1.5G remote robot-assisted thoracoscopic lobectomy/segmentectomy for ten patients
Fan SHEN ; Jia HUANG ; Yu TIAN ; Hanbo PAN ; Jiantao LI ; Long JIANG ; Hong GUO ; Bentong YU ; Qingquan LUO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(06):908-912
Objective To explore the safety and feasibility of 5G remote robot-assisted thoracoscopic anatomic lobectomy and segmentectomy. Methods A retrospective analysis was conducted on patients who underwent 5G remote robot-assisted thoracoscopic anatomic lobectomy or segmentectomy between July and September 2024. The surgeries were performed collaboratively by Shanghai Chest Hospital, Affiliated Hospital of Yangzhou University, and The First Affiliated Hospital of Nanchang University. Perioperative outcomes were recorded and analyzed. Results Ten patients were included, comprising 4 anatomic lobectomies and 6 segmentectomies. The median age was 61.0 (56.0, 72.0) years. The median intraoperative bi-directional network latency was 52.5 (39.0, 54.0) ms. There were no instances of network interruption, robot-related adverse events, or conversions to open thoracotomy. The median postoperative chest tube drainage volume was 500.0 (375.0, 600.0) mL, and the median hospital stay was 5.5 (4.0, 6.0) days. No complications of Clavien-Dindo grade Ⅱor higher occurred. All patients were recurrence-free and alive during the 6-month postoperative follow-up period. Conclusion 5G remote robot-assisted thoracoscopic surgery demonstrates high safety and operational stability. This technology shows promising potential for clinical application and is worthy of further development and utilization.
2.Establishment of multi-rule trend analysis for whole blood, washed red blood cells, and leukocyte-depleted suspended red blood cells
Shanshan LIU ; Ernan WAN ; Xiaotang YU ; Xue JIANG ; Hong YUAN
Chinese Journal of Blood Transfusion 2026;39(7):934-941
Objective: To present the plotting of trend analysis charts and the application of multi-rule trend analysis method for monitoring the quality of whole blood, washed red blood cells, and leukocyte-depleted suspended red blood cells. Methods: Samples of whole blood, washed red blood cells, and leukocyte-depleted suspended red blood cells were collected in accordance with relevant protocols and requirements. The results of blood quality testing were compiled. The trend line charts were plotted for the deviation rates of volume, hemoglobin (Hb) content, supernatant protein content, and leukocyte residual count. In addition, the trend line chart were plotted for hematocrit and post-storage hemolysis rate. Results: The trend analysis rules for the deviation rate of volume from the standard were: 1
categorized as out-of-control, (3 of 4)
as warning, R
as warning, 8
as alert, and 12
as alert. For Hb content deviation rate, the rules were: <0% categorized as out-of-control; <20% but ≥0% (for whole blood) or <10% but ≥0% (for washed red blood cells and leukocyte-depleted suspended red blood cells) as a warning. For supernatant protein content deviation rate, the rules were: ≥0.0% as out-of-control, and >-10% but <0.0% as a warning. For hematocrit, the rules were: 1
as out-of-control and (3 of 4)
as warning. For leukocyte residual count deviation rate, the rules were: >0.0% as out-of-control, and >-10% but ≤0.0% as a warning. For post-storage hemolysis rate, the rule was: ≥0.8% out-of-control. Conclusion: The application of multi-rule trend analysis facilitates the timely identification of trend abnormalities and factors causing deviations in the collection and preparation processes of whole blood, washed red blood cells, and leukocyte-depleted suspended red blood cells, thereby providing reliable numerical evidence for their correction and adjustment.
3.Current Status and Prospects of Artificial Intelligence Technologyin Minimally Invasive Gastric Cancer Surgery
Tao ZHANG ; Boer SU ; Guanxing LIANG ; Shiman DAI ; Jiawei CHEN ; Zhengjie LIU ; Cheng PENG ; Rong LIU ; Qinglan LIN ; Yidan WU ; Yuhui WU ; Jiaming WEN ; Hong WANG ; Hao CHEN ; Jiang YU
Medical Journal of Peking Union Medical College Hospital 2026;17(4):933-942
Gastric cancer remains a highly prevalent malignancy worldwide, with surgical resection currently constituting the cornerstone of treatment aimed at improving long-term patient survival. Owing to their notable advantages, including reduced surgical trauma and accelerated postoperative recovery, minimally invasive procedures are progressively supplanting conventional open surgery and have become the mainstream approach in gastric cancer management. Concurrently, the rapid advancement of artificial intelligence (AI) technologies has enabled real-time intraoperative monitoring of surgical scenes, thereby furnishing novel technical support for adjunctive decision-making, surgical navigation, and skill assessment during gastrectomy. This article provides a systematic review of the current status of AI applications in minimally invasive gastric cancer surgery, with a particular focus on research progress pertaining to instrument recognition, surgical phase identification, delineation of normal anatomical structures, detection of metastatic foci, and early warning of intraoperative adverse events. Furthermore, we discuss the potential value of AI in enhancing surgical efficiency, ensuring patient safety, and optimizing surgical education. On this basis, we further analyze the principal challenges and inherent risks confronting current AI systems, with the aim of informing future technological innovation and facilitating clinical translation.
4.Consistency analysis of macular microvascular parameters measured by three OCTA devices in patients with long-term hydroxychloroquine administration
Hong JIANG ; Xinyue YU ; Yajing HAO ; Lijing CHAI
International Eye Science 2026;26(9):1616-1622
AIM:To compare the consistency of macular microvascular parameters measured by three devices: frequency-domain optical coherence tomography angiography(FD-OCTA)with split-spectrum amplitude-decorrelation angiography(SSADA), FD-OCTA with optical microangiography(OMAG), and swept-source OCTA(SS-OCTA), in patients with long-term hydroxychloroquine(HCQ)administration for rheumatoid arthritis(RA).METHODS:This prospective study enrolled patients treated with HCQ for 5 y due to RA who visited the Department of Ophthalmology of the hospital from January 2022 to November 2025. All subjects underwent a 6 mm×6 mm macular scan with three OCTA devices in random order, with a 5-minute interval between examinations by different devices. Images of the superficial capillary plexus(SCP)and deep capillary plexus(DCP)were acquired. The following microvascular parameters were compared: foveal superficial capillary plexus vessel density(F-SCP VD), parafoveal superficial capillary plexus vessel density(PF-SCP VD), foveal deep capillary plexus vessel density(F-DCP VD), parafoveal deep capillary plexus vessel density(PF-DCP VD), and the area of the foveal avascular zone(FAZ).RESULTS:A total of 34 female patients(68 eyes)treated with HCQ for 5 y due to RA were enrolled in this study, aged 38-58 y with a mean age of 49.3±5.05 y. Statistically significant differences were found in F-SCP VD, PF-SCP VD, F-DCP VD, PF-DCP VD, and FAZ area among measurements obtained by SS-OCTA, SSADA-based FD-OCTA, and OMAG-based FD-OCTA(all P<0.05). No statistically significant differences in all above parameters were observed between SSADA-based FD-OCTA and OMAG-based FD-OCTA(all P>0.05). FAZ areas measured by the three devices were highly positively correlated(|r|≥0.8, P<0.01). The F-SCP VD, PF-SCP VD, F-DCP VD, and PF-DCP VD values obtained by SSADA-based FD-OCTA and OMAG-based FD-OCTA were all highly positively correlated(|r|≥0.8, P<0.01). The PF-SCP VD and PF-DCP VD values measured by SS-OCTA versus SSADA-based FD-OCTA and OMAG-based FD-OCTA showed moderate positive correlations(0.5≤|r|<0.8, P<0.01). The F-SCP VD and F-DCP VD values measured by SS-OCTA versus SSADA-based FD-OCTA and OMAG-based FD-OCTA exhibited low positive correlations(0.3≤|r|<0.5, P<0.05). Bland-Altman plots demonstrated good agreement between SSADA-based FD-OCTA and OMAG-based FD-OCTA for the measurements of F-SCP VD, PF-SCP VD, F-DCP VD and PF-DCP VD. By contrast, poor agreement was observed when comparing SS-OCTA with SSADA-based FD-OCTA or OMAG-based FD-OCTA for measurements of F-SCP VD, PF-SCP VD, F-DCP VD and PF-DCP VD.Satisfactory agreement was found among the three OCTA devices for FAZ area measurements.CONCLUSION:SSADA-based FD-OCTA and OMAG-based FD-OCTA show favorable correlation and agreement in measuring macular vessel density of patients receiving HCQ, which allows cautious interchangeable use during clinical follow-up. The vessel density parameters measured by SS-OCTA were markedly different from those obtained by SSADA-based FD-OCTA and OMAG-based FD-OCTA; therefore, these devices cannot be directly interchanged.FAZ area measurements exhibit favorable inter-device agreement among the three systems, and interchangeability should be considered in the context of clinical practice.
5.Pharmaceutical services for patients with CTLA-4 haploid deficiency and severe malnutrition
Di LIU ; Jianping CAO ; Hong YU ; Taofeng JIANG ; Xiaobin MENG
China Pharmacy 2026;37(15):2045-2050
OBJECTIVE To provide a reference for clinical pharmacists to participate in the treatment of rare and complex cases of CTLA-4 haploid deficiency combined with severe malnutrition. METHODS The clinical pharmacist participated in the diagnosis and treatment of a complex case of CTLA-4 haploid deficiency with severe malnutrition, type 1 diabetes, blood coagulation abnormalities with gastrointestinal bleeding and virus infection, assisted the doctor to develop an individualized parenteral nutrition program, and dynamically adjusted the ratio of glucose and insulin (from 3.9∶1 to 15.6∶1). When patient had severe coagulation abnormalities and gastrointestinal bleeding, the clinical pharmacist recommended discontinuing fat emulsion and switching to glucose amino acid dual energy supply; when the patient had a high fever accompanied by a sudden drop in platelets, the clinical pharmacist recommended to improve the second-generation sequencing of plasma metagenomics. Based on positive results for both EB virus and cytomegalovirus, the clinical pharmacist recommended to discontinue meropenem and switch to ganciclovir for antiviral treatment; when the patient experienced systemic itching and mental excitement, the clinical pharmacist quickly diagnosed as an adverse reaction of ganciclovir and recommended to switch to acyclovir for antiviral treatment. The clinical pharmacist simultaneously carried out parenteral nutrition medication education, and standardized infusion speed, and continuously monitored bleeding-related indicators. RESULTS The physician adopted the advice of the clinical pharmacist. After comprehensive intervention, the patient’s body temperature returned to normal, gastrointestinal bleeding stopped, coagulation indicators significantly improved, blood sugar control reached the standard, and the condition improved and the patient was discharged. CONCLUSIONS Clinical pharmacists rely on comprehensive pharmaceutical services to balance the benefits and risks of treatment for rare and complex cases. They play a key role in individualized nutrition planning, refined blood glucose control, infection identification and anti-infection optimization, and identification and treatment of adverse drug reactions to ensure patient medication safety and efficacy.
6.Antibody threshold and demographic characteristics of low-titer group O whole blood donors in Jiangsu
Tao FENG ; Rui ZHU ; Wenjia HU ; Ling MA ; Hong LIN ; Xi YU ; Chun ZHOU ; Nizhen JIANG
Chinese Journal of Blood Transfusion 2025;38(9):1225-1229
Objective: To investigate the distribution of IgM anti-A/B titers among group O whole blood donors in Jiangsu, establish a low-titer threshold, and analyze the demographic characteristics of low-titer donors, so as to provide data for recruiting low-titer group O whole blood (LTOWB) donors. Methods: Plasma samples from 1 009 group O whole blood donors were tested for IgM anti-A and anti-B titers using the microplate technique. The distribution of antibody titers was analyzed to establish a low-titer threshold. The distribution trends of titers across different demographic groups were also analyzed. Results: The peak titer for anti-A, anti-B were 64 (31.5%), 4 (23.8%), respectively, The proportion of donors with both anti-A and anti-B titers below 64 was 97.3% (982/1 009). The mean anti-A titer was higher than anti-B titer. Anti-A titers were higher in female donors than in male donors (P<0.05). The anti-A titers differed significantly among different age groups (P<0.05). However, no significant difference in titers was observed based on the number of donations (P>0.05). Conclusion: A titer of 64 can be used as the reference threshold of LTOWB in Jiangsu. Male donors of appropriate age are more suitable than female donors for establishing an emergency panel of LTOWB mobile donors.
8.Expert consensus on the diagnosis and treatment of cemental tear.
Ye LIANG ; Hongrui LIU ; Chengjia XIE ; Yang YU ; Jinlong SHAO ; Chunxu LV ; Wenyan KANG ; Fuhua YAN ; Yaping PAN ; Faming CHEN ; Yan XU ; Zuomin WANG ; Yao SUN ; Ang LI ; Lili CHEN ; Qingxian LUAN ; Chuanjiang ZHAO ; Zhengguo CAO ; Yi LIU ; Jiang SUN ; Zhongchen SONG ; Lei ZHAO ; Li LIN ; Peihui DING ; Weilian SUN ; Jun WANG ; Jiang LIN ; Guangxun ZHU ; Qi ZHANG ; Lijun LUO ; Jiayin DENG ; Yihuai PAN ; Jin ZHAO ; Aimei SONG ; Hongmei GUO ; Jin ZHANG ; Pingping CUI ; Song GE ; Rui ZHANG ; Xiuyun REN ; Shengbin HUANG ; Xi WEI ; Lihong QIU ; Jing DENG ; Keqing PAN ; Dandan MA ; Hongyu ZHAO ; Dong CHEN ; Liangjun ZHONG ; Gang DING ; Wu CHEN ; Quanchen XU ; Xiaoyu SUN ; Lingqian DU ; Ling LI ; Yijia WANG ; Xiaoyuan LI ; Qiang CHEN ; Hui WANG ; Zheng ZHANG ; Mengmeng LIU ; Chengfei ZHANG ; Xuedong ZHOU ; Shaohua GE
International Journal of Oral Science 2025;17(1):61-61
Cemental tear is a rare and indetectable condition unless obvious clinical signs present with the involvement of surrounding periodontal and periapical tissues. Due to its clinical manifestations similar to common dental issues, such as vertical root fracture, primary endodontic diseases, and periodontal diseases, as well as the low awareness of cemental tear for clinicians, misdiagnosis often occurs. The critical principle for cemental tear treatment is to remove torn fragments, and overlooking fragments leads to futile therapy, which could deteriorate the conditions of the affected teeth. Therefore, accurate diagnosis and subsequent appropriate interventions are vital for managing cemental tear. Novel diagnostic tools, including cone-beam computed tomography (CBCT), microscopes, and enamel matrix derivatives, have improved early detection and management, enhancing tooth retention. The implementation of standardized diagnostic criteria and treatment protocols, combined with improved clinical awareness among dental professionals, serves to mitigate risks of diagnostic errors and suboptimal therapeutic interventions. This expert consensus reviewed the epidemiology, pathogenesis, potential predisposing factors, clinical manifestations, diagnosis, differential diagnosis, treatment, and prognosis of cemental tear, aiming to provide a clinical guideline and facilitate clinicians to have a better understanding of cemental tear.
Humans
;
Dental Cementum/injuries*
;
Consensus
;
Diagnosis, Differential
;
Cone-Beam Computed Tomography
;
Tooth Fractures/therapy*
9.Inhibition of KLK8 promotes pulmonary endothelial repair by restoring the VE-cadherin/Akt/FOXM1 pathway.
Ying ZHAO ; Hui JI ; Feng HAN ; Qing-Feng XU ; Hui ZHANG ; Di LIU ; Juan WEI ; Dan-Hong XU ; Lai JIANG ; Jian-Kui DU ; Ping-Bo XU ; Yu-Jian LIU ; Xiao-Yan ZHU
Journal of Pharmaceutical Analysis 2025;15(4):101153-101153
Image 1.
10.Suppression of LIF in tumor-associated macrophages contributing to the PD-1/PD-L1 blockade in hepatocellular carcinoma.
Shuangshuang YIN ; Yanming LUO ; Miaomiao JIANG ; Lifeng HAN ; Sibao CHEN ; Leilei FU ; Yuling QIU ; Haiyang YU
Journal of Pharmaceutical Analysis 2025;15(10):101286-101286
Image 1.

Result Analysis
Print
Save
E-mail