1.National trends in surgical treatment and clinical outcomes among patients with aneurysmal subarachnoid hemorrhage in the Republic of Korea
Yung Ki PARK ; Byul-Hee YOON ; Eui-Hyun HWANG ; Jae Hoon KIM ; Hee In KANG ; Yu Deok WON ; Jin Whan CHEONG
Journal of Cerebrovascular and Endovascular Neurosurgery 2025;27(1):19-32
Objective:
In this study, changes in treatment methods and patient prognosis were analyzed using a Korean nationwide medical insurance information database.
Methods:
Patients with subarachnoid hemorrhage who received surgical treatment for cerebral aneurysm from 2005 to 2020 were included. The specific surgery type was classified using the surgical code and according to whether stents were used. Yearly trends in mortality rates and poor prognosis, using tracheostomy as proxy, were analyzed by a simple regression analysis. A multistep logistic regression analysis was performed to evaluate the risk factors of mortality and poor prognosis.
Results:
Overall, 83,587 patients were included. Females were predominant (64.5%). Microsurgical clip usage rate decreased by approximately two-thirds from 78.8% in 2005 to 24.4% in 2020. Contrarily, endovascular treatment proportion gradually increased, and stent-assisted coil embolization rate surpassed microsurgical clip usage rate in 2020 (24.6% vs. 24.4%). In the multivariate analysis, endovascular treatment correlated positively with 3-month mortality (hazard ratio [HR]: 1.13, 95% confidence interval [CI]: 1.07–1.19, P<0.0001), although correlated negatively with poor prognosis (tracheostomy) (HR: 0.93, 95% CI: 0.89–0.98, P=0.0050).
Conclusions
According to the treatment trend analysis, during the 16 years studied, for patients with subarachnoid hemorrhage due to ruptured cerebral aneurysm, the endovascular treatment rate increased rapidly and stent-assisted coil embolization rate surpassed that of microsurgical clip ligation. Diversification of treatment methods has led to a decrease in mortality and improved prognosis.
2.Sentinel Safety Monitoring System for Adverse Events of Special Interest Associated With Non-NIP Vaccines in Korea
Hakjun HYUN ; Jung Yeon HEO ; Yu Jung CHOI ; Eliel NHAM ; Jin Gu YOON ; Ji Yun NOH ; Joon Young SONG ; Woo Joo KIM ; Won Suk CHOI ; Min Joo CHOI ; Yu Bin SEO ; Jacob LEE ; Hee Jin CHEONG
Journal of Korean Medical Science 2025;40(16):e152-
South Korea’s current vaccination policies leave a surveillance gap for non-National Immunization Program (NIP) vaccines. In this study, we proposed a sentinel surveillance approach for monitoring the safety of non-NIP vaccines. Vaccination data were collected retrospectively among patients hospitalized with pre-defined adverse events of special interest (AESI) by reviewing electronic medical records in five university hospitals. This approach incorporates expert assessment to determine the causal relationship. We confirmed that 16 patients had received non-NIP vaccines among 860 patients diagnosed with AESI.We concluded one case of preeclampsia was possibly related to tetanus-diphtheria-pertussis vaccination. We propose a multi-hospital-based, retrospective assessment system for predefined AESIs as an alternative to active vaccine safety monitoring method. These efforts are expected to enhance both the accuracy and timeliness of safety monitoring in South Korea.
3.Sentinel Safety Monitoring System for Adverse Events of Special Interest Associated With Non-NIP Vaccines in Korea
Hakjun HYUN ; Jung Yeon HEO ; Yu Jung CHOI ; Eliel NHAM ; Jin Gu YOON ; Ji Yun NOH ; Joon Young SONG ; Woo Joo KIM ; Won Suk CHOI ; Min Joo CHOI ; Yu Bin SEO ; Jacob LEE ; Hee Jin CHEONG
Journal of Korean Medical Science 2025;40(16):e152-
South Korea’s current vaccination policies leave a surveillance gap for non-National Immunization Program (NIP) vaccines. In this study, we proposed a sentinel surveillance approach for monitoring the safety of non-NIP vaccines. Vaccination data were collected retrospectively among patients hospitalized with pre-defined adverse events of special interest (AESI) by reviewing electronic medical records in five university hospitals. This approach incorporates expert assessment to determine the causal relationship. We confirmed that 16 patients had received non-NIP vaccines among 860 patients diagnosed with AESI.We concluded one case of preeclampsia was possibly related to tetanus-diphtheria-pertussis vaccination. We propose a multi-hospital-based, retrospective assessment system for predefined AESIs as an alternative to active vaccine safety monitoring method. These efforts are expected to enhance both the accuracy and timeliness of safety monitoring in South Korea.
4.Sentinel Safety Monitoring System for Adverse Events of Special Interest Associated With Non-NIP Vaccines in Korea
Hakjun HYUN ; Jung Yeon HEO ; Yu Jung CHOI ; Eliel NHAM ; Jin Gu YOON ; Ji Yun NOH ; Joon Young SONG ; Woo Joo KIM ; Won Suk CHOI ; Min Joo CHOI ; Yu Bin SEO ; Jacob LEE ; Hee Jin CHEONG
Journal of Korean Medical Science 2025;40(16):e152-
South Korea’s current vaccination policies leave a surveillance gap for non-National Immunization Program (NIP) vaccines. In this study, we proposed a sentinel surveillance approach for monitoring the safety of non-NIP vaccines. Vaccination data were collected retrospectively among patients hospitalized with pre-defined adverse events of special interest (AESI) by reviewing electronic medical records in five university hospitals. This approach incorporates expert assessment to determine the causal relationship. We confirmed that 16 patients had received non-NIP vaccines among 860 patients diagnosed with AESI.We concluded one case of preeclampsia was possibly related to tetanus-diphtheria-pertussis vaccination. We propose a multi-hospital-based, retrospective assessment system for predefined AESIs as an alternative to active vaccine safety monitoring method. These efforts are expected to enhance both the accuracy and timeliness of safety monitoring in South Korea.
5.National trends in surgical treatment and clinical outcomes among patients with aneurysmal subarachnoid hemorrhage in the Republic of Korea
Yung Ki PARK ; Byul-Hee YOON ; Eui-Hyun HWANG ; Jae Hoon KIM ; Hee In KANG ; Yu Deok WON ; Jin Whan CHEONG
Journal of Cerebrovascular and Endovascular Neurosurgery 2025;27(1):19-32
Objective:
In this study, changes in treatment methods and patient prognosis were analyzed using a Korean nationwide medical insurance information database.
Methods:
Patients with subarachnoid hemorrhage who received surgical treatment for cerebral aneurysm from 2005 to 2020 were included. The specific surgery type was classified using the surgical code and according to whether stents were used. Yearly trends in mortality rates and poor prognosis, using tracheostomy as proxy, were analyzed by a simple regression analysis. A multistep logistic regression analysis was performed to evaluate the risk factors of mortality and poor prognosis.
Results:
Overall, 83,587 patients were included. Females were predominant (64.5%). Microsurgical clip usage rate decreased by approximately two-thirds from 78.8% in 2005 to 24.4% in 2020. Contrarily, endovascular treatment proportion gradually increased, and stent-assisted coil embolization rate surpassed microsurgical clip usage rate in 2020 (24.6% vs. 24.4%). In the multivariate analysis, endovascular treatment correlated positively with 3-month mortality (hazard ratio [HR]: 1.13, 95% confidence interval [CI]: 1.07–1.19, P<0.0001), although correlated negatively with poor prognosis (tracheostomy) (HR: 0.93, 95% CI: 0.89–0.98, P=0.0050).
Conclusions
According to the treatment trend analysis, during the 16 years studied, for patients with subarachnoid hemorrhage due to ruptured cerebral aneurysm, the endovascular treatment rate increased rapidly and stent-assisted coil embolization rate surpassed that of microsurgical clip ligation. Diversification of treatment methods has led to a decrease in mortality and improved prognosis.
6.National trends in surgical treatment and clinical outcomes among patients with aneurysmal subarachnoid hemorrhage in the Republic of Korea
Yung Ki PARK ; Byul-Hee YOON ; Eui-Hyun HWANG ; Jae Hoon KIM ; Hee In KANG ; Yu Deok WON ; Jin Whan CHEONG
Journal of Cerebrovascular and Endovascular Neurosurgery 2025;27(1):19-32
Objective:
In this study, changes in treatment methods and patient prognosis were analyzed using a Korean nationwide medical insurance information database.
Methods:
Patients with subarachnoid hemorrhage who received surgical treatment for cerebral aneurysm from 2005 to 2020 were included. The specific surgery type was classified using the surgical code and according to whether stents were used. Yearly trends in mortality rates and poor prognosis, using tracheostomy as proxy, were analyzed by a simple regression analysis. A multistep logistic regression analysis was performed to evaluate the risk factors of mortality and poor prognosis.
Results:
Overall, 83,587 patients were included. Females were predominant (64.5%). Microsurgical clip usage rate decreased by approximately two-thirds from 78.8% in 2005 to 24.4% in 2020. Contrarily, endovascular treatment proportion gradually increased, and stent-assisted coil embolization rate surpassed microsurgical clip usage rate in 2020 (24.6% vs. 24.4%). In the multivariate analysis, endovascular treatment correlated positively with 3-month mortality (hazard ratio [HR]: 1.13, 95% confidence interval [CI]: 1.07–1.19, P<0.0001), although correlated negatively with poor prognosis (tracheostomy) (HR: 0.93, 95% CI: 0.89–0.98, P=0.0050).
Conclusions
According to the treatment trend analysis, during the 16 years studied, for patients with subarachnoid hemorrhage due to ruptured cerebral aneurysm, the endovascular treatment rate increased rapidly and stent-assisted coil embolization rate surpassed that of microsurgical clip ligation. Diversification of treatment methods has led to a decrease in mortality and improved prognosis.
7.Sentinel Safety Monitoring System for Adverse Events of Special Interest Associated With Non-NIP Vaccines in Korea
Hakjun HYUN ; Jung Yeon HEO ; Yu Jung CHOI ; Eliel NHAM ; Jin Gu YOON ; Ji Yun NOH ; Joon Young SONG ; Woo Joo KIM ; Won Suk CHOI ; Min Joo CHOI ; Yu Bin SEO ; Jacob LEE ; Hee Jin CHEONG
Journal of Korean Medical Science 2025;40(16):e152-
South Korea’s current vaccination policies leave a surveillance gap for non-National Immunization Program (NIP) vaccines. In this study, we proposed a sentinel surveillance approach for monitoring the safety of non-NIP vaccines. Vaccination data were collected retrospectively among patients hospitalized with pre-defined adverse events of special interest (AESI) by reviewing electronic medical records in five university hospitals. This approach incorporates expert assessment to determine the causal relationship. We confirmed that 16 patients had received non-NIP vaccines among 860 patients diagnosed with AESI.We concluded one case of preeclampsia was possibly related to tetanus-diphtheria-pertussis vaccination. We propose a multi-hospital-based, retrospective assessment system for predefined AESIs as an alternative to active vaccine safety monitoring method. These efforts are expected to enhance both the accuracy and timeliness of safety monitoring in South Korea.
8.Pharmacological properties of Technekitty injection (Tc-99m) in diagnosing feline hyperthyroidism
Jae Cheong LIM ; So-Young LEE ; Eun Ha CHO ; Yu Mi JUNG ; Ki Hwan PARK ; Young Uk PARK ; Sung Soo NAM ; Tae Hoon LEE ; Jae Won LEE ; Jisu SUN ; Hye Kyung CHUNG ; Yong Jin LEE ; Yeon CHAE ; Byeong-Teck KANG
Journal of Biomedical and Translational Research 2024;25(4):185-199
Thyroid scanning using technetium-99m ( 99mTc) is the gold standard for diagnosing feline hyperthyroidism. In cats with an overactive thyroid, a thyroid scan is the most appropriate imaging technique to detect and localize any hyperfunctional adenomatous thyroid tissue. In this study, the pharmacological properties of the Technekitty injection (Tc-99m), developed as a diagnostic agent for feline hyperthyroidism using 99mTc as an active ingredient, were tested in FRTL-5 thyroid follicular cell line and ICR mice. The percentage of cell uptake of the Tc-99m in FRTL-5 thyroid cells was 0.182 ± 0.018%, which was about 6 times higher compared to Clone 9 hepatocytes. This uptake decreased by 38.2% due to competitive inhibition by iodine (sodium iodide). In tissue distribution tests by using ICR mice, the highest distribution was observed in the liver, kidneys, spleen, lungs, and femur at 0.083 hours after administration, and this distribution decreased as the compound was excreted through the kidneys, the pri-mary excretory organ. Maximum distribution was confirmed at 1 hour in the small intestine, 6hours in the large intestine, and 2 hours in the thyroid gland. Additionally, the total amount excreted through urine and feces over 48 hours (2 days) was 78.80% of the injected dose, with 37.70% (47.84% of the total excretion) excreted through urine and 41.10% (52.16% of the total excretion) through feces. In conclusion, the Tc-99m has the same mechanism of action, potency, absorption, distribution, metabolism, and excretion characteristics as 99mTc used for feline hyperthyroidism in the United States, Europe, and other countries, because the Technekitty injection (Tc-99m) contains 99mTc as its sole active ingredient. Based on these results, the Technekitty injection (Tc-99m) is expected to be safely used in the clinical diagnosis of feline hyperthyroidism.
9.Pharmacological properties of Technekitty injection (Tc-99m) in diagnosing feline hyperthyroidism
Jae Cheong LIM ; So-Young LEE ; Eun Ha CHO ; Yu Mi JUNG ; Ki Hwan PARK ; Young Uk PARK ; Sung Soo NAM ; Tae Hoon LEE ; Jae Won LEE ; Jisu SUN ; Hye Kyung CHUNG ; Yong Jin LEE ; Yeon CHAE ; Byeong-Teck KANG
Journal of Biomedical and Translational Research 2024;25(4):185-199
Thyroid scanning using technetium-99m ( 99mTc) is the gold standard for diagnosing feline hyperthyroidism. In cats with an overactive thyroid, a thyroid scan is the most appropriate imaging technique to detect and localize any hyperfunctional adenomatous thyroid tissue. In this study, the pharmacological properties of the Technekitty injection (Tc-99m), developed as a diagnostic agent for feline hyperthyroidism using 99mTc as an active ingredient, were tested in FRTL-5 thyroid follicular cell line and ICR mice. The percentage of cell uptake of the Tc-99m in FRTL-5 thyroid cells was 0.182 ± 0.018%, which was about 6 times higher compared to Clone 9 hepatocytes. This uptake decreased by 38.2% due to competitive inhibition by iodine (sodium iodide). In tissue distribution tests by using ICR mice, the highest distribution was observed in the liver, kidneys, spleen, lungs, and femur at 0.083 hours after administration, and this distribution decreased as the compound was excreted through the kidneys, the pri-mary excretory organ. Maximum distribution was confirmed at 1 hour in the small intestine, 6hours in the large intestine, and 2 hours in the thyroid gland. Additionally, the total amount excreted through urine and feces over 48 hours (2 days) was 78.80% of the injected dose, with 37.70% (47.84% of the total excretion) excreted through urine and 41.10% (52.16% of the total excretion) through feces. In conclusion, the Tc-99m has the same mechanism of action, potency, absorption, distribution, metabolism, and excretion characteristics as 99mTc used for feline hyperthyroidism in the United States, Europe, and other countries, because the Technekitty injection (Tc-99m) contains 99mTc as its sole active ingredient. Based on these results, the Technekitty injection (Tc-99m) is expected to be safely used in the clinical diagnosis of feline hyperthyroidism.
10.Interim Estimates of 2023–2024Seasonal Influenza Vaccine Effectiveness Among Adults in Korea
Yu Jung CHOI ; Jang Wook SOHN ; Won Suk CHOI ; Seong-Heon WIE ; Jacob LEE ; Jin-Soo LEE ; Hye Won JEONG ; Joong Sik EOM ; Eliel NHAM ; Hye SEONG ; Jin Gu YOON ; Ji Yun NOH ; Joon Young SONG ; Hee Jin CHEONG ; Woo Joo KIM
Journal of Korean Medical Science 2024;39(15):e146-
In the 2023–2024 season, the influenza epidemic in South Korea peaked earlier than in recent years. In this study, we aimed to estimate the interim vaccine effectiveness (VE) of the influenza vaccination to prevent influenza during the early season. From November 1, 2023, to December 31, 2023, we enrolled 2,632 subjects with influenza-like illness from eight hospitals participating in hospital-based influenza morbidity and mortality surveillance. A retrospective test-negative case-control study was conducted to estimate the VE. The results showed an adjusted VE of 22.5% (95% confidence interval [CI], 6.6 to 35.8) for the total population. The adjusted VE was 22.3% (95% CI, 6.1 to 35.7) for influenza A and 9.4% (95% CI, −51.3 to 45.7) for influenza A/H1N1. Full results of the analysis will be reported.

Result Analysis
Print
Save
E-mail