1.Spatiotemporal Remodeling of Enteric Neural Pathways Underlies ColonicDysmotility Following Spinal Cord Injury in Rats
Min Seob KIM ; Sei KIM ; Se Eun HA ; Hyun Seok CHOI ; Myeong Hwan YU ; Jisong YOU ; Dahyun SEON ; Do Hee LEE ; Min Cheol JOO ; Yong Sung KIM ; Suck Chei CHOI ; Joong Goo KWON ; Kyung Sik PARK ; Hyun Jin KIM ; Seungil RO ; Moon Young LEE
Journal of Neurogastroenterology and Motility 2026;32(1):86-98
Background/Aims:
Spinal cord injury (SCI) frequently impairs defecation, severely affecting the quality of life. This study examines compensatory neural remodeling after SCI, focusing on basal colonic contractility, neural responses to electrical field stimulation, and alterations in excitatory cholinergic and inhibitory nitrergic pathways.
Methods:
Female Sprague–Dawley rats underwent either sham surgery or T10 spinal cord transection and were categorized into 3 groups: sham, 1-week post-SCI (acute), and 4-week post-SCI (chronic). Colonic contractility was assessed in an organ bath using electrical field stimulation in the presence of a nitric oxide synthase inhibitor. Neural protein expression was analyzed by immunofluorescence and Western blotting.
Results:
SCI produced region- and time-dependent impairments in colonic contractility, with distinct alterations in the proximal circular and longitudinal muscles across acute and chronic phases. Neural excitability shifted dynamically, showing enhanced excitatory activity in the proximal longitudinal muscle at 1-week and the distal circular muscle at 4-week post-SCI. Protein analysis revealed increased neuronal nitric oxide synthase in the proximal colon, decreasedsoluble guanylyl cyclase in the distal colon, upregulated muscarinic M3 receptor in the proximal colon, and reduced vaso-active intestinal peptide receptor 1 in both proximal and distal regions.
Conclusion
SCI induces spatiotemporal remodeling of excitatory and inhibitory neural pathways, contributing to colonic dysmotility and revealing potential targets for therapeutic intervention.
2.Effects of MAO-B and COMT Inhibitors on Sleep Disturbances in Patients With Parkinson’s Disease: A Network Meta-Analysis
Seon-Min LEE ; Sung Ryul SHIM ; Kyum-Yil KWON ; Taeho Greg RHEE ; Yu Jin JUNG
Journal of Movement Disorders 2026;19(1):67-75
Objective:
Sleep disturbances are common and debilitating nonmotor symptoms (NMS) in Parkinson’s disease (PD) patients and profoundly affect quality of life. Despite emerging evidence suggesting that monoamine oxidase B (MAO-B) and catechol-O-methyltransferase (COMT) inhibitors may alleviate NMS, their specific effects on sleep remain unclear. The aim of this network meta-analysis (NMA) was to compare the efficacy of these inhibitors related to sleep problems in PD patients.
Methods:
Following a systematic search of PubMed, Cochrane, and Embase, studies comparing MAO-B or COMT inhibitors and assessing sleep outcomes in PD patients were identified. An NMA was conducted using data from the seven studies that met our inclusion criteria. The outcomes included subjective sleep quality, daytime sleepiness, and objective polysomnography (PSG) parameters.
Results:
No statistically significant differences were found between the effects of the MAO-B and COMT inhibitors on improving subjective sleep quality or daytime sleepiness. However, analyses of objective PSG data revealed that, compared with rasagiline and placebo, safinamide significantly increased rapid eye movement sleep duration (mean difference, 5.70 min [95% CI, 2.26 to 9.14]) and decreased wake time after sleep onset (mean difference, -10.20 min [-19.38 to -1.02]).
Conclusion
These findings suggest that safinamide may offer additional value for managing sleep disruptions beyond its known motor benefits in patients with PD. Given the limited number and small scale of available trials, the overall evidence should be interpreted cautiously. Nonetheless, this analysis highlights the need for future high-quality trials focused on sleep outcomes to guide the personalized use of MAO-B and COMT inhibitors for sleep disturbances in PD patients.
3.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
4.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
5.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
6.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
7.The impact of body mass index on mortality according to age in hemodialysis patients: an analysis of the Korean Renal Data System
Hyunglae KIM ; Seon A JEONG ; Yoonjung CHO ; Kyeong Min KIM ; Sun Deuk HWANG ; Sun Ryoung CHOI ; Hajeong LEE ; Ji Hyun KIM ; Su Hyun KIM ; Tae Hee KIM ; Ho-Seok KOO ; Chang-Yun YOON ; Kiwon KIM ; Seon Ho AHN ; Hye Eun YOON ; Tae Hyun BAN ; Yu Ah HONG ; Yong Kyun KIM
Kidney Research and Clinical Practice 2025;44(2):217-227
The impact of age on the relationship between body mass index (BMI) and all-cause mortality in hemodialysis (HD) patients is not clearly understood. Using data from the Korean Renal Data System (2001–2022), we analyzed 66,129 HD patients, stratified into young (<65 years, n = 24,589), younger-old (65–74 years, n = 17,732), and older-old (≥75 years, n = 23,808) groups. Patients were categorized into BMI quartiles, and survival outcomes were evaluated using Kaplan-Meier curves and event time ratios for the relative change in the survival time. During the follow-up period, 14,360 of the patients (21.7%) died, with a median follow-up of 3.4 years. Kaplan-Meier curves revealed poorer outcomes in lower BMI quartiles across all age groups. The lowest BMI quartile was significantly associated with a shorter survival time compared to the highest BMI quartile, with a 15% reduction in the young group (p = 0.001) and a 12% reduction in the older-old group (p = 0.002). Predicted survival time increases with rising BMI in the young group, but the rate of increase slows in the younger-old group and plateaus in the older-old group after a BMI of 25 kg/m2. Lower BMI correlates with higher mortality, particularly in younger HD patients.
8.Maternal exposure to airborne particulate matter during pregnancy and lactation induces kidney injury in rat dams and their male offspring: the role of vitamin D in pregnancy and beyond
Min Hwa SON ; Eujin PARK ; Hyung Eun YIM ; Yoon Jeong NAM ; Yu-Seon LEE ; Eui Kyung CHOI ; Sang Hoon JEONG ; Ju‑Han LEE
Kidney Research and Clinical Practice 2024;43(5):648-662
Little is known about the transgenerational effects of maternal exposure to fine particulate matter (PM2.5) on offspring kidney health. This study investigated the effect of maternal administration of PM2.5 or PM2.5 with vitamin D during pregnancy and lactation on renal injury in rat dams and their offspring. Methods: Nine pregnant Sprague-Dawley rats received oral administration of normal saline, airborne PM2.5, or PM2.5 with vitamin D from gestational day 11 to postpartum day 21. Kidneys of rat dams (n = 3 for each group) and their male offspring (n = 5 for each group) were taken for analysis on postpartum or postnatal day 21. Results: Maternal PM2.5 exposure increased glomerular damage, tubulointerstitial injury, and cortical macrophage infiltration in both dams and pups; all increases were attenuated by vitamin D administration. In dam kidneys, PM2.5 increased the protein expression of vitamin D receptor (VDR), klotho, and tumor necrosis factor-α; vitamin D lessened these changes. The expressions of renin, nuclear factor erythroid 2-related factor 2 (Nrf2), and nuclear factor-kappa B (NF-κB) p50 decreased in rat dams exposed to PM2.5. In offspring kidneys, exposure to maternal PM2.5 reduced the expression of VDR, renin, angiotensin-converting enzyme (ACE), Nrf2, and NF-κB p50, but increased cytochrome P450 24A1 expression. Maternal vitamin D administration with PM2.5 enhanced VDR, ACE, and NF-κB p50 activities in pup kidneys. Conclusion: PM2.5 exposure during nephrogenesis may exert transgenerational renal impairment, and maternal vitamin D intake could attenuate PM2.5-induced kidney damage in mothers and their offspring.
9.Maternal exposure to airborne particulate matter during pregnancy and lactation induces kidney injury in rat dams and their male offspring: the role of vitamin D in pregnancy and beyond
Min Hwa SON ; Eujin PARK ; Hyung Eun YIM ; Yoon Jeong NAM ; Yu-Seon LEE ; Eui Kyung CHOI ; Sang Hoon JEONG ; Ju‑Han LEE
Kidney Research and Clinical Practice 2024;43(5):648-662
Little is known about the transgenerational effects of maternal exposure to fine particulate matter (PM2.5) on offspring kidney health. This study investigated the effect of maternal administration of PM2.5 or PM2.5 with vitamin D during pregnancy and lactation on renal injury in rat dams and their offspring. Methods: Nine pregnant Sprague-Dawley rats received oral administration of normal saline, airborne PM2.5, or PM2.5 with vitamin D from gestational day 11 to postpartum day 21. Kidneys of rat dams (n = 3 for each group) and their male offspring (n = 5 for each group) were taken for analysis on postpartum or postnatal day 21. Results: Maternal PM2.5 exposure increased glomerular damage, tubulointerstitial injury, and cortical macrophage infiltration in both dams and pups; all increases were attenuated by vitamin D administration. In dam kidneys, PM2.5 increased the protein expression of vitamin D receptor (VDR), klotho, and tumor necrosis factor-α; vitamin D lessened these changes. The expressions of renin, nuclear factor erythroid 2-related factor 2 (Nrf2), and nuclear factor-kappa B (NF-κB) p50 decreased in rat dams exposed to PM2.5. In offspring kidneys, exposure to maternal PM2.5 reduced the expression of VDR, renin, angiotensin-converting enzyme (ACE), Nrf2, and NF-κB p50, but increased cytochrome P450 24A1 expression. Maternal vitamin D administration with PM2.5 enhanced VDR, ACE, and NF-κB p50 activities in pup kidneys. Conclusion: PM2.5 exposure during nephrogenesis may exert transgenerational renal impairment, and maternal vitamin D intake could attenuate PM2.5-induced kidney damage in mothers and their offspring.
10.Comparison of GastroPanel® and GENEDIA® in Diagnosing Helicobacter pylori Infection and Gastric Lesions
Yonghoon CHOI ; Nayoung KIM ; Seon Hee LIM ; Ji Hyun PARK ; Jeong Hwan LEE ; Yeejin KIM ; Hyemin JO ; Ho-Kyoung LEE ; Jinju CHOI ; Yu Kyung JUN ; Hyuk YOON ; Cheol Min SHIN ; Young Soo PARK ; Dong Ho LEE
Journal of Cancer Prevention 2024;29(4):148-156
Serological tests for Helicobacter pylori needs local validation as the diagnostic accuracy may vary depending on the prevalence of H.pylori. This study examined the diagnostic performance of two ELISA, GastroPanel® (GastroPanel ELISA; Biohit Oyj) and GENE-DIA® (GENEDIA® H. pylori ELISA, Green Cross Co.) in Korean population. One thousand seventy seven patients who visited for esophagogastroduodenoscopy between 2013 and 2023 were prospectively enrolled, and serum samples from the subjects were tested using both GastroPanel® and GENEDIA® . The two tests were compared for their diagnostic accuracy in detecting atrophic gastritis (AG), intestinal metaplasia (IM), gastric adenoma (GA), and gastric cancer (GC), and the positivity rates by age and sexwere observed. There was substantial correlation (Pearson coefficient [r] = 0.512, P < 0.001) and agreement (Cohen’s Kappa coefficient [κ] = 0.723, P < 0.001) between the results obtained using GastroPanel® and GENEDIA® . The test results from the two kits did not match perfectly with a discrepancy observed in approximately 16% of cases, that 67 subjects were positive only on GENE-DIA® while 75 subjects were positive only on GastroPanel® . The area under receiver operating characteristic curve for AG, IM, GA,and GC using GastroPanel® were 0.666, 0.635, 0.540, and 0.575, while the results tested using GENEDIA® were 0.649, 0.604, 0.553, and 0.555, respectively, without significant difference between the two results. GastroPanel® and GENEDIA® showed similar performance in terms of diagnostic accuracy; but the test results did not match perfectly. A large-scale validation study in Koreansis needed.

Result Analysis
Print
Save
E-mail