a phosgene probe,designated as SX-Pho,which incorporated benzimidazole and hydroxyl groups as recognition motifs,was prepared through Suzuki coupling and Debus-Radziszewski methodologies to incorporate an electron-donating carbazole moiety.This probe exhibited a large Stokes shift(Approximately 130 nm).Upon exposure to triphosgene/triethylamine conditions(in situ phosgene generation),the fluorescence emission of probe at 470 nm underwent significant quenching,with a 20-fold reduction in intensity,while the fluorescence lifetime decreased from 3.30 ns to 3.06 ns.Concentration titration experiments demonstrated that SX-Pho achieved a lower detection limit of 57.8 nmol/L with high specificity and interference resistance.Preton nuclear magnetic resonance spectroscopy(1H NMR),high-resolution mass spectrometry,and density functional theory(DFT)calculations confirmed the cyclization reaction between hydroxyl groups,imines,and phosgene.The extent of overlap between the highest occupied molecular orbital(HOMO)and the lowest unoccupied molecular orbital(LUMO)was notably decreased,leading to the suppression of radiative transitions.The energy gap underwent a reduction of 0.43 eV,while the non-radiative transition was augmented,resulting in fluorescence quenching and achieving rapid detection of phosgene.Based on this,probe-loaded test strips were prepared.The color change under 365 nm illumination allowed visual discrimination of phosgene at concentrations below 20 μL/L.Furthermore,using a smartphone's built-in RGB application to measure the intensity of the blue(B)channel after the test strips were exposed to phosgene enabled both qualitative and quantitative detection.The detection range was 1.82-50 μL/L,with a limit of detection(LOD)of 1.814 μL/L.

Result Analysis
Print
Save
E-mail