1.Study on the movement patterns and influencing factors of lung tumors tracked by M6 cyberknife stereoscopic radiotherapy system
Niu ZEQIAN ; Song YONGCHUN ; Yuan ZHIYONG ; Wang JINGSHENG ; Dong YANG ; Yu XUYAO ; Chen HUAMING ; Tian XIAOLIN
Chinese Journal of Clinical Oncology 2025;52(2):71-74
Objective:To explore the movement patterns and factors influencing lung tumors tracked using the M6 cyberknife stereotactic radiotherapy(SRT)system and to provide a reference for the implementation of precise stereotactic radiotherapy for lung tumors.Method:A retrospective analysis was conducted on 29 patients with lung tumors who were treated using x-sight lung tracking technology and the M6 cyberknife SRT system at Tianjin Medical University Cancer Institute&Hospital,from January 2022 to August 2024.The tumor location and volume,irradiation dose,isodose line,and number of divisions were recorded.Lung tumor location and SPSS 26.0 software were used to analyze the movement amplitude of tumors in the left and right(LFT/RGT,LR)directions,the anterior-posterior(ANT/POS,AP)direction,and the superior-inferior(SUP/INF,SI)direction.The results are expressed as the mean±standard deviation((x)±s)mm,and a t-test was used for inter-group comparisons.Multiple linear regression was used to analyze the effects of factors such as age,gender,tumor location(upper and lower lungs),and tumor volume on the amplitudes of the lung tumor movements.Result:The average motion amplitudes in the LR direc-tions,AP direction,and SI direction of the tumor target areas were(3.5±1.8)mm,(5.3±1.7)mm,and(7.3±5.4)mm for the upper lung,based on 19 cases,and(3.1±1.6)mm,(4.5±2.2)mm,and(12.2±4.4)mm for the lower lung,based on 10 cases,respectively.There was a statistic-ally significant difference(P=0.015 3)in the amplitude of movements between the lower and upper lung tumors in the SI direction.The lung tumor movement amplitude in the SI direction was influenced by tumor location(P=0.035),and the movement amplitudes in the LR direc-tions and the AP direction were not related to factors such as gender,age,tumor location,and tumor volume.Conclusions:The lung tumor movement amplitudes for the different locations varied depending on the respiratory movement shown by the patient.In the SI direction,the movement amplitude of the lower lung tumors was greater than that of upper lung tumors,and this was due to tumor location effects.The movement amplitudes of the lower and upper lung tumors were similar in the LR directions and AP directions.Furthermore,movement amplitude was not affected by gender,age,tumor location,and tumor volume.
2.Establishment and performance evaluation of a droplet digital PCR method for detecting of Septin9 gene methylation in colorectal cancer
Jing ZHANG ; Xuyao JI ; Wenxu YANG ; Yu LIU
International Journal of Laboratory Medicine 2025;46(6):646-650
Objective To establish a droplet digital PCR(ddPCR)method for detecting the Septin9 gene methylation in colorectal cancer(CRC)and evaluate its performance.Methods Specific primers and probes were designed for the methylation of Septin9 gene.The reaction conditions of ddPCR for Septin9 gene methyl-ation detection were optimized,including primer and probe concentrations,annealing temperature and cycle number.A ddPCR method to detect the methylation of Septin9 gene was established.The linearity,sensitivi-ty,specificity,precision,accuracy and clinical diagnostic accuracy of the established method were evaluated by detecting methylation reference materials and clinical samples.Results The optimal concentrations of primers and probes were 500 nmol/L and 200 nmol/L,respectively.The optimal annealing temperature was 56℃and the optimal number of cycles was 45.The linearity test showed good linearity in the range of 5-104 copy/re-action,and the preset detection limit of Septin9 gene methylation concentration detected by ddPCR was 0.422%,which could specifically identify Septin9 gene methylation positive control.In precision evaluation,the coefficients of variation of high concentration and low concentration reference materials were 1.340 0%and 3.330 0%,which met the relevant requirements.The results of accuracy test showed that the positive co-incidence rate and negative coincidence rate of 10 repeated tests of methylation quality control samples of 3 batches were both 100%.The results of clinical samples showed that the sensitivity and specificity of ddPCR detection of Septin9 gene methylation in CRC group were 82.61%(95%CI 66.10%—99.10%)and 78.38%(95%CI 65.20%—91.60%),respectively.The area under the curve was 0.881 3(95%CI 0.784-0.978 6).Conclusion The ddPCR method for detection of Septin9 gene methylation in CRC has high sensitivity,speci-ficity,precision,accuracy and clinical diagnostic accuracy.It can provide a reliable technical means for early di-agnosis,monitoring and treatment of CRC.
3.Application of ArcherQA for independent dose verification of SRT plans for CyberKnife
Xuyao YU ; Yuwen WANG ; Yang DONG ; Daguang ZHANG ; Yongchun SONG ; Qiang REN ; Xi PEI ; Zhiyong YUAN ; Wei WANG ; Jianrong DAI
Chinese Journal of Radiation Oncology 2025;34(11):1139-1145
Objective:To evaluate the feasibility of using the domestic ArcherQA system for fast and simplified independent verification of CyberKnife (CK) stereotactic radiotherapy (SRT) plans.Methods:SRT plans of 57 patients treated with CK at Tianjin Medical University Cancer Institute and Hospital from August 2021 to August 2022 were retrospectively analyzed, including 15 intracranial, 30 pulmonary, and 12 abdominal tumors cases. Point-dose and planar-dose verifications were performed using an ionization chamber and radiochromic films embedded in a homogeneous phantom, and the results were compared with those calculated by the treatment planning system (TPS). The localization CT images and corresponding SRT plans were imported into the ArcherQA system for independent dose verification and analysis. The correlation between ArcherQA results and phantom measurements was analyzed, with comparisons of target mean dose differences and γ pass rates.Results:Phantom measurement results showed, the measured point-dose differences for intracranial, lung, and abdominal plans were -0.94% ± 3.22%, 1.92% ± 2.05%, and 2.12% ± 0.77%, respectively. The mean dose differences in target dose calculation between ArcherQA and TPS: intracranial in the gross tumor volume (GTV) regions were 0.34% ± 2.21%, lung tumor GTV were -2.47% ± 2.46%, and abdominal tumor GTV were 0.80% ± 2.61%, respectively. Among them, the abdominal GTV region showed the highest correlation between ArcherQA and measured results ( r=0.78). The average two-dimensional γ pass rates (2 mm/2%, threshold=10%) measured using phantom films were 95.92% ± 2.35% for intracranial, 95.70% ± 2.74% for lung, and 96.74% ± 3.41% for abdominal tumors plans, respectively. The three-dimensional ArcherQA results showed comparable γ pass rates (1 mm/2%, threshold=10%) for lung and abdominal GTV and PTV regions, with similar medians and data dispersion to film measurements. Conclusions:The ArcherQA system enables rapid and efficient independent dose verification of CK SRT plans without the need for additional hardware. The verification results show good correlation with phantom measurements, supporting its potential as an auxiliary quality assurance tool in clinical CK SRT implementation.
4.Study on the movement patterns and influencing factors of lung tumors tracked by M6 cyberknife stereoscopic radiotherapy system
Niu ZEQIAN ; Song YONGCHUN ; Yuan ZHIYONG ; Wang JINGSHENG ; Dong YANG ; Yu XUYAO ; Chen HUAMING ; Tian XIAOLIN
Chinese Journal of Clinical Oncology 2025;52(2):71-74
Objective:To explore the movement patterns and factors influencing lung tumors tracked using the M6 cyberknife stereotactic radiotherapy(SRT)system and to provide a reference for the implementation of precise stereotactic radiotherapy for lung tumors.Method:A retrospective analysis was conducted on 29 patients with lung tumors who were treated using x-sight lung tracking technology and the M6 cyberknife SRT system at Tianjin Medical University Cancer Institute&Hospital,from January 2022 to August 2024.The tumor location and volume,irradiation dose,isodose line,and number of divisions were recorded.Lung tumor location and SPSS 26.0 software were used to analyze the movement amplitude of tumors in the left and right(LFT/RGT,LR)directions,the anterior-posterior(ANT/POS,AP)direction,and the superior-inferior(SUP/INF,SI)direction.The results are expressed as the mean±standard deviation((x)±s)mm,and a t-test was used for inter-group comparisons.Multiple linear regression was used to analyze the effects of factors such as age,gender,tumor location(upper and lower lungs),and tumor volume on the amplitudes of the lung tumor movements.Result:The average motion amplitudes in the LR direc-tions,AP direction,and SI direction of the tumor target areas were(3.5±1.8)mm,(5.3±1.7)mm,and(7.3±5.4)mm for the upper lung,based on 19 cases,and(3.1±1.6)mm,(4.5±2.2)mm,and(12.2±4.4)mm for the lower lung,based on 10 cases,respectively.There was a statistic-ally significant difference(P=0.015 3)in the amplitude of movements between the lower and upper lung tumors in the SI direction.The lung tumor movement amplitude in the SI direction was influenced by tumor location(P=0.035),and the movement amplitudes in the LR direc-tions and the AP direction were not related to factors such as gender,age,tumor location,and tumor volume.Conclusions:The lung tumor movement amplitudes for the different locations varied depending on the respiratory movement shown by the patient.In the SI direction,the movement amplitude of the lower lung tumors was greater than that of upper lung tumors,and this was due to tumor location effects.The movement amplitudes of the lower and upper lung tumors were similar in the LR directions and AP directions.Furthermore,movement amplitude was not affected by gender,age,tumor location,and tumor volume.
5.Application of ArcherQA for independent dose verification of SRT plans for CyberKnife
Xuyao YU ; Yuwen WANG ; Yang DONG ; Daguang ZHANG ; Yongchun SONG ; Qiang REN ; Xi PEI ; Zhiyong YUAN ; Wei WANG ; Jianrong DAI
Chinese Journal of Radiation Oncology 2025;34(11):1139-1145
Objective:To evaluate the feasibility of using the domestic ArcherQA system for fast and simplified independent verification of CyberKnife (CK) stereotactic radiotherapy (SRT) plans.Methods:SRT plans of 57 patients treated with CK at Tianjin Medical University Cancer Institute and Hospital from August 2021 to August 2022 were retrospectively analyzed, including 15 intracranial, 30 pulmonary, and 12 abdominal tumors cases. Point-dose and planar-dose verifications were performed using an ionization chamber and radiochromic films embedded in a homogeneous phantom, and the results were compared with those calculated by the treatment planning system (TPS). The localization CT images and corresponding SRT plans were imported into the ArcherQA system for independent dose verification and analysis. The correlation between ArcherQA results and phantom measurements was analyzed, with comparisons of target mean dose differences and γ pass rates.Results:Phantom measurement results showed, the measured point-dose differences for intracranial, lung, and abdominal plans were -0.94% ± 3.22%, 1.92% ± 2.05%, and 2.12% ± 0.77%, respectively. The mean dose differences in target dose calculation between ArcherQA and TPS: intracranial in the gross tumor volume (GTV) regions were 0.34% ± 2.21%, lung tumor GTV were -2.47% ± 2.46%, and abdominal tumor GTV were 0.80% ± 2.61%, respectively. Among them, the abdominal GTV region showed the highest correlation between ArcherQA and measured results ( r=0.78). The average two-dimensional γ pass rates (2 mm/2%, threshold=10%) measured using phantom films were 95.92% ± 2.35% for intracranial, 95.70% ± 2.74% for lung, and 96.74% ± 3.41% for abdominal tumors plans, respectively. The three-dimensional ArcherQA results showed comparable γ pass rates (1 mm/2%, threshold=10%) for lung and abdominal GTV and PTV regions, with similar medians and data dispersion to film measurements. Conclusions:The ArcherQA system enables rapid and efficient independent dose verification of CK SRT plans without the need for additional hardware. The verification results show good correlation with phantom measurements, supporting its potential as an auxiliary quality assurance tool in clinical CK SRT implementation.
6.Quality evaluation on diagnostic accuracy research in China from 2017 to 2022 based on STARD2015
Jing ZHANG ; Wenxu YANG ; Youmei LU ; Xuyao JI ; Yu LIU
Chinese Journal of Laboratory Medicine 2024;47(3):308-313
Objective:The quality of domestic diagnostic accuracy research was evaluated to explore the quality level of domestic diagnostic accuracy research based on Standards for Reporting of Diagnostic Accuracy 2015 (STARD2015).Methods:The Chinese core journals of CNKI and Wanfang Database were searched, and research literature on diagnostic accuracy published from 2017 to 2022 were collected. The main search terms are diagnostic test, sensitivity, specificity, receiver operating characteristic (ROC) curve, etc. The literature was selected according to the inclusion criteria, and the quality of the included literature was evaluated independently by two reviewers, and the conformity rate of the STARD2015 report and the STARD2015 article was calculated. The report quality of the literature was divided into three levels (low, medium and high) according to the conformity rate of the STARD2015 report. The proportion of literature at each level and the proportion of literature at medium and high level in each year were counted. According to quality analysis on the contents of the included articles, articles were divided into standardized reports and unstandardized reports. Intragroup correlation coefficient ( ICC) was used to analyze the consistency of two reviewers. The trend Chi-square test was used to analyze the trend of the proportion of medium and high level literature in each year. One-way analysis of variance was used to compare the coincidence rates evaluated by STARD2015 for each year. Results:A total of 6 771 studies on diagnostic accuracy published from 2017 to 2022 were included. The compliance rate sccording to STARD2015 was 39.56%±4.90%, and the reported compliance rate ranged from 17.65% to 64.71% (the number of reported items ranged from 6 to 22), and 93.53% (6 333/6 771) literatures were in the middle level. Compliance rate of STARD2015 reports varied significantly among different years ( F=25.023, P<0.01), and the compliance rate of 2021 was significantly higher than that of other years ( P<0.01). The proportion of medium and high level literatures according to STARD2015 showed an increasing trend ( χ 2=14.099, P<0.01). The reporting situation of each item varied significantly, and the conformity rate of items raned from 0 to 100%. According to report item, non-standard report rate was 10.34% (569/5 503) for item 6, 4.15% (277/6 677) for item 8, 21.84% (1 447/6 626) for item 20, 66.67% (24/36) for item 22, and 26.03% (877/3 369) for item 26. Conclusions:The overall report quality of published domestic literature on diagnostic accuracy from 2017 to 2022 is at a medium level according to STARD2015, and the reports conformity rate of each item vary significantly, indicating significant knowledge gap on STARD2015 among domestic researchers. The promotion of STARD2015 needs to be strengthened.
7.Verification Phantom-based clinical quality control and detection of the MLC of CyberKnife M6
Xuyao YU ; Yang DONG ; Yuwen WANG ; Zhiyong YUAN ; Xiaolin TIAN ; Zeqian NIU ; Huaming CHEN ; Jingsheng WANG ; Yongchun SONG
Chinese Journal of Radiological Medicine and Protection 2022;42(7):511-515
Objective:To provide a new morning check method for the output dose stability of the multileaf collimator (MLC) of the CyberKnife M6 (CK-M6) system.Methods:The CT images of a verification phantom with a size of 20 cm × 20 cm × 10 cm were transmitted into the Precision Treatment Plan ning System (ver. 1.1.1.1). The high-precision alignment between the accelerator output front and the fixed position of the phantom surface was achieved using the fiducial tracking method. A 10 cm × 10 cm radiation field was formed by the MLC and a DailyCheck plan with an output of 200 MU was designed. The repeatability, sensitivity, and accuracy of the DailyCheck plan were measured, and the CK-M6 system was continuously tested for one month using the artificial fixed method and the DailyCheck plan designed in this study. Results:The average and the standard deviation of 10 repeated measurements by the DailyCheck plan were 492.28 pC and 0.09, respectively, indicating good stability. There was a linear correlation between the measured values and the output dose, with a correlation coefficient of R2 > 0.999. Moreover, there was a position deviation of 2 mm between the phantom and the accelerator output front, and the result ant effect on the measured values was equivalent to a dose deviation caused by an output of 1.24 MU. The result from the continuous measurement of both the artificial fixed method and the DailyCheck plan fell within permissible limits, showing high consistency. Conclusions:The DailyCheck plan established through the fiducial tracking of a verification phantom can achieve the convenient, quick, and accurate daily detection of the output dose stability of the MLC of CK-M6. Therefore, this method can be widely applied in the clinical quality control of the CK-M6 system.
8.Association between nonalcoholic fatty liver disease and depression
Xuyao YANG ; Di YU ; Jinhan ZHAO
Journal of Clinical Hepatology 2020;36(1):201-204
At present, nonalcoholic fatty liver disease (NAFLD) has become one of the most common chronic liver diseases in the world. With the development of the bio-psycho-social medical model, the mental health problems of patients with NAFLD are gradually attracting more and more attention. In recent years, more and more studies have been conducted on the association between NAFLD and psychiatric diseases, especially depression. Studies have shown that there is a significant correlation between NAFLD and depression; however, the common pathophysiological mechanism of such correlation is still unclear and further studies are needed to determine their causal relationship and treatment. This article reviews the research advances in the association between NAFLD and depression, common pathophysiological mechanism, and treatment, so as to lay a foundation for further research on these two disease and help with their prevention and treatment in future clinical practice.
9.Association between anxiety and nonalcoholic fatty liver disease
Di YU ; Xuyao YANG ; Jinhan ZHAO ; Lixue CHUAN ; Jiang CHANG
Journal of Clinical Hepatology 2020;36(11):2589-2592
With the rapid change in lifestyle in recent years, the prevalence rate of nonalcoholic fatty liver disease (NAFLD) is increasing year by year and it has gradually become one of the major causes of chronic liver diseases. With the development of the bio-psycho-social medical model, the influence of psychological diseases on physical diseases has attracted the attention of scholars. At present, evidence has shown that anxiety, as one of the most common type of mental disorders, may be associated with the development of NAFLD. This article introduces the current status of research on anxiety and NAFLD and their common influencing factors and predicts the possible pathophysiological mechanism of NAFLD caused by anxiety, so as to lay a foundation for further research on the association between anxiety and NAFLD and provide new directions for the treatment of NAFLD.
10. Dosimetric comparison of two radiotherapy treatment planning approaches for multiple brain metastases from non-small cell lung cancer on CyberKnife
Xuyao YU ; Zhiyong YUAN ; Fengtong LI ; Yang DONG ; Yongchun SONG ; Xiaoguang WANG ; Ping WANG
Chinese Journal of Radiological Medicine and Protection 2019;39(12):926-930
Objective:
To compare the dosimetrics of the plan target volume (PTV) and organs at risk (OARs) between two treatment planning approaches for patients with multiple brain metastases from non-small cell lung cancer on CyberKnife.
Methods:
20 patients with multiple metastases from lung carcinoma were reviewed and analyzed, who had been treated by CyberKnife from December 2017 to December 2018. The CyberKnife stereotactic radiotherapy plans of the 20 cases were re-planed with single plan for multiple lesions and multiple plans per lesion. The dosimetry differences of PTV and OARs isodose disribution, conformity index (CI), total beam counts and total monitor units (MUs) were compared in the two types of plans.
Results:
The two types of plans could satisfy over 95% PTV coverage of the prescription dose. The maximum and mean dose of normal brain adjacent to the PTV were reduced in multiple plan approach effectively. Moreover, the maximum and mean dose of OARs (brainstem) dropped by 1.62% and 5.57% (

Result Analysis