1.The Effects of Nicotine on Re-endothelialization, Inflammation, and Neoatherosclerosis After Drug-Eluting Stent Implantation in a Porcine Model
Seok OH ; Ju Han KIM ; Saleem AHMAD ; Yu Jeong JIN ; Mi Hyang NA ; Munki KIM ; Jeong Ha KIM ; Dae Sung PARK ; Dae Young HYUN ; Kyung Hoon CHO ; Min Chul KIM ; Doo Sun SIM ; Young Joon HONG ; Seung-won LEE ; Youngkeun AHN ; Myung Ho JEONG
Korean Circulation Journal 2025;55(1):50-64
Background and Objectives:
Cigarette smoking is a major risk factor for atherosclerosis.Nicotine, a crucial constituent of tobacco, contributes to atherosclerosis development and progression. However, evidence of the association between nicotine and neointima formation is limited. We aimed to evaluate whether nicotine enhances neointimal hyperplasia in the native epicardial coronary arteries of pigs after percutaneous coronary intervention (PCI) with drug-eluting stents (DES).
Methods:
After coronary angiography (CAG) and quantitative coronary angiography (QCA), we implanted 20 DES into 20 pigs allocated to 2 groups: no-nicotine (n=10) and nicotine (n=10) groups. Post-PCI CAG and QCA were performed immediately. Follow-up CAG, QCA, optical coherence tomography (OCT), and histopathological analyses were performed 2 months post-PCI.
Results:
Despite intergroup similarities in the baseline QCA findings, OCT analysis showed that the nicotine group had a smaller mean stent and lumen areas, a larger mean neointimal area, greater percent area stenosis, and higher peri-strut fibrin and inflammation scores than the no-nicotine group. In immunofluorescence analysis, the nicotine group displayed higher expression of CD68 and α-smooth muscle actin but lower CD31 expression than the no-nicotine group.
Conclusions
Nicotine inhibited re-endothelialization and promoted inflammation and NIH after PCI with DES in a porcine model.
2.The Effects of Nicotine on Re-endothelialization, Inflammation, and Neoatherosclerosis After Drug-Eluting Stent Implantation in a Porcine Model
Seok OH ; Ju Han KIM ; Saleem AHMAD ; Yu Jeong JIN ; Mi Hyang NA ; Munki KIM ; Jeong Ha KIM ; Dae Sung PARK ; Dae Young HYUN ; Kyung Hoon CHO ; Min Chul KIM ; Doo Sun SIM ; Young Joon HONG ; Seung-won LEE ; Youngkeun AHN ; Myung Ho JEONG
Korean Circulation Journal 2025;55(1):50-64
Background and Objectives:
Cigarette smoking is a major risk factor for atherosclerosis.Nicotine, a crucial constituent of tobacco, contributes to atherosclerosis development and progression. However, evidence of the association between nicotine and neointima formation is limited. We aimed to evaluate whether nicotine enhances neointimal hyperplasia in the native epicardial coronary arteries of pigs after percutaneous coronary intervention (PCI) with drug-eluting stents (DES).
Methods:
After coronary angiography (CAG) and quantitative coronary angiography (QCA), we implanted 20 DES into 20 pigs allocated to 2 groups: no-nicotine (n=10) and nicotine (n=10) groups. Post-PCI CAG and QCA were performed immediately. Follow-up CAG, QCA, optical coherence tomography (OCT), and histopathological analyses were performed 2 months post-PCI.
Results:
Despite intergroup similarities in the baseline QCA findings, OCT analysis showed that the nicotine group had a smaller mean stent and lumen areas, a larger mean neointimal area, greater percent area stenosis, and higher peri-strut fibrin and inflammation scores than the no-nicotine group. In immunofluorescence analysis, the nicotine group displayed higher expression of CD68 and α-smooth muscle actin but lower CD31 expression than the no-nicotine group.
Conclusions
Nicotine inhibited re-endothelialization and promoted inflammation and NIH after PCI with DES in a porcine model.
3.The Effects of Nicotine on Re-endothelialization, Inflammation, and Neoatherosclerosis After Drug-Eluting Stent Implantation in a Porcine Model
Seok OH ; Ju Han KIM ; Saleem AHMAD ; Yu Jeong JIN ; Mi Hyang NA ; Munki KIM ; Jeong Ha KIM ; Dae Sung PARK ; Dae Young HYUN ; Kyung Hoon CHO ; Min Chul KIM ; Doo Sun SIM ; Young Joon HONG ; Seung-won LEE ; Youngkeun AHN ; Myung Ho JEONG
Korean Circulation Journal 2025;55(1):50-64
Background and Objectives:
Cigarette smoking is a major risk factor for atherosclerosis.Nicotine, a crucial constituent of tobacco, contributes to atherosclerosis development and progression. However, evidence of the association between nicotine and neointima formation is limited. We aimed to evaluate whether nicotine enhances neointimal hyperplasia in the native epicardial coronary arteries of pigs after percutaneous coronary intervention (PCI) with drug-eluting stents (DES).
Methods:
After coronary angiography (CAG) and quantitative coronary angiography (QCA), we implanted 20 DES into 20 pigs allocated to 2 groups: no-nicotine (n=10) and nicotine (n=10) groups. Post-PCI CAG and QCA were performed immediately. Follow-up CAG, QCA, optical coherence tomography (OCT), and histopathological analyses were performed 2 months post-PCI.
Results:
Despite intergroup similarities in the baseline QCA findings, OCT analysis showed that the nicotine group had a smaller mean stent and lumen areas, a larger mean neointimal area, greater percent area stenosis, and higher peri-strut fibrin and inflammation scores than the no-nicotine group. In immunofluorescence analysis, the nicotine group displayed higher expression of CD68 and α-smooth muscle actin but lower CD31 expression than the no-nicotine group.
Conclusions
Nicotine inhibited re-endothelialization and promoted inflammation and NIH after PCI with DES in a porcine model.
4.The Effects of Nicotine on Re-endothelialization, Inflammation, and Neoatherosclerosis After Drug-Eluting Stent Implantation in a Porcine Model
Seok OH ; Ju Han KIM ; Saleem AHMAD ; Yu Jeong JIN ; Mi Hyang NA ; Munki KIM ; Jeong Ha KIM ; Dae Sung PARK ; Dae Young HYUN ; Kyung Hoon CHO ; Min Chul KIM ; Doo Sun SIM ; Young Joon HONG ; Seung-won LEE ; Youngkeun AHN ; Myung Ho JEONG
Korean Circulation Journal 2025;55(1):50-64
Background and Objectives:
Cigarette smoking is a major risk factor for atherosclerosis.Nicotine, a crucial constituent of tobacco, contributes to atherosclerosis development and progression. However, evidence of the association between nicotine and neointima formation is limited. We aimed to evaluate whether nicotine enhances neointimal hyperplasia in the native epicardial coronary arteries of pigs after percutaneous coronary intervention (PCI) with drug-eluting stents (DES).
Methods:
After coronary angiography (CAG) and quantitative coronary angiography (QCA), we implanted 20 DES into 20 pigs allocated to 2 groups: no-nicotine (n=10) and nicotine (n=10) groups. Post-PCI CAG and QCA were performed immediately. Follow-up CAG, QCA, optical coherence tomography (OCT), and histopathological analyses were performed 2 months post-PCI.
Results:
Despite intergroup similarities in the baseline QCA findings, OCT analysis showed that the nicotine group had a smaller mean stent and lumen areas, a larger mean neointimal area, greater percent area stenosis, and higher peri-strut fibrin and inflammation scores than the no-nicotine group. In immunofluorescence analysis, the nicotine group displayed higher expression of CD68 and α-smooth muscle actin but lower CD31 expression than the no-nicotine group.
Conclusions
Nicotine inhibited re-endothelialization and promoted inflammation and NIH after PCI with DES in a porcine model.
5.General considerations for the design of bioequivalence studies of etomidate medium/long-chain fat emulsion injection
Na AN ; Dong LI ; Li-Li LIU ; Fang LI ; Li-Li HA ; Man-Ru REN ; Yu ZHOU
The Chinese Journal of Clinical Pharmacology 2024;40(10):1541-1544
Etomidate reversibly blocks 11-β-hydroxylated steroid dehydrogenase inhibits the synthesis of cortisol by adrenal cells.This product is a special injection.When evaluating the quality and efficacy of the generic and the reference preparations,it should be based on pharmaceutical and non-clinical consistency and adopt a step-by-step research strategy,firstly,bioequivalence(BE)was studied.In bioequivalence study,the research type,dosage and method,bioequivalence evaluation,safety monitoring and pharmacodynamics(PD)evaluation should be considered and designed reasonably.Based on the pharmacokinetics(PK)characteristics of etomidate medium-long chain fat emulsion injection and the bioequivalence study of its generic drug before its domestic market,the general design requirements and relevant considerations for the bioequivalence study of this product were systematically discussed.The purpose is to provide useful reference and guidance for domestic research and development of generic drugs.
6.Impact of Infection Prevention Programs on Catheter-Associated Urinary Tract Infections Analyzed in Multicenter Study
Sun Hee NA ; Joong Sik EOM ; Yu Bin SEO ; Sun Hee PARK ; Young Keun KIM ; Wonkeun SONG ; Eunjung LEE ; Sung Ran KIM ; Hyeon Mi YOO ; Heekyung CHUN ; Myoung Jin SHIN ; Su Hyun KIM ; Ji Youn CHOI ; Nan hyoung CHO ; Jin Hwa KIM ; Hee-jung SON ; Su ha HAN ; Jacob LEE
Journal of Korean Medical Science 2024;39(18):e151-
Background:
Catheter-associated urinary tract infections (CAUTIs) account for a large proportion of healthcare-associated infections and have a significant impact on morbidity, length of hospital stay, and mortality. Adherence to the recommended infection prevention practices can effectively reduce the incidence of CAUTIs. This study aimed to assess the characteristics of CAUTIs and the efficacy of prevention programs across hospitals of various sizes.
Methods:
Intervention programs, including training, surveillance, and monitoring, were implemented. Data on the microorganisms responsible for CAUTIs, urinary catheter utilization ratio, rate of CAUTIs per 1,000 device days, and factors associated with the use of indwelling catheters were collected from 2017 to 2019. The incidence of CAUTIs and associated data were compared between university hospitals and small- and medium-sized hospitals.
Results:
Thirty-two hospitals participated in the study, including 21 university hospitals and 11 small- and medium-sized hospitals. The microorganisms responsible for CAUTIs and their resistance rates did not differ between the two groups. In the first quarter of 2018, the incidence rate was 2.05 infections/1,000 device-days in university hospitals and 1.44 infections/1,000 device-days in small- and medium-sized hospitals. After implementing interventions, the rate gradually decreased in the first quarter of 2019, with 1.18 infections/1,000 device-days in university hospitals and 0.79 infections/1,000 device-days in small- and medium-sized hospitals. However, by the end of the study, the infection rate increased to 1.74 infections/1,000 device-days in university hospitals and 1.80 infections/1,000 device-days in small- and medium-sized hospitals.
Conclusion
We implemented interventions to prevent CAUTIs and evaluated their outcomes. The incidence of these infections decreased in the initial phases of the intervention when adequate support and personnel were present. The rate of these infections may be reduced by implementing active interventions such as consistent monitoring and adherence to guidelines for preventing infections.
7.Preliminary Investigation on Efficacy and Safety of Substance P-Coated Stent for Promoting Re-Endothelialization: A Porcine Coronary Artery Restenosis Model
Dae Sung PARK ; Seok OH ; Yu Jeong JIN ; Mi Hyang NA ; Munki KIM ; Jeong Ha KIM ; Dae Young HYUN ; Kyung Hoon CHO ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN ; Manuel HERMIDA-PRIETO ; José Manuel VÁZQUEZ-RODRIGUEZ ; Juan Luis GUTIÉRREZ- CHICO ; Luis MARINÃS-PARDO ; Kyung Seob LIM ; Jun-Kyu PARK ; Dae-Heung BYEON ; Young-Nan CHO ; Seung-Jung KEE ; Doo Sun SIM ; Myung Ho JEONG
Tissue Engineering and Regenerative Medicine 2024;21(1):53-64
BACKGROUND:
Current polymer-based drug-eluting stents (DESs) have fundamental issues about inflammation and delayed re-endothelializaton of the vessel wall. Substance-P (SP), which plays an important role in inflammation and endothelial cells, has not yet been applied to coronary stents. Therefore, this study compares poly lactic-co-glycolic acid (PLGA)-based everolimus-eluting stents (PLGA-EESs) versus 2-methacryloyloxyethyl phosphorylcholine (MPC)-based SP-eluting stents (MPC-SPs) in in-vitro and in-vivo models.
METHODS:
The morphology of the stent surface and peptide/drug release kinetics from stents were evaluated. The invitro proliferative effect of SP released from MPC-SP is evaluated using human umbilical vein endothelial cell. Finally, the safety and efficacy of the stent are evaluated after inserting it into a pig’s coronary artery.
RESULTS:
Similar to PLGA-EES, MPC-SP had a uniform surface morphology with very thin coating layer thickness (2.074 lm). MPC-SP showed sustained drug release of SP for over 2 weeks. Endothelial cell proliferation was significantly increased in groups treated with SP (n = 3) compared with the control (n = 3) and those with everolimus (n = 3) (SP:118.9 ± 7.61% vs. everolimus: 64.3 ± 12.37% vs. the control: 100 ± 6.64%, p < 0.05). In the animal study, the percent stenosis was higher in MPC-SP group (n = 7) compared to PLGA-EES group (n = 7) (MPC-SP: 28.6 ± 10.7% vs. PLGAEES: 16.7 ± 6.3%, p < 0.05). MPC-SP group showed, however, lower inflammation (MPC-SP: 0.3 ± 0.26 vs. PLGAEES: 1.2 ± 0.48, p < 0.05) and fibrin deposition (MPC-SP: 1.0 ± 0.73 vs. PLGA-EES: 1.5 ± 0.59, p < 0.05) around the stent strut. MPC-SP showed more increased expression of cluster of differentiation 31, suggesting enhanced reendothelialization.
CONCLUSION
Compared to PLGA-EES, MPC-SP demonstrated more decreased inflammation of the vascular wall and enhanced re-endothelialization and stent coverage. Hence, MPC-SP has the potential therapeutic benefits for the treatment of coronary artery disease by solving limitations of currently available DESs.
8.Efficacy and Safety Evaluation of Tacrolimus-Eluting Stent in a Porcine Coronary Artery Model
Dae Sung PARK ; Mi Hyang NA ; Myung Ho JEONG ; Doo Sun SIM ; Yu Jeong JIN ; Hae Jin KEE ; Mun Ki KIM ; Jeong Ha KIM ; Young Joon HONG ; Kyung Hoon CHO ; Dae Young HYUN ; Seok OH ; Kyung Seob LIM ; Dae-Heung BYEON ; Jeong Hun KIM
Tissue Engineering and Regenerative Medicine 2024;21(5):723-735
BACKGROUND:
A drug-eluting stent (DES) is a highly beneficial medical device used to widen or unblock narrowed blood vessels. However, the drugs released by the implantation of DES may hinder the re-endothelialization process, increasing the risk of late thrombosis. We have developed a tacrolimus-eluting stent (TES) that as acts as a potent antiproliferative and immunosuppressive agent, enhancing endothelial regeneration. In addition, we assessed the safety and efficacy of TES through both in vitro and in vivo tests.
METHODS:
Tacrolimus and Poly(lactic-co-glycolic acid) (PLGA) were applied to the metal stent using electrospinning equipment. The surface morphology of the stent was examined before and after coating using a scanning electron microscope (SEM) and energy dispersive X-rays (EDX). The drug release test was conducted through high-performance liquid chromatography (HPLC). Cell proliferation and migration assays were performed using smooth muscle cells (SMC).The stent was then inserted into the porcine coronary artery and monitored for a duration of 4 weeks.
RESULTS:
SEM analysis confirmed that the coating surface was uniform. Furthermore, EDX analysis showed that the surface was coated with both polymer and drug components. The HPCL analysis of TCL at a wavelength of 215 nm revealed that the drug was continuously released over a period of 4 weeks. Smooth muscle cell migration was significantly decreased in the tacrolimus group (54.1% ± 11.90%) compared to the non-treated group (90.1% ± 4.86%). In animal experiments, the stenosis rate was significantly reduced in the TES group (29.6% ± 7.93%) compared to the bare metal stent group (41.3% ± 10.18%). Additionally, the fibrin score was found to be lower in the TES group compared to the group treated with a sirolimus-eluting stent (SES).
CONCLUSION
Similar to SES, TES reduces neointimal proliferation in a porcine coronary artery model, specifically decreasing the fibrins score. Therefore, tacrolimus could be considered a promising drug for reducing restenosis and thrombosis.
9.Preclinical Evaluation of an Everolimus-Eluting Bioresorbable Vascular Scaffold Via a Long-Term Rabbit Iliac Artery Model
Dae Sung PARK ; Myung Ho JEONG ; Yu Jeong JIN ; Mi Hyang NA ; Doo Sun SIM ; Munki KIM ; Kyung Hoon CHO ; Dae Young HYUN ; Seok OH ; Jeong Ha KIM ; Kyung Seob LIM ; Jun-Kyu PARK ; Han Ki KIM ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN ; Jeong Hun KIM
Tissue Engineering and Regenerative Medicine 2023;20(2):239-249
BACKGROUND:
Biodegradable poly (l-lactic acid) (PLLA), a bio safe polymer with a large elastic modulus, is widely used in biodegradable medical devices. However, because of its poor mechanical properties, a PLLA strut must be made twice as thick as a metal strut for adequate blood vessel support. Therefore, the mechanical properties of a drug-eluting metal-based stents (MBS) and a bioresorbable vascular scaffolds (BVS) were evaluated and their safety and efficacy were examined via a long-term rabbit iliac artery model.
METHODS:
The surface morphologies of the MBSs and BVSs were investigated via optical and scanning electron microscopy. An everolimus-eluting (EE) BVS or an EE-MBS was implanted into rabbit iliac arteries at a 1.1:1 stent-toartery ratio. Twelve months afterward, stented iliac arteries from each group were analyzed via X-ray angiography, optical coherence tomography (OCT), and histopathologic evaluation.
RESULTS:
Surface morphology analysis of the EE coating on the MBS confirmed that it was uniform and very thin (4.7 lm). Comparison of the mechanical properties of the EE-MBS and EE-BVS showed that the latter outperformed the former in all aspects (radial force (2.75 vs. 0.162 N/mm), foreshortening (0.24% vs. 1.9%), flexibility (0.52 vs. 0.19 N), and recoil (3.2% vs. 6.3%). At all time points, the percent area restenosis was increased in the EE-BVS group compared to the EE-MBS group. The OCT and histopathological analyses indicate no significant changes in strut thickness.
CONCLUSION
BVSs with thinner struts and shorter resorption times should be developed. A comparable long-term safety/efficacy evaluation after complete absorption of BVSs should be conducted.
10.Effect of COVID-19 (SARS-CoV-2) Vaccination on Patients with Atopic Dermatitis Treated with Dupilumab: A Multicenter, Observational Study
Tae Young HAN ; Dong Hyun SHIM ; Yu Jin LEE ; Young Bok LEE ; Ha Yeh Rin KOO ; Min Kyung SHIN ; Tae Eun KIM ; Yong Hyun JANG ; Jin Seon BANG ; Hyung Don KOOK ; Jiyoung AHN ; Hye Jung JUNG ; Chan Ho NA
Annals of Dermatology 2023;35(1):38-45
Background:
Atopic dermatitis (AD) patients usually wonder if their condition will worsen after vaccination or if they should continue with the treatment they are receiving. Considering that many patients treated with dupilumab had previously experienced severe AD symptoms and flares, the concerns are more understandable.
Objective:
This study aimed to investigate the safety of the coronavirus disease 2019 (COVID-19) vaccination in patients with AD treated with dupilumab.
Methods:
We enrolled 133 patients (101 dupilumab-treated and 32 systemic oral agentstreated as control group) with AD from six hospitals. Patients were asked about worsening pruritus and AD (5-point Likert scale) after vaccination. AD variables (eczema area and severity index [EASI], investigator’s global assessment [IGA], itch numerical rating scale [NRS], sleep NRS, and patient-oriented eczema measure [POEM]) were compared pre- and postvaccination. Adverse reactions to the COVID-19 vaccination were observed.
Results:
The incidence of adverse reactions to COVID-19 vaccines and worsening AD symptoms in dupilumab-treated patients were not significantly different compared with that in the control group. The itch NRS score increased significantly after vaccination (p<0.001).However, there were no statistically significant differences between the pre-and post-EASI, IGA, and POEM scores. Eight patients (7.9%) had worse EASI scores and required rescue therapy; however, most were easily managed with low-dose steroids or topical agents. None of the patients discontinued dupilumab treatment.
Conclusion
No serious adverse reactions were observed in patients with AD after COVID-19 vaccination. Exacerbation of pruritus and AD symptoms was observed but was mostly mild and transient.

Result Analysis
Print