1.Traditional Chinese medicine dry powder inhalers: research status and development ideas and methods.
Yu-Wen MA ; Yi-Chen ZENG ; Hao-Ran WANG ; Guang-Fu LIU ; Jun JIANG ; Yu-Song ZENG ; Bai-Xiu ZHAO ; Jin FANG
China Journal of Chinese Materia Medica 2025;50(3):620-631
As an innovative dosage form, traditional Chinese medicine(TCM) dry powder inhalers have emerged as a focal point in the research and development of new preparations due to its high efficiency, safety, and bioavailability. This paper systematically reviewed the relevant literature and patents associated with TCM dry powder inhalers to analyze the origins and the current research and development status. Furthermore, this paper probed into the research and development ideas of TCM dry powder inhalers regarding clinical positioning, prescription screening, and druggability. Additionally, the paper thoroughly analyzed the technical barriers in druggability studies and elaborated on corresponding research techniques and coping measures. Furthermore, it emphasized the need for improved regulations and policies governing TCM dry powder inhalers, advocated for strengthened oversight, and called for the establishment of a scientific quality evaluation system. Measures such as promoting production-education-research collaboration, enhancing personnel training, and fostering international exchanges were proposed to provide a scientific and systematic reference for the future research, development, and application of TCM dry powder inhalers, thereby facilitating the rapid modernization of TCM.
Humans
;
Dry Powder Inhalers/trends*
;
Drugs, Chinese Herbal/chemistry*
;
Medicine, Chinese Traditional/instrumentation*
;
Administration, Inhalation
2.Construction of a multigene expression system for plants and verification of its function.
Yin-Yin JIANG ; Ya-Nan TANG ; Yu-Ping TAN ; Shu-Fu SUN ; Juan GUO ; Guang-Hong CUI ; Jin-Fu TANG
China Journal of Chinese Materia Medica 2025;50(12):3291-3296
Constructing an efficient and easy-to-operate multigene expression system is currently a crucial part of plant genetic engineering. In this study, a fragment carrying three independent gene expression cassettes and the expression unit of the gene-silencing suppressor protein(RNA silencing suppressor 19 kDa protein, P19) simultaneously was designed and constructed. This fragment was cloned into the commonly used plant expression vector pCAMBIA300, and the plasmid pC1300-TP2-P19 was obtained. Each gene expression cassette consists of different promoters, fusion tags, and terminators. The target gene can be flexibly inserted into the corresponding site through enzymatic digestion and ligation or recombination and fused with different protein tags, which provides great convenience for subsequent detection. The enhanced green fluorescent protein(eGFP) reporter gene was individually constructed into each expression cassette to verify the feasibility of this vector system. The results of tobacco transient expression and laser-confocal microscopy showed that each expression cassette presented independent and normal expression. Meanwhile, the three key enzyme genes in the betanin synthesis pathway, BvCYP76AD, BvDODA1, and DbDOPA5GT, were constructed into the three expression cassettes. The results of tobacco transient expression phenotype, protein immunoblotting(Western blot), and chemical detection of product demonstrated that the three exogenous genes were highly expressed, and the target compound betanin was successfully produced. The above results indicated that the constructed multigene expression system for plants in this study was efficient and reliable and can achieve the co-transformation of multiple plant genes. It can provide a reliable vector platform for the analysis of plant natural product synthesis pathways, functional verification, and plant metabolic engineering.
Nicotiana/metabolism*
;
Genetic Vectors/metabolism*
;
Gene Expression Regulation, Plant
;
Plant Proteins/metabolism*
;
Plants, Genetically Modified/metabolism*
;
Genetic Engineering/methods*
;
Green Fluorescent Proteins/metabolism*
;
Gene Expression
3.Meta-analysis of the efficacy of plate fixation and external fixator fixation in the treatment of AO-C type distal radius fractures.
Guang-Yao LI ; Yong-Zhong CHENG ; Huan LIU ; Jun-Jie JIANG ; Yong-Yao LI ; Yang CHEN ; Yu-Xiang YAO
China Journal of Orthopaedics and Traumatology 2025;38(1):66-80
OBJECTIVE:
Meta-analysis of the clinical efficacy of plate and external fixator fixation in the treatment of AO-C type distal radius fractures.
METHODS:
PubMed, Embase, Cochrane Medical Library, Web of Science, CNKI, Wanfang, VIP and SinoMed databases were searched for all literature on randomized controlled clinical trials of AO-C distal radius fractures. The search time limits were from each database. The database will be established until June 30, 2023. The included studies were extracted according to the Cochrane Handbook (Version 6.3, 2022) for information extraction and literature quality evaluation. RevMan 5.4 was used to evaluate the risk of Publication bias, test heterogeneity and Perform Meta-analysis. The outcome indicators were:imaging anatomy indicators (volar inclination angle, ulnar deviation angle, radial height), wrist joint mobility (flexion, extension, rotation, ulnar deviation), complication rate, and comparison of surgical treatments (operative blood loss, operation time, hospitalization time, fracture healing time) and wrist joint function scores and related scales.
RESULTS:
(1) A total of 28 studies were included, with a total of 2 192 patients, including 1 096 cases in the plate internal fixation group and 1 096 cases in the external fixation group.(2) Meta analysis results showed:the surgical treatment situation of the external fixation group:surgical blood loss MD=-37.93, 95%CI(-48.54, -27.31), P<0.000 01;operation time MD=-31.58, 95%CI(-48.96, -14.20), P<0.000 4;hospitalization time MD=-4.58, 95%CI(-5.44, -3.71), P<0.000 01;the fracture healing time MD=-0.88, 95%CI(-1.35, -0.41), P<0.000 2, which were significantly better than that of the plate internal fixation group(P<0.05).(3) The two groups:palmar inclination angle MD=-0.17, 95%CI(-0.95, 0.61), P=0.68;ulnar declination MD=0.22, 95%CI(-0.73, 1.17), P=0.65, radial height MD=-0.24, 95%CI(-1.15, 0.67), P=0.60;flexion and extension MD=-5.63, 95%CI(-11.85, 0.58), P=0.08;rotation MD=-5.80, 95%CI(-12.77, 1.17), P=0.10, radioulnar deviation MD=-2.86, 95%CI(-10.87, 5.15), P=0.48;complication rate RR=0.96, 95%CI(0.63, 1.46), P=0.83;Gartland-Werley clinical wrist score MD=0.13, 95%CI(-0.80, 1.06), P=0.78;excellent and good rate of Gartland-Werley wrist clinical score RR=0.93, 95%CI(0.87, 1.01), P=0.08;excellent and good rate of Cooney wrist score RR=0.99, 95%CI(0.62, 1.59), P=0.98;wrist DASH score MD=-4.67, 95%CI(-14.96, 5.62), P=0.37;the differences were not significant (P>0.05).
CONCLUSION
Compared with internal fixation with plate, external fixation can significantly reduce the amount of surgical bleeding, shorten the operation time, hospitalization time and fracture healing time, and its imaging anatomical indicators, wrist mobility, and complications can be significantly reduced in treating AO-C distal radius fractures. Rates and wrist function scores were equivalent.
Humans
;
External Fixators
;
Bone Plates
;
Radius Fractures/surgery*
;
Fracture Fixation/methods*
;
Fracture Fixation, Internal
;
Wrist Fractures
4.Injectable agents for the induction of Peyronie's disease in model rats: a comparative study.
Guang-Jun DU ; Si-Yan XING ; Ning WU ; Tong WANG ; Yue-Hui JIANG ; Tao SONG ; Bai-Bing YANG ; Yu-Tian DAI
Asian Journal of Andrology 2025;27(1):96-100
Peyronie's disease (PD) is a disorder characterized by fibrous plaque formation in the penile tissue that leads to curvature and complications in advanced stages. In this study, we aimed to compare four injectable induction agents for the establishment of a robust rat model of PD: transforming growth factor-β1 (TGF-β1), fibrin, sodium tetradecyl sulfate (STS) combined with TGF-β1, and polidocanol (POL) combined with TGF-β1. The results showed that injection of TGF-β1 or fibrin into the tunica albuginea induced pathological endpoints without causing penile curvature. The STS + TGF-β1 combination resulted in both histological and morphological alterations, but with a high incidence of localized necrosis that led to animal death. The POL + TGF-β1 combination produced pathological changes and curvature comparable to STS + TGF-β1 and led to fewer complications. In conclusion, fibrin, STS + TGF-β1, and POL + TGF-β1 all induced PD with a certain degree of penile curvature and histological fibrosis in rats. The POL + TGF-β1 combination offered comparatively greater safety and clinical relevance and may have the greatest potential for PD research using model rats.
Animals
;
Male
;
Penile Induration/drug therapy*
;
Rats
;
Transforming Growth Factor beta1/metabolism*
;
Disease Models, Animal
;
Fibrin
;
Penis/drug effects*
;
Polidocanol/administration & dosage*
;
Rats, Sprague-Dawley
;
Polyethylene Glycols/administration & dosage*
;
Injections
5.Analysis of Gene Mutations Distribution and Enzyme Activity of G6PD Deficiency in Newborns in Guilin Region.
Dong-Mei YANG ; Guang-Li WANG ; Dong-Lang YU ; Dan ZENG ; Hai-Qing ZHENG ; Wen-Jun TANG ; Qiao FENG ; Kai LI ; Chun-Jiang ZHU
Journal of Experimental Hematology 2025;33(5):1405-1411
OBJECTIVE:
To analyze the distribution characteristics of glucose-6-phosphate-dehydrogenase (G6PD) mutations and their enzyme activity in newborns patients with G6PD deficiency in Guilin region.
METHODS:
From July 2022 to July 2024, umbilical cord blood samples from 4 554 newborns in Guilin were analyzed for G6PD mutations using fluorescence PCR melting curve analysis. Enzyme activity was detected in 4 467 cases using the rate assay.
RESULTS:
Among 4 467 newborns who underwent G6PD activity testing, 162 newborns (3.63%) were identified as G6PD-deficient, including 142 males (6.04%) and 20 females (0.94%), the prevalence of G6PD deficiency was significantly higher in males than in females (P < 0.001). Genetic analysis of 4 554 newborns detected G6PD mutations in 410 cases (9%), including 171 males (7.13%) and 239 females (11.09%), with a significantly higher mutation detection rate in females than in males (P < 0.001). A total of nine single mutations and four compound heterozygous mutations were identified. The most common mutations were c.1388G>A (33.66%), c.1376G>T (23.66%) and c.95A>G (16.34%). Among newborns who underwent both enzyme activity and genetic mutation testing, males with G6PD mutations had significantly lower enzyme activity than that of females with G6PD mutations(P < 0.001). Specifically, among newborns carrying the mutations c.1388G>A, c.1376G>T, c.95A>G, c.1024C>T or c.871G>A, males consistently exhibited lower enzymatic activity than females with the same mutations (P < 0.001). Furthermore, in male G6PD-deficient newborns, the enzyme activity levels in those carrying c.1388G>A, c.1376G>T, c.95A>G, c.1024C>T, or c.871G>A were lower than those in both the control group and the c.519C>T group (P < 0.05).
CONCLUSION
This study provides a comprehensive profile of G6PD deficiency incidence and mutation spectrum in the Guilin region. By analyzing enzyme activity and genetic mutation results, this study provides insights into potential intervention strategies and personalized management approaches for the prevention and treatment of neonatal G6PD deficiency in the region.
Humans
;
Infant, Newborn
;
Glucosephosphate Dehydrogenase Deficiency/epidemiology*
;
Glucosephosphate Dehydrogenase/genetics*
;
Female
;
Male
;
Mutation
;
China/epidemiology*
6.Efficacy and safety of a facilitated percutaneous coronary intervention with half-dose recombinant staphylokinase in ST-segment elevation myocardial infarction
Tian-yu WU ; Wen-hao ZHANG ; Peng-sheng CHEN ; Chen LI ; Tian WU ; Zhan LÜ ; Tong WANG ; Kun LIU ; Zhi-wen TAO ; Xiao-xuan GONG ; Liang YUAN ; Yong LI ; Bo CHEN ; Xin CHEN ; Zeng-guang CHEN ; Nai-quan YANG ; Yuan-yuan SANG ; Xiao-yan WANG ; Bai-hong LI ; Li ZHU ; Guo-yu WANG ; Xin ZHAO ; Chuan LU ; Jun JIANG ; Rui-na HAO ; Chun-jian LI
Chinese Journal of Interventional Cardiology 2025;33(8):431-438
Objective To investigate the clinical efficacy and safety of facilitated percutaneous coronary intervention(PCI)with half-dose recombinant staphylokinase(r-SAK)in patients with ST-segment elevation myocardial infarction(STEMI)who are expected to undergo PCI within 120 minutes.Methods From October 2021 to August 2022,a total of 200 STEMI patients in eight centers were included and randomly assigned in a 1﹕1 ratio to either r-SAK group or control group.Patients received loading doses of aspirin and ticagrelor and intravenous heparin and were randomized to receive an intravenous bolus of either 5 mg r-SAK or normal saline prior to PCI.The outcomes were set as ST-segment resolution(STR)at 60-90 minutes after PCI,the proportion and transition of pathological Q waves on the 5th day after PCI,and the proportion of high-sensitivity cardiac troponin T(hs-cTnT)peaking within 12 hours of onset.The safety outcome was major bleeding events defined as Bleeding Academic Research Consortium(BARC)≥type 3 bleeding during hospitalization.Results Compared with the control group,the r-SAK group had a higher proportion of STR≥70%within 60-90 minutes after PCI(58.3%vs.40.3%,P=0.009);a lower proportion of pathological Q waves(59.1%vs.74.1%,P=0.040);a lower rate of Q wave progression(14.8%vs.43.2%,P<0.001);a higher rate of Q wave disappearance(12.5%vs.3.7%,P=0.027);and a higher proportion of hs-cTnT peaking within 12 hours of symptom onset[31/40(77.5%)vs.17/33(51.5%),P=0.027].Regarding the safety outcome,no significant difference in BARC≥type 3 bleeding was found between the two groups during hospitalization(P>0.05).Conclusions For STEMI patients who were expected to undergo primary PCI within 120 minutes of symptom onset,the facilitated PCI with half-dose r-SAK significantly increased the proportion of STR≥70%at 60-90 minutes after PCI,reduced the formation of pathological Q waves,and shortened the time to peak hs-cTnT,without increasing the risk of bleeding,which should be an alternative reperfusion strategy worthy of further study.
7.Efficacy and safety of a facilitated percutaneous coronary intervention with half-dose recombinant staphylokinase in ST-segment elevation myocardial infarction
Tian-yu WU ; Wen-hao ZHANG ; Peng-sheng CHEN ; Chen LI ; Tian WU ; Zhan LÜ ; Tong WANG ; Kun LIU ; Zhi-wen TAO ; Xiao-xuan GONG ; Liang YUAN ; Yong LI ; Bo CHEN ; Xin CHEN ; Zeng-guang CHEN ; Nai-quan YANG ; Yuan-yuan SANG ; Xiao-yan WANG ; Bai-hong LI ; Li ZHU ; Guo-yu WANG ; Xin ZHAO ; Chuan LU ; Jun JIANG ; Rui-na HAO ; Chun-jian LI
Chinese Journal of Interventional Cardiology 2025;33(8):431-438
Objective To investigate the clinical efficacy and safety of facilitated percutaneous coronary intervention(PCI)with half-dose recombinant staphylokinase(r-SAK)in patients with ST-segment elevation myocardial infarction(STEMI)who are expected to undergo PCI within 120 minutes.Methods From October 2021 to August 2022,a total of 200 STEMI patients in eight centers were included and randomly assigned in a 1﹕1 ratio to either r-SAK group or control group.Patients received loading doses of aspirin and ticagrelor and intravenous heparin and were randomized to receive an intravenous bolus of either 5 mg r-SAK or normal saline prior to PCI.The outcomes were set as ST-segment resolution(STR)at 60-90 minutes after PCI,the proportion and transition of pathological Q waves on the 5th day after PCI,and the proportion of high-sensitivity cardiac troponin T(hs-cTnT)peaking within 12 hours of onset.The safety outcome was major bleeding events defined as Bleeding Academic Research Consortium(BARC)≥type 3 bleeding during hospitalization.Results Compared with the control group,the r-SAK group had a higher proportion of STR≥70%within 60-90 minutes after PCI(58.3%vs.40.3%,P=0.009);a lower proportion of pathological Q waves(59.1%vs.74.1%,P=0.040);a lower rate of Q wave progression(14.8%vs.43.2%,P<0.001);a higher rate of Q wave disappearance(12.5%vs.3.7%,P=0.027);and a higher proportion of hs-cTnT peaking within 12 hours of symptom onset[31/40(77.5%)vs.17/33(51.5%),P=0.027].Regarding the safety outcome,no significant difference in BARC≥type 3 bleeding was found between the two groups during hospitalization(P>0.05).Conclusions For STEMI patients who were expected to undergo primary PCI within 120 minutes of symptom onset,the facilitated PCI with half-dose r-SAK significantly increased the proportion of STR≥70%at 60-90 minutes after PCI,reduced the formation of pathological Q waves,and shortened the time to peak hs-cTnT,without increasing the risk of bleeding,which should be an alternative reperfusion strategy worthy of further study.
8.A single-center study on the safety and effectiveness of a novel non-implant interatrial shunt device
San-Shuai CHANG ; Xin-Min LIU ; Zheng-Ming JIANG ; Yu-Tong KE ; Qian ZHANG ; Qiang LÜ ; Xin DU ; Jian-Zeng DONG ; Guang-Yuan SONG
Chinese Journal of Interventional Cardiology 2024;32(8):425-433
Objective To preliminarily evaluate the safety and effectiveness of a novel non-implantable atrial shunt device based on radiofrequency ablation for the treatment of chronic heart failure(CHF).Methods This was a prospective single-arm study.From January 2023 to December 2023,five eligible CHF patients were consecutively enrolled at Beijing Anzhen Hospital,Capital Medical University,and underwent inter-atrial shunt using Shenzhen Betterway atrial shunt device.Pulmonary capillary wedge pressure(PCWP),right atrial pressure(RAP),pulmonary artery pressure(PAP),total pulmonary resistance(TPR),pulmonary vascular resistance(PVR),and pulmonary/systemic blood flow ratio(Qp/Qs)were measured using right heart catheterization before and immediately after procedure.Patients were followed up for 90 days,and echocardiography,right heart catheterization,and cardiac functional indicators were evaluated.The primary endpoint was procedural success.Secondary endpoints included clinical success,echocardiographic changes,6-minute walk distance(6MWD)changes,New York Heart Association(NYHA)class changes,Kansas city cardiomyopathy questionnaire(KCCQ)score changes,and amino-terminal probrain natriuretic peptide(NT-proBNP)level changes at 90 days.The safety endpoint was major cardiovascular and cerebrovascular adverse events and device-related adverse events.Results All five patients successfully achieved left-to-right atrial shunt.Compared with baseline,PCWP decreased significantly immediately after procedure in all five patients,with a procedural success rate of 100%.There were no significant changes in RAP,PAP,TPR,and PVR before and immediately after procedure.After 90 days follow-up,four patients had persistent left-to-right atrial shunt,and PCWP was significantly lower than baseline,with a clinical success rate of 80%.Compared with baseline,LVEF increased,left ventricular end-diastolic diameter decreased,and tricuspid annular plane systolic excursion and right ventricular fractional area change were not impaired in all five patients at 90 days.KCCQ scores and 6MWT improved,NT-proBNP decreased,and NYHA class did not change significantly.There were no deaths,rehospitalizations for heart failure,stroke-related adverse events,or device-related adverse events during the follow-up.Conclusions The novel non-implantable atrial shunt catheter can safely and effectively improve hemodynamic,echocardiographic,and cardiac functional indicators in patients with heart failure.However,larger-scale clinical studies are still needed to validate its long-term clinical effectiveness.
9.Effect of safflower yellow pigment injection combined with alprostadil on patients after coronary artery bypass grafting
Xin-Hua ZHANG ; Chun-Mei REN ; Li-Jie JIANG ; Wei-Guang YANG ; Hong-Ling SU ; Jing-Yu ZHAO
Chinese Journal of cardiovascular Rehabilitation Medicine 2024;33(5):590-593
Objective:To investigate the effect of safflower yellow pigment injection combined with alprostadil on patients after coronary artery bypass grafting(CABG).Methods:A total of 92 patients with coronary heart disease who received CABG in Department of Cardiovascular Surgery,Handan Central Hospital between September 2018 and September 2020 were selected.According to order of admission,they were divided into control group(n=46,from September 2018 to Sep-tember 2019,routine therapy+alprostadil after CABG)and study group(n=46,from October 2019 to September 2020,safflower yellow pigment injection based on control group),both groups were treated for 28d.On 3d after drug withdraw-al,therapeutic effect,cardiac function indexes,four myocardial enzyme spectrum and perioperative indexes were compared between two groups.Results:On 3d after drug withdrawal,compared with control group,patients in study group had sig-nificant higher total effective rate(73.9%vs.91.3%),left ventricular ejection fraction(LVEF)[(55.77±4.48)%vs.(62.18±4.21)%](P=0.028,<0.001),and significant lower left atrial diameter(LAD)[(36.83±3.45)mm vs.(32.09±3.23)mm],left ventricular end-diastolic diameter(LVEDd)[(49.04±4.65)mm vs.(43.83±5.24)mm],levels of creatine kinase(CK)[(125.13±14.21)U/L vs.(62.56±8.42)U/L],lactate dehydrogenase(LDH)[(203.58±31.63)U/L vs.(156.07±22.26)U/L],aspartate aminotransferase(AST)[(44.25±12.98)U/L vs.(35.41±12.37)U/L]and creatine kinase isoenzyme MB(CK-MB)[(28.11±9.84)U/L vs.(17.59±7.41)U/L](P<0.001 all).Conclusion:The combination of safflower yellow pigment injection and alprostadil can improve the thera-peutic effect and heart function,and reduce myocardial injury in patients after CABG.
10.Current status and prospects of exoskeletons applied in medical service support
Yao-Rui YU ; Xue-Jun HU ; Kun-Peng WU ; Jing-Guang PAN ; Huo-Liang CHEN ; Jie REN ; Wei JIANG
Chinese Medical Equipment Journal 2024;45(3):71-75
The current status of exoskeletons was introduced in enhancing individual soldier's battlefield rescue capabilities,promoting the integrated use of battlefield rescue equipment,protecting medical personnel on the battlefield and assisting injured soldiers in rehabilitation training.The challenges of exoskeletons faced in human-machine interaction,power supply endurance,heavy overall structure,restricted movement and high cost were analyzed when applied to medical service support,and some suggestions were proposed accordingly including enhancing technology research and development,integrated application,communication and cooperation and personnel training.References were provided for the application of exoskeletons in China's medical service support.[Chinese Medical Equipment Journal,2024,45(3):71-75]

Result Analysis
Print
Save
E-mail