1.Quantitative Analysis of Drusen in South Korean Patients: A 36-Month Follow-Up Study
Tae Rim KIM ; Tae Gi KIM ; Jaehwan CHOI ; Seung-Young YU ; Kiyoung KIM
Korean Journal of Ophthalmology 2026;40(1):87-98
Purpose:
This study aimed to quantitatively evaluate longitudinal changes in drusen area and volume over 36 months in South Korean patients and to identify the factors associated with these changes and the development of advanced age-related macular degeneration (AMD).
Methods:
In this retrospective study, 38 eyes from 38 patients diagnosed with drusen were analyzed. The drusen area and volume were measured using spectral-domain optical coherence tomography (SD-OCT; Cirrus 5000, Carl Zeiss Meditec) with an automated retinal pigment epithelium elevation map algorithm. To minimize bias from variable follow-up intervals, an annualized classification framework was adopted. Based on percentage change in drusen area within the 5-mm circle, eyes were categorized as progressed (increase >20%), stable (change within ±20%), or regressing (decrease >20%).
Results:
Both drusen area and volume increased significantly up to 24 months (area, p = 0.003; volume, p = 0.028) and then showed a modest decline at 36 months, remaining above baseline levels. No significant difference in the proportions of progressed, stable, or regressing eyes was observed across 12-month intervals or compared with baseline (all p > 0.05). A larger baseline 5-mm drusen area was significantly associated with the development of advanced AMD (adjusted odds ratio, 2.818; 95% confidence interval, 1.022–7.767; p = 0.045). Eyes that exhibited at least one episode of drusen regression showed a higher incidence of advanced AMD (36.8% vs. 5.3%, p = 0.042).
Conclusions
Drusen in South Korean patients demonstrated dynamic morphological remodeling over time. Drusen regression was not a benign phenomenon but rather a potential high-risk marker for progression to advanced AMD. These findings highlight the importance of population-specific, quantitative SD-OCT monitoring for early risk stratification in East Asian eyes.
2.Psychometric Properties of the Mixed State Severity Index for Patients With Mood Disorder
Woojae MYUNG ; Hyeona YU ; Hyo Shin KANG ; Daseul LEE ; Junwoo JANG ; Jakyung LEE ; Joohyun YOON ; Yun Seong PARK ; Hyun A RYOO ; Ye Rim KIM ; Kwang Ho PARK ; Chan Woo LEE ; Yoonjeong JANG ; Kimyoung KIM ; Nara LEE ; Sanghoon HONG ; Hong-Hee WON ; Tae Hyon HA ; Jungkyu PARK
Psychiatry Investigation 2026;23(1):106-117
Objective:
This study aimed to develop a reliable and valid Mixed State Severity Index (MSSI) to assess mood instability in patients with mood disorders and determine cutoff scores.
Methods:
Twenty-one items were selected based on Koukopoulos’ criteria for mixed depressive episode, historically referred to as agitated depression, and Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition, Text Revision mixed features criteria. The MSSI was administered to 242 patients (major depressive disorder [n=92], bipolar disorder [BD] I [n=78], and BD II [n=72]) and 726 controls.
Results:
The MSSI demonstrated high internal consistency (α=0.78–0.90). Exploratory factor analysis revealed a stable four-factor structure. Based on receiver operating characteristic analysis, optimal cutoff scores were identified to distinguish mood disorder groups from controls, ranging from 19.5 to 27.5 depending on diagnosis.
Conclusion
The MSSI is a reliable and valid instrument for assessing the severity of mixed features in patients with mood disorders. The established cutoff scores enhance its clinical utility, providing robust diagnosis and treatment planning support.
3.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
4.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
5.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
6.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
7.KASL clinical practice guidelines for noninvasive tests to assess liver fibrosis in chronic liver disease
Mi Na KIM ; Ji Won HAN ; Jihyun AN ; Beom Kyung KIM ; Young-Joo JIN ; Seung-seob KIM ; Minjong LEE ; Han Ah LEE ; Yuri CHO ; Hee Yeon KIM ; Yu Rim SHIN ; Jung Hwan YU ; Moon Young KIM ; YoungRok CHOI ; Young Eun CHON ; Eun Ju CHO ; Eun Joo LEE ; Sang Gyune KIM ; Won KIM ; Dae Won JUN ; Seung Up KIM ;
Clinical and Molecular Hepatology 2024;30(suppl):s5-s105
8.Successful Heart Transplantation Despite Rhesus Blood Type Mismatch: A Case Report
Journal of Chest Surgery 2024;57(2):217-219
Matching for the rhesus (Rh) blood group is currently not taken into account in the organ allocation system. However, in Rh-mismatched transplantation, the primary concern is the potential for RhD-negative recipients to develop sensitization and produce anti-D antibodies if they receive a transfusion of RhD-positive blood. It is estimated that over 80% of RhD-negative recipients may experience Rh allosensitization when exposed to RhD-positive blood, although this occurrence is less common in recipients of solid organs. In theory, RhD-negative recipients who receive organs from RhD-positive donors are at risk of alloimmunization and the production of anti-D antibodies, which could complicate future blood product transfusions. However, our understanding of the impact of donor-recipient Rh mismatch on transplant outcomes, particularly in heart transplantation, is limited. We report a case of successful Rh-mismatched heart transplantation, which was effectively managed through the use of preoperative RhD immunoglobulin and plasmapheresis.
9.Successful Bridge to Heart Transplantation through Ventricular Assist Device Implantation and Concomitant Fontan Completion in a Patient with Glenn Physiology: A Case Report
Ji Hong KIM ; Ji Hoon KIM ; Ah Young KIM ; Yu Rim SHIN
Journal of Chest Surgery 2024;57(3):312-314
A 3-year-old boy with Glenn physiology exhibited refractory heart failure with reduced ejection fraction. To improve the patient’s oxygen saturation, he underwent ventricular assist device (VAD) implantation with concomitant Fontan completion. The extracardiac conduit Fontan operation was performed with a 4-mm fenestration. For VAD implantation, Berlin Heart cannulas were positioned at the left ventricular apex and the neo-aorta. Following weaning from cardiopulmonary bypass, a temporary continuous-flow VAD, equipped with an oxygenator, was utilized for support. After a stabilization period of 1 week, the continuous-flow VAD was replaced with a durable pulsatile-flow device. Following 3 months of support, the patient underwent transplantation without complications.The completion of the Fontan procedure at the time of VAD implantation, along with the use of a temporary continuous-flow device with an oxygenator, may aid in stabilizing postoperative hemodynamics. This approach could contribute to a safe transition to a durable pulsatile VAD in patients with Glenn physiology.
10.Pediatric Extracorporeal Membrane Oxygenation in Korea: A Multicenter Retrospective Study on Utilization and Outcomes Spanning Over a Decade
Yu Hyeon CHOI ; Won Kyoung JHANG ; Seong Jong PARK ; Hee Joung CHOI ; Min-su OH ; Jung Eun KWON ; Beom Joon KIM ; Ju Ae SHIN ; In Kyung LEE ; June Dong PARK ; Bongjin LEE ; Hyun CHUNG ; Jae Yoon NA ; Ah Young CHOI ; Joongbum CHO ; Jaeyoung CHOI ; Hwa Jin CHO ; Ah Young KIM ; Yu Rim SHIN ; Joung-Hee BYUN ; Younga KIM
Journal of Korean Medical Science 2024;39(3):e33-
Background:
Over the last decade, extracorporeal membrane oxygenation (ECMO) use in critically ill children has increased and is associated with favorable outcomes. Our study aims to evaluate the current status of pediatric ECMO in Korea, with a specific focus on its volume and changes in survival rates based on diagnostic indications.
Methods:
This multicenter study retrospectively analyzed the indications and outcomes of pediatric ECMO over 10 years in patients at 14 hospitals in Korea from January 2012 to December 2021. Four diagnostic categories (neonatal respiratory, pediatric respiratory, postcardiotomy, and cardiac-medical) and trends were compared between periods 1 (2012–2016) and 2 (2017–2021).
Results:
Overall, 1065 ECMO runs were performed on 1032 patients, with the annual number of cases remaining unchanged over the 10 years. ECMO was most frequently used for post-cardiotomy (42.4%), cardiac-medical (31.8%), pediatric respiratory (17.5%), and neonatal respiratory (8.2%) cases. A 3.7% increase and 6.1% decrease in pediatric respiratory and post-cardiotomy cases, respectively, were noted between periods 1 and 2.Among the four groups, the cardiac-medical group had the highest survival rate (51.2%), followed by the pediatric respiratory (46.4%), post-cardiotomy (36.5%), and neonatal respiratory (29.4%) groups. A consistent improvement was noted in patient survival over the 10 years, with a significant increase between the two periods from 38.2% to 47.1% (P = 0.004). Improvement in survival was evident in post-cardiotomy cases (30–45%, P = 0.002).Significant associations with mortality were observed in neonates, patients requiring dialysis, and those treated with extracorporeal cardiopulmonary resuscitation (P < 0.001). In pediatric respiratory ECMO, immunocompromised patients also showed a significant correlation with mortality (P < 0.001).
Conclusion
Pediatric ECMO demonstrated a steady increase in overall survival in Korea;however, further efforts are needed since the outcomes remain suboptimal compared with global outcomes.

Result Analysis
Print
Save
E-mail